HSHany A. Shousha

Hany A. Shousha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hany A. Shousha has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Natural radioactivity contents in tobacco and radiation dose induced from smoking

    by Hany A. Shousha, Fawzia Ahmad

    One of the causative factors for cancer-inducing mechanisms in humans is radioactive elements present in tobacco leaves used in the manufacture of cigarettes. Smoking of tobacco and its products increases the internal intake and radiation dose due to naturally occurring radionuclides that are considered to be one of the most significant causes of lung cancer. In this work, different commercial types of cigarettes, cigar and moassel were collected from market. Naturally occurring radionuclides 226Ra and 214Bi (238U series), 228Ac and 228Ra (232Th series), 40K and man-made 137Cs were measured in tobacco using gamma-ray spectrometer. Results show that the average concentrations of 238U, 232Th and 40K were 4.564, 3.940 and 1289.53 Bq kg−1, respectively. This reflects their origin from the soil by root uptake and fertilisers used in the cultivation of tobacco plants. Concentration of 137Cs was 0.348 Bq kg−1 due to root uptake or deposition onto the leaf foliage. For smokers, the annual effective dose due to inhalation of 238U varied from 49.35 to 139.40 μSv−1 (average 104.27 μSv y−1), while of 232Th from 23.86 to 111.06 μSv y−1 (average 65.52 μSv y−1). The annual effective dose resulting from 137Cs was varied from 10.96 to 24.01 nSv y−1 (average 19.41 nSv y−1).


  • Experimental investigation of commercially available lead composite aprons used for diagnostic X-rays

    by Hany A. Shousha, N. Rabie, G. M. Hassan

    One of the principal diagnostic methods used in all fields of medical services is radiographic examination. To keep the radiation dose received by hospital personnel under normal working conditions as low as reasonably achievable, lead composite apron shields are provided as valuable aids. Intensive use of these accessories could lead to softening and surface defects due to poor handling and being worn-out over time, giving rise to multiple defects across the entire apron. Without routine control, these lead aprons will, within time, contribute significantly to the over-radiation burden to the wearer. However, local defects are highly likely to lead to gross changes in the radiation dose received by the wearer. For this reason, we evaluate the exposure dose resulting from diagnostic X-ray radiation during different imaging procedures. In this study, we used TLD LiF-700 chips to measure the attenuation percentage for four groups of commercial lead composite aprons and to calculate the effective doses to different organs during diagnostic radiological procedures. The results show the importance of lead composite aprons in minimizing effective doses, and the attenuation percentage varied for different vendors; this is due to variations in the constituent material. The average attenuation for lead composite aprons varies from 93.3% to 96.7%, and the average attenuation (%)/weight varies from 16.7% to 20.5%. Acceptance testing of lead composite aprons is essential to ensure that lead composite aprons meet their manufacturers’ specifications and provide the necessary radiation protection for their intended use. The combined and expanded uncertainties accompanying these measurements are 2.78% and 5.57%, respectively.


  • Dosimetric study of the effective doses resulting during dental X-ray and panoramic radiography

    by Hany A. Shousha, A. I. Abd-El Hafez, Fawzia Ahmad

    The panoramic image is one of the most commonly used radiographic examinations in dentistry, owing to its low dose and large area for evaluation, including bone and teeth in the same image. Although digital images are usually reported to deliver a lower radiation dose to the patient, conventional images are still available, especially in countries where digital systems are not widely economically available. Dentists should weigh the benefits of dental radiographs against the consequences of increasing a patient's exposure to radiation, the effects of which accumulate from multiple sources over time. The “as low as reasonably achievable” principle should be followed to minimize the exposure to radiation. The purpose of this investigation is to measure the absorbed radiation doses at 12 anatomical sites of a Rando-phantom and calculate the effective doses result from a full-mouth survey and panoramic radiography. Organ-absorbed doses are measured using thermoluminescent dosimeters (TLD 100) and effective organ doses (μ Sv) are estimated according to the International Commission on Radiological Protection in 2007. The total effective dose results from the panoramic imaging system have so far been below those obtained using the full-mouth survey technique used in intra-oral radiographic examination.


  • Measurement of doses to the extremities of nuclear medicine staff

    by Hany A. Shousha, Hamed Farag, Ramadan A. Hassan

    Medical uses of ionizing radiation now represent>95% of all man-made radiation exposure, and is the largest single radiation source after natural background radiation. Therefore, it is important to quantify the amount of radiation received by occupational individuals to optimize the working conditions for staff, and further, to compare doses in different departments to ensure compatibility with the recommended standards. For some groups working with unsealed sources in nuclear medicine units, the hands are more heavily exposed to ionizing radiation than the rest of the body. A personal dosimetry service runs extensively in Egypt. But doses to extremities have not been measured to a wide extent. The purpose of this study was to investigate the equivalent radiation doses to the fingers for five different nuclear medicine staff occupational groups for which heavy irradiation of the hands was suspected. Finger doses were measured for (1) nuclear medicine physicians, (2) technologists, (3) nurses and (4) physicists. The fifth group contains three technicians handling 131I, while the others handled 99mTc. Each staff member working with the radioactive material wore two thermoluminescent dosimeters (TLDs) during the whole testing period, which lasted from 1 to 4 weeks. Staff performed their work on a regular basis throughout the month, and mean annual doses were calculated for these groups. Results showed that the mean equivalent doses to the fingers of technologist, nurse and physicist groups were 30.24±14.5, 30.37±17.5 and 16.3±7.7 μSv/GBq, respectively. Equivalent doses for the physicians could not be calculated per unit of activity because they did not handle the radiopharmaceuticals directly. Their doses were reported in millisieverts (mSv) that accumulated in one week. Similarly, the dose to the fingers of individuals in Group 5 was estimated to be 126.13±38.2 μSv/GBq. The maximum average finger dose, in this study, was noted in the technologists who handled therapeutic 131I (2.5 mSv). In conclusion, the maximum expected annual dose to extremities is less than the annual limit (500 mSv/y).


  • Absorbed photon dose measurement and calculation for some patient organs examined by computed tomography

    by Hany A. Shousha

    Patient doses from computed tomography (CT) examinations are usually expressed in terms of dose index, organ doses, and effective dose. The CT dose index (CTDI) can be measured free-in-air or in a CT dosimetry phantom. Organ doses can be measured directly in anthropomorphic Rando phantoms using thermoluminescent detectors. Organ doses can also be calculated by the Monte Carlo method utilizing measured CTDI values. In this work, organ doses were assessed for three main CT examinations: head, chest, and abdomen, using the different mentioned methods. Results of directly measured doses were compared with calculated doses for different organs in the study, and also compared with published international studies.