Amber J. Gislason-Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Amber J. Gislason-Lee has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Andrew G. Davies
Division of Medical Physics, University of Leeds, Room 8.001 Worsley Building, Clarendon Way, Leeds LS2 9JT, UK
3 shared publicationsArnold R. Cowen
Division of Medical Physics, University of Leeds, Room 8.001 Worsley Building, Clarendon Way, Leeds LS2 9JT, UK
3 shared publicationsCatherine McMillan
LXi Research, Division of Medical Physics, University of Leeds, Worsley Building, Clarendon Way, Leeds LS2 9JT, United Kingdom
1 shared publicationJanet Moore
Leeds General Infirmary, Great George Street, Leeds LS1 3EX, UK
1 shared publicationMichael Lupton
Leeds General Infirmary, Great George Street, Leeds LS1 3EX, UK
1 shared publicationMohan Sivananthan
Leeds General Infirmary, Great George Street, Leeds LS1 3EX, UK
1 shared publication
Latest Publications
- 20 February 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 162 (4) , 597-604
Does the use of additional X-ray beam filtration during cine acquisition reduce clinical image quality and effective dose in cardiac interventional imaging?
The impact of spectral filtration in digital (‘cine’) acquisition was investigated using a flat panel cardiac interventional X-ray imaging system. A 0.1-mm copper (Cu) and 1.0-mm aluminium (Al) filter added to the standard acquisition mode created the filtered mode for comparison. Image sequences of 35 patients were acquired, a double-blind subjective image quality assessment was completed and dose–area product (DAP) rates were calculated. Entrance surface dose (ESD) and effective dose (E) rates were determined for 20- and 30-cm phantoms. Phantom ESD fell by 28 and 41 % and E by 1 and 0.7 %, for the 20- and 30-cm phantoms, respectively, when using the filtration. Patient DAP rates fell by 43 % with no statistically significant difference in clinical image quality. Adding 0.1-mm Cu and 1.0-mm Al filtration in acquisition substantially reduces patient ESD and DAP, with no significant change in E or clinical image quality.
- 20 February 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 162 (4) , 597-604
Does the use of additional X-ray beam filtration during cine acquisition reduce clinical image quality and effective dose in cardiac interventional imaging?
The impact of spectral filtration in digital (‘cine’) acquisition was investigated using a flat panel cardiac interventional X-ray imaging system. A 0.1-mm copper (Cu) and 1.0-mm aluminium (Al) filter added to the standard acquisition mode created the filtered mode for comparison. Image sequences of 35 patients were acquired, a double-blind subjective image quality assessment was completed and dose–area product (DAP) rates were calculated. Entrance surface dose (ESD) and effective dose (E) rates were determined for 20- and 30-cm phantoms. Phantom ESD fell by 28 and 41 % and E by 1 and 0.7 %, for the 20- and 30-cm phantoms, respectively, when using the filtration. Patient DAP rates fell by 43 % with no statistically significant difference in clinical image quality. Adding 0.1-mm Cu and 1.0-mm Al filtration in acquisition substantially reduces patient ESD and DAP, with no significant change in E or clinical image quality.
- 13 August 2013
- Published by Wiley in Medical Physics
- Vol. 40 (9) , 091911
Dose optimization in cardiac x‐ray imaging
Purpose:: The aim of this research was to optimize x‐ray image quality to dose ratios in the cardiac catheterization laboratory. This study examined independently the effects of peak x‐ray tube voltage (kVp), copper (Cu), and gadolinium (Gd) x‐ray beam filtration on the image quality to radiation dose balance for adult patient sizes.Methods:: Image sequences of polymethyl methacrylate (PMMA) phantoms representing two adult patient sizes were captured using a modern flat panel detector based x‐ray imaging system. Tin and copper test details were used to simulate iodine‐based contrast medium and stents/guide wires respectively, which are used in clinical procedures. Noise measurement for a flat field image and test detail contrast were used to calculate the contrast to noise ratio (CNR). Entrance surface dose (ESD) and effective dose measurements were obtained to calculate the figure of merit (FOM), CNR2/dose. This FOM determined the dose efficiency of x‐ray spectra investigated. Images were captured with 0.0, 0.1, 0.25, 0.4, and 0.9 mm Cu filtration and with a range of gadolinium oxysulphide (Gd2O2S) filtration.Results:: Optimum x‐ray spectra were the same for the tin and copper test details. Lower peak tube voltages were generally favored. For the 20 cm phantom, using 2 Lanex Fast Back Gd2O2S screens as x‐ray filtration at 65 kVp provided the highest FOM considering ESD and effective dose. Considering ESD, this FOM was only marginally larger than that from using 0.4 mm Cu at 65 kVp. For the 30 cm phantom, using 0.25 mm copper filtration at 80 kVp was most optimal; considering effective dose the FOM was highest with no filtration at 65 kVp.Conclusions:: These settings, adjusted for x‐ray tube loading limits and clinically acceptable image quality, should provide a useful option for optimizing patient dose to image quality in cardiac x‐ray imaging. The same optimal x‐ray beam spectra were found for both the tin and copper details, suggesting that iodine contrast based imaging and visualization of interventional devices could potentially be optimized for dose using similar x‐ray beam spectra.
- 13 August 2013
- Published by Wiley in Medical Physics
- Vol. 40 (9) , 091911
Dose optimization in cardiac x‐ray imaging
Purpose:: The aim of this research was to optimize x‐ray image quality to dose ratios in the cardiac catheterization laboratory. This study examined independently the effects of peak x‐ray tube voltage (kVp), copper (Cu), and gadolinium (Gd) x‐ray beam filtration on the image quality to radiation dose balance for adult patient sizes.Methods:: Image sequences of polymethyl methacrylate (PMMA) phantoms representing two adult patient sizes were captured using a modern flat panel detector based x‐ray imaging system. Tin and copper test details were used to simulate iodine‐based contrast medium and stents/guide wires respectively, which are used in clinical procedures. Noise measurement for a flat field image and test detail contrast were used to calculate the contrast to noise ratio (CNR). Entrance surface dose (ESD) and effective dose measurements were obtained to calculate the figure of merit (FOM), CNR2/dose. This FOM determined the dose efficiency of x‐ray spectra investigated. Images were captured with 0.0, 0.1, 0.25, 0.4, and 0.9 mm Cu filtration and with a range of gadolinium oxysulphide (Gd2O2S) filtration.Results:: Optimum x‐ray spectra were the same for the tin and copper test details. Lower peak tube voltages were generally favored. For the 20 cm phantom, using 2 Lanex Fast Back Gd2O2S screens as x‐ray filtration at 65 kVp provided the highest FOM considering ESD and effective dose. Considering ESD, this FOM was only marginally larger than that from using 0.4 mm Cu at 65 kVp. For the 30 cm phantom, using 0.25 mm copper filtration at 80 kVp was most optimal; considering effective dose the FOM was highest with no filtration at 65 kVp.Conclusions:: These settings, adjusted for x‐ray tube loading limits and clinically acceptable image quality, should provide a useful option for optimizing patient dose to image quality in cardiac x‐ray imaging. The same optimal x‐ray beam spectra were found for both the tin and copper details, suggesting that iodine contrast based imaging and visualization of interventional devices could potentially be optimized for dose using similar x‐ray beam spectra.
- 16 September 2010
- Published by Wiley in Medical Physics
- Vol. 37 (10) , 5258-5269
Dose optimization in pediatric cardiac x‐ray imaging
Purpose: The aim of this research was to explore x‐ray beam parameters with intent to optimize pediatric x‐ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x‐ray tube voltage (kVp) and of copper (Cu) x‐ray beam filtration independently on the image quality to dose balance for pediatric patient sizes. The impact of antiscatter grid removal on the image quality to dose balance was also investigated.Methods: Image sequences of polymethyl methacrylate phantoms approximating chest sizes typical of pediatric patients were captured using a modern flat‐panel receptor based x‐ray imaging system. Tin was used to simulate iodine‐based contrast medium used in clinical procedures. Measurements of tin detail contrast and flat field image noise provided the contrast to noise ratio. Entrance surface dose (ESD) and effective dose (E) measurements were obtained to calculate the figure of merit (FOM),, which evaluated the dose efficiency of the x‐ray parameters investigated. The kVp, tube current (mA), and pulse duration were set manually by overriding the system's automatic dose control mechanisms. Images were captured with 0, 0.1, 0.25, 0.4, and 0.9 mm added Cu filtration, for 50, 55, 60, 65, and 70 kVp with the antiscatter grid in place, and then with it removed.Results: For a given phantom thickness, as the Cu filter thickness was increased, lower kVp was favored. Examining kVp alone, lower values were generally favored, more so for thinner phantoms. Considering ESD, the 8.5 cm phantom had the highest FOM at 50 kVp using 0.4 mm of Cu filtration. The 12 cm phantom had the highest FOM at 55 kVp using 0.9 mm Cu, and the 16 cm phantom had highest FOM at 55 kVp using 0.4 mm Cu. With regard to E, the 8.5 and 12 cm phantoms had the highest FOM at 50 kVp using 0.4 mm of Cu filtration, and the 16 cm phantom had the highest FOM at 50 kVp using 0.25 mm Cu. Antiscatter grid removal improved the FOM for a given set of x‐ray conditions. Under aforesaid optimal settings, the 8.5 cm phantom FOM improved by 24% and 33% for ESD and E, respectively. Corresponding improvements were 26% and 24% for the 12 cm phantom and 6% and 15% for the 16 cm phantom.Conclusions: For pediatric patients, using 0.25–0.9 mm Cu filtration in the x‐ray beam while maintaining 50–55 kVp, depending on patient size, provided optimal x‐ray image quality to dose ratios. These settings, adjusted for x‐ray tube loading limits and clinically acceptable image quality, should provide a useful strategy for optimizing iodine contrast agent based cardiac x‐ray imaging. Removing the antiscatter grid improved the FOM for the 8.5 and 12 cm phantoms, therefore grid removal is recommended for younger children. Improvement for the 16 cm phantom declined into the estimated margin of error for the FOM; the need for grid removal for older children would depend on practical feasibility in the clinical environment.
- 16 September 2010
- Published by Wiley in Medical Physics
- Vol. 37 (10) , 5258-5269
Dose optimization in pediatric cardiac x‐ray imaging
Purpose: The aim of this research was to explore x‐ray beam parameters with intent to optimize pediatric x‐ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x‐ray tube voltage (kVp) and of copper (Cu) x‐ray beam filtration independently on the image quality to dose balance for pediatric patient sizes. The impact of antiscatter grid removal on the image quality to dose balance was also investigated.Methods: Image sequences of polymethyl methacrylate phantoms approximating chest sizes typical of pediatric patients were captured using a modern flat‐panel receptor based x‐ray imaging system. Tin was used to simulate iodine‐based contrast medium used in clinical procedures. Measurements of tin detail contrast and flat field image noise provided the contrast to noise ratio. Entrance surface dose (ESD) and effective dose (E) measurements were obtained to calculate the figure of merit (FOM),, which evaluated the dose efficiency of the x‐ray parameters investigated. The kVp, tube current (mA), and pulse duration were set manually by overriding the system's automatic dose control mechanisms. Images were captured with 0, 0.1, 0.25, 0.4, and 0.9 mm added Cu filtration, for 50, 55, 60, 65, and 70 kVp with the antiscatter grid in place, and then with it removed.Results: For a given phantom thickness, as the Cu filter thickness was increased, lower kVp was favored. Examining kVp alone, lower values were generally favored, more so for thinner phantoms. Considering ESD, the 8.5 cm phantom had the highest FOM at 50 kVp using 0.4 mm of Cu filtration. The 12 cm phantom had the highest FOM at 55 kVp using 0.9 mm Cu, and the 16 cm phantom had highest FOM at 55 kVp using 0.4 mm Cu. With regard to E, the 8.5 and 12 cm phantoms had the highest FOM at 50 kVp using 0.4 mm of Cu filtration, and the 16 cm phantom had the highest FOM at 50 kVp using 0.25 mm Cu. Antiscatter grid removal improved the FOM for a given set of x‐ray conditions. Under aforesaid optimal settings, the 8.5 cm phantom FOM improved by 24% and 33% for ESD and E, respectively. Corresponding improvements were 26% and 24% for the 12 cm phantom and 6% and 15% for the 16 cm phantom.Conclusions: For pediatric patients, using 0.25–0.9 mm Cu filtration in the x‐ray beam while maintaining 50–55 kVp, depending on patient size, provided optimal x‐ray image quality to dose ratios. These settings, adjusted for x‐ray tube loading limits and clinically acceptable image quality, should provide a useful strategy for optimizing iodine contrast agent based cardiac x‐ray imaging. Removing the antiscatter grid improved the FOM for the 8.5 and 12 cm phantoms, therefore grid removal is recommended for younger children. Improvement for the 16 cm phantom declined into the estimated margin of error for the FOM; the need for grid removal for older children would depend on practical feasibility in the clinical environment.