Fujio Araki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fujio Araki has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
Takeshi Ohno
Department of Health Sciences, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan
12 shared publications- Takeshi Ohno
Faculty of Life Sciences Kumamoto University Kumamoto Japan
8 shared publications Kozo Kumagai
4 shared publicationsTakahiro Kubota
Kokura Memorial Hospital, 3-2-1 Asano, Kokura, Fukuoka, Japan
4 shared publicationsKento Hoshida
Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, Japan
3 shared publicationsRyuki Tanabe
Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Chuo-ku, Kumamoto 862-0976, Japan
3 shared publications
Latest Publications
- 25 February 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 194, 110036
Monte Carlo study of small-field dosimetry for an ELEKTA Unity MR-Linac system
- 25 February 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 194, 110036
Monte Carlo study of small-field dosimetry for an ELEKTA Unity MR-Linac system
- 1 November 2021
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 188
Determination of an ionization chamber response using quality index for kilovoltage x-ray beams
- 1 November 2021
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 188
Determination of an ionization chamber response using quality index for kilovoltage x-ray beams
- 1 September 2021
- Published by Elsevier in Physica Medica
- Vol. 89, 176-181
Real-time estimation of surface dose based on incident air kerma in diagnostic radiology
- 1 September 2021
- Published by Elsevier in Physica Medica
- Vol. 89, 176-181
Real-time estimation of surface dose based on incident air kerma in diagnostic radiology
- 1 June 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (2) , 124-131
SURFACE DOSE ESTIMATION BY A KAP METER FOR KILOVOLTAGE X-RAY BEAMS
This study aims to estimate the entrance surface dose (ESD) of a water phantom for kilovoltage x-ray beams using an air kerma area product meter (KAP meter) equipped in an x-ray unit. The KAP meter was calibrated in terms of the ESD determined by a plane-parallel ionization chamber based on a 60Co absorbed dose-to-water calibration coefficient, ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$. The ESD measured using the KAP meter was verified by comparing it with that estimated by the air kerma calibration coefficient, NK, for x-ray beam qualities. The ratio of ESDs based on ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$ and NK was 1.003 on average and independent of the beam quality. The ESD by the KAP meter was an agreement within ±1.5% with that measured using the plane-parallel chamber for 10 × 10–30 × 30 cm2 fields with a source-surface distance of 75–150 cm. It was possible to estimate the ESD directly in a water phantom for x-ray beams without correction factors compared to the existing air kerma calibration, using a KAP meter calibrated based on ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$.- 1 June 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (2) , 124-131
SURFACE DOSE ESTIMATION BY A KAP METER FOR KILOVOLTAGE X-RAY BEAMS
This study aims to estimate the entrance surface dose (ESD) of a water phantom for kilovoltage x-ray beams using an air kerma area product meter (KAP meter) equipped in an x-ray unit. The KAP meter was calibrated in terms of the ESD determined by a plane-parallel ionization chamber based on a 60Co absorbed dose-to-water calibration coefficient, ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$. The ESD measured using the KAP meter was verified by comparing it with that estimated by the air kerma calibration coefficient, NK, for x-ray beam qualities. The ratio of ESDs based on ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$ and NK was 1.003 on average and independent of the beam quality. The ESD by the KAP meter was an agreement within ±1.5% with that measured using the plane-parallel chamber for 10 × 10–30 × 30 cm2 fields with a source-surface distance of 75–150 cm. It was possible to estimate the ESD directly in a water phantom for x-ray beams without correction factors compared to the existing air kerma calibration, using a KAP meter calibrated based on ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$.- 1 June 2021
- Published by Elsevier in Physica Medica
- Vol. 86, 19-30
Monte Carlo study of dosimetric impact of gadolinium contrast medium in transverse field MR-Linac system
- 1 June 2021
- Published by Elsevier in Physica Medica
- Vol. 86, 19-30
Monte Carlo study of dosimetric impact of gadolinium contrast medium in transverse field MR-Linac system
- 1 April 2021
- Published by Elsevier in Physica Medica
- Vol. 84, 198-204
Determination of the surface dose of a water phantom using a semiconductor detector for diagnostic kilovoltage x-ray beams
- 1 April 2021
- Published by Elsevier in Physica Medica
- Vol. 84, 198-204
Determination of the surface dose of a water phantom using a semiconductor detector for diagnostic kilovoltage x-ray beams
- 1 April 2021
- Published by Elsevier in Physica Medica
- Vol. 84, 101-108
Monte Carlo determination of a nanoDot OSLD response using quality index for diagnostic kilovoltage X-ray beams
- 1 April 2021
- Published by Elsevier in Physica Medica
- Vol. 84, 101-108
Monte Carlo determination of a nanoDot OSLD response using quality index for diagnostic kilovoltage X-ray beams
- 1 February 2021
- Published by Elsevier in Physica Medica
- Vol. 82, 144-149
Energy response of radiophotoluminescent glass dosimeter for diagnostic kilovoltage x-ray beams
- 1 February 2021
- Published by Elsevier in Physica Medica
- Vol. 82, 144-149
Energy response of radiophotoluminescent glass dosimeter for diagnostic kilovoltage x-ray beams
- 25 November 2020
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 40 (4) , 1429-1443
Indices for the evaluation of glandular dose heterogeneity in full-field digital mammography
This study aims to evaluate the indices of glandular dose heterogeneity in full-field digital mammography. The distributions of GD in a breast phantom with a skin layer of 4 mm were determined using the Monte Carlo method with simulated x-ray fluence spectra. First, the GD to air kerma (GD/ K air ) volume histogram was obtained from the GD distributions, which were indicated by the glandular volume (%) as a function of GD/ K air . The GD indices, namely, the maximum glandular dose (GD 2% ) and glandular volume percentage (%) receiving at least the mean glandular dose (MGD) ( V MGD ) were calculated from the GD/ K air volume histogram. Next, the scatter plots of GD 2% /MGD and V MGD were drawn as functions of the normalised mean glandular dose (DgN). Finally, (GD 2% ) i and ( V MGD ) i were obtained from the relationship between the GD indices and DgN for 596 clinical irradiation cases based on individual irradiation conditions. The values of GD 2% /MGD were more affected by breast thickness than glandularity and tube voltage, and they decreased according to the power law of DgN for all the target/filter combinations. The values of V MGD were proportional to DgN and decreased with increase in the compressed breast thickness. The values of (MGD) i and (GD 2% ) i for 596 clinical irradiation cases were estimated to range from 0.6–3.0 mGy to 1.1–7.0 mGy, respectively, and ( V MGD ) i was in the range 32%−48%. (GD 2% ) i and ( V MGD ) i are mainly affected by breast thickness. These indices are useful for the evaluation of glandular dose heterogeneity in mammography.
- 25 November 2020
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 40 (4) , 1429-1443
Indices for the evaluation of glandular dose heterogeneity in full-field digital mammography
This study aims to evaluate the indices of glandular dose heterogeneity in full-field digital mammography. The distributions of GD in a breast phantom with a skin layer of 4 mm were determined using the Monte Carlo method with simulated x-ray fluence spectra. First, the GD to air kerma (GD/ K air ) volume histogram was obtained from the GD distributions, which were indicated by the glandular volume (%) as a function of GD/ K air . The GD indices, namely, the maximum glandular dose (GD 2% ) and glandular volume percentage (%) receiving at least the mean glandular dose (MGD) ( V MGD ) were calculated from the GD/ K air volume histogram. Next, the scatter plots of GD 2% /MGD and V MGD were drawn as functions of the normalised mean glandular dose (DgN). Finally, (GD 2% ) i and ( V MGD ) i were obtained from the relationship between the GD indices and DgN for 596 clinical irradiation cases based on individual irradiation conditions. The values of GD 2% /MGD were more affected by breast thickness than glandularity and tube voltage, and they decreased according to the power law of DgN for all the target/filter combinations. The values of V MGD were proportional to DgN and decreased with increase in the compressed breast thickness. The values of (MGD) i and (GD 2% ) i for 596 clinical irradiation cases were estimated to range from 0.6–3.0 mGy to 1.1–7.0 mGy, respectively, and ( V MGD ) i was in the range 32%−48%. (GD 2% ) i and ( V MGD ) i are mainly affected by breast thickness. These indices are useful for the evaluation of glandular dose heterogeneity in mammography.
- 1 September 2020
- Published by Elsevier in Physica Medica
- Vol. 77, 48-53
Determination of backscatter factors based on the quality index for diagnostic kilovoltage x-ray beams
- 1 September 2020
- Published by Elsevier in Physica Medica
- Vol. 77, 48-53
Determination of backscatter factors based on the quality index for diagnostic kilovoltage x-ray beams