Alain Farron
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alain Farron has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Terrier
Laboratory of Biomechanical Orthopedics, Ecole Polytechnique Fédérale de Lausanne, Switzerland
3 shared publications - Alexandre Terrier
Department of Orthopedics and Traumatology, University Hospital Centre and University of Lausanne (CHUV), Switzerland
3 shared publications F. Merlini
Laboratory of Biomechanical Orthopedics , EPFL , Lausanne, Switzerland
3 shared publications- Fabio Becce
Lausanne University Hospital
3 shared publications A Reist
2 shared publications- Kamiar Aminian
Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
2 shared publications
Latest Publications
- Open Access
- 17 October 2024
- Published by BMJ in BMJ Case Reports
- Vol. 17 (10) , e258334
Peripheral neuropathy following monkeypox infection: an unexpected diagnosis of Parsonage-Turner syndrome
Parsonage-Turner syndrome following monkeypox infection is a rare form of peripheral neuropathy seen in orthopaedic practice and described only once in the literature. We present the case of a man in his 30s with severe shoulder pain and subsequent amyotrophy 2 weeks after monkeypox infection. Our report encompasses the initial findings, radiographic examinations and follow-up over a 6-month period. To confirm the diagnosis, MRI and electrostimulation conduction studies were conducted, highlighting their importance as valuable diagnostic tools in conjunction with a thorough physical examination. Supportive treatment, including physical therapy and pain management, forms the cornerstone of management, while surgical intervention is reserved for refractory cases or when mechanical complications arise. Prognosis varies among individuals. This case report expands the understanding of neurological complications of monkeypox infection. Clinicians should include Parsonage-Turner syndrome in their differential diagnosis for patients presenting with symptoms of peripheral brachial plexus neuropathy following viral infections, including monkeypox.
- 17 October 2024
- Published by BMJ in BMJ Case Reports
- Vol. 17 (10) , e258334
Open AccessPeripheral neuropathy following monkeypox infection: an unexpected diagnosis of Parsonage-Turner syndrome
Parsonage-Turner syndrome following monkeypox infection is a rare form of peripheral neuropathy seen in orthopaedic practice and described only once in the literature. We present the case of a man in his 30s with severe shoulder pain and subsequent amyotrophy 2 weeks after monkeypox infection. Our report encompasses the initial findings, radiographic examinations and follow-up over a 6-month period. To confirm the diagnosis, MRI and electrostimulation conduction studies were conducted, highlighting their importance as valuable diagnostic tools in conjunction with a thorough physical examination. Supportive treatment, including physical therapy and pain management, forms the cornerstone of management, while surgical intervention is reserved for refractory cases or when mechanical complications arise. Prognosis varies among individuals. This case report expands the understanding of neurological complications of monkeypox infection. Clinicians should include Parsonage-Turner syndrome in their differential diagnosis for patients presenting with symptoms of peripheral brachial plexus neuropathy following viral infections, including monkeypox.
- Open Access
- 12 January 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (2) , 351
Association of the Posterior Acromion Extension with Glenoid Retroversion: A CT Study in Normal and Osteoarthritic Shoulders
Posterior eccentric glenoid wear is associated with higher complication rates after shoulder arthroplasty. The recently reported association between the acromion shape and glenoid retroversion in both normal and osteoarthritic shoulders remains controversial. The three-dimensional coordinates of the angulus acromialis (AA) and acromioclavicular joint were examined in the scapular coordinate system. Four acromion angles were defined from these two acromion landmarks: the acromion posterior angle (APA), acromion tilt angle (ATA), acromion length angle (ALA), and acromion axial tilt angle (AXA). Shoulder computed tomography scans of 112 normal scapulae and 125 patients with primary glenohumeral osteoarthritis were analyzed with simple and stepwise multiple linear regressions between all morphological acromion parameters and glenoid retroversion. In normal scapulae, the glenoid retroversion angle was most strongly correlated with the posterior extension of the AA (R2 = 0.48, p < 0.0001), which can be conveniently characterized by the APA. Combining the APA with the ALA and ATA helped slightly improve the correlation (R2 = 0.55, p < 0.0001), but adding the AXA did not. In osteoarthritic scapulae, a critical APA > 15 degrees was found to best identify glenoids with a critical retroversion angle > 8 degrees. The APA is more strongly associated with the glenoid retroversion angle in normal than primary osteoarthritic scapulae.
- 12 January 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (2) , 351
Open AccessAssociation of the Posterior Acromion Extension with Glenoid Retroversion: A CT Study in Normal and Osteoarthritic Shoulders
Posterior eccentric glenoid wear is associated with higher complication rates after shoulder arthroplasty. The recently reported association between the acromion shape and glenoid retroversion in both normal and osteoarthritic shoulders remains controversial. The three-dimensional coordinates of the angulus acromialis (AA) and acromioclavicular joint were examined in the scapular coordinate system. Four acromion angles were defined from these two acromion landmarks: the acromion posterior angle (APA), acromion tilt angle (ATA), acromion length angle (ALA), and acromion axial tilt angle (AXA). Shoulder computed tomography scans of 112 normal scapulae and 125 patients with primary glenohumeral osteoarthritis were analyzed with simple and stepwise multiple linear regressions between all morphological acromion parameters and glenoid retroversion. In normal scapulae, the glenoid retroversion angle was most strongly correlated with the posterior extension of the AA (R2 = 0.48, p < 0.0001), which can be conveniently characterized by the APA. Combining the APA with the ALA and ATA helped slightly improve the correlation (R2 = 0.55, p < 0.0001), but adding the AXA did not. In osteoarthritic scapulae, a critical APA > 15 degrees was found to best identify glenoids with a critical retroversion angle > 8 degrees. The APA is more strongly associated with the glenoid retroversion angle in normal than primary osteoarthritic scapulae.
- Open Access
- 1 October 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (1)
A Robotic Glenohumeral Simulator for Investigating Prosthetic Implant Subluxation
Total shoulder arthroplasty (TSA) is an effective treatment for glenohumeral (GH) osteoarthritis. However, it still suffers from a substantial rate of mechanical failure, which may be related to cyclic off-center loading of the humeral head on the glenoid. In this work, we present the design and evaluation of a GH joint robotic simulator developed to study GH translations. This five-degree-of-freedom robot was designed to replicate the rotations (±40 deg, accuracy 0.5 deg) and three-dimensional (3D) forces (up to 2 kN, with a 1% error settling time of 0.6 s) that the humeral implant exerts on the glenoid implant. We tested the performances of the simulator using force patterns measured in real patients. Moreover, we evaluated the effect of different orientations of the glenoid implant on joint stability. When simulating realistic dynamic forces and implant orientations, the simulator was able to reproduce stable behavior by measuring the translations of the humeral head of less than 24 mm with respect to the glenoid implant. Simulation with quasi-static forces showed dislocation in extreme ranges of implant orientation. The robotic GH simulator presented here was able to reproduce physiological GH forces and may therefore be used to further evaluate the effects of glenoid implant design and orientation on joint stability.
- 1 October 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (1)
Open AccessA Robotic Glenohumeral Simulator for Investigating Prosthetic Implant Subluxation
Total shoulder arthroplasty (TSA) is an effective treatment for glenohumeral (GH) osteoarthritis. However, it still suffers from a substantial rate of mechanical failure, which may be related to cyclic off-center loading of the humeral head on the glenoid. In this work, we present the design and evaluation of a GH joint robotic simulator developed to study GH translations. This five-degree-of-freedom robot was designed to replicate the rotations (±40 deg, accuracy 0.5 deg) and three-dimensional (3D) forces (up to 2 kN, with a 1% error settling time of 0.6 s) that the humeral implant exerts on the glenoid implant. We tested the performances of the simulator using force patterns measured in real patients. Moreover, we evaluated the effect of different orientations of the glenoid implant on joint stability. When simulating realistic dynamic forces and implant orientations, the simulator was able to reproduce stable behavior by measuring the translations of the humeral head of less than 24 mm with respect to the glenoid implant. Simulation with quasi-static forces showed dislocation in extreme ranges of implant orientation. The robotic GH simulator presented here was able to reproduce physiological GH forces and may therefore be used to further evaluate the effects of glenoid implant design and orientation on joint stability.
- Open Access
Measurement Properties of the Smartphone-Based B-B Score in Current Shoulder Pathologies
This study is aimed at the determination of the measurement properties of the shoulder function B-B Score measured with a smartphone. This score measures the symmetry between sides of a power-related metric for two selected movements, with 100% representing perfect symmetry. Twenty healthy participants, 20 patients with rotator cuff conditions, 23 with fractures, 22 with capsulitis, and 23 with shoulder instabilities were measured twice across a six-month interval using the B-B Score and shoulder function questionnaires. The discriminative power, responsiveness, diagnostic power, concurrent validity, minimal detectable change (MDC), minimal clinically important improvement (MCII), and patient acceptable symptom state (PASS) were evaluated. Significant differences with the control group and significant baseline—six-month differences were found for the rotator cuff condition, fracture, and capsulitis patient groups. The B-B Score was responsive and demonstrated excellent diagnostic power, except for shoulder instability. The correlations with clinical scores were generally moderate to high, but lower for instability. The MDC was 18.1%, the MCII was 25.2%, and the PASS was 77.6. No floor effect was observed. The B-B Score demonstrated excellent measurement properties in populations with rotator cuff conditions, proximal humerus fractures, and capsulitis, and can thus be used as a routine test to evaluate those patients.
Open AccessMeasurement Properties of the Smartphone-Based B-B Score in Current Shoulder Pathologies
This study is aimed at the determination of the measurement properties of the shoulder function B-B Score measured with a smartphone. This score measures the symmetry between sides of a power-related metric for two selected movements, with 100% representing perfect symmetry. Twenty healthy participants, 20 patients with rotator cuff conditions, 23 with fractures, 22 with capsulitis, and 23 with shoulder instabilities were measured twice across a six-month interval using the B-B Score and shoulder function questionnaires. The discriminative power, responsiveness, diagnostic power, concurrent validity, minimal detectable change (MDC), minimal clinically important improvement (MCII), and patient acceptable symptom state (PASS) were evaluated. Significant differences with the control group and significant baseline—six-month differences were found for the rotator cuff condition, fracture, and capsulitis patient groups. The B-B Score was responsive and demonstrated excellent diagnostic power, except for shoulder instability. The correlations with clinical scores were generally moderate to high, but lower for instability. The MDC was 18.1%, the MCII was 25.2%, and the PASS was 77.6. No floor effect was observed. The B-B Score demonstrated excellent measurement properties in populations with rotator cuff conditions, proximal humerus fractures, and capsulitis, and can thus be used as a routine test to evaluate those patients.
- 1 September 2014
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 100 (5) , 503-508
Complications of shoulder arthroplasty for osteoarthritis with posterior glenoid wear
- 1 September 2014
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 100 (5) , 503-508
Complications of shoulder arthroplasty for osteoarthritis with posterior glenoid wear
- 30 July 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (sup1) , 118-119
Impact of partial-thickness tears on supraspinatus tendon strain based on a finite element analysis
- 30 July 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (sup1) , 118-119
Impact of partial-thickness tears on supraspinatus tendon strain based on a finite element analysis
- 1 January 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (sup001) , 217-218
Shoulder arthroplasty: drawback of glenoid tilting
- 1 January 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (sup001) , 217-218
Shoulder arthroplasty: drawback of glenoid tilting
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40, S147-147
ROTATOR CUFF DEFICIENCY ASSOCIATED TO TOTAL SHOULDER ARTHOPLASTY
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40, S147-147
ROTATOR CUFF DEFICIENCY ASSOCIATED TO TOTAL SHOULDER ARTHOPLASTY
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40, S146-146
JOINT AND MUSCLES FORCES IN REVERSEDAND ANATOMIC SHOULDER PROSTHESES
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40, S146-146
JOINT AND MUSCLES FORCES IN REVERSEDAND ANATOMIC SHOULDER PROSTHESES
- 20 December 2006
- Vol. 2 (92) , 2913-7
[Indications to complementary radiological exams for pathologies of the shoulder].
Plain Xrays should stay in pole position for the evaluation of shoulder's pathologies. They allow frequently to make a diagnosis of the lesion. Indications to complementary exams are well established. CT-scan and MRI have to give responses to precise questions, which then will permit to manage the treatment. CT-scan allows to evaluate accurately bone structures. It is very useful for analysing complex fractures of the proximal humerus. It allows also to evaluate the amount of glenoid wear to correct before implanting a prosthesis. Arthro-MRI is used to study soft tissues, cartilage and bone. Therefore, it is the first choice exam to evaluate the rotator cuff tendons, as well as the labrum and ligaments in case of shoulder instability.
- 20 December 2006
- Vol. 2 (92) , 2913-7
[Indications to complementary radiological exams for pathologies of the shoulder].
Plain Xrays should stay in pole position for the evaluation of shoulder's pathologies. They allow frequently to make a diagnosis of the lesion. Indications to complementary exams are well established. CT-scan and MRI have to give responses to precise questions, which then will permit to manage the treatment. CT-scan allows to evaluate accurately bone structures. It is very useful for analysing complex fractures of the proximal humerus. It allows also to evaluate the amount of glenoid wear to correct before implanting a prosthesis. Arthro-MRI is used to study soft tissues, cartilage and bone. Therefore, it is the first choice exam to evaluate the rotator cuff tendons, as well as the labrum and ligaments in case of shoulder instability.