Maíra Marques Ribeiro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maíra Marques Ribeiro has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Adriana Cristina de Oliveira
Universidade Federal de Minas Gerais (UFMG)
2 shared publications - Evandro Watanabe
Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Brazil
2 shared publications - Brunela Pereira da Silva
Department of Engineering and Computing, State University of Santa Cruz
1 shared publication - Bélgica Andrade
Hospital Clínico San Borja Arriarán-Chile, Santiago 8360160, Chile
1 shared publication - Camila Quartim de Moraes Bruna
Universidade de São Paulo, Brazil; Universidade de São Paulo, Brazil
1 shared publication - Idalina Vieira Aoki
Polytechnic School, Universidade de São Paulo, Sao Paulo 05508-220, Sao Paulo, Brazil
1 shared publication
Latest Publications
- Open Access
Evaluation of the Presence of Biofilms in Corrosive Points in Surgical Instruments after Reprocessing
Corrosive surgical instruments are routinely observed in central sterile services departments around the world. In addition to other risks, they can harbor microorganisms in the form of biofilms. Thus, this study aimed to evaluate whether biofilms intentionally formed at corrosion points on surgical instruments are removable by manual and automated cleaning followed by sterilization. Laboratory experiments were performed where samples of corroded surgical instruments in use in practice were evaluated for biofilm presence using a scanning electron microscope. No biofilms were observed in the samples subjected to manual and automated cleaning, nor in the samples in which there was no intentional biofilm formation. Residual organic matter without the presence of microorganisms was observed.
Open AccessEvaluation of the Presence of Biofilms in Corrosive Points in Surgical Instruments after Reprocessing
Corrosive surgical instruments are routinely observed in central sterile services departments around the world. In addition to other risks, they can harbor microorganisms in the form of biofilms. Thus, this study aimed to evaluate whether biofilms intentionally formed at corrosion points on surgical instruments are removable by manual and automated cleaning followed by sterilization. Laboratory experiments were performed where samples of corroded surgical instruments in use in practice were evaluated for biofilm presence using a scanning electron microscope. No biofilms were observed in the samples subjected to manual and automated cleaning, nor in the samples in which there was no intentional biofilm formation. Residual organic matter without the presence of microorganisms was observed.
- 5 November 2019
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 41 (2) , 1-9
The polytetrafluoroethylene (PTFE) channel model of cyclic-buildup biofilm and traditional biofilm: The impact of friction, and detergent on cleaning and subsequent high-level disinfection
Objective: To evaluate the efficacy of detergent and friction on removal of traditional biofilm and cyclic-buildup biofilm (CBB) from polytetrafluoroethylene (PTFE) channels and to evaluate the efficacy of glutaraldehyde to kill residual bacteria after cleaning. Methods: PTFE channels were exposed to artificial test soil containing 108 CFU/mL of Pseudomonas aeruginosa and Enterococcus faecalis, followed by full cleaning and high-level disinfection (HLD) for five repeated rounds to establish CBB. For traditional biofilm, the HLD step was omitted. Cleaning with enzymatic and alkaline detergents, bristle brush, and Pull Thru channel cleaner were compared to a water flush only. Carbohydrate, protein, viable count, adenosine triphosphate (ATP) levels were analyzed and atomic force microscopy (AFM) was performed. Results: In the absence of friction, cleaning of traditional biofilm and CBB was not effective compared to the positive control (Dunn-Bonferroni tests; P > .05) regardless of the detergent used. ATP, protein, and carbohydrate analyses were unable to detect traditional biofilm or CBB. The AFM analysis showed that fixation resulted in CBB being smoother and more compact than traditional biofilm. Conclusion: Friction during the cleaning process was a critical parameter regardless of the detergent used for removal of either traditional biofilm or CBB. Glutaraldehyde effectively killed the remaining microorganisms regardless of the cleaning method used.
- 5 November 2019
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 41 (2) , 1-9
The polytetrafluoroethylene (PTFE) channel model of cyclic-buildup biofilm and traditional biofilm: The impact of friction, and detergent on cleaning and subsequent high-level disinfection
Objective: To evaluate the efficacy of detergent and friction on removal of traditional biofilm and cyclic-buildup biofilm (CBB) from polytetrafluoroethylene (PTFE) channels and to evaluate the efficacy of glutaraldehyde to kill residual bacteria after cleaning. Methods: PTFE channels were exposed to artificial test soil containing 108 CFU/mL of Pseudomonas aeruginosa and Enterococcus faecalis, followed by full cleaning and high-level disinfection (HLD) for five repeated rounds to establish CBB. For traditional biofilm, the HLD step was omitted. Cleaning with enzymatic and alkaline detergents, bristle brush, and Pull Thru channel cleaner were compared to a water flush only. Carbohydrate, protein, viable count, adenosine triphosphate (ATP) levels were analyzed and atomic force microscopy (AFM) was performed. Results: In the absence of friction, cleaning of traditional biofilm and CBB was not effective compared to the positive control (Dunn-Bonferroni tests; P > .05) regardless of the detergent used. ATP, protein, and carbohydrate analyses were unable to detect traditional biofilm or CBB. The AFM analysis showed that fixation resulted in CBB being smoother and more compact than traditional biofilm. Conclusion: Friction during the cleaning process was a critical parameter regardless of the detergent used for removal of either traditional biofilm or CBB. Glutaraldehyde effectively killed the remaining microorganisms regardless of the cleaning method used.
- Open Access
- 1 August 2015
- Published by FapUNIFESP (SciELO) in Revista Latino-Americana de Enfermagem
- Vol. 23 (4) , 741-752
Efficacy and effectiveness of alcohol in the disinfection of semi-critical materials: a systematic review
Objective: to assess the efficacy and the effectiveness of 60-80% alcohol (v/v) in the disinfection of semi-critical materials which were either previously cleaned or not.Method: studies obtained from BIREME, IBECS, MEDLINE, ScIELO, PubMed, Ask Medline web portals, and references from other studies. Criteria were created to assess the methodological quality of articles. Out of the 906 studies found, 14 have been included.Results: after materials were disinfected with alcohol, microorganisms were detected in 104/282 (36.9%) effectiveness tests and in 23/92 (25.0%) efficacy tests that were conducted. In the field studies, disinfection was not achieved for 74/218 (33.9%) of the products that were submitted to previous cleaning and for 30/64 (46.9%) of the ones which were not submitted to previous cleaning. In the experimental studies, alcohol disinfection was not efficacy in 11/30 (36.7%) and 12/62 (19.4%) of products, respectively. The studies were not found to have followed standardized methods.Conclusion: disinfection of semi-critical products with alcohol 70% - or in an approximate concentration - cannot be recommended to all health care products in an unrestricted way. However, according to the type of semi-critical product, disinfection can be attained with or without previous cleaning.
- 1 August 2015
- Published by FapUNIFESP (SciELO) in Revista Latino-Americana de Enfermagem
- Vol. 23 (4) , 741-752
Open AccessEfficacy and effectiveness of alcohol in the disinfection of semi-critical materials: a systematic review
Objective: to assess the efficacy and the effectiveness of 60-80% alcohol (v/v) in the disinfection of semi-critical materials which were either previously cleaned or not.Method: studies obtained from BIREME, IBECS, MEDLINE, ScIELO, PubMed, Ask Medline web portals, and references from other studies. Criteria were created to assess the methodological quality of articles. Out of the 906 studies found, 14 have been included.Results: after materials were disinfected with alcohol, microorganisms were detected in 104/282 (36.9%) effectiveness tests and in 23/92 (25.0%) efficacy tests that were conducted. In the field studies, disinfection was not achieved for 74/218 (33.9%) of the products that were submitted to previous cleaning and for 30/64 (46.9%) of the ones which were not submitted to previous cleaning. In the experimental studies, alcohol disinfection was not efficacy in 11/30 (36.7%) and 12/62 (19.4%) of products, respectively. The studies were not found to have followed standardized methods.Conclusion: disinfection of semi-critical products with alcohol 70% - or in an approximate concentration - cannot be recommended to all health care products in an unrestricted way. However, according to the type of semi-critical product, disinfection can be attained with or without previous cleaning.
- 1 March 2013
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 34 (3) , 309-312
Effectiveness of Flexible Gastrointestinal Endoscope Reprocessing
The practice of reprocessing endoscopes and its effectiveness was evaluated in 37 services. Contamination of at least 1 endoscope could be identified in 34 (91.6%) of 37 services. Bacteria, fungi, and/or mycobacteria were isolated from 84.6% (33/39) of the colonoscopes (110–32,000 colony-forming units [CFUs]/mL) and from 80.6% (50/62) of the gastroscopes (100–33,000 CFUs/mL). Not all services followed recommended guidelines. Therefore, patients who underwent gastrointestinal endoscopies were exposed to diverse pathogens.
- 1 March 2013
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 34 (3) , 309-312
Effectiveness of Flexible Gastrointestinal Endoscope Reprocessing
The practice of reprocessing endoscopes and its effectiveness was evaluated in 37 services. Contamination of at least 1 endoscope could be identified in 34 (91.6%) of 37 services. Bacteria, fungi, and/or mycobacteria were isolated from 84.6% (33/39) of the colonoscopes (110–32,000 colony-forming units [CFUs]/mL) and from 80.6% (50/62) of the gastroscopes (100–33,000 CFUs/mL). Not all services followed recommended guidelines. Therefore, patients who underwent gastrointestinal endoscopies were exposed to diverse pathogens.
- 1 December 2012
- Published by Elsevier in American Journal of Infection Control
- Vol. 40 (10) , 913-916
Analysis of the air/water channels of gastrointestinal endoscopies as a risk factor for the transmission of microorganisms among patients
- 1 December 2012
- Published by Elsevier in American Journal of Infection Control
- Vol. 40 (10) , 913-916
Analysis of the air/water channels of gastrointestinal endoscopies as a risk factor for the transmission of microorganisms among patients