Miroslav Polášek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Miroslav Polášek has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Petr Solich
Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Hradec Králové, Czech Republic
3 shared publications - Hana Sklenářová
Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Akademika Heyrovského 1203, 500 03 Hradec Králové, Czech Republic
2 shared publications Jitka Široká
Department of Analytical Chemistry Faculty of Pharmacy in Hradec Králové Charles University in Prague Heyrovského Hradec Králové Czech Republic
2 shared publicationsLuděk Jahodář
2 shared publicationsMarie Pospíšilová
Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University in Prague, Hradec Králové, Czech Republic
2 shared publicationsAndrea Martincová
Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University in Prague, Hradec Králové, Czech Republic
1 shared publication
Latest Publications
- 1 May 2014
- Published by Wiley in Electrophoresis
- Vol. 35 (17) , 2546-2549
Assay of urinary 8‐hydroxy‐2′‐deoxyguanosine by capillary electrophoresis with spectrophotometric detection using a high‐sensitivity detection cell and solid‐phase extraction
A sensitive capillary electrophoretic method featuring spectrophotometric detection using a commercial Z‐cell was devised for the assay of 8‐hydroxy‐2′‐deoxyguanosine (8OHdG) in human urine. Solid‐phase extraction (SPE) based on hydrophilic‐lipophilic‐balanced RP sorbent was utilized for urine sample pretreatment and analyte preconcentration. The separation was carried out in conventional fused‐silica capillaries employing a Z‐cell with hydrodynamic sample injection (at 50 mbar for 12 s). The BGE (pH* 9.2, adjusted with 1 M NaOH) contained 0.15 M boric acid and 10% v/v ACN. The detection wavelength was 282 nm. The calibration curve for 8OHdG (measured in spiked urine) was linear in the range 10–1000 ng/mL; R2 = 0.9993. The LOD was 3 ng/mL (11 nmol/L) of 8OHdG. Determination of the 8OHdG urinary levels was possible even in healthy individuals.
- 1 May 2014
- Published by Wiley in Electrophoresis
- Vol. 35 (17) , 2546-2549
Assay of urinary 8‐hydroxy‐2′‐deoxyguanosine by capillary electrophoresis with spectrophotometric detection using a high‐sensitivity detection cell and solid‐phase extraction
A sensitive capillary electrophoretic method featuring spectrophotometric detection using a commercial Z‐cell was devised for the assay of 8‐hydroxy‐2′‐deoxyguanosine (8OHdG) in human urine. Solid‐phase extraction (SPE) based on hydrophilic‐lipophilic‐balanced RP sorbent was utilized for urine sample pretreatment and analyte preconcentration. The separation was carried out in conventional fused‐silica capillaries employing a Z‐cell with hydrodynamic sample injection (at 50 mbar for 12 s). The BGE (pH* 9.2, adjusted with 1 M NaOH) contained 0.15 M boric acid and 10% v/v ACN. The detection wavelength was 282 nm. The calibration curve for 8OHdG (measured in spiked urine) was linear in the range 10–1000 ng/mL; R2 = 0.9993. The LOD was 3 ng/mL (11 nmol/L) of 8OHdG. Determination of the 8OHdG urinary levels was possible even in healthy individuals.
- 1 February 2013
- Published by Springer Nature in Food Analytical Methods
- Vol. 6 (6) , 1561-1567
Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis
- 1 February 2013
- Published by Springer Nature in Food Analytical Methods
- Vol. 6 (6) , 1561-1567
Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis
- 9 March 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 379 (5-6) , 754-758
Rapid automated assay of anti-oxidation/radical-scavenging activity of natural substances by sequential injection technique (SIA) using spectrophotometric detection
A PC-controlled sequential injection analysis (SIA) system equipped with a spectrophotometric diode-array detector is used for rapid monitoring and evaluation of antioxidation/radical scavenging activity of biological samples. The automated method is based on the known reaction of stable 2,2′-diphenyl-1-picrylhydrazyl radical (DPPH) with antioxidants in organic or aqueous-organic media resulting in bleaching of DPPH due to its “quenching” by the interaction with the analytes. The decrease of the absorbance of DPPH (compared to blank experiment carried out with water–ethanol 1:1 instead of the test solution) measured at 525 nm is related to concentration of an antioxidant in the test solution. With the optimised SIA procedure it is possible to detect down to micromolar concentrations of model antioxidants such as ascorbic acid, caffeic acid, (+)-catechin, (−)-epicatechin and rutin and to evaluate the concentration of these antioxidants in the micromolar to millimolar range. The sample throughput is 45 h−1. Thanks to its rapidity and sensitivity, the proposed SIA method is suitable for performing routine screening tests for the presence of various antioxidants in large series of lyophilised herbal or mushroom extracts (the amount of sample needed for the analysis is several milligrams).
- 9 March 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 379 (5-6) , 754-758
Rapid automated assay of anti-oxidation/radical-scavenging activity of natural substances by sequential injection technique (SIA) using spectrophotometric detection
A PC-controlled sequential injection analysis (SIA) system equipped with a spectrophotometric diode-array detector is used for rapid monitoring and evaluation of antioxidation/radical scavenging activity of biological samples. The automated method is based on the known reaction of stable 2,2′-diphenyl-1-picrylhydrazyl radical (DPPH) with antioxidants in organic or aqueous-organic media resulting in bleaching of DPPH due to its “quenching” by the interaction with the analytes. The decrease of the absorbance of DPPH (compared to blank experiment carried out with water–ethanol 1:1 instead of the test solution) measured at 525 nm is related to concentration of an antioxidant in the test solution. With the optimised SIA procedure it is possible to detect down to micromolar concentrations of model antioxidants such as ascorbic acid, caffeic acid, (+)-catechin, (−)-epicatechin and rutin and to evaluate the concentration of these antioxidants in the micromolar to millimolar range. The sample throughput is 45 h−1. Thanks to its rapidity and sensitivity, the proposed SIA method is suitable for performing routine screening tests for the presence of various antioxidants in large series of lyophilised herbal or mushroom extracts (the amount of sample needed for the analysis is several milligrams).
- 3 November 2002
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 30 (1) , 13-20
SIMPLE LABORATORY-MADE AUTOMATED SEQUENTIAL INJECTION ANALYSIS (SIA) DEVICE. I. DESIGN AND TESTING OF THE HARDWARE COMPONENT
- 3 November 2002
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 30 (1) , 13-20
SIMPLE LABORATORY-MADE AUTOMATED SEQUENTIAL INJECTION ANALYSIS (SIA) DEVICE. I. DESIGN AND TESTING OF THE HARDWARE COMPONENT
- 1 August 2000
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 23 (1) , 135-142
Capillary isotachophoretic determination of flufenamic, mefenamic, niflumic and tolfenamic acid in pharmaceuticals
- 1 August 2000
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 23 (1) , 135-142
Capillary isotachophoretic determination of flufenamic, mefenamic, niflumic and tolfenamic acid in pharmaceuticals