Hongen Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hongen Liao has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Etsuko Kobayashi
The University of Tokyo
4 shared publications - Ichiro Sakuma
The University of Tokyo
4 shared publications - Takeyoshi Dohi
The University of Tokyo
4 shared publications Ken Masamune
The University of Tokyo
3 shared publications- Hiromasa Yamashita
Department of Mechanoinformatics Graduate School of Information Science and Technology, The University of Tokyo, Tokyo, Japan
2 shared publications - Kiyoshi Matsumiya
Graduate School of Information Science and Technology, The University. of Tokyoy, Japan
2 shared publications
Latest Publications
- 30 June 2013
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 22 (6) , 372-380
Direct minimally invasive intraoperative electrophysiological mapping of the heart
Introduction: Cardiac electrophysiology aims to describe and treat the electrical activity of the heart. Although an epicardial approach is valuable in many surgical treatments such as coronary artery bypass grafting, maze ablation, and cell transplantation, very few techniques suited for minimally invasive surgery are available for measurement of epicardial electrophysiology. Material and methods: We developed a novel endoscopically-deployable expanding electrode array that can be applied for minimally invasive surgery. Our device consists of a flexible electrode array attached to arms which open and close the electrode sheet. Furthermore, we also developed a computer program to overlay an epicardial electrophysiological map on an endoscopic image. We performed both laboratory and in vivo experiments to examine the feasibility in clinical situations. Results: Evaluation experiments demonstrated that our novel mapping process that assumes spherical deformation of the electrode array enables us to overlay each electrode position with an accuracy of < 1 mm. Results of animal experiments using large animals (one dog and two pigs) demonstrated that our system enables construction of epicardial electrophysiological maps. Conclusion: A novel endoscopically deployable expanding electrode array was developed. Evaluation experiments demonstrated that our device can be manipulated in simulated minimally invasive surgery, and enables construction of epicardial electrophysiological maps.
- 30 June 2013
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 22 (6) , 372-380
Direct minimally invasive intraoperative electrophysiological mapping of the heart
Introduction: Cardiac electrophysiology aims to describe and treat the electrical activity of the heart. Although an epicardial approach is valuable in many surgical treatments such as coronary artery bypass grafting, maze ablation, and cell transplantation, very few techniques suited for minimally invasive surgery are available for measurement of epicardial electrophysiology. Material and methods: We developed a novel endoscopically-deployable expanding electrode array that can be applied for minimally invasive surgery. Our device consists of a flexible electrode array attached to arms which open and close the electrode sheet. Furthermore, we also developed a computer program to overlay an epicardial electrophysiological map on an endoscopic image. We performed both laboratory and in vivo experiments to examine the feasibility in clinical situations. Results: Evaluation experiments demonstrated that our novel mapping process that assumes spherical deformation of the electrode array enables us to overlay each electrode position with an accuracy of < 1 mm. Results of animal experiments using large animals (one dog and two pigs) demonstrated that our system enables construction of epicardial electrophysiological maps. Conclusion: A novel endoscopically deployable expanding electrode array was developed. Evaluation experiments demonstrated that our device can be manipulated in simulated minimally invasive surgery, and enables construction of epicardial electrophysiological maps.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 8 (1) , 17-26
A Miniaturized Shock-Wave Device for Mounting on Forceps
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 8 (1) , 17-26
A Miniaturized Shock-Wave Device for Mounting on Forceps
- 1 January 2009
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2009.7, 259-260
J1102-1-6 Evaluation of influence on MRI scans to electromagnetic waves for Open type MRI
MRI is now utilized not only for diagnosis but also for intraoperative surgical treatment. Many MR Compatible robotic and mechatronics systems were developed by in order to treat within MRI. However, there is a problem that the leak electromagnetic waves from the developed instrument affect on MR images. Therefore, we evaluated the influence on MRI scans to electromagnetic waves for Open type MRI. As the result, in a resonant frequency band, electromagnetic waves will not affect MRI scans by less than -71.85 dBμA/m around the MR coil. We think that this evaluation result is effective for developing novel MR Compatible robotic and mechatronic systems for acquiring MR images.
- 1 January 2009
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2009.7, 259-260
J1102-1-6 Evaluation of influence on MRI scans to electromagnetic waves for Open type MRI
MRI is now utilized not only for diagnosis but also for intraoperative surgical treatment. Many MR Compatible robotic and mechatronics systems were developed by in order to treat within MRI. However, there is a problem that the leak electromagnetic waves from the developed instrument affect on MR images. Therefore, we evaluated the influence on MRI scans to electromagnetic waves for Open type MRI. As the result, in a resonant frequency band, electromagnetic waves will not affect MRI scans by less than -71.85 dBμA/m around the MR coil. We think that this evaluation result is effective for developing novel MR Compatible robotic and mechatronic systems for acquiring MR images.
- Open Access
- 1 January 2007
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 9 (2) , 91-101
Development of a Miniature 2-DOFs Bending Manipulator with Bipolar Coagulator
We developed a miniature 2-DOFs bending manipulator of 5-mm diameter for laparoscopic surgery. Bending directions of the mechanism are perpendicular and the mechanisms are controllable respectively. A new wire-connected linkage-driven bending mechanism is built in the manipulator to drive rotate joints for 2-DOFs motion. This manipulator has a central channel of 1.3-mm diameter to drive a pair of blades with electrodes as the tip-side bipolar-coagulator. Surgeons control the manipulator with a grip-type interface in one hand. In mechanical performance evaluations, bending angle was maximum 153.9degrees (from -71.6 to 82.3 degrees) with positioning reproducibility of maximum 0.7mm. About generated force, holding force of bending mechanism was more than 1.82N, and grasping force by a pair of blades as maximum 3.70N. In vivo experiment using a pig (38kg, male) with laparoscopy, we evaluated whether the manipulator performed as a suitable bipolar coagulator for practical clinical use. We were able to coagulate living tissues and occlude blood vessels on the mesenterium completely. In conclusion, our new bending mechanism is useful for miniaturization of the laparoscopic manipulator with the simple structure and high mechanical performance.
- 1 January 2007
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 9 (2) , 91-101
Open AccessDevelopment of a Miniature 2-DOFs Bending Manipulator with Bipolar Coagulator
We developed a miniature 2-DOFs bending manipulator of 5-mm diameter for laparoscopic surgery. Bending directions of the mechanism are perpendicular and the mechanisms are controllable respectively. A new wire-connected linkage-driven bending mechanism is built in the manipulator to drive rotate joints for 2-DOFs motion. This manipulator has a central channel of 1.3-mm diameter to drive a pair of blades with electrodes as the tip-side bipolar-coagulator. Surgeons control the manipulator with a grip-type interface in one hand. In mechanical performance evaluations, bending angle was maximum 153.9degrees (from -71.6 to 82.3 degrees) with positioning reproducibility of maximum 0.7mm. About generated force, holding force of bending mechanism was more than 1.82N, and grasping force by a pair of blades as maximum 3.70N. In vivo experiment using a pig (38kg, male) with laparoscopy, we evaluated whether the manipulator performed as a suitable bipolar coagulator for practical clinical use. We were able to coagulate living tissues and occlude blood vessels on the mesenterium completely. In conclusion, our new bending mechanism is useful for miniaturization of the laparoscopic manipulator with the simple structure and high mechanical performance.
- 1 January 2006
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 18 (Supplement) , 77
3-D Stereoscopic Visualization of Medical Image for MRI-guided Surgery
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2006
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 18 (Supplement) , 77
3-D Stereoscopic Visualization of Medical Image for MRI-guided Surgery
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2004
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 16 (Supplement) , 241-242
Image-guided Surgical Support System Using Integral Videography
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2004
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 16 (Supplement) , 241-242
Image-guided Surgical Support System Using Integral Videography
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies