Gerald R. Harris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gerald R. Harris has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Paul M. Gammell
Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, MD 20993, USA
4 shared publications - Bruce A. Herman
U.S. Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, MD 20993, USA
2 shared publications Matthew R. Myers
2 shared publications- Subha Maruvada
U.S. Food and Drug Administration, 10903 New Hampshire Ave., Bldg. WO 62-2222, Silver Spring, MD 20993
2 shared publications Bruce A. Herman
1 shared publicationDiane M. Nell
US Food and Drug Administration, Silver Spring, Maryland USA
1 shared publication
Latest Publications
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4152
Challenges in the characterization of high intensity therapeutic ultrasound devices and fields and regulatory guidance development
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4152
Challenges in the characterization of high intensity therapeutic ultrasound devices and fields and regulatory guidance development
- 1 November 2013
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 32 (11) , 1921-1932
Trends in Diagnostic Ultrasound Acoustic Output From Data Reported to the US Food and Drug Administration for Device Indications That Include Fetal Applications
Objectives: A survey was conducted of acoustic output data received by the US Food and Drug Administration for diagnostic ultrasound devices whose indications for use include fetal applications to assess trends in maximum available acoustic output over time.Methods: Data were collected from 124 regulatory submissions received between 1984 and 2010. Data collection excluded transducers not indicated for diagnostic fetal imaging. The output parameters of ultrasonic power, mean center frequency, and bone thermal index (TIB) were extracted or computed from the submissions for 3 periods: 1984–1989, 1992–1997, and 2005–2010. The data were stratified according to the following imaging modes: M‐mode, B/M‐mode, pulsed wave Doppler, color flow Doppler, and continuous wave Doppler.Results: Ultrasonic power and maximum TIB values have increased roughly an order of magnitude from pre‐1991 to post‐1991 periods; the center frequency has decreased somewhat (4.2 to 3.4 MHz). The percentage of Doppler‐mode transducers has increased substantially over time, with the majority of the diagnostic fetal imaging transducers currently designed to operate in Doppler modes; this increase is particularly important, since Doppler modes generate much higher TIB levels than B/M‐modes. Color flow Doppler ultrasound currently operates at the highest mean ultrasonic power level (with a 14‐fold increase over time).Conclusions: The observed trends in increased acoustic output for both Doppler and non‐Doppler modes underscore the widely recognized importance of adherence to the ALARA (as low as reasonably achievable) principle and prudent use in fetal ultrasound imaging.
- 1 November 2013
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 32 (11) , 1921-1932
Trends in Diagnostic Ultrasound Acoustic Output From Data Reported to the US Food and Drug Administration for Device Indications That Include Fetal Applications
Objectives: A survey was conducted of acoustic output data received by the US Food and Drug Administration for diagnostic ultrasound devices whose indications for use include fetal applications to assess trends in maximum available acoustic output over time.Methods: Data were collected from 124 regulatory submissions received between 1984 and 2010. Data collection excluded transducers not indicated for diagnostic fetal imaging. The output parameters of ultrasonic power, mean center frequency, and bone thermal index (TIB) were extracted or computed from the submissions for 3 periods: 1984–1989, 1992–1997, and 2005–2010. The data were stratified according to the following imaging modes: M‐mode, B/M‐mode, pulsed wave Doppler, color flow Doppler, and continuous wave Doppler.Results: Ultrasonic power and maximum TIB values have increased roughly an order of magnitude from pre‐1991 to post‐1991 periods; the center frequency has decreased somewhat (4.2 to 3.4 MHz). The percentage of Doppler‐mode transducers has increased substantially over time, with the majority of the diagnostic fetal imaging transducers currently designed to operate in Doppler modes; this increase is particularly important, since Doppler modes generate much higher TIB levels than B/M‐modes. Color flow Doppler ultrasound currently operates at the highest mean ultrasonic power level (with a 14‐fold increase over time).Conclusions: The observed trends in increased acoustic output for both Doppler and non‐Doppler modes underscore the widely recognized importance of adherence to the ALARA (as low as reasonably achievable) principle and prudent use in fetal ultrasound imaging.
- 1 April 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (4) , 580-586
A Comparison of the Thermal-Dose Equation and the Intensity-Time Product, Itm, for Predicting Tissue Damage Thresholds
- 1 April 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (4) , 580-586
A Comparison of the Thermal-Dose Equation and the Intensity-Time Product, Itm, for Predicting Tissue Damage Thresholds
- Open Access
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 145-148
FDA regulation of clinical high intensity focused ultrasound (HIFU) devices
In the U. S., medical devices are regulated under the authority of the 1976 Medical Device Amendments to the Food, Drug, and Cosmetic Act, with the Food and Drug Administration's Center for Devices and Radiological Health having primary responsibility. The Act defines several regulatory paths to market depending on the complexity of the device and indications for use. For most high intensity focused ultrasound (HIFU) devices the premarket submissions include both pre-clinical and clinical data. Pre-clinical testing generally comprises ultrasound power measurements and field characterization, in vitro and in vivo temperature measurements, thermal computational modeling, and demonstrating the accuracy for targeting the region of interest and monitoring treatment progress. Protocols for clinical trials are developed by the device sponsor in conjunction with FDA medical and scientific staff. Currently there are no recognized guidance or standards documents for HIFU testing that could be used in the regulatory review process, but such work is underway within the International Electrotechnical Commission.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 145-148
Open AccessFDA regulation of clinical high intensity focused ultrasound (HIFU) devices
In the U. S., medical devices are regulated under the authority of the 1976 Medical Device Amendments to the Food, Drug, and Cosmetic Act, with the Food and Drug Administration's Center for Devices and Radiological Health having primary responsibility. The Act defines several regulatory paths to market depending on the complexity of the device and indications for use. For most high intensity focused ultrasound (HIFU) devices the premarket submissions include both pre-clinical and clinical data. Pre-clinical testing generally comprises ultrasound power measurements and field characterization, in vitro and in vivo temperature measurements, thermal computational modeling, and demonstrating the accuracy for targeting the region of interest and monitoring treatment progress. Protocols for clinical trials are developed by the device sponsor in conjunction with FDA medical and scientific staff. Currently there are no recognized guidance or standards documents for HIFU testing that could be used in the regulatory review process, but such work is underway within the International Electrotechnical Commission.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 2995
Temperature measurements and determination of cavitation thresholds during High Intensity Focused Ultrasound (HIFU) Exposures in ex-vivo porcine muscle
Cavitation in HIFU procedures can yield unpredictable results, particularly when the same location is targeted for more than several seconds. To study this effect,temperature rise was measured in fresh ex‐vivo porcine tissue during HIFU exposures. Immediately following euthanasia, a section of back muscle (latissimus dorsi) was resected and a 50 μm diameter fine bare wire thermocouple was placed via needle through the tissue. 825 kHz HIFU was then applied to the tissue focused at the thermocouple junction. Thirty second HIFU exposures of increasing pressure from 1‐7.5 MPa were applied and the temperature rise and decay during and after sonication were recorded. B‐mode imaging was used to monitor any cavitation activity during sonication. If cavitation was noted during the sonication, the sonication was repeated at the same pressure level two more times at 20 minute intervals in order to characterize the repeatability given that cavitation has occurred. The cavitation threshold of porcine muscle was determined to be between 4 and 7 MPa. Temperature traces obtained at various pressure levels demonstrated a wide range of heating profiles in fresh ex‐vivo tissue due to both the occurrence of cavitation and viscous heating artifacts. (This research was supported by DARPA IAG # 224‐05‐6016).
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 2995
Temperature measurements and determination of cavitation thresholds during High Intensity Focused Ultrasound (HIFU) Exposures in ex-vivo porcine muscle
Cavitation in HIFU procedures can yield unpredictable results, particularly when the same location is targeted for more than several seconds. To study this effect,temperature rise was measured in fresh ex‐vivo porcine tissue during HIFU exposures. Immediately following euthanasia, a section of back muscle (latissimus dorsi) was resected and a 50 μm diameter fine bare wire thermocouple was placed via needle through the tissue. 825 kHz HIFU was then applied to the tissue focused at the thermocouple junction. Thirty second HIFU exposures of increasing pressure from 1‐7.5 MPa were applied and the temperature rise and decay during and after sonication were recorded. B‐mode imaging was used to monitor any cavitation activity during sonication. If cavitation was noted during the sonication, the sonication was repeated at the same pressure level two more times at 20 minute intervals in order to characterize the repeatability given that cavitation has occurred. The cavitation threshold of porcine muscle was determined to be between 4 and 7 MPa. Temperature traces obtained at various pressure levels demonstrated a wide range of heating profiles in fresh ex‐vivo tissue due to both the occurrence of cavitation and viscous heating artifacts. (This research was supported by DARPA IAG # 224‐05‐6016).
- 1 June 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (6) , 2914-2918
1-3 piezoelectric composite transducers for swept-frequency calibration of hydrophones from 100 kHz to 2 MHz
Rapid calibration of hydrophones used in biomedical ultrasound is possible with swept frequency techniques such as time delay spectrometry. However, calibrations below 2 MHz largely have been neglected because of insufficient transmitting transducer bandwidth, even though important medical applications operate in this range. To address this deficiency, several transmitting transducer designs were developed and tested, and two 1-3 piezoelectric composite designs were found to have the requisite bandwidth and uniformity of response. In one the element has a plane front face and spherically concave back face (plano-concave), and in the second both faces are concave, but with different radii of curvature (biconcave). The nonuniform thickness disperses the thickness resonance, and the composite structure suppresses radial-mode resonances. Also, the composite’s lower acoustic impedance provides a more efficient match to water. The piezoelectric composite transducers were found to have transmitting pressure sensitivities superior to ceramic single-element and segmented designs having similar dimensions, and their responses were significantly more uniform variation from 0.1–2 MHz, with fine structure variation), likely due to decreased contributions from radial modes.- 1 June 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (6) , 2914-2918
1-3 piezoelectric composite transducers for swept-frequency calibration of hydrophones from 100 kHz to 2 MHz
Rapid calibration of hydrophones used in biomedical ultrasound is possible with swept frequency techniques such as time delay spectrometry. However, calibrations below 2 MHz largely have been neglected because of insufficient transmitting transducer bandwidth, even though important medical applications operate in this range. To address this deficiency, several transmitting transducer designs were developed and tested, and two 1-3 piezoelectric composite designs were found to have the requisite bandwidth and uniformity of response. In one the element has a plane front face and spherically concave back face (plano-concave), and in the second both faces are concave, but with different radii of curvature (biconcave). The nonuniform thickness disperses the thickness resonance, and the composite structure suppresses radial-mode resonances. Also, the composite’s lower acoustic impedance provides a more efficient match to water. The piezoelectric composite transducers were found to have transmitting pressure sensitivities superior to ceramic single-element and segmented designs having similar dimensions, and their responses were significantly more uniform variation from 0.1–2 MHz, with fine structure variation), likely due to decreased contributions from radial modes.- 1 April 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 113 (4_Suppleme) , 2324
A voltage-doubling (2-kV) pulser for biomedical ultrasound measurements
- 1 April 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 113 (4_Suppleme) , 2324
A voltage-doubling (2-kV) pulser for biomedical ultrasound measurements
- 25 October 2002
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 112 (5_Suppleme) , 2404
Temperature rise and safety considerations for radiation force ultrasound imaging
- 25 October 2002
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 112 (5_Suppleme) , 2404
Temperature rise and safety considerations for radiation force ultrasound imaging
- 1 February 1999
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 105 (2) , 725-731
Sensitivity measurements of piezoelectric polymer hydrophones from 0.2–2 MHz using a broadband-pulse technique
- 1 February 1999
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 105 (2) , 725-731
Sensitivity measurements of piezoelectric polymer hydrophones from 0.2–2 MHz using a broadband-pulse technique
- 1 May 1998
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 103 (5_Suppleme) , 3016
Effects of diffraction on the sensitivity of needle-type ultrasonic receivers
- 1 May 1998
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 103 (5_Suppleme) , 3016
Effects of diffraction on the sensitivity of needle-type ultrasonic receivers