Paul M. Gammell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Paul M. Gammell has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Gerald R. Harris
U.S. Food and Drug Administration, 10903 New Hampshire Ave., Bldg. WO 62-2222, Silver Spring, MD 20993
4 shared publications G.R. Harris
1 shared publicationGerald R. Harris
1 shared publicationJeffrey M. Porter
FDA/CDRH, 9200 Corporate Blvd., HFZ-132, Rockville, MD 20850
1 shared publicationMatthew R. Myers
Food and Drug Administration, Center for Devices and Radiological Health, Rockville, Maryland 20852
1 shared publicationSubha Maruvada
1 shared publication
Latest Publications
- 11 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 54 (5) , 1036-1044
An ultrasonic time-delay spectrometry system employing digital processing
Time-delay spectrometry (TDS) is a swept-frequency technique that has proven useful in several ultrasonic applications. Commercial TDS systems are available, but only in the audio frequency range. Several ultrasonic research TDS systems have been constructed, and they have been used effectively for substitution calibration of hydrophones and for measurement of attenuation and sound velocity in materials. Unfortunately these systems depend on features of commercial equipment no longer manufactured, so a new system has been designed using modern equipment and straightforward signal processing. This system requires a frequency source with a reasonably linear sweep of frequency versus time, audio frequency filters, a standard double-balanced mixer, a power splitter, a waveform digitizer capable of handling audio frequency signals, and a personal computer. An optional implementation that shifts the signal to a lower frequency for more convenient digitization and easier velocity measurements additionally requires an audio frequency oscillator and an audio-range analog multiplier. The processing steps are performed with standard signal processing software. To demonstrate the operation of the system, substitution calibration measurements of hydrophones as well as attenuation measurements on a tissue mimicking material were obtained and compared to a custom TDS system previously described by the authors. The data from these two TDS systems agree to within plusmn0.5 dB in the 1-10 MHz frequency range used. Higher frequency source transducers could be used to extend this range
- 11 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 54 (5) , 1036-1044
An ultrasonic time-delay spectrometry system employing digital processing
Time-delay spectrometry (TDS) is a swept-frequency technique that has proven useful in several ultrasonic applications. Commercial TDS systems are available, but only in the audio frequency range. Several ultrasonic research TDS systems have been constructed, and they have been used effectively for substitution calibration of hydrophones and for measurement of attenuation and sound velocity in materials. Unfortunately these systems depend on features of commercial equipment no longer manufactured, so a new system has been designed using modern equipment and straightforward signal processing. This system requires a frequency source with a reasonably linear sweep of frequency versus time, audio frequency filters, a standard double-balanced mixer, a power splitter, a waveform digitizer capable of handling audio frequency signals, and a personal computer. An optional implementation that shifts the signal to a lower frequency for more convenient digitization and easier velocity measurements additionally requires an audio frequency oscillator and an audio-range analog multiplier. The processing steps are performed with standard signal processing software. To demonstrate the operation of the system, substitution calibration measurements of hydrophones as well as attenuation measurements on a tissue mimicking material were obtained and compared to a custom TDS system previously described by the authors. The data from these two TDS systems agree to within plusmn0.5 dB in the 1-10 MHz frequency range used. Higher frequency source transducers could be used to extend this range
- 1 December 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (12) , 1722-1728
IGBT-based kilovoltage pulsers for ultrasound measurement applications
Two high-voltage pulser designs are presented that offer advantages in some ultrasound measurement applications, such as driving thick ultrasonic source transducers used for broadband measurements of attenuation or hydrophone frequency response and directivity. The pulsers use integrated gate bipolar transistors (IGBTs) as the switching devices, and in one design an output voltage pulse is produced that has a peak amplitude nearly twice that of the supply voltage. The pulsers are inexpensive and relatively easy to construct. The power supply need only provide the average current to charge the capacitors, as opposed to the much higher peak pulse current. With a 1200 V supply and a pulse repetition frequency of 200 Hz, the nondoubling and doubling pulsers provided peak voltages of greater than 1100 V and 2200 V, respectively, into loads ranging from 50 /spl Omega/ to 500 /spl Omega/. For a 50 /spl Omega/ load, slewing rates of 38 V/ns and 23 V/ns were measured for the nondoubling and doubling pulsers, respectively. For a 500 /spl Omega/ load these values were 56 V/ns and 36 V/ns.
- 1 December 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (12) , 1722-1728
IGBT-based kilovoltage pulsers for ultrasound measurement applications
Two high-voltage pulser designs are presented that offer advantages in some ultrasound measurement applications, such as driving thick ultrasonic source transducers used for broadband measurements of attenuation or hydrophone frequency response and directivity. The pulsers use integrated gate bipolar transistors (IGBTs) as the switching devices, and in one design an output voltage pulse is produced that has a peak amplitude nearly twice that of the supply voltage. The pulsers are inexpensive and relatively easy to construct. The power supply need only provide the average current to charge the capacitors, as opposed to the much higher peak pulse current. With a 1200 V supply and a pulse repetition frequency of 200 Hz, the nondoubling and doubling pulsers provided peak voltages of greater than 1100 V and 2200 V, respectively, into loads ranging from 50 /spl Omega/ to 500 /spl Omega/. For a 50 /spl Omega/ load, slewing rates of 38 V/ns and 23 V/ns were measured for the nondoubling and doubling pulsers, respectively. For a 500 /spl Omega/ load these values were 56 V/ns and 36 V/ns.
- 1 April 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 113 (4_Suppleme) , 2324
A voltage-doubling (2-kV) pulser for biomedical ultrasound measurements
- 1 April 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 113 (4_Suppleme) , 2324
A voltage-doubling (2-kV) pulser for biomedical ultrasound measurements
- 1 February 1999
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 105 (2) , 725-731
Sensitivity measurements of piezoelectric polymer hydrophones from 0.2–2 MHz using a broadband-pulse technique
- 1 February 1999
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 105 (2) , 725-731
Sensitivity measurements of piezoelectric polymer hydrophones from 0.2–2 MHz using a broadband-pulse technique
- 1 May 1998
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 103 (5_Suppleme) , 3016
Effects of diffraction on the sensitivity of needle-type ultrasonic receivers
- 1 May 1998
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 103 (5_Suppleme) , 3016
Effects of diffraction on the sensitivity of needle-type ultrasonic receivers
- 1 November 1996
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 100 (5) , 3115-3120
The response of transiently excited thick transducers at low frequencies
- 1 November 1996
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 100 (5) , 3115-3120
The response of transiently excited thick transducers at low frequencies