Gerald D. Dodd
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gerald D. Dodd has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Anthony C. Lanctot
From the Department of Radiology, School of Medicine, University of Colorado, Mail Stop L954, 12401 E 17th Ave, PO Box 6510, Aurora, CO 80045
3 shared publications- David M. Naeger
Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA
2 shared publications Michael D. Orsi
South Texas Radiology Group, San Antonio, Texas
2 shared publicationsRex A. Cardan
Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama
2 shared publicationsStephanie K. Burns
Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
2 shared publicationsTyler J. Green
Department of Radiology, University of Colorado School of Medicine, Denver, Colorado
2 shared publications
Latest Publications
- 1 May 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 283 (2) , 399-407
Effect of Change in Portal Vein Flow Rates on Hepatic Ablations Created with a Bipolar Radiofrequency Ablation Device
Our study shows that the size and shape of coagulation necrosis created by the bipolar radiofrequency ablation device tested in this study is not affected significantly by changes in portal vein blood flow rates. PurposeTo investigate the effect of change in portal vein flow rates on the size and shape of ablations created by a bipolar radiofrequency (RF) ablation device.Materials and MethodsThis study was exempt from institutional animal care and use committee review. An in vitro bovine liver model perfused with autologous blood via the portal vein at three flow rates (60, 80, 100 mL/min per 100 g of liver) was used. Four ablations, two bipolar and two monopolar (control probe), were made in each of five livers perfused at each flow rate. Short- and long-axis diameters were measured from gross specimens, and volume and sphericity index were calculated for each ablation. A general linear mixed model accounting for correlation within the liver was used to evaluate the effects of flow on ablations. Analyses were performed by using software.ResultsThere was no significant difference in the size or shape of ablations created by the bipolar device at the different flow rates (P > .05 for all outcomes). The monopolar de...
- 1 May 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 283 (2) , 399-407
Effect of Change in Portal Vein Flow Rates on Hepatic Ablations Created with a Bipolar Radiofrequency Ablation Device
Our study shows that the size and shape of coagulation necrosis created by the bipolar radiofrequency ablation device tested in this study is not affected significantly by changes in portal vein blood flow rates. PurposeTo investigate the effect of change in portal vein flow rates on the size and shape of ablations created by a bipolar radiofrequency (RF) ablation device.Materials and MethodsThis study was exempt from institutional animal care and use committee review. An in vitro bovine liver model perfused with autologous blood via the portal vein at three flow rates (60, 80, 100 mL/min per 100 g of liver) was used. Four ablations, two bipolar and two monopolar (control probe), were made in each of five livers perfused at each flow rate. Short- and long-axis diameters were measured from gross specimens, and volume and sphericity index were calculated for each ablation. A general linear mixed model accounting for correlation within the liver was used to evaluate the effects of flow on ablations. Analyses were performed by using software.ResultsThere was no significant difference in the size or shape of ablations created by the bipolar device at the different flow rates (P > .05 for all outcomes). The monopolar de...
- 6 January 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1070) , 20160661
The prediction of radiofrequency ablation zone volume using vascular indices of 3-dimensional volumetric colour Doppler ultrasound in an in vitro blood-perfused bovine liver model
Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (R β 2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use.
- 6 January 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1070) , 20160661
The prediction of radiofrequency ablation zone volume using vascular indices of 3-dimensional volumetric colour Doppler ultrasound in an in vitro blood-perfused bovine liver model
Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (R β 2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use.
- 1 December 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 13 (12) , 1477-1482
Driving Innovation in Radiology: A Summary of the 2015 Intersociety Committee Summer Conference
- 1 December 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 13 (12) , 1477-1482
Driving Innovation in Radiology: A Summary of the 2015 Intersociety Committee Summer Conference
- 1 March 2015
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 12 (3) , 228-234
Reengineering the Radiology Enterprise: A Summary of the 2014 Intersociety Committee Summer Conference
- 1 March 2015
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 12 (3) , 228-234
Reengineering the Radiology Enterprise: A Summary of the 2014 Intersociety Committee Summer Conference
- 1 January 2015
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 12 (1) , 34-37
Radiology Journals in Transition: A Summary of the 2013 Intersociety Committee Summer Conference
- 1 January 2015
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 12 (1) , 34-37
Radiology Journals in Transition: A Summary of the 2013 Intersociety Committee Summer Conference
- 16 January 2014
- Published by Wiley in Medical Physics
- Vol. 41 (2) , 023701
The design and fabrication of two portal vein flow phantoms by different methods
Purpose:: This study outlines the design and fabrication techniques for two portal vein flow phantoms.Methods:: A materials study was performed as a precursor to this phantom fabrication effort and the desired material properties are restated for continuity. A three‐dimensional portal vein pattern was created from the Visual Human database. The portal vein pattern was used to fabricate two flow phantoms by different methods with identical interior surface geometry using computer aided design software tools and rapid prototyping techniques. One portal flow phantom was fabricated within a solid block of clear silicone for use on a table with Ultrasound or within medical imaging systems such as MRI, CT, PET, or SPECT. The other portal flow phantom was fabricated as a thin walled tubular latex structure for use in water tanks with Ultrasound imaging. Both phantoms were evaluated for usability and durability.Results:: Both phantoms were fabricated successfully and passed durability criteria for flow testing in the next project phase.Conclusions:: The fabrication methods and materials employed for the study yielded durable portal vein phantoms.
- 16 January 2014
- Published by Wiley in Medical Physics
- Vol. 41 (2) , 023701
The design and fabrication of two portal vein flow phantoms by different methods
Purpose:: This study outlines the design and fabrication techniques for two portal vein flow phantoms.Methods:: A materials study was performed as a precursor to this phantom fabrication effort and the desired material properties are restated for continuity. A three‐dimensional portal vein pattern was created from the Visual Human database. The portal vein pattern was used to fabricate two flow phantoms by different methods with identical interior surface geometry using computer aided design software tools and rapid prototyping techniques. One portal flow phantom was fabricated within a solid block of clear silicone for use on a table with Ultrasound or within medical imaging systems such as MRI, CT, PET, or SPECT. The other portal flow phantom was fabricated as a thin walled tubular latex structure for use in water tanks with Ultrasound imaging. Both phantoms were evaluated for usability and durability.Results:: Both phantoms were fabricated successfully and passed durability criteria for flow testing in the next project phase.Conclusions:: The fabrication methods and materials employed for the study yielded durable portal vein phantoms.
- 31 May 2013
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 10 (5) , 341-344
The ACR Intersociety Committee: History, Activities, and Membership
- 31 May 2013
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 10 (5) , 341-344
The ACR Intersociety Committee: History, Activities, and Membership
- 1 April 2013
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 267 (1) , 129-136
Effect of Variation of Portal Venous Blood Flow on Radiofrequency and Microwave Ablations in a Blood-perfused Bovine Liver Model
To assess whether there is a significant difference in the effect of incremental changes of portal venous blood flow rates on the size of radiofrequency (RF) versus microwave (MW) ablation lesions in an ex vivo blood-perfused bovine liver model. This study was exempt from approval by the Institutional Animal Care and Use Committee. Sixty ablations (30 MW and 30 RF ablations) were performed ex vivo in 15 bovine livers perfused with autologous blood via the portal vein at 60, 70, 80, 90, and 100 mL/min per 100 g of liver tissue (three livers were used for each flow rate). Long-axis diameter (LAD), short-axis diameter (SAD), and volume were measured for each ablation lesion. A general linear mixed model was used to examine the effect of location, ablation device, and flow rate on LAD, SAD, and volume. Results were considered to indicate a significant difference at P less than .05. Location was not a significant predictor of LAD, SAD, or volume (P ≥ .4). The slope of the relationship between flow rate and LAD, SAD, and volume was significantly different according to ablation device (P < .0001). For RF ablation lesions, the mean LAD, SAD, and volume demonstrated a significant inverse relationship with flow rate, while the measurements for MW ablation did not change with variation in flow rates. The size of RF ablation lesions is highly variable, with a significant inverse relationship to the rate of portal venous blood flow. Conversely, the size of MW ablation lesions is unaffected by changes in portal venous blood flow. The consistency of the size of MW ablation lesions could translate into a higher local tumor eradication rate than that reported with RF ablation.
- 1 April 2013
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 267 (1) , 129-136
Effect of Variation of Portal Venous Blood Flow on Radiofrequency and Microwave Ablations in a Blood-perfused Bovine Liver Model
To assess whether there is a significant difference in the effect of incremental changes of portal venous blood flow rates on the size of radiofrequency (RF) versus microwave (MW) ablation lesions in an ex vivo blood-perfused bovine liver model. This study was exempt from approval by the Institutional Animal Care and Use Committee. Sixty ablations (30 MW and 30 RF ablations) were performed ex vivo in 15 bovine livers perfused with autologous blood via the portal vein at 60, 70, 80, 90, and 100 mL/min per 100 g of liver tissue (three livers were used for each flow rate). Long-axis diameter (LAD), short-axis diameter (SAD), and volume were measured for each ablation lesion. A general linear mixed model was used to examine the effect of location, ablation device, and flow rate on LAD, SAD, and volume. Results were considered to indicate a significant difference at P less than .05. Location was not a significant predictor of LAD, SAD, or volume (P ≥ .4). The slope of the relationship between flow rate and LAD, SAD, and volume was significantly different according to ablation device (P < .0001). For RF ablation lesions, the mean LAD, SAD, and volume demonstrated a significant inverse relationship with flow rate, while the measurements for MW ablation did not change with variation in flow rates. The size of RF ablation lesions is highly variable, with a significant inverse relationship to the rate of portal venous blood flow. Conversely, the size of MW ablation lesions is unaffected by changes in portal venous blood flow. The consistency of the size of MW ablation lesions could translate into a higher local tumor eradication rate than that reported with RF ablation.
- 25 February 2013
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 10 (5) , 345-348
Radiology Online: Information, Education, and Networking—A Summary of the 2012 Intersociety Committee Summer Conference
- 25 February 2013
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 10 (5) , 345-348
Radiology Online: Information, Education, and Networking—A Summary of the 2012 Intersociety Committee Summer Conference
- 31 August 2012
- Published by Elsevier in Academic Radiology
- Vol. 19 (8) , 1018-1022
Radiofrequency Ablation of the Liver: Effect of Variation of Portal Venous Blood Flow on Lesion Size in an In-vitro Perfused Bovine Liver
- 31 August 2012
- Published by Elsevier in Academic Radiology
- Vol. 19 (8) , 1018-1022
Radiofrequency Ablation of the Liver: Effect of Variation of Portal Venous Blood Flow on Lesion Size in an In-vitro Perfused Bovine Liver