Latest Publications
- 3 April 2008
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 87B (1) , 77-82
Integrity of the stem‐cement interface in THA: Effects of stem surface finish and cement porosity
No consensus exists for the optimal surface finish on cemented total hip prosthesis stems. The purpose of this study was to determine the effects of stem finish and interfacial cement porosity on the integrity of the stem–cement interface. Simulated stems made of Co‐Cr, having polished or matte surfaces, at room temperature or heated to 37°C, were cemented into Sawbones simulated femurs. Push out testing of the stem–cement interface was performed immediately after cement polymerization and after two aging periods in 37°C saline or 37°C air, and the extent of interfacial porosity at the stem–cement interface was determined. Polished stems exhibited an average 60% greater interfacial strength than that of matte stems initially and up to 240% after aging treatments. Cement porosity at the stem–cement interface and incomplete cement interdigitation into surface asperities on matte stems likely allowed saline penetration into the stem–cement interface during wet aging, resulting in a rapid decrease of shear strength. Stem preheating to 37°C virtually eliminated interfacial pores and resulted in greater shear strengths regardless of surface finish. Polished stem surfaces with stem preheating provided the best interfacial shear strength and sealing ability against saline penetration into the stem–cement interface and could result in increased longevity of stem fixation. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008
- 3 April 2008
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 87B (1) , 77-82
Integrity of the stem‐cement interface in THA: Effects of stem surface finish and cement porosity
No consensus exists for the optimal surface finish on cemented total hip prosthesis stems. The purpose of this study was to determine the effects of stem finish and interfacial cement porosity on the integrity of the stem–cement interface. Simulated stems made of Co‐Cr, having polished or matte surfaces, at room temperature or heated to 37°C, were cemented into Sawbones simulated femurs. Push out testing of the stem–cement interface was performed immediately after cement polymerization and after two aging periods in 37°C saline or 37°C air, and the extent of interfacial porosity at the stem–cement interface was determined. Polished stems exhibited an average 60% greater interfacial strength than that of matte stems initially and up to 240% after aging treatments. Cement porosity at the stem–cement interface and incomplete cement interdigitation into surface asperities on matte stems likely allowed saline penetration into the stem–cement interface during wet aging, resulting in a rapid decrease of shear strength. Stem preheating to 37°C virtually eliminated interfacial pores and resulted in greater shear strengths regardless of surface finish. Polished stem surfaces with stem preheating provided the best interfacial shear strength and sealing ability against saline penetration into the stem–cement interface and could result in increased longevity of stem fixation. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008
- 1 January 2003
- Vol. 61, 118-22
Interobserver reliability and intraobserver reproducibility in suprascapular notch typing.
The size and shape of the suprascapular notch may be a factor in suprascapular nerve entrapment. The suprascapular notches of 623 scapulae were digitally photographed and used to determine notch type and area. Three researchers used to different classification systems for suprascapular notch typing. These systems were compared for interobserver reliability and intraobserver reproducibility using the kappa test. The mean kappa value for the classification used by Rengachary and colleagues was 0.468 and for the classification used by Ticker and associates was 0.531 for the inferior border of the notch and 0.736 for the superior border of the notch. The classification system used by Ticker and associates was more reliable and reproducible and produced both a superior and an inferior classification, making it possibly more clinically relevant than the classification system used by Rengachary and colleagues.
- 1 January 2003
- Vol. 61, 118-22
Interobserver reliability and intraobserver reproducibility in suprascapular notch typing.
The size and shape of the suprascapular notch may be a factor in suprascapular nerve entrapment. The suprascapular notches of 623 scapulae were digitally photographed and used to determine notch type and area. Three researchers used to different classification systems for suprascapular notch typing. These systems were compared for interobserver reliability and intraobserver reproducibility using the kappa test. The mean kappa value for the classification used by Rengachary and colleagues was 0.468 and for the classification used by Ticker and associates was 0.531 for the inferior border of the notch and 0.736 for the superior border of the notch. The classification system used by Ticker and associates was more reliable and reproducible and produced both a superior and an inferior classification, making it possibly more clinically relevant than the classification system used by Rengachary and colleagues.
- 1 January 2003
- Vol. 61, 132-4
Loading of the acetabulum by polyethylene and all-ceramic inserts in metal-backed acetabular cups.
Both static and dynamic loads were applied to metal-backed acetabular cups with ceramic or polyethylene inserts and the resulting load transmissions at a simulated bone interface were determined. Perfect fit and under-sized and over-sized cavities were prepared in simulated bone substrates, lined with Fuji pressure sensitive film, and acetabular cups inserted with physiological loads. The magnitude and location of contact forces between the cup and bone were measured. These cups were then subjected to a controlled impact load and the intensity and frequency of the loads transmitted to the substrate were determined. The results suggest that a polyethylene backing for ceramics is not necessary as there were no major differences in the static and dynamic stresses transmitted to the cup-bone interface with all polyethylene or ceramic inserts.
- 1 January 2003
- Vol. 61, 132-4
Loading of the acetabulum by polyethylene and all-ceramic inserts in metal-backed acetabular cups.
Both static and dynamic loads were applied to metal-backed acetabular cups with ceramic or polyethylene inserts and the resulting load transmissions at a simulated bone interface were determined. Perfect fit and under-sized and over-sized cavities were prepared in simulated bone substrates, lined with Fuji pressure sensitive film, and acetabular cups inserted with physiological loads. The magnitude and location of contact forces between the cup and bone were measured. These cups were then subjected to a controlled impact load and the intensity and frequency of the loads transmitted to the substrate were determined. The results suggest that a polyethylene backing for ceramics is not necessary as there were no major differences in the static and dynamic stresses transmitted to the cup-bone interface with all polyethylene or ceramic inserts.
- 1 January 2003
- Vol. 61, 135-6
A new test for bipolar prosthesis disassociation.
Because of several failures by dissociation of a redesigned bipolar prosthesis, a new, dynamic test was developed. This dynamic cam-out test represents a closer simulation of one possible clinical mechanism of bipolar disassociation. The results of dynamic testing are affected by the bipolar design, particularly the locking mechanism that was the problem with the redesigned prosthesis.
- 1 January 2003
- Vol. 61, 135-6
A new test for bipolar prosthesis disassociation.
Because of several failures by dissociation of a redesigned bipolar prosthesis, a new, dynamic test was developed. This dynamic cam-out test represents a closer simulation of one possible clinical mechanism of bipolar disassociation. The results of dynamic testing are affected by the bipolar design, particularly the locking mechanism that was the problem with the redesigned prosthesis.