Ashok Babu Puttranga Setty Talanki
Research Subjects
Research Interests
Ashok Babu Puttranga Setty Talanki has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Saboor Shaik
School of Mechanical Engineering, Vellore Institute of Technology, Vellore, India
2 shared publications - Sudesh Bekal
NMAM Institute of Technology , Nitte-574110 , Karnataka , India
2 shared publications - C. Ranganayakulu
Aeronautical Development Agency Vimanapura Post Bangalore-560 017
1 shared publication - Debasish Mahapatra
Department of Nephrology, Command Hospital Air Force, Bengaluru, Karnataka, India
1 shared publication - Kirankumar Gorantla
Mechanical Engineering Department, National Institute of Technology Karnataka, Surathkal, Mangalore-575025, Karnataka, India
1 shared publication - M. Amaranatha Raju
Aeronautical Development Agency Vimanapura Post Bangalore-560 017
1 shared publication
Latest Publications
- Open Access
- 2 August 2023
- Published by The Aeronautical Society of India in Journal of Aerospace Sciences and Technologies
- p. 488-499
All Electric Cooling System for Unmanned Aircrafts
This study brings out two All Electric Environmental Control System (AE-ECS) configurations for Unmanned Aircraft air-conditioning and performance evaluation of these two configurations interms of power consumption and fuel mass penalty. In conventional (or traditional) Bleed Air System, hot air is extracted from the engine compressor whereas in Bleed less Air Cycle system/Bleed less Vapour Cycle Systems (also called AE-ECS) bleed air extraction from engine is eliminated. Eliminating the extraction of bleed air from the engine in both the systems of Bleed less Air Cycle and Vapour Cycle System, saves the engine energy and thus increases the engine efficiency/thrust. In the present study performance of the Bleed less Air Cycle and Vapour Cycle systems are studied for typical flight envelop and heat loads of 5 kW. Bleed less Vapour Cycle System consumed less electric power compared to Bleed less Air Cycle System when compared for 5 kW cooling system requirements for an Unmanned Aircraft system. Fuel mass penalties are also calculated and compared for these two system configurations.
- 2 August 2023
- Published by The Aeronautical Society of India in Journal of Aerospace Sciences and Technologies
- p. 488-499
Open AccessAll Electric Cooling System for Unmanned Aircrafts
This study brings out two All Electric Environmental Control System (AE-ECS) configurations for Unmanned Aircraft air-conditioning and performance evaluation of these two configurations interms of power consumption and fuel mass penalty. In conventional (or traditional) Bleed Air System, hot air is extracted from the engine compressor whereas in Bleed less Air Cycle system/Bleed less Vapour Cycle Systems (also called AE-ECS) bleed air extraction from engine is eliminated. Eliminating the extraction of bleed air from the engine in both the systems of Bleed less Air Cycle and Vapour Cycle System, saves the engine energy and thus increases the engine efficiency/thrust. In the present study performance of the Bleed less Air Cycle and Vapour Cycle systems are studied for typical flight envelop and heat loads of 5 kW. Bleed less Vapour Cycle System consumed less electric power compared to Bleed less Air Cycle System when compared for 5 kW cooling system requirements for an Unmanned Aircraft system. Fuel mass penalties are also calculated and compared for these two system configurations.
- 18 July 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (33) , 41415-41436
Investigation on thermodynamic performance analysis and environmental effects of various new refrigerants used in air conditioners
The main aim of this present investigation is to evaluate performance and environmental impact analysis of various novel mixture refrigerants as R22 replacements theoretically. Refrigerants with lower global warming potential (GWP) can be adequate for bringing down emissions which are concerned for air conditioners. In this investigation, twenty-seven refrigerants were developed at several compositions. Important studies such as computation of CO2 emissions using total equivalent warming impact (TEWI), toxicity and flammability analysis of various considered refrigerants were also carried out in this investigation. Performance analysis of refrigerants was conducted under different operating conditions. Results showed that the energy efficiency ratios (EERs) of refrigerants such as R1270, RM30 (R152a/R1270/RE170 of 25/71/4 by mass percentage) and RM50 (R152a/R1270/RE170 of 10/85/5 by mass percentage) were closer to that of R22 and they are relatively lower than R22 by 0.95%, 1.34% and 1.80%, respectively. Toxicity investigation exhibited that all the refrigerants studied were classified into nontoxic category (A) whereas flammability investigation revealed that all the novel refrigerant mixtures (RM10 to RM50) were classified into flammable category (A3). CO2 emissions (TEWI) released from air conditioner working with R1270, RM30 and RM50 were 7.41%, 6.85% and 6.51%, respectively, lower than that of R22. In terms of several thermodynamic aspects, the performance of refrigerants such as R1270, RM30 and RM50 were superior to those of R22 and its various considered alternatives working under different operating conditions, although their EERs are fairly lower than R22 and hence, these refrigerants could be considered suitable environment-friendly alternatives to R22 used in air conditioners. The present study gives essential information and a road map towards the development of low GWP R22 alternative refrigerant blends from the viewpoint of toxicity, flammability, performance aspects, environmental and safety aspects, respectively.
- 18 July 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (33) , 41415-41436
Investigation on thermodynamic performance analysis and environmental effects of various new refrigerants used in air conditioners
The main aim of this present investigation is to evaluate performance and environmental impact analysis of various novel mixture refrigerants as R22 replacements theoretically. Refrigerants with lower global warming potential (GWP) can be adequate for bringing down emissions which are concerned for air conditioners. In this investigation, twenty-seven refrigerants were developed at several compositions. Important studies such as computation of CO2 emissions using total equivalent warming impact (TEWI), toxicity and flammability analysis of various considered refrigerants were also carried out in this investigation. Performance analysis of refrigerants was conducted under different operating conditions. Results showed that the energy efficiency ratios (EERs) of refrigerants such as R1270, RM30 (R152a/R1270/RE170 of 25/71/4 by mass percentage) and RM50 (R152a/R1270/RE170 of 10/85/5 by mass percentage) were closer to that of R22 and they are relatively lower than R22 by 0.95%, 1.34% and 1.80%, respectively. Toxicity investigation exhibited that all the refrigerants studied were classified into nontoxic category (A) whereas flammability investigation revealed that all the novel refrigerant mixtures (RM10 to RM50) were classified into flammable category (A3). CO2 emissions (TEWI) released from air conditioner working with R1270, RM30 and RM50 were 7.41%, 6.85% and 6.51%, respectively, lower than that of R22. In terms of several thermodynamic aspects, the performance of refrigerants such as R1270, RM30 and RM50 were superior to those of R22 and its various considered alternatives working under different operating conditions, although their EERs are fairly lower than R22 and hence, these refrigerants could be considered suitable environment-friendly alternatives to R22 used in air conditioners. The present study gives essential information and a road map towards the development of low GWP R22 alternative refrigerant blends from the viewpoint of toxicity, flammability, performance aspects, environmental and safety aspects, respectively.
- 5 September 2015
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 23 (10) , 9334-9344
Optimizing the position of insulating materials in flat roofs exposed to sunshine to gain minimum heat into buildings under periodic heat transfer conditions
Building roofs are responsible for the huge heat gain in buildings. In the present work, an analysis of the influence of insulation location inside a flat roof exposed directly to the sun’s radiation was performed to reduce heat gain in buildings. The unsteady thermal response parameters of the building roof such as admittance, transmittance, decrement factor, and time lags have been investigated by solving a one-dimensional diffusion equation under convective periodic boundary conditions. Theoretical results of four types of walls were compared with the experimental results available in literature. The results reveal that the roof with insulation placed at the outer side and at the center plane of the roof is the most energy efficient from the lower decrement factor point of view and the roof with insulation placed at the center plane and the inner side of the roof is the best from the highest time lag point of view among the seven studied configurations. The composite roof with expanded polystyrene insulation located at the outer side and at the center plane of the roof is found to be the best roof from the lowest decrement factor (0.130) point of view, and the composite roof with resin-bonded mineral wool insulation located at the center plane and at the inner side of the roof is found to be energy efficient from the highest time lag point (9.33 h) of view among the seven configurations with five different insulation materials studied. The optimum fabric energy storage thicknesses of reinforced cement concrete, expanded polystyrene, foam glass, rock wool, rice husk, resin-bonded mineral wool, and cement plaster were computed. From the results, it is concluded that rock wool has the least optimum fabric energy storage thickness (0.114 m) among the seven studied building roof materials.
- 5 September 2015
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 23 (10) , 9334-9344
Optimizing the position of insulating materials in flat roofs exposed to sunshine to gain minimum heat into buildings under periodic heat transfer conditions
Building roofs are responsible for the huge heat gain in buildings. In the present work, an analysis of the influence of insulation location inside a flat roof exposed directly to the sun’s radiation was performed to reduce heat gain in buildings. The unsteady thermal response parameters of the building roof such as admittance, transmittance, decrement factor, and time lags have been investigated by solving a one-dimensional diffusion equation under convective periodic boundary conditions. Theoretical results of four types of walls were compared with the experimental results available in literature. The results reveal that the roof with insulation placed at the outer side and at the center plane of the roof is the most energy efficient from the lower decrement factor point of view and the roof with insulation placed at the center plane and the inner side of the roof is the best from the highest time lag point of view among the seven studied configurations. The composite roof with expanded polystyrene insulation located at the outer side and at the center plane of the roof is found to be the best roof from the lowest decrement factor (0.130) point of view, and the composite roof with resin-bonded mineral wool insulation located at the center plane and at the inner side of the roof is found to be energy efficient from the highest time lag point (9.33 h) of view among the seven configurations with five different insulation materials studied. The optimum fabric energy storage thicknesses of reinforced cement concrete, expanded polystyrene, foam glass, rock wool, rice husk, resin-bonded mineral wool, and cement plaster were computed. From the results, it is concluded that rock wool has the least optimum fabric energy storage thickness (0.114 m) among the seven studied building roof materials.
- 18 July 2011
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 33 (19) , 1792-1801
An Analysis of Cycle-by-cycle Fluctuation in Combustion Parameter in CI Engine Operation for Various Bio-fuels
The cycle-by-cycle fluctuations in peak pressure of combustion in a CI engine were studied for lower and higher blends of diesel and ester, and water-in-ester emulsions, at four injection timings and three injection pressures using coefficient of variation. The sunflower ester-diesel blends are found to have lower cycle-by-cycle fluctuations than pongemia ester-diesel blends. The fluctuations are found to be higher than that of diesel for higher blend proportions of ester. The water-in-ester emulsion show higher cycle-by-cycle fluctuations than that of ester-diesel blends. In most cases, the Brake specific energy consumption is also found to be higher where the coefficient of variation has higher values.
- 18 July 2011
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 33 (19) , 1792-1801
An Analysis of Cycle-by-cycle Fluctuation in Combustion Parameter in CI Engine Operation for Various Bio-fuels
The cycle-by-cycle fluctuations in peak pressure of combustion in a CI engine were studied for lower and higher blends of diesel and ester, and water-in-ester emulsions, at four injection timings and three injection pressures using coefficient of variation. The sunflower ester-diesel blends are found to have lower cycle-by-cycle fluctuations than pongemia ester-diesel blends. The fluctuations are found to be higher than that of diesel for higher blend proportions of ester. The water-in-ester emulsion show higher cycle-by-cycle fluctuations than that of ester-diesel blends. In most cases, the Brake specific energy consumption is also found to be higher where the coefficient of variation has higher values.