Kirankumar Gorantla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kirankumar Gorantla has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Saboor Shaik
School of Mechanical Engineering, Vellore Institute of Technology, Vellore, India
4 shared publications - Aritra Ghosh
Renewable Energy, Electric and Electronic Engineering, Faculty of Environment, Science and Economy, University of Exeter, Penryn TR10 9FE, UK
1 shared publication Ashok Babu
Mechanical Engineering Department, National Institute of Technology Karnataka, Surathkal, Mangalore-575025, Karnataka, India
1 shared publication- Ashok Babu Puttranga Setty Talanki
Department of Mechanical Engineering NITK, Surathkal Mangalore-575 025
1 shared publication Ashok Setty
Natl Inst Technol Karnataka, Mech Engn Dept, Mangalore 575025, Karnataka, India
1 shared publication- Chelliah Arumugam
Department of Mechanical Engineering, Academy of Maritime Education and Traning (AMET), Deemed to be University, Chennai, India
1 shared publication
Latest Publications
- Open Access
- 11 August 2025
- Published by Springer Nature in Research Square
Towards Blockchain-Based Cybersecurity Framework for Internet of Things-Enabled Smart Infrastructure Using Feature Engineering with Quantum Deep Learning Model
The fast propagation of Internet of Things (IoT) networks in smart cities have presented many advantages such as improving urban efficacy, automation, and sustainability. However, these unified methods also pose important cybersecurity tasks, such as unauthorized access, data breaches, and cyberattacks that can deal with crucial infrastructure. As smart cities trust deeply real-time data automation and exchange, certifying the integrity, security, and confidentiality of these methods is vital. Conventional security devices, like firewalls and traditional encryption models frequently drop short owing to the spread nature and resource restraints of IoT devices. To tackle these tasks, industry specialists and researchers have developed advanced cybersecurity tactics, with blockchain (BC) technology and artificial intelligence (AI)-based models. Recently, the AI-driven security solutions permit real-world anomaly detection (AD) by analyzing cyber-attack designs and mechanizing risk mitigation events. This study presents the Secure Cybersecurity Framework for Smart Infrastructure Using Feature Engineering and Quantum Deep Learning Model (SCFSI-FEQDLM) methodology. This paper aims to propose a robust cybersecurity model for protecting IoT-based smart infrastructure using BC technology. Initially, the BC technology-based IoT is applied to enhance security, transparency, and efficiency in smart infrastructure systems. Furthermore, the data standardization applies min-max normalization to convert input data into a suitable format. Moreover, the feature selection (FS) process is performed by correlation analysis model, mutual information method, and principal component analysis technique to select the most significant features from a dataset. For the classification process, the SCFSI-FEQDLM method implements quantum long short-term memory with stochastic gradient descent optimizer for improving the classification performance. The incorporatin of feature engineering process with hyperparameter tuned quantum classification model helps in the accomplishment of improved detection rate. The experimental evaluation of the SCFSI-FEQDLM model was examined on a benchmark dataset. The extensive results highlight the significant solution of the SCFSI-FEQDLM approach when compared to recent models.
- 11 August 2025
- Published by Springer Nature in Research Square
Open AccessTowards Blockchain-Based Cybersecurity Framework for Internet of Things-Enabled Smart Infrastructure Using Feature Engineering with Quantum Deep Learning Model
The fast propagation of Internet of Things (IoT) networks in smart cities have presented many advantages such as improving urban efficacy, automation, and sustainability. However, these unified methods also pose important cybersecurity tasks, such as unauthorized access, data breaches, and cyberattacks that can deal with crucial infrastructure. As smart cities trust deeply real-time data automation and exchange, certifying the integrity, security, and confidentiality of these methods is vital. Conventional security devices, like firewalls and traditional encryption models frequently drop short owing to the spread nature and resource restraints of IoT devices. To tackle these tasks, industry specialists and researchers have developed advanced cybersecurity tactics, with blockchain (BC) technology and artificial intelligence (AI)-based models. Recently, the AI-driven security solutions permit real-world anomaly detection (AD) by analyzing cyber-attack designs and mechanizing risk mitigation events. This study presents the Secure Cybersecurity Framework for Smart Infrastructure Using Feature Engineering and Quantum Deep Learning Model (SCFSI-FEQDLM) methodology. This paper aims to propose a robust cybersecurity model for protecting IoT-based smart infrastructure using BC technology. Initially, the BC technology-based IoT is applied to enhance security, transparency, and efficiency in smart infrastructure systems. Furthermore, the data standardization applies min-max normalization to convert input data into a suitable format. Moreover, the feature selection (FS) process is performed by correlation analysis model, mutual information method, and principal component analysis technique to select the most significant features from a dataset. For the classification process, the SCFSI-FEQDLM method implements quantum long short-term memory with stochastic gradient descent optimizer for improving the classification performance. The incorporatin of feature engineering process with hyperparameter tuned quantum classification model helps in the accomplishment of improved detection rate. The experimental evaluation of the SCFSI-FEQDLM model was examined on a benchmark dataset. The extensive results highlight the significant solution of the SCFSI-FEQDLM approach when compared to recent models.
- Open Access
Energy Savings and Carbon Emission Mitigation Prospective of Building’s Glazing Variety, Window-to-Wall Ratio and Wall Thickness
Strategic selection of glazing, its window-to-wall ratio, and wall thickness of building reduce the energy consumption in the built environment. This paper presents the experimental results of solar optical properties of five glasses: clear, tinted bronze, tinted green, bronze reflective, and polymer dispersed liquid crystal glasses. Laterite room models were modeled with four different thicknesses and four different glasses using Design Builder, and thermal simulation tests were carried out using Energy Plus. The energy savings and carbon emission mitigation prospective of a building’s glazing variety, window-to-wall ratio (WWR), and wall thickness were investigated. The results revealed that among the five window glasses studied, the polymer dispersed liquid crystal glazing window (PDLCGW) was found to be the most energy-efficient for low heat gain in laterite rooms. The laterite room with 0.23 m wall thickness and 40% PDLCGW WWR reduced 18.9% heat gain in comparison with the laterite room with 0.23 m wall thickness and 40% clear glass WWR. The laterite room of 0.23 m wall thickness with PDLCGW glazing of 40% WWR enhanced cooling cost savings up to USD 31.9 compared to the laterite room of 0.08 m wall thickness with 40% PDLCGW. The laterite room of 0.23 m wall thickness with PDLCGW glazing of 40% WWR also showed improved carbon mitigation of 516 kg of CO2/year compared to the 0.23 m wall thickness laterite room of 40% WWR with clear glass glazing. The results also showed that the laterite room with 0.23 m wall thickness and 100% clear glass WWR increased heat gain by 28.2% in comparison with the laterite room with 0.23 m wall thickness and 20% clear glass WWR. The results of this article are essential for the strategic design of buildings for energy saving and emission reduction.
Open AccessEnergy Savings and Carbon Emission Mitigation Prospective of Building’s Glazing Variety, Window-to-Wall Ratio and Wall Thickness
Strategic selection of glazing, its window-to-wall ratio, and wall thickness of building reduce the energy consumption in the built environment. This paper presents the experimental results of solar optical properties of five glasses: clear, tinted bronze, tinted green, bronze reflective, and polymer dispersed liquid crystal glasses. Laterite room models were modeled with four different thicknesses and four different glasses using Design Builder, and thermal simulation tests were carried out using Energy Plus. The energy savings and carbon emission mitigation prospective of a building’s glazing variety, window-to-wall ratio (WWR), and wall thickness were investigated. The results revealed that among the five window glasses studied, the polymer dispersed liquid crystal glazing window (PDLCGW) was found to be the most energy-efficient for low heat gain in laterite rooms. The laterite room with 0.23 m wall thickness and 40% PDLCGW WWR reduced 18.9% heat gain in comparison with the laterite room with 0.23 m wall thickness and 40% clear glass WWR. The laterite room of 0.23 m wall thickness with PDLCGW glazing of 40% WWR enhanced cooling cost savings up to USD 31.9 compared to the laterite room of 0.08 m wall thickness with 40% PDLCGW. The laterite room of 0.23 m wall thickness with PDLCGW glazing of 40% WWR also showed improved carbon mitigation of 516 kg of CO2/year compared to the 0.23 m wall thickness laterite room of 40% WWR with clear glass glazing. The results also showed that the laterite room with 0.23 m wall thickness and 100% clear glass WWR increased heat gain by 28.2% in comparison with the laterite room with 0.23 m wall thickness and 20% clear glass WWR. The results of this article are essential for the strategic design of buildings for energy saving and emission reduction.
- 18 July 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (33) , 41415-41436
Investigation on thermodynamic performance analysis and environmental effects of various new refrigerants used in air conditioners
The main aim of this present investigation is to evaluate performance and environmental impact analysis of various novel mixture refrigerants as R22 replacements theoretically. Refrigerants with lower global warming potential (GWP) can be adequate for bringing down emissions which are concerned for air conditioners. In this investigation, twenty-seven refrigerants were developed at several compositions. Important studies such as computation of CO2 emissions using total equivalent warming impact (TEWI), toxicity and flammability analysis of various considered refrigerants were also carried out in this investigation. Performance analysis of refrigerants was conducted under different operating conditions. Results showed that the energy efficiency ratios (EERs) of refrigerants such as R1270, RM30 (R152a/R1270/RE170 of 25/71/4 by mass percentage) and RM50 (R152a/R1270/RE170 of 10/85/5 by mass percentage) were closer to that of R22 and they are relatively lower than R22 by 0.95%, 1.34% and 1.80%, respectively. Toxicity investigation exhibited that all the refrigerants studied were classified into nontoxic category (A) whereas flammability investigation revealed that all the novel refrigerant mixtures (RM10 to RM50) were classified into flammable category (A3). CO2 emissions (TEWI) released from air conditioner working with R1270, RM30 and RM50 were 7.41%, 6.85% and 6.51%, respectively, lower than that of R22. In terms of several thermodynamic aspects, the performance of refrigerants such as R1270, RM30 and RM50 were superior to those of R22 and its various considered alternatives working under different operating conditions, although their EERs are fairly lower than R22 and hence, these refrigerants could be considered suitable environment-friendly alternatives to R22 used in air conditioners. The present study gives essential information and a road map towards the development of low GWP R22 alternative refrigerant blends from the viewpoint of toxicity, flammability, performance aspects, environmental and safety aspects, respectively.
- 18 July 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (33) , 41415-41436
Investigation on thermodynamic performance analysis and environmental effects of various new refrigerants used in air conditioners
The main aim of this present investigation is to evaluate performance and environmental impact analysis of various novel mixture refrigerants as R22 replacements theoretically. Refrigerants with lower global warming potential (GWP) can be adequate for bringing down emissions which are concerned for air conditioners. In this investigation, twenty-seven refrigerants were developed at several compositions. Important studies such as computation of CO2 emissions using total equivalent warming impact (TEWI), toxicity and flammability analysis of various considered refrigerants were also carried out in this investigation. Performance analysis of refrigerants was conducted under different operating conditions. Results showed that the energy efficiency ratios (EERs) of refrigerants such as R1270, RM30 (R152a/R1270/RE170 of 25/71/4 by mass percentage) and RM50 (R152a/R1270/RE170 of 10/85/5 by mass percentage) were closer to that of R22 and they are relatively lower than R22 by 0.95%, 1.34% and 1.80%, respectively. Toxicity investigation exhibited that all the refrigerants studied were classified into nontoxic category (A) whereas flammability investigation revealed that all the novel refrigerant mixtures (RM10 to RM50) were classified into flammable category (A3). CO2 emissions (TEWI) released from air conditioner working with R1270, RM30 and RM50 were 7.41%, 6.85% and 6.51%, respectively, lower than that of R22. In terms of several thermodynamic aspects, the performance of refrigerants such as R1270, RM30 and RM50 were superior to those of R22 and its various considered alternatives working under different operating conditions, although their EERs are fairly lower than R22 and hence, these refrigerants could be considered suitable environment-friendly alternatives to R22 used in air conditioners. The present study gives essential information and a road map towards the development of low GWP R22 alternative refrigerant blends from the viewpoint of toxicity, flammability, performance aspects, environmental and safety aspects, respectively.
- 30 March 2018
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 36 (1) , 252-260
Thermal and cost analysis of float and various tinted double window glass configurations on heat gain into buildings of hot & dry climatic zone in India
- 30 March 2018
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 36 (1) , 252-260
Thermal and cost analysis of float and various tinted double window glass configurations on heat gain into buildings of hot & dry climatic zone in India
- Open Access
- 9 January 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 144, 04008
Effect of Various External Shading Devices on Windows for Minimum Heat Gain and Adequate Day lighting into Buildings of Hot and Dry Climatic Zone in India
Glass is the major component of the building envelope to provide visual comfort to inside the buildings. In général clear and bronze glass was used as a main building envelope for both residential and commercial buildings to provide better day lighting into the buildings. If we use more glass area as a building envelope more radiation allows into the buildings. So that it is necessary to reduce more solar radiation and provide sufficient daylight factor inside the building's through glass windows with the help of external devices called shading devices. In this work four shading devices was tried on bronze glass window to find the heat gain and daylighting into buildings. This paper presents the experimental measurement of spectral characteristics of bronze glass which include transmission and reflection in entire solar spectrum region (300nm-2500nm) based on ASTM standards. A MATLAB code was developed to compute visible and solar optical properties as per the British standards. A building model was designed by design builder software tool. 40% window to wall ratio was considered for building models, thermal and day lighting analysis of buildings through windows was carried out in Energy plus software tool for hot and dry climatic zone of India.
- 9 January 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 144, 04008
Open AccessEffect of Various External Shading Devices on Windows for Minimum Heat Gain and Adequate Day lighting into Buildings of Hot and Dry Climatic Zone in India
Glass is the major component of the building envelope to provide visual comfort to inside the buildings. In général clear and bronze glass was used as a main building envelope for both residential and commercial buildings to provide better day lighting into the buildings. If we use more glass area as a building envelope more radiation allows into the buildings. So that it is necessary to reduce more solar radiation and provide sufficient daylight factor inside the building's through glass windows with the help of external devices called shading devices. In this work four shading devices was tried on bronze glass window to find the heat gain and daylighting into buildings. This paper presents the experimental measurement of spectral characteristics of bronze glass which include transmission and reflection in entire solar spectrum region (300nm-2500nm) based on ASTM standards. A MATLAB code was developed to compute visible and solar optical properties as per the British standards. A building model was designed by design builder software tool. 40% window to wall ratio was considered for building models, thermal and day lighting analysis of buildings through windows was carried out in Energy plus software tool for hot and dry climatic zone of India.