I. Yamada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
I. Yamada has a total of 295 co-authors. Here are the top co-authors by number of shared publications:
- K. Toi
National Institute for Fusion Science, Toki, Japan
12 shared publications - Katsumi Ida
National Institute for Fusion Science, National Institutes of Natural Sciences 1 , Toki 509-5292
12 shared publications - Shigeru Inagaki
Kyushu University
12 shared publications - M. Emoto
National Institute for Fusion Science, Toki, Gifu 509-5292, Japan
11 shared publications - Masaki Osakabe
National Institute for Fusion Science
11 shared publications - Naoki Tamura
Max-Planck Institute for Plasmaphysics
11 shared publications
Latest Publications
- 30 July 2015
- Published by IOP Publishing in Nuclear Fusion
- Vol. 55 (10) , 104018
Overview of transport and MHD stability study: focusing on the impact of magnetic field topology in the Large Helical Device
- 30 July 2015
- Published by IOP Publishing in Nuclear Fusion
- Vol. 55 (10) , 104018
Overview of transport and MHD stability study: focusing on the impact of magnetic field topology in the Large Helical Device
- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10D522
Improvements of data quality of the LHD Thomson scattering diagnostics in high-temperature plasma experiments
In Large Helical Device (LHD) experiments, an electron temperature more than 15 keV has been observed by the yttrium-aluminum-garnet (YAG) laser Thomson scattering diagnostic. Since the LHD Thomson scattering system has been optimized for the temperature region, , the data quality becomes worse in the higher region exceeding 10 keV. In order to accurately determine in the LHD high- experiments, we tried to increase the laser pulse energy by simultaneously firing three lasers. The technique enables us to decrease the uncertainties in the measured . Another signal accumulation method was also tested. In addition, we estimated the influence of high-energy electrons on obtained by the LHD Thomson scattering system.- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10D522
Improvements of data quality of the LHD Thomson scattering diagnostics in high-temperature plasma experiments
In Large Helical Device (LHD) experiments, an electron temperature more than 15 keV has been observed by the yttrium-aluminum-garnet (YAG) laser Thomson scattering diagnostic. Since the LHD Thomson scattering system has been optimized for the temperature region, , the data quality becomes worse in the higher region exceeding 10 keV. In order to accurately determine in the LHD high- experiments, we tried to increase the laser pulse energy by simultaneously firing three lasers. The technique enables us to decrease the uncertainties in the measured . Another signal accumulation method was also tested. In addition, we estimated the influence of high-energy electrons on obtained by the LHD Thomson scattering system.- 28 August 2003
- Published by IOP Publishing in Nuclear Fusion
- Vol. 43 (9) , 899-909
Experimental study on ion temperature behaviours in ECH, ICRF and NBI H2, He and Ne discharges of the Large Helical Device
Ion heating experiments have been carried out in the large helical device using ECH (82.5, 84.0, 168 GHz, ≤1 MW), ICRF (38.5 MHz, ≤2.7 MW) and NBI (H° beam: 160 keV, ≤9 MW). The central ion temperature has been observed from the Doppler broadening of Ti XXI (2.61 Å) and Ar XVII (3.95 Å) x-ray lines, which are measured using a newly installed crystal spectrometer with a charge-coupled device. Recently, in ECH discharges, on-axis heating became possible. As a result, a high Te(0) of 6–10 keV and a high ion temperature of 2.2 keV were obtained at ne = 0.6×1013 cm−3. A clear increment of Ti was also observed with the enhancement of the electron–ion energy flow when the ECH pulse was added to the NBI discharge. These results demonstrate the feasibility towards ECH ignition. A clear Ti increment was observed also in ICRF discharges at low density ranges of (0.4–0.6)×1013 cm−3 with appearance of a new operational range of Ti(0) = 2.8 keV > Te(0) = 1.9 keV. In low power ICRF heating (1 MW), the fraction of bulk ion heating is estimated to be 60% of the total ICRF input power, which means Pi>Pe. Higher Ti(0), up to 3.5 keV, was obtained for a combined heating of NBI (13 cm−3. The highest Ti(0) of 5 keV was recorded in Ne NBI discharges at ne13 cm−3 with the achievement of Ti(0)>Te(0), whereas the Ti(0) remained at relatively low values of 2 keV in H2 and He NBI discharges due to less Pi. The main reasons for the high Ti achievement in the Ne discharges are: (1) 30% increment of deposition power, (2) increase in Pi/ni (five times, Pi/niPe/ne, Pi<Pe) and (3) increase in τei (three times). The obtained Ti(0) data can be plotted by a smooth function of Pi/ni. This result strongly suggests that the ion temperature increases even in the H2 discharge if the Pi can be raised up.
- 28 August 2003
- Published by IOP Publishing in Nuclear Fusion
- Vol. 43 (9) , 899-909
Experimental study on ion temperature behaviours in ECH, ICRF and NBI H2, He and Ne discharges of the Large Helical Device
Ion heating experiments have been carried out in the large helical device using ECH (82.5, 84.0, 168 GHz, ≤1 MW), ICRF (38.5 MHz, ≤2.7 MW) and NBI (H° beam: 160 keV, ≤9 MW). The central ion temperature has been observed from the Doppler broadening of Ti XXI (2.61 Å) and Ar XVII (3.95 Å) x-ray lines, which are measured using a newly installed crystal spectrometer with a charge-coupled device. Recently, in ECH discharges, on-axis heating became possible. As a result, a high Te(0) of 6–10 keV and a high ion temperature of 2.2 keV were obtained at ne = 0.6×1013 cm−3. A clear increment of Ti was also observed with the enhancement of the electron–ion energy flow when the ECH pulse was added to the NBI discharge. These results demonstrate the feasibility towards ECH ignition. A clear Ti increment was observed also in ICRF discharges at low density ranges of (0.4–0.6)×1013 cm−3 with appearance of a new operational range of Ti(0) = 2.8 keV > Te(0) = 1.9 keV. In low power ICRF heating (1 MW), the fraction of bulk ion heating is estimated to be 60% of the total ICRF input power, which means Pi>Pe. Higher Ti(0), up to 3.5 keV, was obtained for a combined heating of NBI (13 cm−3. The highest Ti(0) of 5 keV was recorded in Ne NBI discharges at ne13 cm−3 with the achievement of Ti(0)>Te(0), whereas the Ti(0) remained at relatively low values of 2 keV in H2 and He NBI discharges due to less Pi. The main reasons for the high Ti achievement in the Ne discharges are: (1) 30% increment of deposition power, (2) increase in Pi/ni (five times, Pi/niPe/ne, Pi<Pe) and (3) increase in τei (three times). The obtained Ti(0) data can be plotted by a smooth function of Pi/ni. This result strongly suggests that the ion temperature increases even in the H2 discharge if the Pi can be raised up.
- 8 July 2003
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 669 (1) , 187
ECH Power Deposition Study in the Collisionless Plasma of LHD
Power deposition profile is one of the essential keys in understanding the transport mechanism in high temperature low collisional plasma. Using the power modulation techniques, the power deposition profile and its change in shape and position by the focal position is clearly observed experimentally in Large Helical Device (LHD). These power deposition profiles show fairly in good agreement with the results from ray tracing calculation, as well as discrepancies arising from supra thermal electrons. Such experimentally deduced power deposition profiles are used as the initial inputs of one dimensional time dependent electron transport code for the further investigation of the plasma confinement.
- 8 July 2003
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 669 (1) , 187
ECH Power Deposition Study in the Collisionless Plasma of LHD
Power deposition profile is one of the essential keys in understanding the transport mechanism in high temperature low collisional plasma. Using the power modulation techniques, the power deposition profile and its change in shape and position by the focal position is clearly observed experimentally in Large Helical Device (LHD). These power deposition profiles show fairly in good agreement with the results from ray tracing calculation, as well as discrepancies arising from supra thermal electrons. Such experimentally deduced power deposition profiles are used as the initial inputs of one dimensional time dependent electron transport code for the further investigation of the plasma confinement.
- 30 May 2003
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 45 (7) , 1183-1192
Formation of electron internal transport barriers by highly localized electron cyclotron resonance heating in the large helical device
Internal transport barriers with respect to electron thermal transport (eITB) were observed in the large helical device, when the electron cyclotron resonance heating (ECH) power was highly localized on the centre of a plasma sustained by neutral beam injection. The eITB is characterized by a high central electron temperature of 6–8 keV with an extremely steep gradient, as high as 55 keV m−1 and a low electron thermal diffusivity within a normalized average radius ρ≈0.3 as well as by the existence of clear thresholds for the ECH power and plasma collisionality.
- 30 May 2003
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 45 (7) , 1183-1192
Formation of electron internal transport barriers by highly localized electron cyclotron resonance heating in the large helical device
Internal transport barriers with respect to electron thermal transport (eITB) were observed in the large helical device, when the electron cyclotron resonance heating (ECH) power was highly localized on the centre of a plasma sustained by neutral beam injection. The eITB is characterized by a high central electron temperature of 6–8 keV with an extremely steep gradient, as high as 55 keV m−1 and a low electron thermal diffusivity within a normalized average radius ρ≈0.3 as well as by the existence of clear thresholds for the ECH power and plasma collisionality.
- 30 May 2003
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 45 (7) , 1127-1142
Recent diagnostic developments on LHD
The recent diagnostic developments on the large helical device (LHD) are described briefly. LHD is the largest helical machine with all superconducting coils, and its purpose is to prove the ability of a helical system to confine a fusion-relevant plasma in steady state. According to the missions of LHD research, the diagnostic devices are categorized as follows: diagnostics for (i) high nτET plasmas and transport physics; (ii) magnetohydrodynamic stability; (iii) long pulse operation and divertor function; and (iv) energetic particles. These are briefly described focusing on the recent developments of the devices. Since the LHD experiment started in March 1998, five series of experimental campaigns have been carried out. The LHD diagnostics during these periods were operated successfully, and contributed to the analysis of the experimental results.
- 30 May 2003
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 45 (7) , 1127-1142
Recent diagnostic developments on LHD
The recent diagnostic developments on the large helical device (LHD) are described briefly. LHD is the largest helical machine with all superconducting coils, and its purpose is to prove the ability of a helical system to confine a fusion-relevant plasma in steady state. According to the missions of LHD research, the diagnostic devices are categorized as follows: diagnostics for (i) high nτET plasmas and transport physics; (ii) magnetohydrodynamic stability; (iii) long pulse operation and divertor function; and (iv) energetic particles. These are briefly described focusing on the recent developments of the devices. Since the LHD experiment started in March 1998, five series of experimental campaigns have been carried out. The LHD diagnostics during these periods were operated successfully, and contributed to the analysis of the experimental results.
- 27 May 2003
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 45 (6) , 1037-1050
Confinement characteristics of high-energy ions produced by ICRF heating in the large helical device
The behaviour of high-energy ions accelerated by an ion cyclotron range of frequency (ICRF) electric field in the large helical device (LHD) is discussed. A better confinement performance of high-energy ions in the inward-shifted magnetic axis configuration was experimentally verified by measuring their energy spectrum and comparing it with the effective temperature determined by an electron slowing down process. In the standard magnetic axis configuration a saturation of the measured tail temperature was observed as the effective temperature was increased. The ratio between these two quantities is a measure of the quality of transfer efficiency from high-energy ions to a bulk plasma; when this efficiency was compared with Monte Carlo simulations the results agreed fairly well. The ratio of the stored energy of the high-energy ions to that of the bulk plasma was measured using an ICRF heating power modulation method; it was deduced from phase differences between total and bulk plasma stored energies and the modulated ICRF heating power. The measured high energy fraction agreed with that calculated using the injected ICRF heating power, the transfer efficiency determined in the experiment and the confinement scaling of the LHD plasma.
- 27 May 2003
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 45 (6) , 1037-1050
Confinement characteristics of high-energy ions produced by ICRF heating in the large helical device
The behaviour of high-energy ions accelerated by an ion cyclotron range of frequency (ICRF) electric field in the large helical device (LHD) is discussed. A better confinement performance of high-energy ions in the inward-shifted magnetic axis configuration was experimentally verified by measuring their energy spectrum and comparing it with the effective temperature determined by an electron slowing down process. In the standard magnetic axis configuration a saturation of the measured tail temperature was observed as the effective temperature was increased. The ratio between these two quantities is a measure of the quality of transfer efficiency from high-energy ions to a bulk plasma; when this efficiency was compared with Monte Carlo simulations the results agreed fairly well. The ratio of the stored energy of the high-energy ions to that of the bulk plasma was measured using an ICRF heating power modulation method; it was deduced from phase differences between total and bulk plasma stored energies and the modulated ICRF heating power. The measured high energy fraction agreed with that calculated using the injected ICRF heating power, the transfer efficiency determined in the experiment and the confinement scaling of the LHD plasma.
- 22 April 2003
- Published by AIP Publishing in Physics of Plasmas
- Vol. 10 (5) , 1788-1795
Formation of electron internal transport barrier and achievement of high ion temperature in Large Helical Device
An internal transport barrier (ITB) was observed in the electron temperature profile in the Large Helical Device [O. Motojima et al., Phys. Plasmas 6, 1843 (1999)] with a centrally focused intense electron cyclotron resonance microwave heating. Inside the ITB the core electron transport was improved, and a high electron temperature, exceeding 10 keV in a low density, was achieved in a collisionless regime. The formation of the electron-ITB is correlated with the neoclassical electron root with a strong radial electric field determined by the neoclassical ambipolar flux. The direction of the tangentially injected beam-driven current has an influence on the electron-ITB formation. For the counter-injected target plasma, a steeper temperature gradient, than that for the co-injected one, was observed. As for the ion temperature, high-power NBI (neutral beam injection) heating of 9 MW has realized a central ion temperature of 5 keV with neon injection. By introducing neon gas, the NBI absorption power was increased in low-density plasmas and the direct ion heating power was much enhanced with a reduced number of ions, compared with hydrogen plasmas.
- 22 April 2003
- Published by AIP Publishing in Physics of Plasmas
- Vol. 10 (5) , 1788-1795
Formation of electron internal transport barrier and achievement of high ion temperature in Large Helical Device
An internal transport barrier (ITB) was observed in the electron temperature profile in the Large Helical Device [O. Motojima et al., Phys. Plasmas 6, 1843 (1999)] with a centrally focused intense electron cyclotron resonance microwave heating. Inside the ITB the core electron transport was improved, and a high electron temperature, exceeding 10 keV in a low density, was achieved in a collisionless regime. The formation of the electron-ITB is correlated with the neoclassical electron root with a strong radial electric field determined by the neoclassical ambipolar flux. The direction of the tangentially injected beam-driven current has an influence on the electron-ITB formation. For the counter-injected target plasma, a steeper temperature gradient, than that for the co-injected one, was observed. As for the ion temperature, high-power NBI (neutral beam injection) heating of 9 MW has realized a central ion temperature of 5 keV with neon injection. By introducing neon gas, the NBI absorption power was increased in low-density plasmas and the direct ion heating power was much enhanced with a reduced number of ions, compared with hydrogen plasmas.
- 26 November 2001
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 43 (12A) , A55-A71
Configuration flexibility and extended regimes in Large Helical Device
Recent experimental results in the Large Helical Device have indicated that a large pressure gradient can be formed beyond the stability criterion for the Mercier (high-n) mode. While the stability against an interchange mode is violated in the inward-shifted configuration due to an enhancement of the magnetic hill, the neoclassical transport and confinement of high-energy particle are, in contrast, improved by this inward shift. Mitigation of the unfavourable effects of MHD instability has led to a significant extension of the operational regime. Achievements of the stored energy of 1 MJ and the volume-averaged beta of 3% are representative results from this finding. A confinement enhancement factor above the international stellarator scaling ISS95 is also maintained around 1.5 towards a volume-averaged beta, β , of 3%. Configuration studies on confinement and MHD characteristics emphasize the superiority of the inward-shifted geometry to other geometries. The emergence of coherent modes appears to be consistent with the linear ideal MHD theory; however, the inward-shifted configuration has reduced heat transport in spite of a larger amplitude of magnetic fluctuation than the outward-shifted configuration. While neoclassical helical ripple transport becomes visible for the outward-shifted configuration in the collisionless regime, the inward-shifted configuration does not show any degradation of confinement deep in the collisionless regime (ν*<0.1). The distinguished characteristics observed in the inward-shifted configuration help in creating a new perspective of MHD stability and related transport in net current-free plasmas. The first result of the pellet launching at different locations is also reported.
- 26 November 2001
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 43 (12A) , A55-A71
Configuration flexibility and extended regimes in Large Helical Device
Recent experimental results in the Large Helical Device have indicated that a large pressure gradient can be formed beyond the stability criterion for the Mercier (high-n) mode. While the stability against an interchange mode is violated in the inward-shifted configuration due to an enhancement of the magnetic hill, the neoclassical transport and confinement of high-energy particle are, in contrast, improved by this inward shift. Mitigation of the unfavourable effects of MHD instability has led to a significant extension of the operational regime. Achievements of the stored energy of 1 MJ and the volume-averaged beta of 3% are representative results from this finding. A confinement enhancement factor above the international stellarator scaling ISS95 is also maintained around 1.5 towards a volume-averaged beta, β , of 3%. Configuration studies on confinement and MHD characteristics emphasize the superiority of the inward-shifted geometry to other geometries. The emergence of coherent modes appears to be consistent with the linear ideal MHD theory; however, the inward-shifted configuration has reduced heat transport in spite of a larger amplitude of magnetic fluctuation than the outward-shifted configuration. While neoclassical helical ripple transport becomes visible for the outward-shifted configuration in the collisionless regime, the inward-shifted configuration does not show any degradation of confinement deep in the collisionless regime (ν*<0.1). The distinguished characteristics observed in the inward-shifted configuration help in creating a new perspective of MHD stability and related transport in net current-free plasmas. The first result of the pellet launching at different locations is also reported.
- 1 May 2001
- Published by IOP Publishing in Nuclear Fusion
- Vol. 41 (5) , 519-525
Role of core radiation during slow oscillations in LHD
During experiments in LHD using stainless steel divertor plates, a slow (~1 s) cyclic oscillation in the plasma parameters known as `breathing' plasma was observed during NBI heated long pulse discharges. Using an average ion, corona equilibrium model for the iron impurity cooling rate, the iron impurity density profile is calculated for 0.0 <ρ<0.8 from the measured electron temperature and density profiles and radiation profile data for these discharges in LHD. This calculated iron density oscillates out of phase with the electron density and peaks near ρ = 0.4 at a fraction of the electron density that varies by a factor of 4. This is in qualitative agreement with spectroscopic measurements of iron that show a similar oscillation. The correlation of the iron impurity concentration with the change in electron temperature and with the local power balance between radiation and beam deposition indicates that when radiation from the iron impurity dominates the local power balance the core plasma is cooled. The increase in the calculated iron density during the phase of the oscillation when the divertor electron temperature exceeds the sputtering threshold suggests that sputtering of the stainless steel divertor plate may be the source of the iron impurity. Evidence of changing transport points to the need for a closer examination of the role of impurity transport in this oscillation.
- 1 May 2001
- Published by IOP Publishing in Nuclear Fusion
- Vol. 41 (5) , 519-525
Role of core radiation during slow oscillations in LHD
During experiments in LHD using stainless steel divertor plates, a slow (~1 s) cyclic oscillation in the plasma parameters known as `breathing' plasma was observed during NBI heated long pulse discharges. Using an average ion, corona equilibrium model for the iron impurity cooling rate, the iron impurity density profile is calculated for 0.0 <ρ<0.8 from the measured electron temperature and density profiles and radiation profile data for these discharges in LHD. This calculated iron density oscillates out of phase with the electron density and peaks near ρ = 0.4 at a fraction of the electron density that varies by a factor of 4. This is in qualitative agreement with spectroscopic measurements of iron that show a similar oscillation. The correlation of the iron impurity concentration with the change in electron temperature and with the local power balance between radiation and beam deposition indicates that when radiation from the iron impurity dominates the local power balance the core plasma is cooled. The increase in the calculated iron density during the phase of the oscillation when the divertor electron temperature exceeds the sputtering threshold suggests that sputtering of the stainless steel divertor plate may be the source of the iron impurity. Evidence of changing transport points to the need for a closer examination of the role of impurity transport in this oscillation.