PBP. M. Bell

P. M. Bell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


P. M. Bell has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Performance measurements of the DIXI (dilation x-ray imager) photocathode using a laser produced x-ray source

    by Sabrina R. Nagel, M. J. Ayers, B. Felker, T. J. Hilsabeck, T. Chung, R. F. Smith, P. M. Bell, D. K. Bradley, G. W. Collins, J. D. Kilkenny, et al.

    DIXI (dilation x-ray imager) will be used to characterize ICF (inertial confinement fusion) implosions on the NIF. DIXI utilizes pulse-dilation technology1 to achieve x-ray imaging with temporal gate times below 10 ps. Time resolved x-ray measurements were conducted using the COMET laser facility at the Lawrence Livermore National Laboratory. Here we focus on some of the challenges faced by the large aperture photo cathode of the instrument and report on how to maintain a at photo cathode as well as how the required spatial resolution of the instrument is achieved.


  • Design and testing of a mega pixel CMOS charge dump and read camera

    by Joseph R. Kimbrough, J. D. Moody, P. M. Bell

    The National Ignition Facility requires a radiation-hardened, megapixel CMOS imaging sensor-based camera to be a direct physical and operational replacement for the CCD cameras currently used in x-ray streak cameras and gated imaging detectors. The first phase is a radiation-tolerant camera for characterization of radiation effects on the imaging sensor. This will be followed by a fully hardened version. The radiation-tolerant camera, based on the 2k by 2k CMV4000 sensor from CMOSIS Inc., has been built and optical performance was measured. Camera parts were selected to operate up to 10 krad(Si) and the camera incorporates a fast charge and dump of the sensor pixels, followed by image readout. This allows the dumping of charge due to the prompt radiation noise and then readout of the longer persistence phosphor signal from the x-ray diagnostics.


  • Measuring x-ray burn history with the Streaked Polar Instrumentation for Diagnosing Energetic Radiation (SPIDER) at the National Ignition Facility (NIF)

    by S. F. Khan, P. M. Bell, D. K. Bradley, S. R. Burns, J. R. Celeste, L. S. Dauffy, M. J. Eckart, M. A. Gerhard, C. Hagmann, D. I. Headley, et al.

    We present a new diagnostic for the National Ignition Facility (NIF) [1,2]. The Streaked Polar Instrumentation for Diagnosing Energetic Radiation (SPIDER) is an x-ray streak camera for use on almost-igniting targets, up to ~1017 neutrons per shot. It measures the x-ray burn history for ignition campaigns with the following requirements: X-Ray Energy 8-30keV, Temporal Resolution 10ps, Absolute Timing Resolution 30ps, Neutron Yield: 1014 to 1017. The features of the design are a heavily shielded instrument enclosure outside the target chamber, remote location of the neutron and EMP sensitive components, a precise laser pulse comb fiducial timing system and fast streaking electronics. SPIDER has been characterized for sweep linearity, dynamic range, temporal and spatial resolution. Preliminary DT implosion data shows the functionality of the instrument and provides an illustration of the method of burn history extraction.


  • Efficiency and decay time measurement of phosphors for x-ray framing cameras usable in harsh radiation background

    by N. Izumi, J. Emig, J. Moody, C. Middleton, J. Holder, K. Piston, V. Smalyuk, C. Hagmann, J. Ayers, J. Celeste, et al.

    Phosphors are key components of x-ray framing cameras. On implosion experiments at the National Ignition Facility, the x-ray framing cameras must operate in a harsh neutron induced ionizing radiation. One promising approach of neutron induced background reduction is separation of the neutron background with using difference of x-ray and neutron time-of- flight. To complete x-ray imaging before arrival of the neutron induced radiation to the detector, it is crucial to find a phosphor which has high efficiency and fast decay time. We tested various phosphor materials to optimize design of framing cameras for implosion experiments.


  • Radiation induced noise in x-ray imagers for high-yield inertial confinement fusion experiments

    by C. Hagmann, J. Ayers, P. M. Bell, J.-L. Bourgade, D. K. Bradley, J. Celeste, C. Cerjan, S. Darbon, J. Emig, B. Felker, et al.

    The large fluence of 14-MeV neutrons produced in high-yield inertial confinement fusion (ICF) experiments creates a variety of backgrounds in x-ray imagers viewing the implosion. Secondary charged particles produce background light by Cherenkov emission, phosphor screen excitation and possibly scintillation in the optical components of the imager. In addition, radiation induced optical absorption may lead to attenuation of the signal. Noise is also produced directly in the image recorder itself (CCD or film) via energy deposition by electrons and heavy charged particles such as protons and alphas. We will present results from CCD background measurements and compare them to Monte Carlo calculations. In addition we show measurements of luminescence and long-term darkening for some of the glasses employed in imagers.


  • Radiation hardening of gated x-ray imagers for the National Ignition Facility (invited)

    by P. M. Bell, D. K. Bradley, J. D. Kilkenny, A. Conder, C. Cerjan, C. Hagmann, D. Hey, N. Izumi, J. Moody, A. Teruya, et al.

    The National Ignition Facility will soon be producing x-ray flux and neutron yields higher than any produced in laser driven implosion experiments in the past. Even a non-igniting capsule will require x-ray imaging of near burning plasmas at 1017 neutrons, requiring x-ray recording systems to work in more hostile conditions than we have encountered in past laser facilities. We will present modeling, experimental data and design concepts for x-ray imaging with electronic recording systems for this environment (ARIANE). A novel instrument, active readout in a nuclear environment, is described which uses the time-of-flight difference between the gated x-ray signal and the neutron which induces a background signal to increase the yield at which gated cameras can be used.


  • Further development of a single line of sight x-ray framing camera

    by J. P. Holder, K. W. Piston, D. K. Bradley, P. M. Bell, A. K. L. Dymoke-Bradshaw, J. D. Hares

    High-speed microchannel plate (MCP) x-ray framing cameras are a well established diagnostic for laser plasma experiments. Each frame acquired with these devices requires a separate image, and with most reasonable x-ray optics, a separate line of sight, causing potential parallax problems. Gated image tubes have a single line of sight capability, but the conventional designs have not been effectively extended to the short gating times of the microstrip MCP camera. A hybrid camera combining image tube and microstrip MCP technology has been under development at Lawrence Livermore National Laboratory in collaboration with the University of Rochester, Laboratory for Laser Energetics, and KENTECH Instruments. Characterization measurements using laser generated plasma x rays are presented. Simulations as a guide to improving this hybrid camera are also presented.


  • Comparison of charge coupled device vs film readouts for gated micro-channel plate cameras

    by R. E. Turner, O. L. Landen, D. K. Bradley, S. S. Alvarez, P. M. Bell, R. Costa, J. D. Moody, D. Lee

    We have used a large format (4000×4000) high resolution (9 μm pixels) charge coupled device (CCD) to record images from the rear of a gated micro-channel plate (MCP) intensifier, and compared the results with conventional film recording. Measurements of linearity, dynamic range, dark noise, and distortion all show that the CCD is a superior replacement for film. Furthermore, its excellent registration allows for easy flat fielding, using data from a uniformly exposed MCP. As we increase the signal level to where the signal to noise is not dominated by photon counting statistics, we find that this flat fielding procedure produces a significant improvement in signal to noise. The small spatial scale of this noise has led to its identification as high spatial frequency variations in the MCP phosphor.


  • Development and characterization of a single-line-of-sight framing camera

    by D. K. Bradley, P. M. Bell, A. K. L. Dymoke-Bradshaw, J. D. Hares, R. E. Bahr, V. A. Smalyuk, D. R. Hargrove, K. Piston

    We present initial characterization data from a new single-line-of-sight (SLOS) x-ray framing camera. The instrument uses an image-dissecting structure inside an electron optic tube to produce up to four simultaneous dc images from a single image incident on the cathode and a microchannel plate-based device to provide the temporal gating of those images. A series of gated images have been obtained using a short-pulse UV laser source, and the spatial resolution of those images is compared to those obtained using a more traditional-microchannel plate based system.


  • Characterization of Nova plasmas using an x-ray spectrometer with temporal and spatial resolution

    by C. A. Back, R. L. Kauffman, P. M. Bell, J. D. Kilkenny

    Spectroscopic diagnostics have great potential to obtain high temperature measurements of plasmas created in inertial confinement fusion targets. The plasmas may be over 1 mm in size and therefore, one of the first steps in making better spectroscopic measurements has been to develop a spectrograph which takes advantage of gated technology by coupling a Bragg crystal to a microchannel plate. The crystal disperses the x rays, while slits add the ability to image the plasmas in the perpendicular direction. The characteristics of this diagnostic, TSPEC, are evaluated for laser‐produced plasmas. Recent data will be presented from colliding plasmas and large‐scale hohlraums which indicate that imaging can greatly enhance the ability to diagnose these plasmas.