KMKaan Manisa

Kaan Manisa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kaan Manisa has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of Radiation Shielding Properties of Samarium Oxide Doped Photopolymer Composites for Additive Manufacturing Applications

    by Sara Ahmed Zaynal, Penbe Nur Ülgen, Selami Eken, Meryem Cansu Şahin, Kaan Manisa

    The need for cutting-edge and environmentally shielding materials to reduce radiation exposure has grown along with the use of nuclear energy due to scientific and industrial developments. The gamma attenuation characteristics of samarium oxide (Sm2O3)-doped photopolymer composites created for additive manufacturing applications are examined in this work. This study involved the theoretical design of resin structures that contained 0%, 10%, 20%, and 50% Sm2O3 by weight. The GAMOS Monte Carlo simulation code was used to examine the materials' radiation interaction parameters at gamma energies ranging from 81 keV to 1408 keV. The results showed that as the dopant concentration increased, the linear attenuation coefficient (LAC) and mass attenuation coefficient (MAC) increased significantly, while the half-value layer (HVL) thickness decreased. Specifically, at the low energy level of 81 keV, the Sm50 sample containing 50% Sm2O3 exhibited the highest radiation attenuation performance compared to the undoped sample. Consequently, samarium-doped composites produced using 3D printing technology offer high potential for lightweight and lead-free radiation shielding equipment with complex geometries.


  • Open Access

    Investigation of gamma radiation absorption parameters and comfort properties of woven fabrics with hybrid yarns containing Haynes 25/L625 alloy

    by Meryem Cansu Şahin, Nilüfer Ünay Çubukçu, Eren Öner, Hasan Bircan, Kaan Manisa

    The increasing reliance on X-rays and gamma radiation in healthcare has given rise to a demand for shielding materials that are lightweight, flexible, and free from toxicity. These materials are being developed as substitutes for conventional lead aprons, which are bulky, rigid, and hazardous. In this research, woven textiles produced from hybrid yarns containing Haynes 25/L625 alloy wires and recycled cotton/polyester blends were investigated as a candidate solution, focusing on both radiation attenuation and user comfort. Three weave structures-plain, 3/1 twill, and 5-harness satin-were manufactured by interlacing alloy wires with cotton/polyester yarns. The gamma-ray shielding capability of the materials was examined across a range of 15 photon energies, from 32 to 1408 keV, utilizing a NaI(Tl) scintillation detector. The evaluation encompassed various parameters, including transmission, absorption, linear and mass attenuation coefficients, half-value layer, and shielding effectiveness. A comprehensive characterization of the material’s comfort-related properties was conducted, encompassing parameters such as air permeability, which was measured in accordance with the ISO 9237 standard, porosity, and thermal behavior. The satin weave, which incorporates the highest proportion of alloy, exhibited enhanced attenuation, particularly at lower photon energies, with a mass attenuation coefficient of 6.649 cm 2 /g at 32 keV. The twill fabric demonstrated improved performance at intermediate and higher energies, exhibiting a linear attenuation coefficient of 0.291 cm −1 at 356 keV. In comparison, the plain weave provided the least effective protection. In terms of comfort, the satin and twill structures exhibited higher breathability and porosity, with values of 22% and 19%, respectively, attributable to their more open geometries. In contrast, the plain weave demonstrated reduced air permeability, with 12% porosity, but enhanced thermal dissipation efficiency. The satin weave is optimal for achieving maximum attenuation, while the twill weave provides a balanced compromise with high performance.


  • Open Access

    Experimental, theoretical, and biological investigations on radiation shielding parameters of boron-doped cerrobend alloys

    by Meryem Cansu Sahin, Kaan Manisa, Hasan Bircan, Suna Karadeniz Saygili

    This experimental and theoretical study investigated the efficiency of radiation absorption by Cerrobend alloy with varying concentrations of B4C compound. Four blocks were prepared containing 0%, 5%, 10%, and 15% B4C, respectively. The study examined radiation attenuation characteristics, including the mass attenuation coefficient, linear attenuation coefficient, half-value layer thickness, and mean free path, as well as radiobiological consequences for each block, using photon energies of 6 and 15 MeV. It has been observed that the rise in the quantity of B4C leads to a decrease in the material’s ability to absorb photons. The highest mass attenuation coefficient at 6 MeV energy was S1 with 0.0432 cm2/g. The half-value layer of samples S2 and S3 exhibited a larger magnitude compared to samples S1. The tenth-value layer findings obtained with photons with 15 MeV energy were S0 < S1 < S2 < S3. In the experiments with photons with 6 MeV energy, the mean free path value of sample S1 was relatively lower than other samples. The experimental results were consistent with the data obtained from GAMOS and XCOM. Experiments and theoretical studies have shown that the Cerrobend alloy’s photon absorption properties are very similar to those of pure Cerrobend when it is doped with 5 wt% B4C.


  • Open Access

    Evaluation of X-Ray Shielding Ability of Tungsten Rubber: A GAMOS Monte Carlo Study

    by Meryem Cansu Şahi̇n, Kaan Mani̇sA

    Against the detrimental effects of ionizing radiation, time, distance, and shielding are the three most significant protective methods. Lead is the material of choice for shielding, particularly for personal protective equipment. However, lead's density, rigidity, and toxicity are significant disadvantages. In recent years, tungsten-containing rubber (TCR) and other lightweight, flexible, and non-toxic shielding materials have emerged as viable alternatives to lead. The purpose of this study is to examine the X-ray absorption capacity of TCR material, which can serve as an alternative to lead-based personal protective equipment. Using GAMOS simulation, radiation absorption characteristics for 11 different X-ray energies ranging from 30 to 1000 keV were obtained and compared with Phy-X/PSD data. While the MFP value produced from the GAMOS code for the TCR with 100 keV energy X rays was 0.0204 cm, the Phy-X/PSD value was 0.0296 cm. The HVL value of the TCR material for X-rays with an energy of 100 keV was 0.021 cm for Phy-X/PSD and 0.014 cm for GAMOS. It has been observed to provide excellent radiation protection against X-rays in the diagnostic imaging field. By providing greater flexibility than lead shielding materials, TCR can play a crucial role in decreasing radiation exposure.


  • Open Access

    Validation of a Proposed Equation for Determining the Half-Thickness Value of Gamma and X-Ray Radiation

    by Meryem Cansu Şahi̇n, Kaan Mani̇sA, Hasan Bi̇rCan

    Half-value layer (HVL) is energy dependent on the photon, much as the attenuation coefficient. Increasing the penetrating energy of a photon stream causes an increase in a substance's HVL. Before calculating the HVL value, the linear attenuation coefficient (μ) must be established. A review of the literature indicated that there is presently no Monte Carlo-based sufficient tool for direct calculation of the HVL value and direct computation suitable for material design and all changes based on sophisticated simulation methods. This study aims to calculate HVL data with GAMOS simulation in the 0.1-20 MeV energy range for some anatomical structures defined in ICRU-44 (bone cortical, brain, gray/white matter, breast tissue, eye lens, and testis). The HVL values of the anatomical structures used in the GAMOS code were compared with the results in the literature. As a result, HVL values obtained from GAMOS simulation for different materials and biological structures were compatible with the literature.


  • Assessment of natural radioactivity level of soil and water in the region of Çorlu (Turkey)

    by Kaan Manisa, Mehmet Erdogan, Ali Usluer, Hakan Cetinkaya, Ulas Isik, Latife Sahin, Veysel Zedef


  • RISK ANALYSIS AND ANNUAL EFFECTIVE DOSE DUE TO TERRESTRIAL AND COSMIC RADIATION IN THE REGION OF NIĞDE PROVINCE (TURKEY)

    by Mehmet Erdogan, Kaan Manisa, Hasan Bircan, İbrahim Çevik, Nesli Bingöldağ, Recep Biyik, Veysel Zedef

  • Open Access

    Determination of the energy transitions and half-lives of Rubidium nuclei

    by Ahmet Biçer, Kaan Manisa, Abdullah Engin Çalık, Mehmet Erdoğan, Mürsel Şen, Hasan Bircan, Haris Dapo, Ismail Boztosun

    The photonuclear reactions, first extensively studied in the 1970’s and performed using the gamma rays obtained via bremsstrahlung, are a standard nuclear physics experiment. In this study, a non-enriched Rubidium sample was irradiated with photons produced by a clinical linear electron accelerator (cLINACs) with energies up to 18 MeV with the aim of activating it through photonuclear reactions. The activated sample was measured with a high purity germanium detector (HPGe) with the aim of measuring the transition energies and half-lives. The spectroscopic analysis performed on the obtained data yielded high quality results for the transition energies with precision matching or surpassing the literature data. For the half-lives the results were consistent with the literature, most notably the half-life of 84 m Rb decay was determined as 20.28(2) m. The results for both energies and half-lives further show that the clinical linear accelerators can be successfully used as an efficient tool in experimental nuclear research endeavors.


  • RADON IN SPRING WATER IN THE REGION OF SEYDİŞEHİR OF KONYA PROVINCE, TURKEY

    by M Erdogan, K Manisa, V Zedef

    Water samples for radon-gas analyses were collected from springs in and around the town of Seydişehir. Radon concentration in the spring water has been measured using the AlphaGUARD PQ 2000PRO radon detector. Radon activity results varied from 1.85 to 99.27 Bq l−1. The radon level at the measurement points could have been controlled by local geological conditions (i.e. faults) and human activities. We also calculated annual effective doses resulting from the consumption of these water samples.