Norliza Ibrahim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Norliza Ibrahim has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Paul Frans van der Stelt
Department of Oral Radiology, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Netherlands
5 shared publications A Parsa
3 shared publicationsB Hassan
3 shared publicationsD Wismeijer
2 shared publicationsDaniel Wismeijer
Department of Oral Function and Restorative Dentistry Section of Implantology and Prosthetic Dentistry Academic Center for Dentistry Amsterdam (ACTA) Amsterdam The Netherlands
2 shared publicationsI H A Aartman
2 shared publications
Latest Publications
- 1 February 2014
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 43 (2) , 20130329
Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study
The aim of this study was to assess the influence of different object locations in different fields of view (FOVs) of two cone beam CT (CBCT) systems on trabecular bone microstructure measurements of a human mandible. A block of dry human mandible was scanned at five different locations (centre, left, right, anterior and posterior) using five different FOVs of two CBCT systems (NewTom™ 5G; QR Verona, Verona, Italy and Accuitomo 170; Morita, Kyoto, Japan). Image analysis software (CTAn software v. 1.1; SkyScan, Kontich, Belgium) was used to assess the trabecular bone microstructural parameters (thickness, Tb.Th; spacing, Tb.Sp; number, Tb.N; bone volume density, BV/TV). All measurements were taken twice by one trained observer. Tb.Th, Tb.Sp and Tb.N varied significantly across different FOVs in the NewTom 5G (p < 0.001) and the Accuitomo 170 (p < 0.001). For location, a significant difference was observed only when measuring BV/TV (p = 0.03) using the NewTom 5G. The trabecular bone microstructural measurements obtained from CBCT systems are influenced by the size of FOVs. Not all trabecular bone parameters measured using different CBCT systems are affected when varying the object location within the FOVs.
- 1 February 2014
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 43 (2) , 20130329
Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study
The aim of this study was to assess the influence of different object locations in different fields of view (FOVs) of two cone beam CT (CBCT) systems on trabecular bone microstructure measurements of a human mandible. A block of dry human mandible was scanned at five different locations (centre, left, right, anterior and posterior) using five different FOVs of two CBCT systems (NewTom™ 5G; QR Verona, Verona, Italy and Accuitomo 170; Morita, Kyoto, Japan). Image analysis software (CTAn software v. 1.1; SkyScan, Kontich, Belgium) was used to assess the trabecular bone microstructural parameters (thickness, Tb.Th; spacing, Tb.Sp; number, Tb.N; bone volume density, BV/TV). All measurements were taken twice by one trained observer. Tb.Th, Tb.Sp and Tb.N varied significantly across different FOVs in the NewTom 5G (p < 0.001) and the Accuitomo 170 (p < 0.001). For location, a significant difference was observed only when measuring BV/TV (p = 0.03) using the NewTom 5G. The trabecular bone microstructural measurements obtained from CBCT systems are influenced by the size of FOVs. Not all trabecular bone parameters measured using different CBCT systems are affected when varying the object location within the FOVs.
- Open Access
- 1 December 2013
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 42 (10) , 20130206
The effect of scan parameters on cone beam CT trabecular bone microstructural measurements of the human mandible
The objective of this study was to investigate the effect of different cone beam CT scan parameters on trabecular bone microstructure measurements. A human mandibular cadaver was scanned using a cone beam CT (3D Accuitomo 170; J.Morita, Kyota, Japan). 20 cone beam CT images were obtained using 5 different fields of view (4×4 cm, 6×6 cm, 8×8 cm, 10×10 cm and 10×5 cm), 2 types of rotation steps (180° and 360°) and 2 scanning resolutions (standard and high). Image analysis software was used to assess the trabecular bone microstructural parameters (number, thickness and spacing). All parameters were measured twice by one trained observer. Intraclass correlation coefficients showed high intraobserver repeatability (intraclass correlation coefficient, 0.95-0.97) in all parameters across all tested scan parameters. Trabecular bone microstructural measurements varied significantly, especially in smaller fields of view (p = 0.001). There was no significant difference in the trabecular parameters when using different resolutions (number, p = 0.988; thickness, p = 0.960; spacing, p = 0.831) and rotation steps (number, p = 1.000; thickness, p = 0.954; spacing, p = 0.759). The scan field of view significantly influences the trabecular bone microstructure measurements. Rotation steps (180° or 360°) and resolution (standard or high) selections are not relevant.
- 1 December 2013
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 42 (10) , 20130206
Open AccessThe effect of scan parameters on cone beam CT trabecular bone microstructural measurements of the human mandible
The objective of this study was to investigate the effect of different cone beam CT scan parameters on trabecular bone microstructure measurements. A human mandibular cadaver was scanned using a cone beam CT (3D Accuitomo 170; J.Morita, Kyota, Japan). 20 cone beam CT images were obtained using 5 different fields of view (4×4 cm, 6×6 cm, 8×8 cm, 10×10 cm and 10×5 cm), 2 types of rotation steps (180° and 360°) and 2 scanning resolutions (standard and high). Image analysis software was used to assess the trabecular bone microstructural parameters (number, thickness and spacing). All parameters were measured twice by one trained observer. Intraclass correlation coefficients showed high intraobserver repeatability (intraclass correlation coefficient, 0.95-0.97) in all parameters across all tested scan parameters. Trabecular bone microstructural measurements varied significantly, especially in smaller fields of view (p = 0.001). There was no significant difference in the trabecular parameters when using different resolutions (number, p = 0.988; thickness, p = 0.960; spacing, p = 0.831) and rotation steps (number, p = 1.000; thickness, p = 0.954; spacing, p = 0.759). The scan field of view significantly influences the trabecular bone microstructure measurements. Rotation steps (180° or 360°) and resolution (standard or high) selections are not relevant.
- 15 April 2013
- Published by Wiley in Clinical Oral Implants Research
- Vol. 25 (8) , 941-945
Accuracy of trabecular bone microstructural measurement at planned dental implant sites using cone‐beam CT datasets
Objective: Cone‐beam CT (CBCT) images are infrequently utilized for trabecular bone microstructural measurement due to the system's limited resolution. The aim of this study was to determine the accuracy of CBCT for measuring trabecular bone microstructure in comparison with micro CT (μCT).Materials and methods: Twenty‐four human mandibular cadavers were scanned using a CBCT system (80 μm) and a μCT system (35 μm). Three bone microstructural parameters trabecular number (Tb.N), thickness (Tb.Th) and separation (Tb.Sp) were assessed using CTAn imaging software.Results: Intraclass correlation coefficients (ICC) showed a high intra‐observer reliability (≥ 0.996) in all parameters for both systems. The Pearson correlation coefficients between the measurements of the two systems were for Tb.Th 0.82, for Tb.Sp 0.94 and for Tb.N 0.85 (all P's<0.001). The Bland and Altman plots showed strongest agreement in Tb.N (‐0.37 μm) followed by Tb.Th (1.6μm) and Tb.Sp (8.8μm).Conclusions: Cone‐beam CT datasets can be used to evaluate trabecular bone microstructure at dental implant sites. The accuracy for measuring Tb.N was the best followed by Tb.Th and Tb.Sp.
- 15 April 2013
- Published by Wiley in Clinical Oral Implants Research
- Vol. 25 (8) , 941-945
Accuracy of trabecular bone microstructural measurement at planned dental implant sites using cone‐beam CT datasets
Objective: Cone‐beam CT (CBCT) images are infrequently utilized for trabecular bone microstructural measurement due to the system's limited resolution. The aim of this study was to determine the accuracy of CBCT for measuring trabecular bone microstructure in comparison with micro CT (μCT).Materials and methods: Twenty‐four human mandibular cadavers were scanned using a CBCT system (80 μm) and a μCT system (35 μm). Three bone microstructural parameters trabecular number (Tb.N), thickness (Tb.Th) and separation (Tb.Sp) were assessed using CTAn imaging software.Results: Intraclass correlation coefficients (ICC) showed a high intra‐observer reliability (≥ 0.996) in all parameters for both systems. The Pearson correlation coefficients between the measurements of the two systems were for Tb.Th 0.82, for Tb.Sp 0.94 and for Tb.N 0.85 (all P's<0.001). The Bland and Altman plots showed strongest agreement in Tb.N (‐0.37 μm) followed by Tb.Th (1.6μm) and Tb.Sp (8.8μm).Conclusions: Cone‐beam CT datasets can be used to evaluate trabecular bone microstructure at dental implant sites. The accuracy for measuring Tb.N was the best followed by Tb.Th and Tb.Sp.
- Open Access
- 1 March 2013
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 42 (3) , 20120075
Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review
Several dental implant studies have reported that radiographic evaluation of bone quality can aid in reducing implant failure. Bone quality is assessed in terms of its quantity, density, trabecular characteristics and cells. Current imaging modalities vary widely in their efficiency in assessing trabecular structures, especially in a clinical setting. Most are very costly, require an extensive scanning procedure coupled with a high radiation dose and are only partially suitable for patient use. This review examines the current literature regarding diagnostic imaging assessment of trabecular microstructure prior to oral implant placement and suggests cone beam CT as a method of choice for evaluating trabecular bone microstructure.
- 1 March 2013
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 42 (3) , 20120075
Open AccessDiagnostic imaging of trabecular bone microstructure for oral implants: a literature review
Several dental implant studies have reported that radiographic evaluation of bone quality can aid in reducing implant failure. Bone quality is assessed in terms of its quantity, density, trabecular characteristics and cells. Current imaging modalities vary widely in their efficiency in assessing trabecular structures, especially in a clinical setting. Most are very costly, require an extensive scanning procedure coupled with a high radiation dose and are only partially suitable for patient use. This review examines the current literature regarding diagnostic imaging assessment of trabecular microstructure prior to oral implant placement and suggests cone beam CT as a method of choice for evaluating trabecular bone microstructure.
- 29 November 2012
- Vol. 27 (6) , 1438-42
Reliability of voxel gray values in cone beam computed tomography for preoperative implant planning assessment.
To assess the reliability of cone beam computed tomography (CBCT) voxel gray value measurements using Hounsfield units (HU) derived from multislice computed tomography (MSCT) as a clinical reference (gold standard). Ten partially edentulous human mandibular cadavers were scanned by two types of computed tomography (CT) modalities: multislice CT and cone beam CT. On MSCT scans, eight regions of interest (ROI) designating the site for preoperative implant placement were selected in each mandible. The datasets from both CT systems were matched using a three-dimensional (3D) registration algorithm. The mean voxel gray values of the region around the implant sites were compared between MSCT and CBCT. Significant differences between the mean gray values obtained by CBCT and HU by MSCT were found. In all the selected ROIs, CBCT showed higher mean values than MSCT. A strong correlation (R=0.968) between mean voxel gray values of CBCT and mean HU of MSCT was determined. Voxel gray values from CBCT deviate from actual HU units. However, a strong linear correlation exists, which may permit deriving actual HU units from CBCT using linear regression models.
- 29 November 2012
- Vol. 27 (6) , 1438-42
Reliability of voxel gray values in cone beam computed tomography for preoperative implant planning assessment.
To assess the reliability of cone beam computed tomography (CBCT) voxel gray value measurements using Hounsfield units (HU) derived from multislice computed tomography (MSCT) as a clinical reference (gold standard). Ten partially edentulous human mandibular cadavers were scanned by two types of computed tomography (CT) modalities: multislice CT and cone beam CT. On MSCT scans, eight regions of interest (ROI) designating the site for preoperative implant placement were selected in each mandible. The datasets from both CT systems were matched using a three-dimensional (3D) registration algorithm. The mean voxel gray values of the region around the implant sites were compared between MSCT and CBCT. Significant differences between the mean gray values obtained by CBCT and HU by MSCT were found. In all the selected ROIs, CBCT showed higher mean values than MSCT. A strong correlation (R=0.968) between mean voxel gray values of CBCT and mean HU of MSCT was determined. Voxel gray values from CBCT deviate from actual HU units. However, a strong linear correlation exists, which may permit deriving actual HU units from CBCT using linear regression models.