Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study
Authors:
- N IbrahimNIN Ibrahim
- A ParsaAPA Parsa
- B HassanBHB Hassan
- P van der SteltPSP van der Stelt
- I H A AartmanIAI H A Aartman
- P NambiarPNP Nambiar
- 1 February 2014
- journal article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 43 (2) , 20130329
Abstract
The aim of this study was to assess the influence of different object locations in different fields of view (FOVs) of two cone beam CT (CBCT) systems on trabecular bone microstructure measurements of a human mandible. A block of dry human mandible was scanned at five different locations (centre, left, right, anterior and posterior) using five different FOVs of two CBCT systems (NewTom™ 5G; QR Verona, Verona, Italy and Accuitomo 170; Morita, Kyoto, Japan). Image analysis software (CTAn software v. 1.1; SkyScan, Kontich, Belgium) was used to assess the trabecular bone microstructural parameters (thickness, Tb.Th; spacing, Tb.Sp; number, Tb.N; bone volume density, BV/TV). All measurements were taken twice by one trained observer. Tb.Th, Tb.Sp and Tb.N varied significantly across different FOVs in the NewTom 5G (p < 0.001) and the Accuitomo 170 (p < 0.001). For location, a significant difference was observed only when measuring BV/TV (p = 0.03) using the NewTom 5G. The trabecular bone microstructural measurements obtained from CBCT systems are influenced by the size of FOVs. Not all trabecular bone parameters measured using different CBCT systems are affected when varying the object location within the FOVs.Keywords
This publication has 29 references indexed in Scilit:
- Diagnostic imaging of trabecular bone microstructure for oral implants: a literature reviewDentomaxillofacial Radiology, 2013
- The effect of voxel size on high‐resolution peripheral computed tomography measurements of trabecular and cortical bone microstructureMedical Physics, 2012
- Characterization and correction of cupping effect artefacts in cone beam CTDentomaxillofacial Radiology, 2012
- Artefacts in CBCT: a reviewDentomaxillofacial Radiology, 2011
- Cone-beam computed tomography to detect erosions of the temporomandibular joint: Effect of field of view and voxel size on diagnostic efficacy and effective doseAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2011
- Analysis of intensity variability in multislice and cone beam computed tomographyClinical Oral Implants Research, 2011
- Influence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomographyClinical Oral Investigations, 2009
- Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging systemDentomaxillofacial Radiology, 2008
- A new method for x-ray scatter correction: first assessment on a cone-beam CT experimental setupPhysics in Medicine & Biology, 2007
- Trabecular alveolar bone microarchitecture in the human mandible using high resolution magnetic resonance imagingDentomaxillofacial Radiology, 2004