Piotr Zygmanski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Piotr Zygmanski has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Erno Sajo
University of Massachusetts Lowell
10 shared publications Y Lyatskaya
9 shared publications- Davide Brivio
Radiation Oncology, Brigham and Women's Hospital, 75 Francis Street, 75 Francis Street, Boston, Massachusetts, 02115, UNITED STATES
7 shared publications - Wolfgang Hoegele
Department of Computer Science and Mathematics, Munich University of Applied Sciences HM, Munich, Germany
6 shared publications J. Hesser
Department of Radiation Oncology University Medical Center Mannheim, University of Heidelberg Germany
4 shared publicationsK Marcus
4 shared publications
Latest Publications
- 17 October 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065042
Computed tomography employing sensing of high energy particle current
Objective. We demonstrate High Energy Current Computed Tomography (HEC-CT) employing megavoltage linac x-rays. Approach. Using deterministic radiation transport we simulate two-parameter HEC-CT projections and using inverse Fourier transform we reconstruct two distinct material parameters for water phantoms with ICRP tissue inserts and materials of different atomic number Z. The HEC-CT projections are obtained by beam scanning and rotating the object. Main Results. The first HEC-CT material parameter is alike the standard attenuation coefficient with dependence on atomic number and material density similar to the Hounsfield Units. The second material parameter has opposite trends and does not find any analogy in the standard CT framework. Significance. New CT method has been invented for medical imaging or non-destructive testing. The key feature of the technique is a two-value CT reconstruction based on particle current instead of transmitted dose.
- 17 October 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065042
Computed tomography employing sensing of high energy particle current
Objective. We demonstrate High Energy Current Computed Tomography (HEC-CT) employing megavoltage linac x-rays. Approach. Using deterministic radiation transport we simulate two-parameter HEC-CT projections and using inverse Fourier transform we reconstruct two distinct material parameters for water phantoms with ICRP tissue inserts and materials of different atomic number Z. The HEC-CT projections are obtained by beam scanning and rotating the object. Main Results. The first HEC-CT material parameter is alike the standard attenuation coefficient with dependence on atomic number and material density similar to the Hounsfield Units. The second material parameter has opposite trends and does not find any analogy in the standard CT framework. Significance. New CT method has been invented for medical imaging or non-destructive testing. The key feature of the technique is a two-value CT reconstruction based on particle current instead of transmitted dose.
- 21 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 17NT02
Remote sensing of high energy charged particle current (HEC) for megavoltage therapeutic electron beams
Objective. We demonstrate detection of high energy particle current (HEC) for MeV therapeutic electron beams. Detection of HEC comprises of remote sensing or acquiring information about HEC inside radiation transport medium from a distance outside of the medium. Approach. HEC is self-propelled motion of charged particles through a radiation transport medium. Remote sensing of HEC is embodied in an experimental setup, which includes homogeneous and heterogeneous phantoms irradiated with 4–15 MeV electron beams and two large area parallel-plane electrodes extraneous to the phantoms providing two-parameter detection. We also introduce a new type of scanning method (depth-scan) for probing object properties along the beamline axis. Main Results. Deterministic radiation transport simulations and measurements agree, considering differences in simulation vs experimental geometry and experimental uncertainties. Significance. This method may be suitable for range detection of charged particle beams, or for probing of radiation opaque objects in non-destructive testing.
- 21 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 17NT02
Remote sensing of high energy charged particle current (HEC) for megavoltage therapeutic electron beams
Objective. We demonstrate detection of high energy particle current (HEC) for MeV therapeutic electron beams. Detection of HEC comprises of remote sensing or acquiring information about HEC inside radiation transport medium from a distance outside of the medium. Approach. HEC is self-propelled motion of charged particles through a radiation transport medium. Remote sensing of HEC is embodied in an experimental setup, which includes homogeneous and heterogeneous phantoms irradiated with 4–15 MeV electron beams and two large area parallel-plane electrodes extraneous to the phantoms providing two-parameter detection. We also introduce a new type of scanning method (depth-scan) for probing object properties along the beamline axis. Main Results. Deterministic radiation transport simulations and measurements agree, considering differences in simulation vs experimental geometry and experimental uncertainties. Significance. This method may be suitable for range detection of charged particle beams, or for probing of radiation opaque objects in non-destructive testing.
- 3 May 2024
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 57 (28) , 285403
Remote sensing of high energy particle currents (HEC): towards HEC radiography
High-energy charged particle current (HEC) originating in or passing through an object creates mirror currents in a system of electrodes surrounding it. The electrodes are not in an electrically conductive contact with the object; they can be placed at a distance from its surface. We employ this effect to probe the object by measuring HEC-radiographic signal for a megavoltage x-ray scanning beam and for a broad static beam. Unlike in standard radiography, where an external bank of detectors measures the emerging radiation from the object, the principle of the proposed HEC radiography relies on remotely sensing the current distribution inside the object. Thus, HEC radiography is capable of probing objects that absorb all or most of the primary incident beam and where transmitted radiation cannot be used for image formation or reconstruction. Potential applications of this technology include non-destructive imaging of radio-opaque objects andin-vivomonitoring of charged particle ranges or dose distribution during cancer radiotherapy.
- 3 May 2024
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 57 (28) , 285403
Remote sensing of high energy particle currents (HEC): towards HEC radiography
High-energy charged particle current (HEC) originating in or passing through an object creates mirror currents in a system of electrodes surrounding it. The electrodes are not in an electrically conductive contact with the object; they can be placed at a distance from its surface. We employ this effect to probe the object by measuring HEC-radiographic signal for a megavoltage x-ray scanning beam and for a broad static beam. Unlike in standard radiography, where an external bank of detectors measures the emerging radiation from the object, the principle of the proposed HEC radiography relies on remotely sensing the current distribution inside the object. Thus, HEC radiography is capable of probing objects that absorb all or most of the primary incident beam and where transmitted radiation cannot be used for image formation or reconstruction. Potential applications of this technology include non-destructive imaging of radio-opaque objects andin-vivomonitoring of charged particle ranges or dose distribution during cancer radiotherapy.
- 13 February 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (2) , 025027
Radioactive source localization employing resistive electrode array (REA) detector
Objective. In this feasibility study, we explore an application of a Resistive Electrode Array (REA) for localization of a radioactive point source. The inverse problem posed by multichannel REA detection is studied from mathematical perspective and involves the questions of the minimal configuration of the conductive leads that can achieve this goal. The basic configuration consists of a circularly shaped REA with four opposite electrical lead–pairs at its perimeter. Approach. A robust mathematical reconstruction method for a 3D radioactive source relative to the REA is presented. The characteristic empirical Green’s function for the detector response of the REA is determined by numerically solving Laplace equations with appropriate boundary conditions. Based on this model, Monte Carlo simulations of the inverse problem with Gaussian noise are performed and the overall accuracy of the localization is investigated. Main results. The results show a 3D error distribution of localization which is uniform in the (x, y)–plane of the REA and strongly correlated in the orthogonal z–axis. The overall accuracy decreases with higher distance of the source to the detector which is intuitive due to approximate flux dependence following the inverse square law. Further, a saturation in accuracy regarding the number of electrical leads and a linear dependence of the reconstruction error on the measurement noise level are observed. Significance. A broad range of REA detector configurations and their characteristics are investigated by this study for radioactive source localization allowing diverse practical applications with detector diameters ranging from millimeters to meters.
- 13 February 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (2) , 025027
Radioactive source localization employing resistive electrode array (REA) detector
Objective. In this feasibility study, we explore an application of a Resistive Electrode Array (REA) for localization of a radioactive point source. The inverse problem posed by multichannel REA detection is studied from mathematical perspective and involves the questions of the minimal configuration of the conductive leads that can achieve this goal. The basic configuration consists of a circularly shaped REA with four opposite electrical lead–pairs at its perimeter. Approach. A robust mathematical reconstruction method for a 3D radioactive source relative to the REA is presented. The characteristic empirical Green’s function for the detector response of the REA is determined by numerically solving Laplace equations with appropriate boundary conditions. Based on this model, Monte Carlo simulations of the inverse problem with Gaussian noise are performed and the overall accuracy of the localization is investigated. Main results. The results show a 3D error distribution of localization which is uniform in the (x, y)–plane of the REA and strongly correlated in the orthogonal z–axis. The overall accuracy decreases with higher distance of the source to the detector which is intuitive due to approximate flux dependence following the inverse square law. Further, a saturation in accuracy regarding the number of electrical leads and a linear dependence of the reconstruction error on the measurement noise level are observed. Significance. A broad range of REA detector configurations and their characteristics are investigated by this study for radioactive source localization allowing diverse practical applications with detector diameters ranging from millimeters to meters.
- Open Access
- 25 April 2023
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 33 (2) , 119-122
Nanoparticle-based radiotherapy: Is dose all that matters?
- 25 April 2023
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 33 (2) , 119-122
Open AccessNanoparticle-based radiotherapy: Is dose all that matters?
- 24 June 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (13) , 135005
Resistive electrode array (REA) for radiotherapy beam monitoring and quality assurance
We have developed a new type of detector array for monitoring of radiation beams in radiotherapy. The detector has parallel-plane architecture with multiple large-area uniform thin-film electrodes. At least one of the electrodes is resistive and has multiple signal readouts spread out along its perimeter. The integral dose deposited in the detector gives rise to multiple signals that depend on the distribution of radiation with respect to resistive electrode array (REA) geometry. The purpose of the present study was to experimentally determine basic detector response to MLC collimated x-ray fields. Two detector arrays have been characterized: circular and rectangular. The current and electrostatic potential distribution within the resistive electrode are governed by the Laplace and continuity equations with boundary conditions at the border with the readouts. Measurements for pencil beams showed that signal strength depends primarily on the distances between the location of the pencil beam and the readouts. Measurements for larger irregular MLC showed that signals as a function of time are quasi-linear with respect to MLC position and are proportional to the MLC area. Derivation of clinically relevant radiation beam parameters from REA signals, such as MLC position, MLC gap size and monitor unit per MLC segment relies on the detector response model with empirical model parameters. An approximate analytical detector response model was proposed and used to fit experiment data.
- 24 June 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (13) , 135005
Resistive electrode array (REA) for radiotherapy beam monitoring and quality assurance
We have developed a new type of detector array for monitoring of radiation beams in radiotherapy. The detector has parallel-plane architecture with multiple large-area uniform thin-film electrodes. At least one of the electrodes is resistive and has multiple signal readouts spread out along its perimeter. The integral dose deposited in the detector gives rise to multiple signals that depend on the distribution of radiation with respect to resistive electrode array (REA) geometry. The purpose of the present study was to experimentally determine basic detector response to MLC collimated x-ray fields. Two detector arrays have been characterized: circular and rectangular. The current and electrostatic potential distribution within the resistive electrode are governed by the Laplace and continuity equations with boundary conditions at the border with the readouts. Measurements for pencil beams showed that signal strength depends primarily on the distances between the location of the pencil beam and the readouts. Measurements for larger irregular MLC showed that signals as a function of time are quasi-linear with respect to MLC position and are proportional to the MLC area. Derivation of clinically relevant radiation beam parameters from REA signals, such as MLC position, MLC gap size and monitor unit per MLC segment relies on the detector response model with empirical model parameters. An approximate analytical detector response model was proposed and used to fit experiment data.
- 30 January 2017
- Published by Wiley in Medical Physics
- Vol. 44 (3) , 1204-1205
Comment on: Polarity effects and apparent ion recombination in microionization chambers Med. Phys. 43(5), 2141-2152 (2016)
- 30 January 2017
- Published by Wiley in Medical Physics
- Vol. 44 (3) , 1204-1205
Comment on: Polarity effects and apparent ion recombination in microionization chambers Med. Phys. 43(5), 2141-2152 (2016)
- 1 March 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1059) , 20150200
Nanoscale radiation transport and clinical beam modeling for gold nanoparticle dose enhanced radiotherapy (GNPT) using X-rays
We review radiation transport and clinical beam modelling for gold nanoparticle dose-enhanced radiotherapy using X-rays. We focus on the nanoscale radiation transport and its relation to macroscopi...
- 1 March 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1059) , 20150200
Nanoscale radiation transport and clinical beam modeling for gold nanoparticle dose enhanced radiotherapy (GNPT) using X-rays
We review radiation transport and clinical beam modelling for gold nanoparticle dose-enhanced radiotherapy using X-rays. We focus on the nanoscale radiation transport and its relation to macroscopi...
- 15 December 2015
- Published by Wiley in Medical Physics
- Vol. 43 (1) , 16-22
Prototypes of self-powered radiation detectors employing intrinsic high-energy current
Purpose: The authors experimentally investigate the effect of direct energy conversion of x-rays via selfpowered Auger- and photocurrent, potentially suitable to practical radiationdetection and dosimetry in medical applications. Experimental results are compared to computational predictions. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. This paper focuses on the experiments while a companion paper introduces the fundamental concepts of high-energy current (HEC) detectors. Methods: The energy of ionizing radiation is directly converted to detector signal via electric current induced by high-energy secondary electrons generated in the detector material by the incident primary radiation. The HEC electrons also ionize the dielectric and the resultant charge carriers are selfcollected due to the contact potential of the disparate electrodes. Thus, an electric current is induced in the conductors in two different ways without the need for externally applied bias voltage or amplification. Thus, generated signal in turn is digitized by a data acquisition system. To determine the fundamental properties of the HEC detector and to demonstrate its feasibility for medical applications, the authors used a planar geometry composed of multilayer microstructures. Various detectors with up to seven conducting layers with different combinations of materials (250 μm Al, 35 μm Cu, 100 μm Pb) and air gaps (100 μm) were exposed to nearly plane-parallel 60–120 kVp x-ray beams. For the experimental design and verification, the authors performed coupled electron–photon radiation transport computations. The detector signal was measured using a commercial data acquisition system with 24 bits dynamic range, 0.4 fC sensitivity, and 0.9 ms sampling time. Results: Measured signals for the prototype detector varied depending on the number of layers, material type, and incident photon energy, and it was in the range of 30–150 nA/cm2 for unit air kerma (1 Gy), which is viable for practical applications. The experiments had an excellent agreement with the computations. Within the examined range of 60–120 kVp, the energy dependence of the HEC (normalized to the x-ray tube output) was relatively small. Conclusions: Based on the experimental results for 100 ms sampling time, it would be possible to measure the time dependence of x-ray beams for x-ray tube current of 0.1 mA or higher. Significant advantages of the HEC device are that generation of its signal does not require external power supply, it can be made in any size and shape, including flexible curvilinear forms, and it is inexpensive. It remains to be determined, which of the potential applications in medical dosimetry (both in vivo and external), or radiation protection would benefit from such selfpowered detectors.
- 15 December 2015
- Published by Wiley in Medical Physics
- Vol. 43 (1) , 16-22
Prototypes of self-powered radiation detectors employing intrinsic high-energy current
Purpose: The authors experimentally investigate the effect of direct energy conversion of x-rays via selfpowered Auger- and photocurrent, potentially suitable to practical radiationdetection and dosimetry in medical applications. Experimental results are compared to computational predictions. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. This paper focuses on the experiments while a companion paper introduces the fundamental concepts of high-energy current (HEC) detectors. Methods: The energy of ionizing radiation is directly converted to detector signal via electric current induced by high-energy secondary electrons generated in the detector material by the incident primary radiation. The HEC electrons also ionize the dielectric and the resultant charge carriers are selfcollected due to the contact potential of the disparate electrodes. Thus, an electric current is induced in the conductors in two different ways without the need for externally applied bias voltage or amplification. Thus, generated signal in turn is digitized by a data acquisition system. To determine the fundamental properties of the HEC detector and to demonstrate its feasibility for medical applications, the authors used a planar geometry composed of multilayer microstructures. Various detectors with up to seven conducting layers with different combinations of materials (250 μm Al, 35 μm Cu, 100 μm Pb) and air gaps (100 μm) were exposed to nearly plane-parallel 60–120 kVp x-ray beams. For the experimental design and verification, the authors performed coupled electron–photon radiation transport computations. The detector signal was measured using a commercial data acquisition system with 24 bits dynamic range, 0.4 fC sensitivity, and 0.9 ms sampling time. Results: Measured signals for the prototype detector varied depending on the number of layers, material type, and incident photon energy, and it was in the range of 30–150 nA/cm2 for unit air kerma (1 Gy), which is viable for practical applications. The experiments had an excellent agreement with the computations. Within the examined range of 60–120 kVp, the energy dependence of the HEC (normalized to the x-ray tube output) was relatively small. Conclusions: Based on the experimental results for 100 ms sampling time, it would be possible to measure the time dependence of x-ray beams for x-ray tube current of 0.1 mA or higher. Significant advantages of the HEC device are that generation of its signal does not require external power supply, it can be made in any size and shape, including flexible curvilinear forms, and it is inexpensive. It remains to be determined, which of the potential applications in medical dosimetry (both in vivo and external), or radiation protection would benefit from such selfpowered detectors.
- 15 December 2015
- Published by Wiley in Medical Physics
- Vol. 43 (1) , 4-15
A self-powered thin-film radiation detector using intrinsic high-energy current
Purpose: The authors introduce a radiation detection method that relies on high-energy current (HEC) formed by secondary charged particles in the detector material, which induces conduction current in an external readout circuit. Direct energy conversion of the incident radiation powers the signal formation without the need for external bias voltage or amplification. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. The optimal design of HEC detectors consists of microscopic or nanoscopic structures. Methods: Theoretical and computational developments are presented to illustrate the salient properties of the HEC detector and to demonstrate its feasibility. In this work, the authors examine single-sandwiched and periodic layers of Cu and Al, and Au and Al, ranging in thickness from 100 nm to 300 μm and separated by similarly sized dielectric gaps, exposed to 120 kVp x-ray beam (half-value thickness of 4.1 mm of Al). The energy deposition characteristics and the high-energy current were determined using radiation transport computations. Results: The authors found that in a dual-layer configuration, the signal is in the measurable range. For a defined total detector thickness in a multilayer structure, the signal sharply increases with decreasing thickness of the high-Z conductive layers. This paper focuses on the computational results while a companion paper reports the experimental findings. Conclusions: Significant advantages of the device are that it does not require external power supply and amplification to create a measurable signal; it can be made in any size and geometry, including very thin (sub-millimeter to submicron) flexible curvilinear forms, and it is inexpensive. Potential applications include medical dosimetry (both in vivo and external), radiation protection, and other settings where one or more of the above qualities are desired.
- 15 December 2015
- Published by Wiley in Medical Physics
- Vol. 43 (1) , 4-15
A self-powered thin-film radiation detector using intrinsic high-energy current
Purpose: The authors introduce a radiation detection method that relies on high-energy current (HEC) formed by secondary charged particles in the detector material, which induces conduction current in an external readout circuit. Direct energy conversion of the incident radiation powers the signal formation without the need for external bias voltage or amplification. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. The optimal design of HEC detectors consists of microscopic or nanoscopic structures. Methods: Theoretical and computational developments are presented to illustrate the salient properties of the HEC detector and to demonstrate its feasibility. In this work, the authors examine single-sandwiched and periodic layers of Cu and Al, and Au and Al, ranging in thickness from 100 nm to 300 μm and separated by similarly sized dielectric gaps, exposed to 120 kVp x-ray beam (half-value thickness of 4.1 mm of Al). The energy deposition characteristics and the high-energy current were determined using radiation transport computations. Results: The authors found that in a dual-layer configuration, the signal is in the measurable range. For a defined total detector thickness in a multilayer structure, the signal sharply increases with decreasing thickness of the high-Z conductive layers. This paper focuses on the computational results while a companion paper reports the experimental findings. Conclusions: Significant advantages of the device are that it does not require external power supply and amplification to create a measurable signal; it can be made in any size and geometry, including very thin (sub-millimeter to submicron) flexible curvilinear forms, and it is inexpensive. Potential applications include medical dosimetry (both in vivo and external), radiation protection, and other settings where one or more of the above qualities are desired.