P. K. Vijayan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
P. K. Vijayan has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- D. Saha
Bhabha Atomic Research Centre, Mumbai, India
6 shared publications - R. K. Sinha
Bhabha Atomic Research Centre, Mumbai, India
5 shared publications - Darwan S. Pilkhwal
Bhabha Atomic Research Centre, Mumbai, India
4 shared publications - Manish Sharma
Bhabha Atomic Research Centre, Mumbai, India
3 shared publications - A. K. Nayak
Reactor Design and Development Group, Bhabha Atomic Research Centre , Trombay, Mumbai , 400 085 , INDIA
2 shared publications - Avinash J. Gaikwad
Reactor Safety Division, BARC, Trombay, Mumbai, India
2 shared publications
Latest Publications
- 8 March 2018
- Published by Walter de Gruyter GmbH in Kerntechnik
- Vol. 83 (1) , 28-35
Natural circulation in a rectangular loop with vertical heater below vertical cooler
Many upcoming new generation reactors employ natural circulation for heat transfer in normal mode of operation. Natural circulation systems are simpler and safer than their forced circulation counterparts. However, these systems are prone to flow instability which are undesirable due to several reasons. In the present work, a rectangular glass loop, wherein cooler is just above the heater, has been considered for experimental and numerical investigation at atmospheric pressure. Heat addition from room conditions has been studied to understand the natural circulation loop dynamics, checking the possibility of occurrence of instability with the new orientation of the heater and the cooler. Experiments were performed at different power levels and coolant flow rates. CFD analyses were performed for all the cases investigated experimentally using the commercial CFD code ANSYS FLUENT 14.0. No instability was observed during the experiments and none during the simulations done for the duration of the experiments.
- 8 March 2018
- Published by Walter de Gruyter GmbH in Kerntechnik
- Vol. 83 (1) , 28-35
Natural circulation in a rectangular loop with vertical heater below vertical cooler
Many upcoming new generation reactors employ natural circulation for heat transfer in normal mode of operation. Natural circulation systems are simpler and safer than their forced circulation counterparts. However, these systems are prone to flow instability which are undesirable due to several reasons. In the present work, a rectangular glass loop, wherein cooler is just above the heater, has been considered for experimental and numerical investigation at atmospheric pressure. Heat addition from room conditions has been studied to understand the natural circulation loop dynamics, checking the possibility of occurrence of instability with the new orientation of the heater and the cooler. Experiments were performed at different power levels and coolant flow rates. CFD analyses were performed for all the cases investigated experimentally using the commercial CFD code ANSYS FLUENT 14.0. No instability was observed during the experiments and none during the simulations done for the duration of the experiments.
- 28 August 2015
- Published by Springer Nature in Pramana
- Vol. 85 (3) , 539-554
Conceptual design of Indian molten salt breeder reactor
- 28 August 2015
- Published by Springer Nature in Pramana
- Vol. 85 (3) , 539-554
Conceptual design of Indian molten salt breeder reactor
- 11 August 2015
- Published by Wiley in Journal of Heat Transfer
- Vol. 137 (12) , 124501
Prediction of Vapor Film Thickness Below a Leidenfrost Drop
In this work, the vapor film thickness below a stagnant Leidenfrost drop at saturation temperature is predicted by performing a balance of the dominant forces acting on the drop. Inclusion of a new momentum force term is proposed. Two assumptions are considered for the radial velocity of vapor at drop–vapor interface. One of them is zero radial velocity at interface and the other is zero shear at interface. The actual scenario is expected to lie between these extremes. This is also supported by the comparison against experimental data on vapor film thickness. The effect of convection in the vapor layer is also modeled and it is shown that the use of ad hoc heat transfer coefficients in the vapor layer to explain difference between experiments and prediction is incorrect. Finally, it is highlighted that accurate prediction of the vapor layer characteristics also requires proper quantification of the shape of the drop–vapor interface.
- 11 August 2015
- Published by Wiley in Journal of Heat Transfer
- Vol. 137 (12) , 124501
Prediction of Vapor Film Thickness Below a Leidenfrost Drop
In this work, the vapor film thickness below a stagnant Leidenfrost drop at saturation temperature is predicted by performing a balance of the dominant forces acting on the drop. Inclusion of a new momentum force term is proposed. Two assumptions are considered for the radial velocity of vapor at drop–vapor interface. One of them is zero radial velocity at interface and the other is zero shear at interface. The actual scenario is expected to lie between these extremes. This is also supported by the comparison against experimental data on vapor film thickness. The effect of convection in the vapor layer is also modeled and it is shown that the use of ad hoc heat transfer coefficients in the vapor layer to explain difference between experiments and prediction is incorrect. Finally, it is highlighted that accurate prediction of the vapor layer characteristics also requires proper quantification of the shape of the drop–vapor interface.
- 27 December 2013
- Published by Springer Nature in Sādhanā
- Vol. 38 (6) , 1173-1217
Entrainment phenomenon in gas–liquid two-phase flow: A review
- 27 December 2013
- Published by Springer Nature in Sādhanā
- Vol. 38 (6) , 1173-1217
Entrainment phenomenon in gas–liquid two-phase flow: A review
- Open Access
- 26 October 2013
- Published by Springer Nature in Sādhanā
- Vol. 38 (5) , 925-943
Safety features in nuclear power plants to eliminate the need of emergency planning in public domain
- 26 October 2013
- Published by Springer Nature in Sādhanā
- Vol. 38 (5) , 925-943
Open AccessSafety features in nuclear power plants to eliminate the need of emergency planning in public domain
- 28 February 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (2) , 479-489
Selection of Steam Drum Level Control Method for Multiple Drum Interacting Loops Pressure Tube-Type BWR
Three element Steam Drum (SD) Level Controller has been conventionally used for most of the boilers, Nuclear power plant steam generator & Boiling Water Reactor (BWRs). Based on the process dynamic studies it was found that this scheme does not work properly for an interacting, interconnected multiple loop boiling water system i.e., Advanced Heavy Water Reactor (AHWR). It is a pressure tube type light water cooled heavy water moderated Boiling Water Reactor (BWR). It has 4-inter-connected parallel loops with 113 × 4 = 452 boiling channels in the Main Heat Transport (MHT) system. These multiple (four) interconnected loops influences the Steam Drum (SD) level control adversely. Such a behavior has not been reported in the open literature. The open loop response is stable, non-oscillatory and non-diverging for a step change in the feed flow rates. Also it is not possible to maintain a steady level in all the SDs even without any external disturbance/perturbation with 4 conventional 3-element individual SD level controllers. To overcome these interactions it is proposed to interconnect all the four steam drums in the liquid & vapor regions respectively. This makes the 4 SDs behave like a single entity. The influence of the interconnect configuration & the level controller are studied in detail to find a robust solution. The response obtained for unsymmetrical core power, symmetrical power maneuvering and reactor trip transients shows that the SD levels do not diverge and quickly settle very near to the set points assigned with SD interconnect schemes.
- 28 February 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (2) , 479-489
Selection of Steam Drum Level Control Method for Multiple Drum Interacting Loops Pressure Tube-Type BWR
Three element Steam Drum (SD) Level Controller has been conventionally used for most of the boilers, Nuclear power plant steam generator & Boiling Water Reactor (BWRs). Based on the process dynamic studies it was found that this scheme does not work properly for an interacting, interconnected multiple loop boiling water system i.e., Advanced Heavy Water Reactor (AHWR). It is a pressure tube type light water cooled heavy water moderated Boiling Water Reactor (BWR). It has 4-inter-connected parallel loops with 113 × 4 = 452 boiling channels in the Main Heat Transport (MHT) system. These multiple (four) interconnected loops influences the Steam Drum (SD) level control adversely. Such a behavior has not been reported in the open literature. The open loop response is stable, non-oscillatory and non-diverging for a step change in the feed flow rates. Also it is not possible to maintain a steady level in all the SDs even without any external disturbance/perturbation with 4 conventional 3-element individual SD level controllers. To overcome these interactions it is proposed to interconnect all the four steam drums in the liquid & vapor regions respectively. This makes the 4 SDs behave like a single entity. The influence of the interconnect configuration & the level controller are studied in detail to find a robust solution. The response obtained for unsymmetrical core power, symmetrical power maneuvering and reactor trip transients shows that the SD levels do not diverge and quickly settle very near to the set points assigned with SD interconnect schemes.
- Open Access
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Nuclear Engineering (ICONE)
- Vol. 2011.19, _ICONE1943
ICONE-43232 STEADY STATE PERFORMANCE OF SUBCRITICAL AND SUPERCRITICAL PRESSURE NATURAL CIRCULATION IN THE SAME TEST FACILITY
For supercritical pressure natural circulation loops, explicit correlation for steady state flow are not available. While using the subcritical natural circulation flow correlation for supercritical pressure data, it has been observed that subcritical flow correlation is not able to predict the steady state flow accurately near supercritical pressure condition. A generalized correlation has been proposed to estimate the steady state flow in supercritical pressure natural circulation loop based on a relationship between dimensionless density and dimensionless enthalpy reported in literature. This generalized correlation has been tested with the steady state supercritical pressure CO_2 data and found to be in good agreement. Subsequently supercritical pressure data for different working fluids reported in literature has also been compared with the proposed correlation. It is observed that the same generalized correlation is applicable for other fluids also. The present paper deals with the details of the test facility, the derivation of the generalized correlation and comparison with experimental data.
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Nuclear Engineering (ICONE)
- Vol. 2011.19, _ICONE1943
Open AccessICONE-43232 STEADY STATE PERFORMANCE OF SUBCRITICAL AND SUPERCRITICAL PRESSURE NATURAL CIRCULATION IN THE SAME TEST FACILITY
For supercritical pressure natural circulation loops, explicit correlation for steady state flow are not available. While using the subcritical natural circulation flow correlation for supercritical pressure data, it has been observed that subcritical flow correlation is not able to predict the steady state flow accurately near supercritical pressure condition. A generalized correlation has been proposed to estimate the steady state flow in supercritical pressure natural circulation loop based on a relationship between dimensionless density and dimensionless enthalpy reported in literature. This generalized correlation has been tested with the steady state supercritical pressure CO_2 data and found to be in good agreement. Subsequently supercritical pressure data for different working fluids reported in literature has also been compared with the proposed correlation. It is observed that the same generalized correlation is applicable for other fluids also. The present paper deals with the details of the test facility, the derivation of the generalized correlation and comparison with experimental data.
- 30 June 2010
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 132 (10) , 102904
Linear and Nonlinear Stability Analysis of a Supercritical Natural Circulation Loop
Supercritical water (SCW) has excellent heat transfer characteristics as a coolant for nuclear reactors. Besides it results in high thermal efficiency of the plant. However, the flow can experience instabilities in supercritical water cooled reactors, as the density change is very large for the supercritical fluids. A computer code SUCLIN has been developed employing supercritical water properties to carry out the steady-state and linear stability analysis of a SCW natural circulation loop (SCWNCL). The conservation equations of mass, momentum, and energy have been linearized by imposing small perturbation in flow rate, enthalpy, pressure, and specific volume. The equations have been solved analytically to generate the characteristic equation. The roots of the equation determine the stability of the system. The code has been benchmarked against published results. Then the code has been extensively used for studying the effect of diameter, heater inlet temperature, and pressure on steady-state and stability behavior of a SCWNCL. A separate computer code, NOLSTA, has been developed, which investigates stability characteristics of supercritical natural circulation loop using nonlinear analysis. The conservation equations of mass, momentum, and energy in transient form were solved numerically using finite volume method. The stable, unstable, and neutrally stable points were identified by examining the amplitude of flow and temperature oscillations with time for a given set of operating conditions. The stability behavior of loop, predicted using nonlinear analysis has been compared with that obtained from linear analysis. The results show that the stability maps obtained by the two methods agree qualitatively. The present paper describes the linear and nonlinear stability analysis models and the results obtained in detail.
- 30 June 2010
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 132 (10) , 102904
Linear and Nonlinear Stability Analysis of a Supercritical Natural Circulation Loop
Supercritical water (SCW) has excellent heat transfer characteristics as a coolant for nuclear reactors. Besides it results in high thermal efficiency of the plant. However, the flow can experience instabilities in supercritical water cooled reactors, as the density change is very large for the supercritical fluids. A computer code SUCLIN has been developed employing supercritical water properties to carry out the steady-state and linear stability analysis of a SCW natural circulation loop (SCWNCL). The conservation equations of mass, momentum, and energy have been linearized by imposing small perturbation in flow rate, enthalpy, pressure, and specific volume. The equations have been solved analytically to generate the characteristic equation. The roots of the equation determine the stability of the system. The code has been benchmarked against published results. Then the code has been extensively used for studying the effect of diameter, heater inlet temperature, and pressure on steady-state and stability behavior of a SCWNCL. A separate computer code, NOLSTA, has been developed, which investigates stability characteristics of supercritical natural circulation loop using nonlinear analysis. The conservation equations of mass, momentum, and energy in transient form were solved numerically using finite volume method. The stable, unstable, and neutrally stable points were identified by examining the amplitude of flow and temperature oscillations with time for a given set of operating conditions. The stability behavior of loop, predicted using nonlinear analysis has been compared with that obtained from linear analysis. The results show that the stability maps obtained by the two methods agree qualitatively. The present paper describes the linear and nonlinear stability analysis models and the results obtained in detail.
- 8 December 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 56 (6) , 3712-3725
Effect of Loop Configuration on Steam Drum Level Control for a Multiple Drum Interconnected Loops Pressure Tube Type Boiling Water Reactor
For AHWR (Advanced Heavy Water Reactor), a pressure tube type Boiling Water Reactor (BWR) with parallel inter-connected loops, the Steam Drum (SD) level control is closely related to Main Heat Transport (MHT) coolant inventory and sustained heat removal through natural circulation, hence overall safety of the power plant. The MHT configuration with multiple (four) interconnected loops influences the SD level control in a manner which has not been previously addressed. The MHT configuration has been chosen based on comprehensive overall design requirements and certain Postulated Initiated Event (PIEs) for Loss of Coolant Accident (LOCA), which postulates a double ended break in the four partitioned Emergency Core Cooling System (ECCS) header. A conventional individual three-element SD level controller can not account for the highly coupled and interacting behaviors, of the four SD levels. An innovative three-element SD level control scheme is proposed to overcome this situation. The response obtained for a variety of unsymmetrical disturbances shows that the SD levels do not diverge and quickly settle to the various new set points assigned. The proposed scheme also leads to enhanced safety margins for most of the PIEs considered with a little influence on the 100% full power steady-state design conditions.
- 8 December 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 56 (6) , 3712-3725
Effect of Loop Configuration on Steam Drum Level Control for a Multiple Drum Interconnected Loops Pressure Tube Type Boiling Water Reactor
For AHWR (Advanced Heavy Water Reactor), a pressure tube type Boiling Water Reactor (BWR) with parallel inter-connected loops, the Steam Drum (SD) level control is closely related to Main Heat Transport (MHT) coolant inventory and sustained heat removal through natural circulation, hence overall safety of the power plant. The MHT configuration with multiple (four) interconnected loops influences the SD level control in a manner which has not been previously addressed. The MHT configuration has been chosen based on comprehensive overall design requirements and certain Postulated Initiated Event (PIEs) for Loss of Coolant Accident (LOCA), which postulates a double ended break in the four partitioned Emergency Core Cooling System (ECCS) header. A conventional individual three-element SD level controller can not account for the highly coupled and interacting behaviors, of the four SD levels. An innovative three-element SD level control scheme is proposed to overcome this situation. The response obtained for a variety of unsymmetrical disturbances shows that the SD levels do not diverge and quickly settle to the various new set points assigned. The proposed scheme also leads to enhanced safety margins for most of the PIEs considered with a little influence on the 100% full power steady-state design conditions.