AGAvinash J. Gaikwad

Avinash J. Gaikwad

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Avinash J. Gaikwad has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Selection of Steam Drum Level Control Method for Multiple Drum Interacting Loops Pressure Tube-Type BWR

    by Avinash J. Gaikwad, P. K. Vijayan, S. Bhartiya, R. Kumar, H. G. Lele, K. K. Vaze

    Three element Steam Drum (SD) Level Controller has been conventionally used for most of the boilers, Nuclear power plant steam generator & Boiling Water Reactor (BWRs). Based on the process dynamic studies it was found that this scheme does not work properly for an interacting, interconnected multiple loop boiling water system i.e., Advanced Heavy Water Reactor (AHWR). It is a pressure tube type light water cooled heavy water moderated Boiling Water Reactor (BWR). It has 4-inter-connected parallel loops with 113 × 4 = 452 boiling channels in the Main Heat Transport (MHT) system. These multiple (four) interconnected loops influences the Steam Drum (SD) level control adversely. Such a behavior has not been reported in the open literature. The open loop response is stable, non-oscillatory and non-diverging for a step change in the feed flow rates. Also it is not possible to maintain a steady level in all the SDs even without any external disturbance/perturbation with 4 conventional 3-element individual SD level controllers. To overcome these interactions it is proposed to interconnect all the four steam drums in the liquid & vapor regions respectively. This makes the 4 SDs behave like a single entity. The influence of the interconnect configuration & the level controller are studied in detail to find a robust solution. The response obtained for unsymmetrical core power, symmetrical power maneuvering and reactor trip transients shows that the SD levels do not diverge and quickly settle very near to the set points assigned with SD interconnect schemes.


  • Effect of Loop Configuration on Steam Drum Level Control for a Multiple Drum Interconnected Loops Pressure Tube Type Boiling Water Reactor

    by Avinash J. Gaikwad, P. K. Vijayan, Kannan Iyer, Sharad Bhartiya, Rajesh Kumar, H. G. Lele, A. K. Ghosh, H. S. Kushwaha, R. K. Sinha

    For AHWR (Advanced Heavy Water Reactor), a pressure tube type Boiling Water Reactor (BWR) with parallel inter-connected loops, the Steam Drum (SD) level control is closely related to Main Heat Transport (MHT) coolant inventory and sustained heat removal through natural circulation, hence overall safety of the power plant. The MHT configuration with multiple (four) interconnected loops influences the SD level control in a manner which has not been previously addressed. The MHT configuration has been chosen based on comprehensive overall design requirements and certain Postulated Initiated Event (PIEs) for Loss of Coolant Accident (LOCA), which postulates a double ended break in the four partitioned Emergency Core Cooling System (ECCS) header. A conventional individual three-element SD level controller can not account for the highly coupled and interacting behaviors, of the four SD levels. An innovative three-element SD level control scheme is proposed to overcome this situation. The response obtained for a variety of unsymmetrical disturbances shows that the SD levels do not diverge and quickly settle to the various new set points assigned. The proposed scheme also leads to enhanced safety margins for most of the PIEs considered with a little influence on the 100% full power steady-state design conditions.