JRJean-Francois Rit

Jean-Francois Rit

*This is an algorithmically generated author record based on publicly available information.

Jean-Francois Rit has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Prédire correctement l’effet des chocs thermiques sur l’assemblage corps-couvercle d’un robinet

    by Jean-François Rit, Sébastien Meunier, Jerôme Ferrari, David Hersant, Jean-Philippe Mathieu

    Préalablement à leur acquisition, les robinets installés dans les centrales nucléaires font l’objet d’une démonstration de leur aptitude à endurer des chocs thermiques d’une amplitude de 255 C, sollicitation majorante de conditions normales d’exploitation. Afin de mieux cerner la validité de démonstrations fondées sur des simulations numériques, nous confrontons l’essai en vraie grandeur d’un robinet à soupape de diamètre nominal 150 mm avec sa simulation numérique. Cet article est focalisé sur le comportement de l’assemblage boulonné du corps et du couvercle, assurant la fonction d’étanchéité, dite externe du robinet. La campagne d’essai, menée sur la boucle CYTHERE d’EDF, comprend plusieurs chocs alternés, froid puis chaud. Le robinet est équipé de 37 thermocouples distribués sur sa hauteur et dans l’épaisseur des pièces. Les douze goujons du couvercle sont équipés de jauges de déformation destinées à mesurer l’évolution de leur tension. L’essai est modélisé par des simulations multiphysiques du robinet complet en 3D, enchaînant les calculs d’écoulement, des champs de température, puis des champs de déplacement et de contraintes dans le robinet. La confrontation des résultats de calcul avec les mesures montre l’importance de la représentation des échanges thermiques résultant de l’écoulement dans les interstices laissés par les jeux fonctionnels entre les pièces internes situées sous le couvercle. Leur prise en compte est déterminante pour calculer les variations de serrage de l’assemblage lors des chocs thermiques. Prior to their acquisition, valves installed in nuclear power plants must be proof of their ability to endure thermal shocks with an amplitude of 255 C, an upper bound of normal operating conditions. In order to better understand the validity of proofs based on numerical simulations, we confront the full scale test of a valve of nominal diameter 150 mm, with its numerical simulation. This paper is focused on the behavior of the bolted assembly of the body and the bonnet, ensuring the external sealing function of the valve. The test campaign, performed on EDF’s CYTHERE loop, includes several shocks, alternatively cold and hot. The valve is equipped with 37 thermocouples distributed along its height and in the thickness of the parts. The twelve studs of the bonnet are equipped with strain gauges designed to measure the evolution of their tension. The test is modelled by multiphysics simulations of the complete valve in 3D, chaining the calculations of the flow, the temperature fields and the displacement, and stress fields in the valve. The confrontation of the calculation results with the measurements shows the importance of the thermal exchanges resulting from the flow in the interstices left by the functional clearances between the internal parts located under the lid. Their consideration is decisive in calculating the clamping variations of the assembly during thermal shocks.


  • Prediction and Measurement of Sealing Properties of Joints Between Wavy Metal Surfaces

    by Julien Bourniquel, Didier Lasseux, Jean-Francois Rit

    The transmissivity of metal-metal sealing joints is investigated experimentally and compared to predictions obtained by modeling. The focus is laid upon a wavy surface contacting a flat rigid part, representative of a seat-to-plug contact in an internal sealing valve encountered in nuclear power plants for instance. Experimental transmissivities are obtained from water leak-rate and pressure drop measurements carried out on a model ring-shape sample seat holding a controlled wavy defect and pressed against a rigid flat plug with a controlled normal load. The sample seat surface is manufactured by face turning a tubular part under radial stress and waviness is obtained after elastic relaxation. Modeling is performed on a three-dimensional finite element model of the assembly, composed of the plug, the sample seat, and its holder. The upper sample seat surface, in which topography is recorded by confocal microscopy, is reconstructed using a modal decomposition on the basis of vibrational eigenmodes. Its lower surface, in contact with the holder, is considered as perfectly flat or with its own defects. The contact aperture field between the seat and the plug is computed for a given normal load and is used to solve the incompressible Reynolds equation with a boundary element method, yielding the transmissivity. Predicted transmissivities reveal to be in good agreement with experimental data at low clamping loads and are overestimated for larger ones. Defects on the lower surface of the seat are shown to have a significant impact on the seat-to plug contact transmissivity.


  • Instability of Pressure Relief Valves in Water Pipes

    by P. Moussou, R. J. Gibert, G. Brasseur, Ch. Teygeman, J. Ferrari, J. F. Rit

    Pressure relief valves in water pipes are known to sometimes chatter when the inlet pressure slightly exceeds the set pressure. While these devices are responsible for numerous fatigue issues in process industries, there is a relatively low number of technical publications covering their performance, especially in heavy fluid applications. The present study is intended as a contribution to the understanding of pressure relief valve dynamics, taking into account fluid-structure interactions. A series of tests were performed with a water relief valve in a test rig. Adjusting the set pressure of the valve to about 30 bars, an upstream pressure varying from 20 bars to 35 bars was imposed, so that the valve opened and the water flow varied from a few m3/h to about 80 m3/h. During the tests, the pipe was equipped upstream and downstream of the valve with static pressure sensors and a flowmeter, the disk lift was measured with a laser displacement sensor, and the spring force was recorded simultaneously. Several fluctuating pressure sensors were also installed in the inlet pipe. Static instability is investigated by comparing the spring force to the hydraulic force. Dynamic instability is observed and it is shown that the resonant behavior of the disk generates an apparent negative pressure drop coefficient at some frequencies. This negative pressure drop coefficient can trigger a dynamic instability in a manner similar to the negative damping effect in leakage-flow vibrations.