SRSilvio H. Rizzi

Silvio H. Rizzi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Silvio H. Rizzi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Algorithms for Haptic Interaction With Isosurfaces Extracted From Volumetric Datasets

    by Silvio H. Rizzi, Cristian J. Luciano, P. Pat Banerjee

    Combinations of graphics and haptics libraries are used in medical simulations for simultaneous visualization and tactile interaction with complex 3D anatomy models. The minimum frame rate of 1 kHz for haptics rendering makes it a nontrivial problem when dealing with complex and highly detailed polygonal models. Multiple haptics algorithms based on polygonal mesh rendering, volume haptics, and intermediate representation are evaluated in terms of their servoloop rendering time, client thread rendering time, and quality of force feedback. Algorithms include OpenHaptics’ Feedback Buffer and Depth Buffer, GodObject and Ruspini renderers in h3d, chai3d implementation in h3d, ScalarSurfaceFriction mode in Volume Haptics ToolKit (vhtk), and the authors’ intermediate representation algorithm based on volumetric data. The latter, in combination with surface graphics visualization, is found to deliver the best rendering time, to detect all collisions and to provide correct haptic feedback where other algorithms fail.


  • Top Cited Papers
    Open Access

    Virtual reality training in neurosurgery: Review of current status and future applications

    by Ali Alaraj, MichaelG Lemole, JoshuaH Finkle, Rachel Yudkowsky, Adam Wallace, Cristian Luciano, Ppat Banerjee, SilvioH Rizzi, FadyT Charbel

    Over years, surgical training is changing and years of tradition are being challenged by legal and ethical concerns for patient safety, work hour restrictions, and the cost of operating room time. Surgical simulation and skill training offer an opportunity to teach and practice advanced techniques before attempting them on patients. Simulation training can be as straightforward as using real instruments and video equipment to manipulate simulated "tissue" in a box trainer. More advanced virtual reality (VR) simulators are now available and ready for widespread use. Early systems have demonstrated their effectiveness and discriminative ability. Newer systems enable the development of comprehensive curricula and full procedural simulations. A PubMed review of the literature was performed for the MESH words "Virtual reality, "Augmented Reality", "Simulation", "Training", and "Neurosurgery". Relevant articles were retrieved and reviewed. A review of the literature was performed for the history, current status of VR simulation in neurosurgery. Surgical organizations are calling for methods to ensure the maintenance of skills, advance surgical training, and credential surgeons as technically competent. The number of published literature discussing the application of VR simulation in neurosurgery training has evolved over the last decade from data visualization, including stereoscopic evaluation to more complex augmented reality models. With the revolution of computational analysis abilities, fully immersive VR models are currently available in neurosurgery training. Ventriculostomy catheters insertion, endoscopic and endovascular simulations are used in neurosurgical residency training centers across the world. Recent studies have shown the coloration of proficiency with those simulators and levels of experience in the real world. Fully immersive technology is starting to be applied to the practice of neurosurgery. In the near future, detailed VR neurosurgical modules will evolve to be an essential part of the curriculum of the training of neurosurgeons.


  • GPU-based elastic-object deformation for enhancement of existing haptic applications

    by Cristian J. Luciano, P. Pat Banerjee, Silvio H. R. Rizzi

    Most haptic libraries allow user to feel the resistance of a flexible virtual object by the implementation of a point-based collision detection algorithm and a spring-damper model. Even though the user can feel the deformation at the contact point, the graphics library renders a rigid geometry, causing a conflict of senses in the user's mind. In most cases, the CPU utilization is maximized to achieve the required 1-kHz haptic frame rate without leaving any additional resource to also deform the geometry, while on the other hand, the Graphics Processing Unit (GPU) is underutilized. This paper proposes a computationally inexpensive and efficient GPU-based methodology to significantly enhance user perception of large existing haptic applications without compromising the original haptic feedback. To the best of our knowledge, this is the first implemented algorithm that is able to maintain a graphics frame rate of approximately 60 Hz as well as a haptics frame rate of 1 Khz when deforming complex geometry of approximately 160K vertices. The implementation of the algorithm in a virtual reality neurosurgical simulator has been successful to handle, in real time, complex 3D isosurfaces created from medical MRI and CT images.


  • Automating the Extraction of 3D Models from Medical Images for Virtual Reality and Haptic Simulations

    by Silvio H. Rizzi, P. Pat Banerjee, Cristian J. Luciano

    The Sensimmer platform represents our ongoing research on simultaneous haptics and graphics rendering of 3D models. For simulation of medical and surgical procedures using Sensimmer, 3D models must be obtained from medical imaging data, such as Magnetic Resonance Imaging (MRI) or Computed Tomography (CT). Image segmentation techniques are used to determine the anatomies of interest from the images. 3D models are obtained from segmentation and their triangle reduction is required for graphics and haptics rendering. This paper focuses on creating an integrated interface between Sensimmer and medical imaging devices, using available software. Existing tools are evaluated, as well as aspects that require further development are identified. Solutions to overcome limitations and increase the degree of automation of the process are examined.