Cristian Luciano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cristian Luciano has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Pat Banerjee
University of Illinois at Chicago
4 shared publications - Silvio H. Rizzi
Department of Mechanical and Industrial Engineering, University of Illinois, Chicago, IL 60607 USA
4 shared publications - Adam Wallace
Division of Neurointerventional Radiology, Neuroscience Institute, Abbott Northwestern Hospital, Minneapolis, MN, United States; Department of Radiology, University of Iowa, Iowa City, IA, United States
1 shared publication - Ali Alaraj
University of Illinois at Chicago
1 shared publication - Chiara Di Vece
University College London
1 shared publication - Craig Niederberger
Department of Urology, University of Illinois at Chicago , Chicago, IL
1 shared publication
Latest Publications
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 4908-4911
CathSym: Device and Method to Bring Haptic Feedback to Urinary Catheterization Training
Urinary catheterization is one of the most widely taught procedures in the medical field. Current simulation-based training methods allow the students to be trained on non-realistic mannequins that do not adequately develop their psychomotor skills. This lack of proper training translates into increased likelihood of the medical professional causing damage to the patients’ urethra in the form of false passages when faced with a difficult catheterization. The leading cause of this damage is the overuse of force that diverts the catheter head into the soft tissue. With the emergence of haptic feedback and virtual training into the medical field, we aimed to design and build a novel haptics-based mixed reality simulation trainer for teaching urinary catheterization. We developed a software system accompanied with a customized haptic feedback device to help the user train in various catheterization scenarios to gain experience for improving their psychomotor skills and teach them to navigate blockages and other anatomies in the urethra. Our simulation platform has the potential to adequately provde the trainees with realistic force and visual feedback that are representative of what the user might experience in real world Foley catheterization.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 4908-4911
CathSym: Device and Method to Bring Haptic Feedback to Urinary Catheterization Training
Urinary catheterization is one of the most widely taught procedures in the medical field. Current simulation-based training methods allow the students to be trained on non-realistic mannequins that do not adequately develop their psychomotor skills. This lack of proper training translates into increased likelihood of the medical professional causing damage to the patients’ urethra in the form of false passages when faced with a difficult catheterization. The leading cause of this damage is the overuse of force that diverts the catheter head into the soft tissue. With the emergence of haptic feedback and virtual training into the medical field, we aimed to design and build a novel haptics-based mixed reality simulation trainer for teaching urinary catheterization. We developed a software system accompanied with a customized haptic feedback device to help the user train in various catheterization scenarios to gain experience for improving their psychomotor skills and teach them to navigate blockages and other anatomies in the urethra. Our simulation platform has the potential to adequately provde the trainees with realistic force and visual feedback that are representative of what the user might experience in real world Foley catheterization.
- Open Access
- 12 March 2021
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 16 (4) , 639-647
Psychomotor skills development for Veress needle placement using a virtual reality and haptics-based simulator
Purpose: Veress needle (VN) insertion, if not correctly performed, could cause severe injuries to intra-abdominal organs and vessels. Therefore, cognitive and psychomotor skills training is needed. Virtual reality (VR) and haptic technologies have the potential to offer realistic simulations.Methods: We developed a novel VR and haptic surgical simulator for VN insertion to teach trainees how to correctly puncture the abdominal wall, experiencing realistic tactile sensations throughout the simulation. The simulator allows for both procedural and realistic training. We released two different versions: the first using the OpenHaptics $$^{\text {TM}}$$ (OH) Toolkit and the second exploiting CHAI3D. We evaluated the learning effect using different performance indexes (time to perform the procedure, error in insertion angle, number of undesired contacts with organs) in an insertion task for both experienced urologists and students.Results: A general improvement of the chosen performance indexes was registered in the second repetition of the task for both groups. From the questionnaires, the simulator leveraging OH provides the trainee with a more precise haptic feedback, whereas the one exploiting CHAI3D allows them to perform the procedure more easily thanks to the better visualization of the virtual environment. The results proved that the participants appreciated both implementations, and the System Usability Scale (SUS) test resulted in a “good” usability.Conclusion: The haptics-based and VR simulator has shown the potential to be an important resource for the basic urological training in obtaining the pneumoperitoneum and improving the acquisition of the necessary psychomotor skills, allowing for extended and more effective training without compromising patient safety.- 12 March 2021
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 16 (4) , 639-647
Open AccessPsychomotor skills development for Veress needle placement using a virtual reality and haptics-based simulator
Purpose: Veress needle (VN) insertion, if not correctly performed, could cause severe injuries to intra-abdominal organs and vessels. Therefore, cognitive and psychomotor skills training is needed. Virtual reality (VR) and haptic technologies have the potential to offer realistic simulations.Methods: We developed a novel VR and haptic surgical simulator for VN insertion to teach trainees how to correctly puncture the abdominal wall, experiencing realistic tactile sensations throughout the simulation. The simulator allows for both procedural and realistic training. We released two different versions: the first using the OpenHaptics $$^{\text {TM}}$$ (OH) Toolkit and the second exploiting CHAI3D. We evaluated the learning effect using different performance indexes (time to perform the procedure, error in insertion angle, number of undesired contacts with organs) in an insertion task for both experienced urologists and students.Results: A general improvement of the chosen performance indexes was registered in the second repetition of the task for both groups. From the questionnaires, the simulator leveraging OH provides the trainee with a more precise haptic feedback, whereas the one exploiting CHAI3D allows them to perform the procedure more easily thanks to the better visualization of the virtual environment. The results proved that the participants appreciated both implementations, and the System Usability Scale (SUS) test resulted in a “good” usability.Conclusion: The haptics-based and VR simulator has shown the potential to be an important resource for the basic urological training in obtaining the pneumoperitoneum and improving the acquisition of the necessary psychomotor skills, allowing for extended and more effective training without compromising patient safety. - Open Access
- 4 July 2016
- Published by Sociedade Brasileira de Computação
Protocolo de comunicaciones para control de la generación distribuida de flujo multimedia
Aplicaciones de tiempo real como realidad virtual generan un flujo multimedia de tipo de máquina-humano que puede ser dividido tanto espacial como temporalmente para distribuir recursos de procesamiento, memoria o red. Este trabajo describe un protocolo para control de flujo de datos multimedia, donde su generación debe ser distribuida para incrementar el rendimiento. Este protocolo no describe la comunicación del flujo multimedia, sino solamente la comunicación de control para la generación de un único flujo multimedia entre múltiples nodos teniendo en cuenta un esquema de mejor esfuerzo. Para lograr estos objetivos se propone un protocolo de capa de aplicación, el cual utiliza UDP o UDP-lite en capa de transporte, IPv6 multicast en capa de red y Gigabit Ethernet con control de flujo en capa de enlace de datos.
- 4 July 2016
- Published by Sociedade Brasileira de Computação
Open AccessProtocolo de comunicaciones para control de la generación distribuida de flujo multimedia
Aplicaciones de tiempo real como realidad virtual generan un flujo multimedia de tipo de máquina-humano que puede ser dividido tanto espacial como temporalmente para distribuir recursos de procesamiento, memoria o red. Este trabajo describe un protocolo para control de flujo de datos multimedia, donde su generación debe ser distribuida para incrementar el rendimiento. Este protocolo no describe la comunicación del flujo multimedia, sino solamente la comunicación de control para la generación de un único flujo multimedia entre múltiples nodos teniendo en cuenta un esquema de mejor esfuerzo. Para lograr estos objetivos se propone un protocolo de capa de aplicación, el cual utiliza UDP o UDP-lite en capa de transporte, IPv6 multicast en capa de red y Gigabit Ethernet con control de flujo en capa de enlace de datos.
- 19 March 2012
- Published by Wiley in Journal of Computing and Information Science in Engineering
- Vol. 12 (2) , 021004
Comparison of Algorithms for Haptic Interaction With Isosurfaces Extracted From Volumetric Datasets
Combinations of graphics and haptics libraries are used in medical simulations for simultaneous visualization and tactile interaction with complex 3D anatomy models. The minimum frame rate of 1 kHz for haptics rendering makes it a nontrivial problem when dealing with complex and highly detailed polygonal models. Multiple haptics algorithms based on polygonal mesh rendering, volume haptics, and intermediate representation are evaluated in terms of their servoloop rendering time, client thread rendering time, and quality of force feedback. Algorithms include OpenHaptics’ Feedback Buffer and Depth Buffer, GodObject and Ruspini renderers in h3d, chai3d implementation in h3d, ScalarSurfaceFriction mode in Volume Haptics ToolKit (vhtk), and the authors’ intermediate representation algorithm based on volumetric data. The latter, in combination with surface graphics visualization, is found to deliver the best rendering time, to detect all collisions and to provide correct haptic feedback where other algorithms fail.
- 19 March 2012
- Published by Wiley in Journal of Computing and Information Science in Engineering
- Vol. 12 (2) , 021004
Comparison of Algorithms for Haptic Interaction With Isosurfaces Extracted From Volumetric Datasets
Combinations of graphics and haptics libraries are used in medical simulations for simultaneous visualization and tactile interaction with complex 3D anatomy models. The minimum frame rate of 1 kHz for haptics rendering makes it a nontrivial problem when dealing with complex and highly detailed polygonal models. Multiple haptics algorithms based on polygonal mesh rendering, volume haptics, and intermediate representation are evaluated in terms of their servoloop rendering time, client thread rendering time, and quality of force feedback. Algorithms include OpenHaptics’ Feedback Buffer and Depth Buffer, GodObject and Ruspini renderers in h3d, chai3d implementation in h3d, ScalarSurfaceFriction mode in Volume Haptics ToolKit (vhtk), and the authors’ intermediate representation algorithm based on volumetric data. The latter, in combination with surface graphics visualization, is found to deliver the best rendering time, to detect all collisions and to provide correct haptic feedback where other algorithms fail.
- Top Cited PapersOpen Access
- 1 January 2011
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 2 (1) , 52
Virtual reality training in neurosurgery: Review of current status and future applications
Over years, surgical training is changing and years of tradition are being challenged by legal and ethical concerns for patient safety, work hour restrictions, and the cost of operating room time. Surgical simulation and skill training offer an opportunity to teach and practice advanced techniques before attempting them on patients. Simulation training can be as straightforward as using real instruments and video equipment to manipulate simulated "tissue" in a box trainer. More advanced virtual reality (VR) simulators are now available and ready for widespread use. Early systems have demonstrated their effectiveness and discriminative ability. Newer systems enable the development of comprehensive curricula and full procedural simulations. A PubMed review of the literature was performed for the MESH words "Virtual reality, "Augmented Reality", "Simulation", "Training", and "Neurosurgery". Relevant articles were retrieved and reviewed. A review of the literature was performed for the history, current status of VR simulation in neurosurgery. Surgical organizations are calling for methods to ensure the maintenance of skills, advance surgical training, and credential surgeons as technically competent. The number of published literature discussing the application of VR simulation in neurosurgery training has evolved over the last decade from data visualization, including stereoscopic evaluation to more complex augmented reality models. With the revolution of computational analysis abilities, fully immersive VR models are currently available in neurosurgery training. Ventriculostomy catheters insertion, endoscopic and endovascular simulations are used in neurosurgical residency training centers across the world. Recent studies have shown the coloration of proficiency with those simulators and levels of experience in the real world. Fully immersive technology is starting to be applied to the practice of neurosurgery. In the near future, detailed VR neurosurgical modules will evolve to be an essential part of the curriculum of the training of neurosurgeons.
- 1 January 2011
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 2 (1) , 52
Top Cited PapersOpen AccessVirtual reality training in neurosurgery: Review of current status and future applications
Over years, surgical training is changing and years of tradition are being challenged by legal and ethical concerns for patient safety, work hour restrictions, and the cost of operating room time. Surgical simulation and skill training offer an opportunity to teach and practice advanced techniques before attempting them on patients. Simulation training can be as straightforward as using real instruments and video equipment to manipulate simulated "tissue" in a box trainer. More advanced virtual reality (VR) simulators are now available and ready for widespread use. Early systems have demonstrated their effectiveness and discriminative ability. Newer systems enable the development of comprehensive curricula and full procedural simulations. A PubMed review of the literature was performed for the MESH words "Virtual reality, "Augmented Reality", "Simulation", "Training", and "Neurosurgery". Relevant articles were retrieved and reviewed. A review of the literature was performed for the history, current status of VR simulation in neurosurgery. Surgical organizations are calling for methods to ensure the maintenance of skills, advance surgical training, and credential surgeons as technically competent. The number of published literature discussing the application of VR simulation in neurosurgery training has evolved over the last decade from data visualization, including stereoscopic evaluation to more complex augmented reality models. With the revolution of computational analysis abilities, fully immersive VR models are currently available in neurosurgery training. Ventriculostomy catheters insertion, endoscopic and endovascular simulations are used in neurosurgical residency training centers across the world. Recent studies have shown the coloration of proficiency with those simulators and levels of experience in the real world. Fully immersive technology is starting to be applied to the practice of neurosurgery. In the near future, detailed VR neurosurgical modules will evolve to be an essential part of the curriculum of the training of neurosurgeons.
- 13 February 2009
- Published by Springer Nature in Virtual Reality
- Vol. 13 (2) , 69-85
Haptics-based virtual reality periodontal training simulator
- 13 February 2009
- Published by Springer Nature in Virtual Reality
- Vol. 13 (2) , 69-85
Haptics-based virtual reality periodontal training simulator
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 146-151
GPU-based elastic-object deformation for enhancement of existing haptic applications
Most haptic libraries allow user to feel the resistance of a flexible virtual object by the implementation of a point-based collision detection algorithm and a spring-damper model. Even though the user can feel the deformation at the contact point, the graphics library renders a rigid geometry, causing a conflict of senses in the user's mind. In most cases, the CPU utilization is maximized to achieve the required 1-kHz haptic frame rate without leaving any additional resource to also deform the geometry, while on the other hand, the Graphics Processing Unit (GPU) is underutilized. This paper proposes a computationally inexpensive and efficient GPU-based methodology to significantly enhance user perception of large existing haptic applications without compromising the original haptic feedback. To the best of our knowledge, this is the first implemented algorithm that is able to maintain a graphics frame rate of approximately 60 Hz as well as a haptics frame rate of 1 Khz when deforming complex geometry of approximately 160K vertices. The implementation of the algorithm in a virtual reality neurosurgical simulator has been successful to handle, in real time, complex 3D isosurfaces created from medical MRI and CT images.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 146-151
GPU-based elastic-object deformation for enhancement of existing haptic applications
Most haptic libraries allow user to feel the resistance of a flexible virtual object by the implementation of a point-based collision detection algorithm and a spring-damper model. Even though the user can feel the deformation at the contact point, the graphics library renders a rigid geometry, causing a conflict of senses in the user's mind. In most cases, the CPU utilization is maximized to achieve the required 1-kHz haptic frame rate without leaving any additional resource to also deform the geometry, while on the other hand, the Graphics Processing Unit (GPU) is underutilized. This paper proposes a computationally inexpensive and efficient GPU-based methodology to significantly enhance user perception of large existing haptic applications without compromising the original haptic feedback. To the best of our knowledge, this is the first implemented algorithm that is able to maintain a graphics frame rate of approximately 60 Hz as well as a haptics frame rate of 1 Khz when deforming complex geometry of approximately 160K vertices. The implementation of the algorithm in a virtual reality neurosurgical simulator has been successful to handle, in real time, complex 3D isosurfaces created from medical MRI and CT images.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21618070,p. 152-157
Automating the Extraction of 3D Models from Medical Images for Virtual Reality and Haptic Simulations
The Sensimmer platform represents our ongoing research on simultaneous haptics and graphics rendering of 3D models. For simulation of medical and surgical procedures using Sensimmer, 3D models must be obtained from medical imaging data, such as Magnetic Resonance Imaging (MRI) or Computed Tomography (CT). Image segmentation techniques are used to determine the anatomies of interest from the images. 3D models are obtained from segmentation and their triangle reduction is required for graphics and haptics rendering. This paper focuses on creating an integrated interface between Sensimmer and medical imaging devices, using available software. Existing tools are evaluated, as well as aspects that require further development are identified. Solutions to overcome limitations and increase the degree of automation of the process are examined.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21618070,p. 152-157
Automating the Extraction of 3D Models from Medical Images for Virtual Reality and Haptic Simulations
The Sensimmer platform represents our ongoing research on simultaneous haptics and graphics rendering of 3D models. For simulation of medical and surgical procedures using Sensimmer, 3D models must be obtained from medical imaging data, such as Magnetic Resonance Imaging (MRI) or Computed Tomography (CT). Image segmentation techniques are used to determine the anatomies of interest from the images. 3D models are obtained from segmentation and their triangle reduction is required for graphics and haptics rendering. This paper focuses on creating an integrated interface between Sensimmer and medical imaging devices, using available software. Existing tools are evaluated, as well as aspects that require further development are identified. Solutions to overcome limitations and increase the degree of automation of the process are examined.
- 1 January 2006
- Vol. 119, 343-8
Second generation haptic ventriculostomy simulator using the ImmersiveTouch system.
Ventriculostomy is a neurosurgical procedure that consists of the insertion of a catheter into the ventricles of the brain for relieving the intracranial pressure. A distinct "popping" sensation is felt as the catheter enters the ventricles. Early ventriculostomy simulators provided some basic audio/visual feedback to simulate the procedure, displaying a 3D virtual model of a human head. Without any tactile feedback, the usefulness of such simulators was very limited. The first generation haptic ventriculostomy simulators incorporated a haptic device to generate a virtual resistance and "give" upon ventricular entry. While this created considerable excitement as a novelty device for cannulating ventricles, its usefulness for teaching and measuring neurosurgical expertise was still very limited. Poor collocation between the haptic device stylus held by the surgeon and the visual representation of the virtual catheter, as well as the lack of a correct viewer-centered perspective, created enormous confusion for the neurosurgeons who diverted their attention from the actual ventriculostomy procedure to overcoming the limitations of the simulator. We present a second generation haptic ventriculostomy simulator succeeding over the major first generation limitations by introducing a head and hand tracking system as well as a high-resolution high-visual-acuity stereoscopic display to enhance the perception and realism of the virtual ventriculostomy.
- 1 January 2006
- Vol. 119, 343-8
Second generation haptic ventriculostomy simulator using the ImmersiveTouch system.
Ventriculostomy is a neurosurgical procedure that consists of the insertion of a catheter into the ventricles of the brain for relieving the intracranial pressure. A distinct "popping" sensation is felt as the catheter enters the ventricles. Early ventriculostomy simulators provided some basic audio/visual feedback to simulate the procedure, displaying a 3D virtual model of a human head. Without any tactile feedback, the usefulness of such simulators was very limited. The first generation haptic ventriculostomy simulators incorporated a haptic device to generate a virtual resistance and "give" upon ventricular entry. While this created considerable excitement as a novelty device for cannulating ventricles, its usefulness for teaching and measuring neurosurgical expertise was still very limited. Poor collocation between the haptic device stylus held by the surgeon and the visual representation of the virtual catheter, as well as the lack of a correct viewer-centered perspective, created enormous confusion for the neurosurgeons who diverted their attention from the actual ventriculostomy procedure to overcoming the limitations of the simulator. We present a second generation haptic ventriculostomy simulator succeeding over the major first generation limitations by introducing a head and hand tracking system as well as a high-resolution high-visual-acuity stereoscopic display to enhance the perception and realism of the virtual ventriculostomy.