HSHiroyuki Sato

Hiroyuki Sato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hiroyuki Sato has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Economic Dispatch Model of Nuclear High-Temperature Reactor with Hydrogen Cogeneration in Electricity Market

    by James Richards, Cristian Rabiti, Hiroyuki Sato, Xing L. Yan, Nolan Anderson

    Hydrogen produced without carbon emissions could be a useful fuel as nations look to decarbonize their electricity, transport, and industry sectors. Using the iodine–sulfur (IS) cycle coupled with a nuclear heat source is one method for producing hydrogen without the use of fossil fuels. An economic dispatch model was developed for a nuclear-driven IS system to determine hydrogen sale prices that would make such a system profitable. The system studied is the HTTR-GT/H2, a design for power and hydrogen cogeneration at the Japan Atomic Energy Agency’s High Temperature Engineering Test Reactor. This study focuses on the development of the economic model and the role that input data plays in the final calculated values. Using a historical price duration curve shows that the levelized cost of hydrogen (LCOH) or breakeven sale price of hydrogen would need to be 98.1 JPY/m3 or greater. Synthetic time histories were also used and found the LCOH to be 67.5 JPY/m3. The price duration input was found to have a significant effect on the LCOH. As such, great care should be used in these economic dispatch analyses to select reasonable input assumptions.


  • Open Access

    Methodology Development for Transient Flow Distribution Analysis in High Temperature Gas-Cooled Reactor

    by Takeshi Aoki, Hiroyuki Sato, Hirofumi Ohashi

    A core of the prismatic high temperature gas-cooled reactor (HTGR) will consists of fuel blocks, control rod guide blocks and replaceable reflector blocks with surrounding permanent reflector blocks. The core effective flowrate available for effective cooling of fuels, fuel blocks and control rod guide blocks has to be evaluated to confirm that maximum fuel temperature satisfies

  • Open Access

    Uncertainty analysis of toxic gas leakage accident in cogeneration high temperature gas-cooled reactor

    by Hiroyuki Sato, Hirofumi Ohashi

    An uncertainty analysis method for control room habitability under toxic gas leakage accidents in cogeneration high temperature gas-cooled reactor (HTGR) is proposed to support risk-informed design of the plant. The method is applied to representative toxic gas leakage accidents in a hydrogen production plant by thermochemical Iodine-Sulfur water splitting method coupled to the HTTR gas turbine test plant. Variable parameters are successfully selected for the inputs to uncertainty propagation analysis by sensitivity analysis. Epistemic and aleatory uncertainties for each variable parameter are identified and are propagated using Latin hypercube sampling. The analyses show that the suggested method can successfully characterize and quantify uncertainties in the toxic gas concentration in control room. One important finding is that impact of uncertainty in surface roughness height on toxic gas concentration in control room is significant. The uncertainty is due largely to the simplification of the modeling of obstacles that exists between the reactor building and hydrogen production plant. The results lead us to the conclusion that toxic gas dispersion behavior analysis should combine two evaluation methods: dense gas dispersion model and computational fluid dynamics simulation.


  • Uncertainty Analysis for Source Term Evaluation of High Temperature Gas-Cooled Reactor Under Accident Conditions—Identification of Influencing Factors in Loss-of-Forced Circulation Accidents

    by Yuki Honda, Hiroyuki Sato, Shigeaki Nakagawa, Hirofumi Ohashi

    One of the key elements in probabilistic risk assessment is the identification and characterization of uncertainties. This paper suggests a procedure to identify influencing factors for uncertainty in source term evaluation, which are important to risk of public dose. We propose the following six steps for the identification in a systematic manner in terms of completeness and transparency of the results using both a logic diagram based on basic equations and expert opinions: (1) identification of uncertainty factors based on engineering knowledge of accident scenario analysis; (2) derivation of factors at the level of physical phenomena and variable parameters by expansion of dynamic equation for the system and scenario to be investigated, (3) extraction of uncertainties in variable parameters; (4) selection of important factors based on sensitivity study results and engineering knowledge; (5) identification of important factors for uncertainty analysis using expert opinions; and (6) integration of selected factors in the aforementioned steps. The proposed approach is tested with a case study for a risk-dominant accident scenario in direct cycle high-temperature gas-cooled reactor (HTGR) plant. We use this approach for evaluating the fuel temperature in terms of reactor dynamics and thermal hydraulic characteristics during a depressurized loss-of-forced circulation (DLOFC) accident with the failure of mitigation systems such as control rod systems (CRS) in a representative HTGR plan. In total, six important factors and 16 influencing factors were successfully identified by the proposed method in the case study. The selected influencing factors can be used as input parameters in uncertainty propagation analysis.

  • Nuclear Heat Supply Fluctuation Tests by Non-Nuclear Heating With HTTR

    by Yoshitomo Inaba, Kenji Sekita, Takahiro Nemoto, Yuki Honda, Daisuke Tochio, Hiroyuki Sato, Shigeaki Nakagawa, Shoji Takada, Kazuhiro Sawa

    The nuclear heat utilization systems connected to high-temperature gas-cooled reactors (HTGRs) will be designed on the basis of non-nuclear-grade standards in terms of easier entry for the chemical plant companies and the construction economics of the systems. Therefore, it is necessary that the reactor operations can be continued even if abnormal events occur in the systems. The Japan Atomic Energy Agency has developed a calculation code to evaluate the absorption of thermal-load fluctuations by the reactors when the reactor operations are continued after such events, and has improved the code based on the high-temperature engineering test reactor (HTTR) operating data. However, there were insufficient data on the transient temperature behavior of the metallic components and the graphite core support structures corresponding to the fluctuation of the reactor inlet coolant temperature for further improvement of the code. Thus, nuclear heat supply fluctuation tests with the HTTR were carried out in non-nuclear heating operation to focus on the thermal effect. In the tests, the coolant helium gas temperature was heated to 120°C by the compression heat of the gas circulators in the HTTR, and a sufficiently large fluctuation of 17°C for the reactor inlet coolant was achieved by devising a new test procedure under the ideal condition without the effect of the nuclear power. Then, the temperature responses of the metallic components and the graphite core support structures were investigated. The test results adequately showed as predicted that the temperature responses of the metallic components are faster than those of the graphite blocks, and the mechanism of the thermal-load fluctuation absorption by the metallic components was clarified.


  • Investigation of absorption characteristics for thermal-load fluctuation using HTTR

    by Daisuke Tochio, Yuki Honda, Hiroyuki Sato, Kenji Sekita, Fumitaka Homma, Hiroaki Sawahata, Shoji Takada, Shigeaki Nakagawa

    A commercial very high-temperature gas-cooled reactor (VHTR) hydrogen cogeneration system named gas turbine high temperature reactor 300-cogeneration (GTHTR300C) is designed and developed in Japan Atomic Energy Agency (JAEA). Moreover, it has been planned that hydrogen production system and gas turbine system is connect to high-temperature engineering test reactor (HTTR). The reactor system is required to continue a stable and safety operation as well as a stable power supply in the case that thermal-load is fluctuated by the occurrence of abnormal event in the heat utilization system like as the hydrogen production facility. Then, it is necessary to confirm that the thermal-load fluctuation could be absorbed by the reactor system so as to continue the stable and safety operation. The thermal-load fluctuation absorption tests using the HTTR were planned to clarify the absorption characteristics of the HTGR system. However, it is difficult to clarify the phenomenon due to many kinds of fluctuation in nuclear thermal power in the reactor core. Moreover, the actual data regarding how the delay of the temperature response is effective for the reactor system had been gained quantitatively. The thermal-load fluctuation absorption tests without nuclear heating were planned and conducted in JAEA to clarify the absorption characteristic of thermal-load fluctuation mainly by the reactor and by the intermediate heat exchanger (IHX). The absorption characteristics of thermal-load fluctuation can be revealed with sufficient temperature fluctuation. So the tests were conducted with the primary coolant temperature 120 °C which is the start-up temperature of the HTTR. As a result it was revealed that the reactor has the larger absorption capacity of thermal-load fluctuation than the expected one and that the IHX can be contributed to the absorption of the thermal-load fluctuation generated in the heat utilization system in the reactor system. It was confirmed from their results that the reactor and the IHX has effective absorption capacity of the thermal-load fluctuation generated in the heat utilization system. Moreover, the calculation with the safety evaluation code based on RELAP5/MOD3 was performed. It was confirmed that the calculated temperature for the reactor is almost same to the measured one with the new analysis model. On the other hand, it was confirmed that the calculated temperature for the IHX decreased faster than the measured one due to smaller absorption capacity in the calculation model than that in actual one. It can be considered that the calculation for the IHX produces the conservative result. It was summarized that the safety evaluation code can represent the thermal-load fluctuation absorption behavior conservatively.


  • HTTR Demonstration Program for Nuclear Cogeneration of Hydrogen and Electricity

    by Hiroyuki Sato, Xing L. Yan, Junya Sumita, Atsuhiko Terada, Yukio Tachibana

    The Japan Atomic Energy Agency (JAEA) initiated a high-temperature engineering test reactor (HTTR) demonstration program in accordance with recommendations of a task force established by the Ministry of Education, Culture, Sports, Science and Technology according to the Strategic Energy Plan as of April 2014. This paper explains the outline of the HTTR demonstration program with a plant concept of the heat application system directed at establishing a high-temperature gas-cooled reactor (HTGR) cogeneration system with 950°C reactor outlet temperature for production of power and hydrogen as recommended by the task force. A commercial deployment strategy including a development plan for the helium gas turbine is also presented.


  • ICONE23-1662 Nuclear Heat Supply Fluctuation Test by Non-Nuclear Heating Using HTTR

    by Shoji Takada, Kenji Sekita, Takahiro Nemoto, Yuki Honda, Daisuke Tochio, Yoshitomo Inaba, Hiroyuki Sato, Shigeaki Nakagawa, Kazuhiro Sawa

    To investigate the safety design criteria of heat utilization system for the HTGRs, it is necessary to evaluate the effect of fluctuation of thermal load on the reactor. The nuclear heat supply fluctuation test by non-nuclear heating was carried out by devising a new test procedure to simulate the nuclear heat supply test which is carried out in the nuclear powered operation. The test data is used to verify the numerical code to calculate the temperature of core bottom structure to carry out the safety evaluation of abnormal events in the heat utilization system. In the test, while the helium gas temperature was heated up to 120 ℃ by compression heat of gas circulators, it is necessary to impose a sufficiently high disturbance in the reactor inlet temperature. However, there was a technical restriction in the heat release from final heat sink for cooling water freeze proofing during operation in winter, which is special to the low temperature non-nuclear heating test. As the results of improvement of test procedure, a sufficiently high temperature disturbance was imposed on the reactor inlet temperature. Thus, it was found that the response of temperatures of metallic components such as side shielding blocks was faster than those of graphite blocks in the core bottom structure. Such difference of temperature transient characteristics between the metallic core support structure and the graphite blocks was emerged. It was also found that the temperature response was significantly affected by the heat capacities of components, the level of imposed disturbance and heat transfer performance.

  • Open Access

    Validation and application of thermal hydraulic system code for analysis of helically coiled heat exchanger in high-temperature environment

    by Hiroyuki Sato, Hirofumi Ohashi, Shigeaki Nakagawa, Yukio Tachibana, Kazuhiko Kunitomi

    A qualification of the thermal hydraulic system code RELAP5 (reactor excursion leak analysis program) is conducted for the analysis of helically coiled heat exchangers used in a high-temperature environment. A set of closure models based on the past separate effect test are suggested and validated against the measured data in the high temperature engineering test reactor (HTTR). The modified code is then tested for the analysis of a representative nuclear hydrogen production system. The comparison of calculated and measured data with steady-state operation showed that the original heat transfer package in RELAP5 significantly underpredicts the peak heat transfer tube temperature in the intermediate heat exchanger (IHX), particularly when the inlet helium gas temperature exceeds 600 °C. In contrast, the prediction with the suggested model generally agreed well. Lower prediction of peak temperature was observed in outer shell due to the modeling capability in system codes. However, those and the other results from the analysis of the HTTR-IS system revealed that the simplification of the heat structure geometry in IHX with low operating shell temperature is acceptable. In conclusion, this study explores the applicability of the system code to safety analysis of nuclear hydrogen production systems by means of a newly introduced closure model.