DTDaisuke Tochio

Daisuke Tochio

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daisuke Tochio has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Loss of Core Cooling Test With One Cooling Line Inactive in Vessel Cooling System of High-Temperature Engineering Test Reactor

    by Yusuke Fujiwara, Takahiro Nemoto, Daisuke Tochio, Masanori Shinohara, Masato Ono, Shoji Takada

    In the high-temperature engineering test reactor (HTTR), the vessel cooling system (VCS) which is arranged around the reactor pressure vessel (RPV) removes residual heat and decay heat from the reactor core when the forced core cooling is lost. The test of loss of forced cooling (LOFC) when one of two cooling lines in VCS lost its cooling function was carried out to simulate the partial loss of cooling function from the surface of RPV using the HTTR at the reactor thermal power of 9 MW, under the condition that the reactor power control system and the reactor inlet coolant temperature control system were isolated, and three helium gas circulators (HGCs) in the primary cooling system (PCS) were stopped. The test results showed that the reactor power immediately decreased to almost zero, which is caused by negative feedback effect of reactivity, and became stable as soon as HGCs were stopped. On the other hand, the temperature changes of permanent reflector block, RPV, and the biological shielding concrete were quite slow during the test. The temperature decrease of RPV was several degrees during the test. The numerical result showed a good agreement with the test result of temperature rise of biological shielding concrete around 1 °C by the numerical method that uses a calibrated thermal resistance by using the measured temperatures of RPV and the air outside of biological shielding concrete. The temperature increase of water cooling tube panel of VCS was calculated to be about 15 °C which is sufficiently small in the view point of property protection. It was confirmed that the sufficient cooling capacity of VCS can be maintained even in case that one of two water cooling lines of VCS loses its function.


  • Nuclear Heat Supply Fluctuation Tests by Non-Nuclear Heating With HTTR

    by Yoshitomo Inaba, Kenji Sekita, Takahiro Nemoto, Yuki Honda, Daisuke Tochio, Hiroyuki Sato, Shigeaki Nakagawa, Shoji Takada, Kazuhiro Sawa

    The nuclear heat utilization systems connected to high-temperature gas-cooled reactors (HTGRs) will be designed on the basis of non-nuclear-grade standards in terms of easier entry for the chemical plant companies and the construction economics of the systems. Therefore, it is necessary that the reactor operations can be continued even if abnormal events occur in the systems. The Japan Atomic Energy Agency has developed a calculation code to evaluate the absorption of thermal-load fluctuations by the reactors when the reactor operations are continued after such events, and has improved the code based on the high-temperature engineering test reactor (HTTR) operating data. However, there were insufficient data on the transient temperature behavior of the metallic components and the graphite core support structures corresponding to the fluctuation of the reactor inlet coolant temperature for further improvement of the code. Thus, nuclear heat supply fluctuation tests with the HTTR were carried out in non-nuclear heating operation to focus on the thermal effect. In the tests, the coolant helium gas temperature was heated to 120°C by the compression heat of the gas circulators in the HTTR, and a sufficiently large fluctuation of 17°C for the reactor inlet coolant was achieved by devising a new test procedure under the ideal condition without the effect of the nuclear power. Then, the temperature responses of the metallic components and the graphite core support structures were investigated. The test results adequately showed as predicted that the temperature responses of the metallic components are faster than those of the graphite blocks, and the mechanism of the thermal-load fluctuation absorption by the metallic components was clarified.


  • Investigation of Countermeasure Against Local Temperature Rise in Vessel Cooling System in Loss of Core Cooling Test Without Nuclear Heating

    by Masato Ono, Atsushi Shimizu, Makoto Kondo, Yosuke Shimazaki, Masanori Shinohara, Daisuke Tochio, Kazuhiko Iigaki, Shigeaki Nakagawa, Shoji Takada, Kazuhiro Sawa

    In the loss of core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of the reactor core is stopped without inserting control rods into the core and, furthermore, without cooling by the vessel cooling system (VCS) to verify safety evaluation codes to investigate the inherent safety of high-temperature gas-cooled reactor (HTGR) be secured by natural phenomena to make it possible to design a severe accident-free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel (RPV) by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water-cooling tube without thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from helium gas circulators (HGCs) by stopping water flow in the VCS, the local higher temperature position was specified in the uncovered water-cooling tube of the VCS, although the temperature was sufficiently lower than the maximum allowable working temperature, and the natural circulation of water had an insufficient cooling effect on the temperature of the water-cooling tube below 1°C. Then, a new safe and secured procedure for the loss of core cooling test was established, which will be carried out soon after the restart of HTTR.

  • Investigation of absorption characteristics for thermal-load fluctuation using HTTR

    by Daisuke Tochio, Yuki Honda, Hiroyuki Sato, Kenji Sekita, Fumitaka Homma, Hiroaki Sawahata, Shoji Takada, Shigeaki Nakagawa

    A commercial very high-temperature gas-cooled reactor (VHTR) hydrogen cogeneration system named gas turbine high temperature reactor 300-cogeneration (GTHTR300C) is designed and developed in Japan Atomic Energy Agency (JAEA). Moreover, it has been planned that hydrogen production system and gas turbine system is connect to high-temperature engineering test reactor (HTTR). The reactor system is required to continue a stable and safety operation as well as a stable power supply in the case that thermal-load is fluctuated by the occurrence of abnormal event in the heat utilization system like as the hydrogen production facility. Then, it is necessary to confirm that the thermal-load fluctuation could be absorbed by the reactor system so as to continue the stable and safety operation. The thermal-load fluctuation absorption tests using the HTTR were planned to clarify the absorption characteristics of the HTGR system. However, it is difficult to clarify the phenomenon due to many kinds of fluctuation in nuclear thermal power in the reactor core. Moreover, the actual data regarding how the delay of the temperature response is effective for the reactor system had been gained quantitatively. The thermal-load fluctuation absorption tests without nuclear heating were planned and conducted in JAEA to clarify the absorption characteristic of thermal-load fluctuation mainly by the reactor and by the intermediate heat exchanger (IHX). The absorption characteristics of thermal-load fluctuation can be revealed with sufficient temperature fluctuation. So the tests were conducted with the primary coolant temperature 120 °C which is the start-up temperature of the HTTR. As a result it was revealed that the reactor has the larger absorption capacity of thermal-load fluctuation than the expected one and that the IHX can be contributed to the absorption of the thermal-load fluctuation generated in the heat utilization system in the reactor system. It was confirmed from their results that the reactor and the IHX has effective absorption capacity of the thermal-load fluctuation generated in the heat utilization system. Moreover, the calculation with the safety evaluation code based on RELAP5/MOD3 was performed. It was confirmed that the calculated temperature for the reactor is almost same to the measured one with the new analysis model. On the other hand, it was confirmed that the calculated temperature for the IHX decreased faster than the measured one due to smaller absorption capacity in the calculation model than that in actual one. It can be considered that the calculation for the IHX produces the conservative result. It was summarized that the safety evaluation code can represent the thermal-load fluctuation absorption behavior conservatively.


  • Thermal mixing characteristics of helium gas in high-temperature gas-cooled reactor, (I) thermal mixing behavior of helium gas in HTTR

    by Daisuke Tochio, Nozomu Fujimoto

    The future high-temperature gas-cooled reactor (HTGR) is now designed in Japan Atomic Energy Agency. The reactor has many merging points of helium gas with different temperatures. It is needed to clear the thermal mixing characteristics of helium gas at the pipe in the HTGR from the viewpoint of structure integrity and temperature control. Previously, the reactor inlet coolant temperature was controlled lower than specific one in the high-temperature engineering test reactor (HTTR) due to lack of mixing of helium gas in the primary cooling system. Now, the control system is improved to use the calculated bulk temperature of reactor inlet helium gas. In this paper, thermal–hydraulic analysis on the primary cooling system of the HTTR was conducted to clarify the thermal mixing behavior of helium gas. As a result, it was confirmed that the thermal mixing behavior is mainly affected by the aspect ratio of annular flow path, and it is needed to consider the mixing characteristics of helium gas at the piping design of the HTGR.


  • ICONE23-1662 Nuclear Heat Supply Fluctuation Test by Non-Nuclear Heating Using HTTR

    by Shoji Takada, Kenji Sekita, Takahiro Nemoto, Yuki Honda, Daisuke Tochio, Yoshitomo Inaba, Hiroyuki Sato, Shigeaki Nakagawa, Kazuhiro Sawa

    To investigate the safety design criteria of heat utilization system for the HTGRs, it is necessary to evaluate the effect of fluctuation of thermal load on the reactor. The nuclear heat supply fluctuation test by non-nuclear heating was carried out by devising a new test procedure to simulate the nuclear heat supply test which is carried out in the nuclear powered operation. The test data is used to verify the numerical code to calculate the temperature of core bottom structure to carry out the safety evaluation of abnormal events in the heat utilization system. In the test, while the helium gas temperature was heated up to 120 ℃ by compression heat of gas circulators, it is necessary to impose a sufficiently high disturbance in the reactor inlet temperature. However, there was a technical restriction in the heat release from final heat sink for cooling water freeze proofing during operation in winter, which is special to the low temperature non-nuclear heating test. As the results of improvement of test procedure, a sufficiently high temperature disturbance was imposed on the reactor inlet temperature. Thus, it was found that the response of temperatures of metallic components such as side shielding blocks was faster than those of graphite blocks in the core bottom structure. Such difference of temperature transient characteristics between the metallic core support structure and the graphite blocks was emerged. It was also found that the temperature response was significantly affected by the heat capacities of components, the level of imposed disturbance and heat transfer performance.

  • ICONE23-1636 Investigation of Characteristics of Natural Circulation of Water in Vessel Cooling System in Loss of Core Cooling Test without Nuclear Heating

    by Shoji Takada, Atsushi Shimizu, Makoto Kondo, Yosuke Shimazaki, Masanori Shinohara, Tomokazu Seki, Daisuke Tochio, Kazuhiko Iigaki, Shigeaki Nakagawa, Kazuhiro Sawa

    In the loss of forced core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of reactor core is stopped without inserting control rods into the core and cooling by Vessel Cooling System (VCS) to demonstrate the inherent safety of HTGR be secured by natural phenomena to make it possible to design a severe accident free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water cooling tube by thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from gas circulators with stopping water flow in the VCS, the local higher temperature position was specified although the temperature was sufficiently lower than the maximum allowable working temperature, and natural circulation of water had insufficient cooling effect on the temperature of water cooling tube below 1℃. Then, a new safe and secured procedure for the loss of forced core cooling test was established, which will be carried out soon after the restart of HTTR.

  • Open Access

    Evaluation of maximum fuel temperature in HTTR

    by Yoshitomo Inaba, Daisuke Tochio, Shohei Ueta, Shigeaki Nakagawa

    In order to ensure the thermal integrity of fuel in the high temperature engineering test reactor (HTTR), it is necessary that the maximum fuel temperature in the normal operation is to be lower than a thermal design limit of 1495°C. In the core thermal and hydraulic design of the HTTR, the maximum fuel temperature was estimated to be 1492°C, which satisfied the thermal design limit. However, the estimated temperature was derived by using hot spot factors with a large safety margin for the consideration of uncertainties in the design stage without the HTTR practical operating data, and thus there is no doubt that the estimated temperature includes excessive conservativeness. In order to obtain the maximum fuel temperature with appropriate conservativeness, the maximum fuel temperature has been re-evaluated on the basis of the HTTR operating data. In this paper, the random factors of the hot spot factors are revised by using the HTTR first fuel fabrication data, and the new maximum fuel temperature is estimated. As a result, the estimated maximum fuel temperature can be reduced to 1424°C. The reduction of the maximum fuel temperature leads to a larger thermal margin in nuclear and fuel designs.


  • Open Access

    Helium leak and chemical impurities control technology in HTTR

    by Daisuke Tochio, Atsushi Shimizu, Shimpei Hamamoto, Nariaki Sakaba

    Japan Atomic Energy Agency (JAEA) has designed and developed high-temperature gas-cooled reactor (HTGR) hydrogen cogeneration system named gas turbine high-temperature reactor (GTHTR300C) as a commercial HTGR. Helium gas is used as the primary coolant in HTGR. Helium gas is easy to leak, and the primary helium leakage should be controlled tightly from the viewpoint of preventing the release of radioactive materials to the environment. Moreover from the viewpoint of preventing the oxidization of graphite and metallic material, the helium coolant chemistry should be controlled tightly. The primary helium leakage and the helium coolant chemistry during the operation is the major factor in the HTGR for commercialization of HTGR system. This paper shows the design concept and the obtained operational experience on the primary helium leakage control and primary helium impurity control in the high-temperature engineering test reactor (HTTR) of JAEA. Moreover, the future plan to obtain operational experience of these controls for commercialization of HTGR system is shown.