Latest Publications

  • Polarimetric imaging for the diagnosis of cervical cancer

    by M. Anastasiadou, A. De Martino, D. Clement, F. Liège, B. Laude‐Boulesteix, N. Quang, J. Dreyfuss, B. Huynh, A. Nazac, L. Schwartz, et al.

    We present a first evaluation of polarimetric imaging in the degree of polarization (DOP) mode for cervical cancer detection. The preliminary results obtained with exvivo biopsies justified the development of a DOP imaging system adapted to commercial colposcope, for invivo studies. A clinical trial of this device is underway in order to compare this imaging modality with classical colposcopy for the visualisation of cervical precancerous or cancerous lesions.


  • Metrology of replicated diffractive optics with Mueller polarimetry in conical diffraction

    by Tatiana Novikova, Antonello De Martino, Pavel Bulkin, Quang Nguyen, Bernard Drévillon, Vladimir Popov, Alexander Chumakov

    The spectroscopic Mueller polarimetry in conical diffraction was applied for the metrological characterization of the one-dimensional (1D) holographic gratings, used for the fabrication of nanoimprint molding tool. First we characterized the master grating that consists of patterned resist layer on chromium-covered glass and then we studied replicated diffraction grating made of nickel. The experimental spectra of Mueller matrix of both samples taken at different azimuthal angles were fitted with symmetric trapezoidal model. The optimal values of gratings critical dimensions (CDs) and height were confirmed by atomic force microscopy (AFM) measurements. The calculated profiles of corresponding master and replica gratings are found to be complementary. We showed that Mueller polarimetry in conical diffraction, as a fast and non-contact optical characterization technique, can provide the basis for the metrology of the molding tool fabrication step in the nanoimprint technique.


  • Mueller polarimetric microscopy

    by Blandine Laude-Boulesteix, Antonello De Martino, Gilles Le Naour, Catherine Genestie, Laurent Schwartz, Enric Garcia-Caurel, Bernard Drevillon

    We present a multispectral polarimetric imaging system well suited for complete Mueller matrix microscopy. The source is a spectrally filtered halogen light bulb, and the image is formed on a fast CCD camera The light polarization is modulated before the sample and analyzed after the sample by using nematic liquid crystal modulators.. The whole Mueller matrix image of the sample is typically measured over 5 seconds for a good signal-to-noise ratio. The instrument design, together with an original and easy-to-operate calibration procedure provides a high polarimetric accuracy over wide ranges of wavelengths and magnifications. Mueller polarimetry provides separate images of scalar and vector retardation and dichroism of the sample, together with its depolarizing power, while all these effects do contribute simultaneously to the contrasts observed in standard polarized microsopy. Polarimetric images of several samples, namely an unstained rabbit cornea, a picrosirius red stained hepatic biopsy, and a rat artery specifically stained for collagen III are shown and discussed


  • Characterization of bidimensional gratings by spectroscopic ellipsometry and angle-resolved Mueller polarimetry

    by Bernard Kaplan, Tatiana Novikova, Antonello De Martino, Bernard Drévillon

    We studied two bidimensional square gratings of square holes formed in photoresist layers deposited on silicon wafers, both by classical spectroscopic ellipsometry (1.5–4.5-eV spectral range) at a constant incidence angle (70.7°) and by angle-resolved Mueller polarimetry at a constant wavelength (532 nm). The grating period was 1 μm in both directions, and the nominal hole sizes were 250 and 500 nm, respectively. The ellipsometric spectra were fitted by rigorous coupled-wave analysis simulations with two adjustable parameters, the resist layer thickness and the hole size. These parameters were found to be in good agreement with independent scanning electron microscopy measurements. The experimental angle-resolved Mueller spectra were remarkably well reproduced by the simulations, showing that angle-resolved Mueller polarimetry has a great potential for grating metrology applications.


  • Optimized Mueller polarimeter with liquid crystals

    by Antonello De Martino, Yong-Ki Kim, Enric Garcia-Caurel, Blandine Laude, Bernard Drévillon

    We demonstrate a Mueller polarimeter in which the polarization-state generator and analyzer are both composed of a linear polarizer and two liquid-crystal variable retarders. The polarimeter is designed to optimize the accuracy of the final results by minimization of the condition numbers of the modulation and analysis matrices. The polarimeter calibration, a difficult task by conventional procedures, is achieved easily by use of the eigenvalue method of Compain et al. [Appl. Opt. 38, 3490 (1999)]. The overall polarimeter performance is tested with a linear polarizer at various angles and a compensator at various retardations.


  • Three-dimensional microscopy through white light interferometry

    by Blandine Laude, Antonello De Martino, Bernard Drevillon, L Benattar, Laurent Schwartz

    A very simple OCT system has been developed, based on a Linnik interferometric microscope with its reference mirror mounted on a piezoelectric translator. The geometrical extension of the optics allows efficient illumination of this device with a low power (3 W) light bulb, yielding full field interferometric images at 50 Hz acquisition rate with a fast CCD camera. Due to the very broad spectral width of the light source and camera response, a longitudinal resolution of 1.5 micrometers is achieved. Tomographic images of cell smears are shown.