Bernard Drévillon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bernard Drévillon has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Antonello De Martino
Laboratoire de Physique des Interfaces et des Couches Minces, CNRS, Ecole Polytechnique, 91128 Palaiseau, France
3 shared publications Laurent Schwartz
Hopital de la Pitie-Salpetriere (France)
3 shared publications- Enric Garcia-Caurel
Ecole Polytechnique, LPICM
2 shared publications Alexander Chumakov
Moscow State Univ. (Russia)
1 shared publication- Blandine Laude
Laboratoire de Physique des Interfaces et des Couches Minces, Centre National de la Recherche Scientifique, Unite Mixte de Recherche 7647, Ecole Polytechnique, 91128 Palaiseau Cedex, France
1 shared publication Blandine Laude-Boulesteix
Lab. de Physique des Interfaces et des Couches Minces, CNRS (France)
1 shared publication
Latest Publications
- 16 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6518, 65184E
Metrology of replicated diffractive optics with Mueller polarimetry in conical diffraction
The spectroscopic Mueller polarimetry in conical diffraction was applied for the metrological characterization of the one-dimensional (1D) holographic gratings, used for the fabrication of nanoimprint molding tool. First we characterized the master grating that consists of patterned resist layer on chromium-covered glass and then we studied replicated diffraction grating made of nickel. The experimental spectra of Mueller matrix of both samples taken at different azimuthal angles were fitted with symmetric trapezoidal model. The optimal values of gratings critical dimensions (CDs) and height were confirmed by atomic force microscopy (AFM) measurements. The calculated profiles of corresponding master and replica gratings are found to be complementary. We showed that Mueller polarimetry in conical diffraction, as a fast and non-contact optical characterization technique, can provide the basis for the metrology of the molding tool fabrication step in the nanoimprint technique.
- 16 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6518, 65184E
Metrology of replicated diffractive optics with Mueller polarimetry in conical diffraction
The spectroscopic Mueller polarimetry in conical diffraction was applied for the metrological characterization of the one-dimensional (1D) holographic gratings, used for the fabrication of nanoimprint molding tool. First we characterized the master grating that consists of patterned resist layer on chromium-covered glass and then we studied replicated diffraction grating made of nickel. The experimental spectra of Mueller matrix of both samples taken at different azimuthal angles were fitted with symmetric trapezoidal model. The optimal values of gratings critical dimensions (CDs) and height were confirmed by atomic force microscopy (AFM) measurements. The calculated profiles of corresponding master and replica gratings are found to be complementary. We showed that Mueller polarimetry in conical diffraction, as a fast and non-contact optical characterization technique, can provide the basis for the metrology of the molding tool fabrication step in the nanoimprint technique.
- 13 July 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5324, 112-124
Mueller polarimetric microscopy
We present a multispectral polarimetric imaging system well suited for complete Mueller matrix microscopy. The source is a spectrally filtered halogen light bulb, and the image is formed on a fast CCD camera The light polarization is modulated before the sample and analyzed after the sample by using nematic liquid crystal modulators.. The whole Mueller matrix image of the sample is typically measured over 5 seconds for a good signal-to-noise ratio. The instrument design, together with an original and easy-to-operate calibration procedure provides a high polarimetric accuracy over wide ranges of wavelengths and magnifications. Mueller polarimetry provides separate images of scalar and vector retardation and dichroism of the sample, together with its depolarizing power, while all these effects do contribute simultaneously to the contrasts observed in standard polarized microsopy. Polarimetric images of several samples, namely an unstained rabbit cornea, a picrosirius red stained hepatic biopsy, and a rat artery specifically stained for collagen III are shown and discussed
- 13 July 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5324, 112-124
Mueller polarimetric microscopy
We present a multispectral polarimetric imaging system well suited for complete Mueller matrix microscopy. The source is a spectrally filtered halogen light bulb, and the image is formed on a fast CCD camera The light polarization is modulated before the sample and analyzed after the sample by using nematic liquid crystal modulators.. The whole Mueller matrix image of the sample is typically measured over 5 seconds for a good signal-to-noise ratio. The instrument design, together with an original and easy-to-operate calibration procedure provides a high polarimetric accuracy over wide ranges of wavelengths and magnifications. Mueller polarimetry provides separate images of scalar and vector retardation and dichroism of the sample, together with its depolarizing power, while all these effects do contribute simultaneously to the contrasts observed in standard polarized microsopy. Polarimetric images of several samples, namely an unstained rabbit cornea, a picrosirius red stained hepatic biopsy, and a rat artery specifically stained for collagen III are shown and discussed
- 1 January 2003
- Published by Optica Publishing Group
- p. 5141_249
Application of FTIR ellipsometry to detect and classify microorganisms
Here is presented a new method to detect and to classify microorganisms from their polarimetric response in the mid-infrared range (2-12 µm) measured by FTIR ellipsometry. Apart from the ellipsometric measurements, the performance of the method also stands on the simplicity of sample preparation and on the data analysis. Spectroscopic ellipsometry is a non-invasive optical characterization technique sensitive to the polarization of the light reflected or transmitted by a sample. The extreme sensitivity of ellipsometry allows the detection of minute changes on the sample surface, even at the monomolecular layer level. In the mid-infrared range each molecule exhibits a characteristic absorption fingerprint, thus making ellipsometry chemically selective. FTIR ellipsometry is used here for the first time to analyze bacteria grown in culture media. Sample preparation is extremely simple and consists of the evaporation of a droplet of an aqueous suspension of microorganisms on a planar surface. Ellipsometric measurements are performed on the solid residue left on the surface after the evaporation of the droplet. Data analysis can be divided in two steps. First, simplification of the measured spectra by Principal Component Analysis (PCA), which is one of the existing multivariate statistical techniques commonly used to eliminate redundant information. Second, classification of the simplified spectra using a standard clustering method. As a result, we show how this method can be employed to discriminate and identify bacteria at the species level. The results of this experiment are very promising for the application of ellipsometry for analytical purposes in biochemistry and in medicine.
- 1 January 2003
- Published by Optica Publishing Group
- p. 5141_249
Application of FTIR ellipsometry to detect and classify microorganisms
Here is presented a new method to detect and to classify microorganisms from their polarimetric response in the mid-infrared range (2-12 µm) measured by FTIR ellipsometry. Apart from the ellipsometric measurements, the performance of the method also stands on the simplicity of sample preparation and on the data analysis. Spectroscopic ellipsometry is a non-invasive optical characterization technique sensitive to the polarization of the light reflected or transmitted by a sample. The extreme sensitivity of ellipsometry allows the detection of minute changes on the sample surface, even at the monomolecular layer level. In the mid-infrared range each molecule exhibits a characteristic absorption fingerprint, thus making ellipsometry chemically selective. FTIR ellipsometry is used here for the first time to analyze bacteria grown in culture media. Sample preparation is extremely simple and consists of the evaporation of a droplet of an aqueous suspension of microorganisms on a planar surface. Ellipsometric measurements are performed on the solid residue left on the surface after the evaporation of the droplet. Data analysis can be divided in two steps. First, simplification of the measured spectra by Principal Component Analysis (PCA), which is one of the existing multivariate statistical techniques commonly used to eliminate redundant information. Second, classification of the simplified spectra using a standard clustering method. As a result, we show how this method can be employed to discriminate and identify bacteria at the species level. The results of this experiment are very promising for the application of ellipsometry for analytical purposes in biochemistry and in medicine.
- 17 May 2002
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4621, 1-8
Three-dimensional microscopy through white light interferometry
A very simple OCT system has been developed, based on a Linnik interferometric microscope with its reference mirror mounted on a piezoelectric translator. The geometrical extension of the optics allows efficient illumination of this device with a low power (3 W) light bulb, yielding full field interferometric images at 50 Hz acquisition rate with a fast CCD camera. Due to the very broad spectral width of the light source and camera response, a longitudinal resolution of 1.5 micrometers is achieved. Tomographic images of cell smears are shown.
- 17 May 2002
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4621, 1-8
Three-dimensional microscopy through white light interferometry
A very simple OCT system has been developed, based on a Linnik interferometric microscope with its reference mirror mounted on a piezoelectric translator. The geometrical extension of the optics allows efficient illumination of this device with a low power (3 W) light bulb, yielding full field interferometric images at 50 Hz acquisition rate with a fast CCD camera. Due to the very broad spectral width of the light source and camera response, a longitudinal resolution of 1.5 micrometers is achieved. Tomographic images of cell smears are shown.
- 1 August 1995
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 12 (8) , 1797-1804
Infrared ellipsometry study of the thickness-dependent vibration frequency shifts in silicon dioxide films
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 1 August 1995
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 12 (8) , 1797-1804
Infrared ellipsometry study of the thickness-dependent vibration frequency shifts in silicon dioxide films
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.