Peter Mortier
Research Subjects
Peter Mortier has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Matthieu De Beule
FEops NV, Technologiepark 122, 9052, Ghent, Belgium
6 shared publications- Patrick Segers
IBiTech-bioMMeda, Ghent University, Ghent, Belgium
5 shared publications Gianluca De Santis
FEops NV, Technologiepark-Zwijnaarde 122, 9052, Ghent, Belgium
4 shared publicationsGiorgia Rocatello
FEops NV , Technologiepark 122 , 9052 Ghent, Belgium
4 shared publicationsPeter de Jaegere
Department of Cardiology, Erasmus MC , Doctor Molewaterplein 40, 3015 GD Rotterdam, The Netherlands
3 shared publicationsBenedict Verhegghe
FEops, Ghent, Belgium; IBiTech-bioMMeda, Ghent University, Ghent, Belgium
2 shared publications
Latest Publications
- Open Access
- 20 August 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 2 (4) , 606-615
Towards patient-specific prediction of conduction abnormalities induced by transcatheter aortic valve implantation: a combined mechanistic modelling and machine learning approach
Post-procedure conduction abnormalities (CA) remain a common complication of transcatheter aortic valve implantation (TAVI), highlighting the need for personalized prediction models. We used machine learning (ML), integrating statistical and mechanistic modelling to provide a patient-specific estimation of the probability of developing CA after TAVI. The cohort consisted of 151 patients with normal conduction and no pacemaker at baseline who underwent TAVI in nine European centres. Devices included CoreValve, Evolut R, Evolut PRO, and Lotus. Preoperative multi-slice computed tomography was performed. Virtual valve implantation with patient-specific computer modelling and simulation (CM&S) allowed calculation of valve-induced contact pressure on the anatomy. The primary composite outcome was new onset left or right bundle branch block or permanent pacemaker implantation (PPI) before discharge. A supervised ML approach was applied with eight models predicting CA based on anatomical, procedural and mechanistic data. CA occurred in 59% of patients (n = 89), more often after mechanical than first or second generation self-expanding valves (68% vs. 60% vs. 41%). CM&S revealed significantly higher contact pressure and contact pressure index in patients with CA. The best model achieved 83% accuracy (area under the curve 0.84) and sensitivity, specificity, positive predictive value, negative predictive value, and F1-score of 100%, 62%, 76%, 100%, and 82%. ML, integrating statistical and mechanistic modelling, achieved an accurate prediction of CA after TAVI. This study demonstrates the potential of a synergetic approach for personalizing procedure planning, allowing selection of the optimal device and implantation strategy, avoiding new CA and/or PPI.
- 20 August 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 2 (4) , 606-615
Open AccessTowards patient-specific prediction of conduction abnormalities induced by transcatheter aortic valve implantation: a combined mechanistic modelling and machine learning approach
Post-procedure conduction abnormalities (CA) remain a common complication of transcatheter aortic valve implantation (TAVI), highlighting the need for personalized prediction models. We used machine learning (ML), integrating statistical and mechanistic modelling to provide a patient-specific estimation of the probability of developing CA after TAVI. The cohort consisted of 151 patients with normal conduction and no pacemaker at baseline who underwent TAVI in nine European centres. Devices included CoreValve, Evolut R, Evolut PRO, and Lotus. Preoperative multi-slice computed tomography was performed. Virtual valve implantation with patient-specific computer modelling and simulation (CM&S) allowed calculation of valve-induced contact pressure on the anatomy. The primary composite outcome was new onset left or right bundle branch block or permanent pacemaker implantation (PPI) before discharge. A supervised ML approach was applied with eight models predicting CA based on anatomical, procedural and mechanistic data. CA occurred in 59% of patients (n = 89), more often after mechanical than first or second generation self-expanding valves (68% vs. 60% vs. 41%). CM&S revealed significantly higher contact pressure and contact pressure index in patients with CA. The best model achieved 83% accuracy (area under the curve 0.84) and sensitivity, specificity, positive predictive value, negative predictive value, and F1-score of 100%, 62%, 76%, 100%, and 82%. ML, integrating statistical and mechanistic modelling, achieved an accurate prediction of CA after TAVI. This study demonstrates the potential of a synergetic approach for personalizing procedure planning, allowing selection of the optimal device and implantation strategy, avoiding new CA and/or PPI.
- 23 August 2019
- Published by Springer Nature in Journal of Cardiovascular Translational Research
- Vol. 12 (5) , 435-446
The Impact of Size and Position of a Mechanical Expandable Transcatheter Aortic Valve: Novel Insights Through Computational Modelling and Simulation
Transcatheter aortic valve implantation has become an established procedure to treat severe aortic stenosis. Correct device sizing/positioning is crucial for optimal outcome. Lotus valve sizing is based upon multiple aortic root dimensions. Hence, it often occurs that two valve sizes can be selected. In this study, patient-specific computer simulation is adopted to evaluate the influence of Lotus size/position on paravalvular aortic regurgitation (AR) and conduction abnormalities, in patients with equivocal aortic root dimensions. First, simulation was performed in 62 patients to validate the model in terms of predicted AR and conduction abnormalities using postoperative echocardiographic, angiographic and ECG-based data. Then, two Lotus sizes were simulated at two positions in patients with equivocal aortic root dimensions. Large valve size and deep position were associated with higher contact pressure, while only large size, not position, significantly reduced the predicted AR. Despite general trends, simulations revealed that optimal device size/position is patient-specific.
- 23 August 2019
- Published by Springer Nature in Journal of Cardiovascular Translational Research
- Vol. 12 (5) , 435-446
The Impact of Size and Position of a Mechanical Expandable Transcatheter Aortic Valve: Novel Insights Through Computational Modelling and Simulation
Transcatheter aortic valve implantation has become an established procedure to treat severe aortic stenosis. Correct device sizing/positioning is crucial for optimal outcome. Lotus valve sizing is based upon multiple aortic root dimensions. Hence, it often occurs that two valve sizes can be selected. In this study, patient-specific computer simulation is adopted to evaluate the influence of Lotus size/position on paravalvular aortic regurgitation (AR) and conduction abnormalities, in patients with equivocal aortic root dimensions. First, simulation was performed in 62 patients to validate the model in terms of predicted AR and conduction abnormalities using postoperative echocardiographic, angiographic and ECG-based data. Then, two Lotus sizes were simulated at two positions in patients with equivocal aortic root dimensions. Large valve size and deep position were associated with higher contact pressure, while only large size, not position, significantly reduced the predicted AR. Despite general trends, simulations revealed that optimal device size/position is patient-specific.
- 13 June 2019
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 10 (3) , 456-468
Optimization of a Transcatheter Heart Valve Frame Using Patient-Specific Computer Simulation
This study proposes a new framework to optimize the design of a transcatheter aortic valve through patient-specific finite element and fluid dynamics simulation.
- 13 June 2019
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 10 (3) , 456-468
Optimization of a Transcatheter Heart Valve Frame Using Patient-Specific Computer Simulation
This study proposes a new framework to optimize the design of a transcatheter aortic valve through patient-specific finite element and fluid dynamics simulation.
- Open Access
- 1 February 2018
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 11 (2) , e005344
Patient-Specific Computer Simulation to Elucidate the Role of Contact Pressure in the Development of New Conduction Abnormalities After Catheter-Based Implantation of a Self-Expanding Aortic Valve
Background—: The extent to which pressure generated by the valve on the aortic root plays a role in the genesis of conduction abnormalities after transcatheter aortic valve replacement (TAVR) is unknown. This study elucidates the role of contact pressure and contact pressure area in the development of conduction abnormalities after TAVR using patient-specific computer simulations. Methods and Results—: Finite-element computer simulations were performed to simulate TAVR of 112 patients who had undergone TAVR with the self-expanding CoreValve/Evolut R valve. On the basis of preoperative multi-slice computed tomography, a patient-specific region of the aortic root containing the atrioventricular conduction system was determined by identifying the membranous septum. Contact pressure and contact pressure index (percentage of area subjected to pressure) were quantified and compared in patients with and without new conduction abnormalities. Sixty-two patients (55%) developed a new left bundle branch block or a high-degree atrioventricular block after TAVR. Maximum contact pressure and contact pressure index (median [interquartile range]) were significantly higher in patients with compared with those without new conduction abnormalities (0.51 MPa [0.43–0.70 MPa] and 33% [22%–44%], respectively, versus 0.29 MPa [0.06–0.50 MPa] and 12% [1%–28%]). By multivariable regression analysis, only maximum contact pressure (odds ratio, 1.35; confidence interval, 1.1–1.7; P =0.01) and contact pressure index (odds ratio, 1.52; confidence interval, 1.1–2.1; P =0.01) were identified as independent predictors for conduction abnormalities, but not implantation depth. Conclusions—: Patient-specific computer simulations revealed that maximum contact pressure and contact pressure index are both associated with new conduction abnormalities after CoreValve/Evolut R implantation and can predict which patient will have conduction abnormalities.
- 1 February 2018
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 11 (2) , e005344
Open AccessPatient-Specific Computer Simulation to Elucidate the Role of Contact Pressure in the Development of New Conduction Abnormalities After Catheter-Based Implantation of a Self-Expanding Aortic Valve
Background—: The extent to which pressure generated by the valve on the aortic root plays a role in the genesis of conduction abnormalities after transcatheter aortic valve replacement (TAVR) is unknown. This study elucidates the role of contact pressure and contact pressure area in the development of conduction abnormalities after TAVR using patient-specific computer simulations. Methods and Results—: Finite-element computer simulations were performed to simulate TAVR of 112 patients who had undergone TAVR with the self-expanding CoreValve/Evolut R valve. On the basis of preoperative multi-slice computed tomography, a patient-specific region of the aortic root containing the atrioventricular conduction system was determined by identifying the membranous septum. Contact pressure and contact pressure index (percentage of area subjected to pressure) were quantified and compared in patients with and without new conduction abnormalities. Sixty-two patients (55%) developed a new left bundle branch block or a high-degree atrioventricular block after TAVR. Maximum contact pressure and contact pressure index (median [interquartile range]) were significantly higher in patients with compared with those without new conduction abnormalities (0.51 MPa [0.43–0.70 MPa] and 33% [22%–44%], respectively, versus 0.29 MPa [0.06–0.50 MPa] and 12% [1%–28%]). By multivariable regression analysis, only maximum contact pressure (odds ratio, 1.35; confidence interval, 1.1–1.7; P =0.01) and contact pressure index (odds ratio, 1.52; confidence interval, 1.1–2.1; P =0.01) were identified as independent predictors for conduction abnormalities, but not implantation depth. Conclusions—: Patient-specific computer simulations revealed that maximum contact pressure and contact pressure index are both associated with new conduction abnormalities after CoreValve/Evolut R implantation and can predict which patient will have conduction abnormalities.
- 1 March 2014
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 7 (3) , 325-333
Provisional Stenting of Coronary Bifurcations
- 1 March 2014
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 7 (3) , 325-333
Provisional Stenting of Coronary Bifurcations
- 1 July 2011
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 7 (3) , 369-376
Virtual bench testing of new generation coronary stents
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 July 2011
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 7 (3) , 369-376
Virtual bench testing of new generation coronary stents
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 January 2011
- Published by Radcliffe Medical Media Ltd in Interventional Cardiology: Reviews, Research, Resources
- Vol. 6 (2)
Improved Understanding of Stent Malapposition Using Virtual Bench Testing
Intravascular imaging techniques such as optical coherence tomography (OCT) and intravascular ultrasound (IVUS) are often used to assess strut apposition, but only provide limited insight into the three-dimensional appositioning behaviour of stents. Recently, a new approach has been introduced to study the phenomenon of incomplete stent apposition (ISA) based on finite element simulations. In this study, we employed this virtual strut apposition assessment technique in the setting of coronary bifurcation stenting and compared simulated strut–artery distances of two stent designs with actual measurements based on OCT imaging using a silicone model. Stenting of the main branch leads to malapposed struts in the proximal part and the average strut–artery distance in that region for the Integrity stent is 126 μm based on the simulation and 117±14 μm based on the OCT analysis. For the Multi-Link 8 stent, this average distance is 150 μm and 174±7 µm for the simulation and thein vitroOCT measurements respectively. In conclusion, the virtual assessment of strut appositioning results in similar strut–artery distances when compared with measurements based on OCT-visualisedin vitrostent deployments and could be used to optimise devices and procedures.
- 1 January 2011
- Published by Radcliffe Medical Media Ltd in Interventional Cardiology: Reviews, Research, Resources
- Vol. 6 (2)
Improved Understanding of Stent Malapposition Using Virtual Bench Testing
Intravascular imaging techniques such as optical coherence tomography (OCT) and intravascular ultrasound (IVUS) are often used to assess strut apposition, but only provide limited insight into the three-dimensional appositioning behaviour of stents. Recently, a new approach has been introduced to study the phenomenon of incomplete stent apposition (ISA) based on finite element simulations. In this study, we employed this virtual strut apposition assessment technique in the setting of coronary bifurcation stenting and compared simulated strut–artery distances of two stent designs with actual measurements based on OCT imaging using a silicone model. Stenting of the main branch leads to malapposed struts in the proximal part and the average strut–artery distance in that region for the Integrity stent is 126 μm based on the simulation and 117±14 μm based on the OCT analysis. For the Multi-Link 8 stent, this average distance is 150 μm and 174±7 µm for the simulation and thein vitroOCT measurements respectively. In conclusion, the virtual assessment of strut appositioning results in similar strut–artery distances when compared with measurements based on OCT-visualisedin vitrostent deployments and could be used to optimise devices and procedures.
- 1 December 2010
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 6 (J) , J53-J60
Coronary bifurcation stenting: insights from in vitro and virtual bench testing
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 December 2010
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 6 (J) , J53-J60
Coronary bifurcation stenting: insights from in vitro and virtual bench testing
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)