David Newman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Newman has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Paul Dorian
Arrhythmia Service, Saint Michael's Hospital, University of Toronto, Toronto, Canada
6 shared publicationsMiney Paquette
University of Toronto
4 shared publicationsMary Greene
Arrhythmia Service, Saint Michael's Hospital, University of Toronto, Toronto, Canada
3 shared publicationsAiala Barr
Division of Cardiology, St. Michael's Hospital, University of Toronto, Toronto, Canada
2 shared publicationsAnthony S.L. Tang
1 shared publicationArnold Pinter
1 shared publication
Latest Publications
- 1 July 2004
- Published by Elsevier in Heart Rhythm
- Vol. 1 (2) , 20-26
Quality of life as an endpoint for atrial fibrillation research: pitfalls and practice
- 1 July 2004
- Published by Elsevier in Heart Rhythm
- Vol. 1 (2) , 20-26
Quality of life as an endpoint for atrial fibrillation research: pitfalls and practice
- 4 March 2004
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 27 (3) , 373-378
Feasibility of Implantable Cardioverter Defibrillator Use in Elderly Patients:
This article addresses the feasibility and safety of ICD therapy in patients >80 years of age. Recent trials have expanded the indication for ICD implantation to include an increasing number and variety of patients. The feasibility of ICD implantation in elderly patients has not been adequately studied. A prospectively collected single center ICD database was analyzed to assess the safety and feasibility of ICD implantation in elderly patients. Patients were divided based on age into two groups (group 1: 70–79 years of age, n = 183; group 2: ≥80 years of age, n = 29). The two groups were similar in gender distribution, NYHA class, and indication for implantation. The actuarial survival was not significantly different between groups 1 and 2 (P > 0.05; primary endpoint), with a 1‐year survival of 91% and 93% in groups 1 and 2, respectively, (P = NS). The complication rates at the time of ICD implantation were similar in groups 1 and 2 (6.6% and 13.1%, respectively, P = 0.16). Age alone may not be sufficient criteria to exclude ICD implantation. The current consensus guidelines for ICD implantation appear to be generalizable to treating octogenarians who are otherwise medically fit. (PACE 2004; 27:373–378)
- 4 March 2004
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 27 (3) , 373-378
Feasibility of Implantable Cardioverter Defibrillator Use in Elderly Patients:
This article addresses the feasibility and safety of ICD therapy in patients >80 years of age. Recent trials have expanded the indication for ICD implantation to include an increasing number and variety of patients. The feasibility of ICD implantation in elderly patients has not been adequately studied. A prospectively collected single center ICD database was analyzed to assess the safety and feasibility of ICD implantation in elderly patients. Patients were divided based on age into two groups (group 1: 70–79 years of age, n = 183; group 2: ≥80 years of age, n = 29). The two groups were similar in gender distribution, NYHA class, and indication for implantation. The actuarial survival was not significantly different between groups 1 and 2 (P > 0.05; primary endpoint), with a 1‐year survival of 91% and 93% in groups 1 and 2, respectively, (P = NS). The complication rates at the time of ICD implantation were similar in groups 1 and 2 (6.6% and 13.1%, respectively, P = 0.16). Age alone may not be sufficient criteria to exclude ICD implantation. The current consensus guidelines for ICD implantation appear to be generalizable to treating octogenarians who are otherwise medically fit. (PACE 2004; 27:373–378)
- 1 December 2003
- Published by Springer Nature in Cardiac Electrophysiology Review
- Vol. 7 (4) , 401-405
Relationships between Pacing Mode and Quality of Life: Evidence from Randomized Clinical Trials
Although mode-dependent differences in mortality are for the moment unproven, establishing a health-related quality of life difference between assigned pacing modes would be useful. Such a difference, if one exists, should be ≥0.5 standard deviation units among scales using validated instruments to have significant clinical meaning. Two large data sets, the Canadian Trial of Physiological Pacing (CTOPP) and the Mode Selection Trial (MOST) both similar in design, largely failed to clearly establish such a significant difference. Another trial the Pacemaker Selection in the Elderly (PASE) did suggest that for sinus node disease, DDD-R pacing may lead to an improvement in quality of life mainly early post implant. Two other large trials, UK-PACE and DANPACE have yet to present quality of life related results. All published data have established that restoration of chronotropic competence by pacing leads to improvements in quality of life that are significant. In CTOPP an attempt to quantify a mode-dependent difference for a pacemaker syndrome suggested that the prevalence and clinical importance of pacemaker syndrome may be exaggerated. The relative ease of crossover from VVI-R to DDD, by device upgrade in CTOPP or by programming in MOST, may explain the 2.9% vs. 31% crossover rates seen in CTOPP vs. MOST respectively. Trials to date may have had a mode dependent difference undermined by possible adverse effects from right ventricular apical sites of pacing. Future trial data; DANPACE, sinus node disease AAI-R vs. DDD-R and PAVE, post AVJ ablation VVI-R vs. VVI-CRT, will asses in more detail the role of site of pacing as a factor in determining mode dependent outcomes in pacing.
- 1 December 2003
- Published by Springer Nature in Cardiac Electrophysiology Review
- Vol. 7 (4) , 401-405
Relationships between Pacing Mode and Quality of Life: Evidence from Randomized Clinical Trials
Although mode-dependent differences in mortality are for the moment unproven, establishing a health-related quality of life difference between assigned pacing modes would be useful. Such a difference, if one exists, should be ≥0.5 standard deviation units among scales using validated instruments to have significant clinical meaning. Two large data sets, the Canadian Trial of Physiological Pacing (CTOPP) and the Mode Selection Trial (MOST) both similar in design, largely failed to clearly establish such a significant difference. Another trial the Pacemaker Selection in the Elderly (PASE) did suggest that for sinus node disease, DDD-R pacing may lead to an improvement in quality of life mainly early post implant. Two other large trials, UK-PACE and DANPACE have yet to present quality of life related results. All published data have established that restoration of chronotropic competence by pacing leads to improvements in quality of life that are significant. In CTOPP an attempt to quantify a mode-dependent difference for a pacemaker syndrome suggested that the prevalence and clinical importance of pacemaker syndrome may be exaggerated. The relative ease of crossover from VVI-R to DDD, by device upgrade in CTOPP or by programming in MOST, may explain the 2.9% vs. 31% crossover rates seen in CTOPP vs. MOST respectively. Trials to date may have had a mode dependent difference undermined by possible adverse effects from right ventricular apical sites of pacing. Future trial data; DANPACE, sinus node disease AAI-R vs. DDD-R and PAVE, post AVJ ablation VVI-R vs. VVI-CRT, will asses in more detail the role of site of pacing as a factor in determining mode dependent outcomes in pacing.
- 1 June 2003
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 8 (3) , 215-220
Is Inappropriate Implantable Defibrillator Shock Therapy Predictable?
Objective: To identify implantable cardioverter defibrillator (ICD) patients who are at risk of receiving inappropriate shock. Background:Inappropriate ICD shock, usually from atrial fibrillation...
- 1 June 2003
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 8 (3) , 215-220
Is Inappropriate Implantable Defibrillator Shock Therapy Predictable?
Objective: To identify implantable cardioverter defibrillator (ICD) patients who are at risk of receiving inappropriate shock. Background:Inappropriate ICD shock, usually from atrial fibrillation...
- 1 May 2003
- Published by Elsevier in American Heart Journal
- Vol. 145 (5) , 841-846
Effect of an implantable cardioverter defibrillator with atrial detection and shock therapies on patient-perceived, health-related quality of life
- 1 May 2003
- Published by Elsevier in American Heart Journal
- Vol. 145 (5) , 841-846
Effect of an implantable cardioverter defibrillator with atrial detection and shock therapies on patient-perceived, health-related quality of life
- 1 March 2003
- Published by Elsevier in American Heart Journal
- Vol. 145 (3) , 430-437
Effect of pacing mode on health-related quality of life in the Canadian Trial of Physiologic Pacing
- 1 March 2003
- Published by Elsevier in American Heart Journal
- Vol. 145 (3) , 430-437
Effect of pacing mode on health-related quality of life in the Canadian Trial of Physiologic Pacing
- 31 January 2002
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 346 (5) , 383-384
Cesium-Induced Torsades de Pointes
Up to 50 percent of patients with cancer seek help in the form of alternative medicine.1 Such therapies may include cesium chloride, a blocker of the inward-rectifying potassium channel that is used in animal models to study the long-QT syndrome and torsades de pointes.2 We report a documented case of cesium-induced toxicity.
- 31 January 2002
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 346 (5) , 383-384
Cesium-Induced Torsades de Pointes
Up to 50 percent of patients with cancer seek help in the form of alternative medicine.1 Such therapies may include cesium chloride, a blocker of the inward-rectifying potassium channel that is used in animal models to study the long-QT syndrome and torsades de pointes.2 We report a documented case of cesium-induced toxicity.
- Open Access
- 1 July 2001
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 3 (3) , 195-200
Thrombogenicity of radiofrequency ablation procedures: what factors influence thrombin generation?
Aims. Thromboembolic complications have been reported after radiofrequency ablation but the low incidence of overt clinical events has been a limitation
- 1 July 2001
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 3 (3) , 195-200
Open AccessThrombogenicity of radiofrequency ablation procedures: what factors influence thrombin generation?
Aims. Thromboembolic complications have been reported after radiofrequency ablation but the low incidence of overt clinical events has been a limitation
- 14 January 2000
- Published by Oxford University Press (OUP) in Cardiovascular Research
- Vol. 45 (2) , 303-309
Effect of physiological mechanical perturbations on intact human myocardial repolarization
The objective of this study was to investigate the relationship between acute decreases in right ventricular volume during Valsalva strain (with resultant changes in autonomic neural tone) and measures of local endocardial repolarization time independent of heart rate and autonomic neural tone. Patients implanted with a stimulus to T wave (Stim-T) sensing pacemaker specially adapted to output a validate measure of beat to beat local repolarization (n = 9) performed Valsalva manoeuvers (40 mmHg for 15 s) while paced at a cycle length of 500 ms. Stim-T intervals were measured before and after autonomic blockade (Block: 0.03 mg/kg i.v. atropine +/- 0.15 mg/kg propranolol). Right ventricular end diastolic volume was estimated by simultaneous 2D-echocardiography. Without autonomic blockade, compared to baseline, repolarization significantly prolonged during Valsalva strain (1.1 +/- 0.7%) and shortened during release (-1.4 +/- 1.0%). After block, strain related repolarization prolongation was also observed (1.0 +/- 0.6%), with significantly less release related repolarization shortening (-0.8 +/- 0.8%) compared to pre-block (P < 0.05). Right ventricular end diastolic volume decreased during strain by 11 +/- 10 and 9 +/- 16% from baseline, pre- and post-block respectively (P < 0.05). In a chronically instrumented human model, an acute physiologic volume reduction modestly prolongs right ventricular repolarization independent of changes in rate or autonomic tone.
- 14 January 2000
- Published by Oxford University Press (OUP) in Cardiovascular Research
- Vol. 45 (2) , 303-309
Effect of physiological mechanical perturbations on intact human myocardial repolarization
The objective of this study was to investigate the relationship between acute decreases in right ventricular volume during Valsalva strain (with resultant changes in autonomic neural tone) and measures of local endocardial repolarization time independent of heart rate and autonomic neural tone. Patients implanted with a stimulus to T wave (Stim-T) sensing pacemaker specially adapted to output a validate measure of beat to beat local repolarization (n = 9) performed Valsalva manoeuvers (40 mmHg for 15 s) while paced at a cycle length of 500 ms. Stim-T intervals were measured before and after autonomic blockade (Block: 0.03 mg/kg i.v. atropine +/- 0.15 mg/kg propranolol). Right ventricular end diastolic volume was estimated by simultaneous 2D-echocardiography. Without autonomic blockade, compared to baseline, repolarization significantly prolonged during Valsalva strain (1.1 +/- 0.7%) and shortened during release (-1.4 +/- 1.0%). After block, strain related repolarization prolongation was also observed (1.0 +/- 0.6%), with significantly less release related repolarization shortening (-0.8 +/- 0.8%) compared to pre-block (P < 0.05). Right ventricular end diastolic volume decreased during strain by 11 +/- 10 and 9 +/- 16% from baseline, pre- and post-block respectively (P < 0.05). In a chronically instrumented human model, an acute physiologic volume reduction modestly prolongs right ventricular repolarization independent of changes in rate or autonomic tone.
- 1 September 1999
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 10 (9) , 1171-1179
Validation of a Noninvasive Measure of Local Myocardial Repolarization in a Conscious Human Model:
Rate Adaptation of Myocardial Repolarization. Introduction: A commercial pacemaker sensor measure of the unipolar endocardial stimulus to T wave interval may accurately reflect changes in the monophasic action potential duration at 90% repolarization (APD90). This sensor system was used to study the kinetics of adaptation of repolarization duration to changes in heart rate in humans. Methods and Results: Patients were studied using an external pacemaker capable of displaying all stimulus to T wave intervals for each paced beat. Right ventricular stimulation was delivered via the pacemaker and compared simultaneously to APD90. Steady‐state pacing was simulated by 60 seconds of pacing at cycle lengths (CLs) 350 to 700 msec. Adaptation to a new ventricular rate was analyzed with a sudden 200‐msec decrease in CL. The relation between repolarization measure and steady‐state CL (n = 16) was linear with a slope of 0.16 and 0.19 for APD90 and stimulus to T wave interval, respectively (P = NS). The adaptation of both repolarization measures to a sudden change in rate were best modeled by a biexponential function. Stimulus to T wave interval exhibited a parallel course to APD90, and an analysis of normalized differences between APD90 and stimulus to T wave interval followed an approximately normal distribution, with 93.5% of the paired differences within 2 SD of the mean. Conclusion: A pacemaker sensor measure of stimulus to T wave interval accurately parallels APD90, during both steady‐state and sudden changes in rate. Repolarization in human endocardium follows a linear relation to steady‐state CL and adapts to a new rate with a biexponential function. This model represents a novel method for studying human cardiac repolarization.
- 1 September 1999
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 10 (9) , 1171-1179
Validation of a Noninvasive Measure of Local Myocardial Repolarization in a Conscious Human Model:
Rate Adaptation of Myocardial Repolarization. Introduction: A commercial pacemaker sensor measure of the unipolar endocardial stimulus to T wave interval may accurately reflect changes in the monophasic action potential duration at 90% repolarization (APD90). This sensor system was used to study the kinetics of adaptation of repolarization duration to changes in heart rate in humans. Methods and Results: Patients were studied using an external pacemaker capable of displaying all stimulus to T wave intervals for each paced beat. Right ventricular stimulation was delivered via the pacemaker and compared simultaneously to APD90. Steady‐state pacing was simulated by 60 seconds of pacing at cycle lengths (CLs) 350 to 700 msec. Adaptation to a new ventricular rate was analyzed with a sudden 200‐msec decrease in CL. The relation between repolarization measure and steady‐state CL (n = 16) was linear with a slope of 0.16 and 0.19 for APD90 and stimulus to T wave interval, respectively (P = NS). The adaptation of both repolarization measures to a sudden change in rate were best modeled by a biexponential function. Stimulus to T wave interval exhibited a parallel course to APD90, and an analysis of normalized differences between APD90 and stimulus to T wave interval followed an approximately normal distribution, with 93.5% of the paired differences within 2 SD of the mean. Conclusion: A pacemaker sensor measure of stimulus to T wave interval accurately parallels APD90, during both steady‐state and sudden changes in rate. Repolarization in human endocardium follows a linear relation to steady‐state CL and adapts to a new rate with a biexponential function. This model represents a novel method for studying human cardiac repolarization.