Shunichi Uchiyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shunichi Uchiyama has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Yasushi Hasebe
Department of Life Science and Green Chemistry, Faculty of Engineering, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan
5 shared publications Hiroshi Hamana
Department of Applied Chemistry, Faculty of Engineering, Saitama Institute of Technology, Fukaya 1690, Saitama 369-0293, Japan
4 shared publicationsNaoyuki Sekioka
Department of Materials Science and Engineering, graduate school of Engineering, Saitama Institute of Technology, Fukaya 1690, Saitama 369-0293, Japan
4 shared publicationsXiuyun Wang
Department of Materials Science and Engineering, graduate school of Engineering, Saitama Institute of Technology, Fukaya 1690, Saitama 369-0293, Japan; School of Chemical Engineering, University of Liaoning, Anshan 114051, China
3 shared publications- Hiroaki Matsuura
Department of Life Science & Green Chemistry, Graduate School of Engineering, Saitama Institute of Technology
2 shared publications Hiroaki Watanabe
Department of Materials Science and Engineering, graduate school of Engineering, Saitama Institute of Technology, Fukaya 1690, Saitama 369-0293, Japan
2 shared publications
Latest Publications
- 2 March 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (17) , 3445-3449
Sensitive nitrite detection using a simple electrochemically aminated glassy carbon electrode
In this study, we demonstrate a sensitive nitrite detection method using a simple electrochemically aminated glassy carbon electrode (AGCE).
- 2 March 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (17) , 3445-3449
Sensitive nitrite detection using a simple electrochemically aminated glassy carbon electrode
In this study, we demonstrate a sensitive nitrite detection method using a simple electrochemically aminated glassy carbon electrode (AGCE).
- 29 October 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 88, 251-255
Observation of hydrogen oxidation wave using glassy carbon electrode fabricated by stepwise electrolyses in ammonium carbamate aqueous solution and hydrochloric acid
- 29 October 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 88, 251-255
Observation of hydrogen oxidation wave using glassy carbon electrode fabricated by stepwise electrolyses in ammonium carbamate aqueous solution and hydrochloric acid
- 31 December 2009
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 21, S96-S99
Bioelectrochemical conversion of urea to nitrogen using aminated carbon electrode
- 31 December 2009
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 21, S96-S99
Bioelectrochemical conversion of urea to nitrogen using aminated carbon electrode
- 1 January 2009
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 21, S13-S15
Long-term stabilization of enzyme activity by immobilizing enzyme colony in polymaleimidostyrene-modified micelles
- 1 January 2009
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 21, S13-S15
Long-term stabilization of enzyme activity by immobilizing enzyme colony in polymaleimidostyrene-modified micelles
- 13 June 2008
- Published by Taylor & Francis in Analytical Letters
- Vol. 41 (7) , 1173-1183
Amperometric Glucose Sensor Fabricated by Combining Glucose Oxidase Micelle Membrane and Aminated Glassy Carbon Electrode
An amperometric glucose biosensor based on the detection of the reduction of oxygen has been developed by combining an aminated glassy carbon electrode with a polystyrene (PS) membrane containing glucose oxidase (GOD) micelles. The structure of GOD micelles contained in PS membrane was observed by scanning electron microscope. The micelle has a roughly spherical shape, and the enzyme colony is contained inside the micelle. This glucose sensor exhibited good sensitivity with short response time (within 2 min). A good linear relationship was observed in the concentration range of 0.2 mM to 2.6 mM when the applied potential was − 0.45 V vs. Ag/AgCl.
- 13 June 2008
- Published by Taylor & Francis in Analytical Letters
- Vol. 41 (7) , 1173-1183
Amperometric Glucose Sensor Fabricated by Combining Glucose Oxidase Micelle Membrane and Aminated Glassy Carbon Electrode
An amperometric glucose biosensor based on the detection of the reduction of oxygen has been developed by combining an aminated glassy carbon electrode with a polystyrene (PS) membrane containing glucose oxidase (GOD) micelles. The structure of GOD micelles contained in PS membrane was observed by scanning electron microscope. The micelle has a roughly spherical shape, and the enzyme colony is contained inside the micelle. This glucose sensor exhibited good sensitivity with short response time (within 2 min). A good linear relationship was observed in the concentration range of 0.2 mM to 2.6 mM when the applied potential was − 0.45 V vs. Ag/AgCl.
- 8 June 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (12) , 1300-1306
Amperometric Urea Biosensor Using Aminated Glassy Carbon Electrode Covered with Urease Immobilized Carbon Sheet, Based on the Electrode Oxidation of Carbamic Acid
A large oxidation current can be observed when ammonium carbamate aqueous solution is electrolyzed using a glassy carbon electrode (GCE) at a potential exceeding 1.0 V vs. Ag/AgCl and amino groups are introduced at the surface of the GCE. Aminated GCE exhibits the electrocatalytic activity of the oxidation of ammonium carbamate that is produced from urea as an intermediate product of urease reaction, and a distinct oxidation current is observed when the aminated GCE is used to oxidize the urea in the urease solution. A novel amperometric determination method to detect urea has been developed. This method is based on the electrooxidation of carbamic acid produced during urease reactions. Urease is immobilized to polymaleimidostyrene (PMS) coated on the insulated amorphous carbon sheet set on the aminated GCE surface. A good linear relationship is observed between urea concentration and the electrolytic current of the urease‐immobilized electrode in the concentration range from 0.5 mM to 21.0 mM. The proposed urea biosensor has an effective merit in that the interference resulting from ammonia and pH change caused by the urease reaction can be eliminated, differing from conventional urea biosensors.
- 8 June 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (12) , 1300-1306
Amperometric Urea Biosensor Using Aminated Glassy Carbon Electrode Covered with Urease Immobilized Carbon Sheet, Based on the Electrode Oxidation of Carbamic Acid
A large oxidation current can be observed when ammonium carbamate aqueous solution is electrolyzed using a glassy carbon electrode (GCE) at a potential exceeding 1.0 V vs. Ag/AgCl and amino groups are introduced at the surface of the GCE. Aminated GCE exhibits the electrocatalytic activity of the oxidation of ammonium carbamate that is produced from urea as an intermediate product of urease reaction, and a distinct oxidation current is observed when the aminated GCE is used to oxidize the urea in the urease solution. A novel amperometric determination method to detect urea has been developed. This method is based on the electrooxidation of carbamic acid produced during urease reactions. Urease is immobilized to polymaleimidostyrene (PMS) coated on the insulated amorphous carbon sheet set on the aminated GCE surface. A good linear relationship is observed between urea concentration and the electrolytic current of the urease‐immobilized electrode in the concentration range from 0.5 mM to 21.0 mM. The proposed urea biosensor has an effective merit in that the interference resulting from ammonia and pH change caused by the urease reaction can be eliminated, differing from conventional urea biosensors.
- 1 February 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (3) , 449-458
Long‐Term Stabilization of the Activity of Ascorbate Oxidase Adsorbed on a Porous Carbon Material by Polymaleimidostyrene
The biological catalysts adsorbed on the carbon surface gradually lost their activities. In order to prolong stabilization of the enzyme activity, polymaleimidostyrene (PMS) was used to preserve enzyme conformation. Sulfhydryl and amino groups of enzyme or biological tissue can be covalently bound to PMS. By using the carbon material coated by PMS, the stability of L‐ascorbic acid sensor response using purified enzyme was significantly improved, and its initial response was not decreased at all for 150 days, although the purified enzymes adsorbed to the carbon without PMS lost their activity 22.5% after 10 days.
- 1 February 2007
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (3) , 449-458
Long‐Term Stabilization of the Activity of Ascorbate Oxidase Adsorbed on a Porous Carbon Material by Polymaleimidostyrene
The biological catalysts adsorbed on the carbon surface gradually lost their activities. In order to prolong stabilization of the enzyme activity, polymaleimidostyrene (PMS) was used to preserve enzyme conformation. Sulfhydryl and amino groups of enzyme or biological tissue can be covalently bound to PMS. By using the carbon material coated by PMS, the stability of L‐ascorbic acid sensor response using purified enzyme was significantly improved, and its initial response was not decreased at all for 150 days, although the purified enzymes adsorbed to the carbon without PMS lost their activity 22.5% after 10 days.
- 31 May 2006
- Published by Elsevier in Bioelectrochemistry
- Vol. 68 (2) , 119-125
Application of polymaleimidostyrene as a convenient immobilization reagent of enzyme in biosensor
- 31 May 2006
- Published by Elsevier in Bioelectrochemistry
- Vol. 68 (2) , 119-125
Application of polymaleimidostyrene as a convenient immobilization reagent of enzyme in biosensor
- 22 November 2005
- Published by Wiley in Electroanalysis
- Vol. 17 (22) , 2052-2056
Estimation of Coupling Rate Constant ofL-Cysteine Radical Studied by Concentration-Step Coulometry Using Porous Carbon Felt Electrode Impregnated with an Electrolyte
- 22 November 2005
- Published by Wiley in Electroanalysis
- Vol. 17 (22) , 2052-2056
Estimation of Coupling Rate Constant ofL-Cysteine Radical Studied by Concentration-Step Coulometry Using Porous Carbon Felt Electrode Impregnated with an Electrolyte
- 1 January 2005
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 54 (12) , 1197-1204
FIA of NADH Using Flow-Through Electrochemical Detector with Thionine-Adsorbed Carbon Felt
- 1 January 2005
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 54 (12) , 1197-1204
FIA of NADH Using Flow-Through Electrochemical Detector with Thionine-Adsorbed Carbon Felt