Yasushi Hasebe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yasushi Hasebe has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Yue Wang
School of Chemical Engineering, University of Science and Technology Liaoning, Anshan, China
10 shared publications Yue Wang
University of Science and Technology Liaoning
8 shared publications- Shunichi Uchiyama
Department of Applied Chemistry, Faculty of Engineering, Saitama Institute of Technology, 1690 Fusaiji, Okabe, Saitama 369‐0293, Japan
5 shared publications Shunichi Uchiyama
Department of Applied Chemistry, Faculty of Engineering, Saitama Institute of Technology
4 shared publicationsZeting Jiao
Department of Life Science and Green Chemistry, Graduate School of Engineering, Saitama Institute of Technology, 1690 Fukaya, Saitama 369-0293, Japan
3 shared publications- Zhiqiang Zhang
School of Chemical Engineering, University of Science and Technology Liaoning, Anshan, 114051, P.R. China
3 shared publications
Latest Publications
- 16 January 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 13 (12) , 6289-6301
Electrodeposited Ni on a silk-derived carbon modified glassy carbon electrode for non-invasive sensing of glucose in saliva
In order to improve the life quality of diabetic patients, a groundbreaking study has designed a non-invasive sensor capable of monitoring glucose levels in saliva. The non-enzymatic glucose sensor constructed through electrodeposition of Ni represents an innovative electrochemical sensor aimed at enhancing the sensitivity and stability of glucose detection, while addressing the limitations of enzyme activity in traditional enzymatic sensors. This sensor is realized by loading a layer of nickel (Ni) electrodeposited on silk-derived carbon on the electrode surface. Nickel, as a catalyst, can directly catalyze the oxidation of glucose, generating a current signal proportional to the glucose concentration. In this non-enzymatic detection system, electrodeposition technology allows precise control over the structure of the nickel layer, optimizing its electrochemical activity and stability. Such nickel-based electrodes exhibit excellent catalytic efficiency and reusability, which is crucial for the development of reliable blood glucose monitoring devices. The non-enzymatic glucose sensor demonstrates an outstanding sensitivity of 484.22 μA mM−1 cm−2, a wide linear range of 1–1498 μM (1st linear range), and a low detection limit of 0.16 μM (S/N = 3). Furthermore, it shows excellent selectivity, stability, and fast response time for glucose. Importantly, the developed non-enzymatic glucose sensor can detect glucose levels in human saliva without any pretreatment, showing great potential for application in non-invasive sensors. By adjusting the electrodeposition parameters, such as deposition voltage, time, and nickel salt concentration, the surface morphology and structure of the nickel film can be further tuned to meet various detection requirements. The prepared sensor has great potential for application in clinical and personal health monitoring.
- 16 January 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 13 (12) , 6289-6301
Electrodeposited Ni on a silk-derived carbon modified glassy carbon electrode for non-invasive sensing of glucose in saliva
In order to improve the life quality of diabetic patients, a groundbreaking study has designed a non-invasive sensor capable of monitoring glucose levels in saliva. The non-enzymatic glucose sensor constructed through electrodeposition of Ni represents an innovative electrochemical sensor aimed at enhancing the sensitivity and stability of glucose detection, while addressing the limitations of enzyme activity in traditional enzymatic sensors. This sensor is realized by loading a layer of nickel (Ni) electrodeposited on silk-derived carbon on the electrode surface. Nickel, as a catalyst, can directly catalyze the oxidation of glucose, generating a current signal proportional to the glucose concentration. In this non-enzymatic detection system, electrodeposition technology allows precise control over the structure of the nickel layer, optimizing its electrochemical activity and stability. Such nickel-based electrodes exhibit excellent catalytic efficiency and reusability, which is crucial for the development of reliable blood glucose monitoring devices. The non-enzymatic glucose sensor demonstrates an outstanding sensitivity of 484.22 μA mM−1 cm−2, a wide linear range of 1–1498 μM (1st linear range), and a low detection limit of 0.16 μM (S/N = 3). Furthermore, it shows excellent selectivity, stability, and fast response time for glucose. Importantly, the developed non-enzymatic glucose sensor can detect glucose levels in human saliva without any pretreatment, showing great potential for application in non-invasive sensors. By adjusting the electrodeposition parameters, such as deposition voltage, time, and nickel salt concentration, the surface morphology and structure of the nickel film can be further tuned to meet various detection requirements. The prepared sensor has great potential for application in clinical and personal health monitoring.
- 9 December 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (4) , 714-723
An electrochemical sensor based on electrodeposited methylene blue on a carbon nanotube decorated hydrogel for the detection of ascorbic acid
An ascorbic acid electrochemical sensor is fabricated by combining a hydrogel and electrodeposited MB membrane. The sensor exhibits good linear range, fast response time and shows satisfactory results in the detection of AA in vitamin C tablets.
- 9 December 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (4) , 714-723
An electrochemical sensor based on electrodeposited methylene blue on a carbon nanotube decorated hydrogel for the detection of ascorbic acid
An ascorbic acid electrochemical sensor is fabricated by combining a hydrogel and electrodeposited MB membrane. The sensor exhibits good linear range, fast response time and shows satisfactory results in the detection of AA in vitamin C tablets.
- 6 December 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 163, 108882
Highly stretchable, adhesive and conductive hydrogel for flexible and stable bioelectrocatalytic sensing layer of enzyme-based amperometric glucose biosensor
- 6 December 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 163, 108882
Highly stretchable, adhesive and conductive hydrogel for flexible and stable bioelectrocatalytic sensing layer of enzyme-based amperometric glucose biosensor
- 29 October 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (44) , 18646-18650
Binding interaction of cationic acridine dyes with glucose oxidase to enhance mediated bioelectrocatalysis
Cationic acridine dyes enhanced mediated bioelectrocatalysis of glucose oxidase, and their binding interactions were analyzed using fluorescence quenching and docking simulation.
- 29 October 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (44) , 18646-18650
Binding interaction of cationic acridine dyes with glucose oxidase to enhance mediated bioelectrocatalysis
Cationic acridine dyes enhanced mediated bioelectrocatalysis of glucose oxidase, and their binding interactions were analyzed using fluorescence quenching and docking simulation.
- 19 August 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (34) , 5883-5895
Glucose oxidase, horseradish peroxidase and phenothiazine dyes-co-adsorbed carbon felt-based amperometric flow-biosensor for glucose
Based on the stabilizing effect of methylene blue toward glucose oxidase (GOx), amperometric flow-biosensor for glucose was developed by the combination of GOx-adsorbed carbon felt (CF)-reactor and peroxidase-adsorbed CF-based H2O2 detector.
- 19 August 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (34) , 5883-5895
Glucose oxidase, horseradish peroxidase and phenothiazine dyes-co-adsorbed carbon felt-based amperometric flow-biosensor for glucose
Based on the stabilizing effect of methylene blue toward glucose oxidase (GOx), amperometric flow-biosensor for glucose was developed by the combination of GOx-adsorbed carbon felt (CF)-reactor and peroxidase-adsorbed CF-based H2O2 detector.
- 24 March 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (13) , 4676-4691
Shield, Anchor, and Adhesive Roles of Methylene Blue in Tyrosinase Adsorbed on Carbon Felt for a Flow Injection Amperometric Enzyme Biosensor for Phenolic Substrates and Inhibitors
Methylene blue (MB) acted as a stabilizer for preventing surface-induced denaturation of tyrosinase (TYR) adsorbed on a carbon felt (CF) surface, which is based on shield and anchor roles preventing the unfavorable conformational change of TYR on the hydrophobic CF surface. Furthermore, MB acted as an effective adhesive for TYR immobilization on CF. The resulting TYR and MB coadsorbed CF (TYR/MB-CF) worked as an excellent working electrode unit in an electrochemical detector in a flow injection amperometric biosensor, which allowed highly sensitive consecutive determination of not only TYR substrates but also competitive inhibitors. Simultaneous adsorption of TYR and MB from their mixed solution was much useful as compared with step-wise separated adsorption of TYR on the MB-adsorbed CF, which suggests that the binding interaction of MB with TYR in the solution phase is important for this phenomenon. Fluorescence and UV-vis spectroscopy revealed that not only electrostatic forces between the cationic MB and anionic amino acid residues of TYR but also hydrophobic interactions via the phenothiazine ring of MB play a principal binding driving force of MB with TYR at the surface of the TYR molecules. Synchronous fluorescence, three-dimensional fluorescence, and circular dichroism (CD) spectroscopy clarified that the conformation and the secondary structure of TYR slightly changed upon the MB binding, implying that MB binding leads to the modification of the original intramolecular bonding in part.
- 24 March 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (13) , 4676-4691
Shield, Anchor, and Adhesive Roles of Methylene Blue in Tyrosinase Adsorbed on Carbon Felt for a Flow Injection Amperometric Enzyme Biosensor for Phenolic Substrates and Inhibitors
Methylene blue (MB) acted as a stabilizer for preventing surface-induced denaturation of tyrosinase (TYR) adsorbed on a carbon felt (CF) surface, which is based on shield and anchor roles preventing the unfavorable conformational change of TYR on the hydrophobic CF surface. Furthermore, MB acted as an effective adhesive for TYR immobilization on CF. The resulting TYR and MB coadsorbed CF (TYR/MB-CF) worked as an excellent working electrode unit in an electrochemical detector in a flow injection amperometric biosensor, which allowed highly sensitive consecutive determination of not only TYR substrates but also competitive inhibitors. Simultaneous adsorption of TYR and MB from their mixed solution was much useful as compared with step-wise separated adsorption of TYR on the MB-adsorbed CF, which suggests that the binding interaction of MB with TYR in the solution phase is important for this phenomenon. Fluorescence and UV-vis spectroscopy revealed that not only electrostatic forces between the cationic MB and anionic amino acid residues of TYR but also hydrophobic interactions via the phenothiazine ring of MB play a principal binding driving force of MB with TYR at the surface of the TYR molecules. Synchronous fluorescence, three-dimensional fluorescence, and circular dichroism (CD) spectroscopy clarified that the conformation and the secondary structure of TYR slightly changed upon the MB binding, implying that MB binding leads to the modification of the original intramolecular bonding in part.
- Open Access
- 18 May 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6 (21) , 13719-13727
Natural Molybdenite- and Tyrosinase-Based Amperometric Catechol Biosensor Using Acridine Orange as a Glue, Anchor, and Stabilizer for the Adsorbed Tyrosinase
- 18 May 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6 (21) , 13719-13727
Open AccessNatural Molybdenite- and Tyrosinase-Based Amperometric Catechol Biosensor Using Acridine Orange as a Glue, Anchor, and Stabilizer for the Adsorbed Tyrosinase
- Open Access
- 11 April 2019
- Published by MYU K.K. in Sensors and Materials
- Vol. 31 (4) , 1191-1203
Carbon-black-doped Polyimide-modified Glassy Carbon Electrode for Sensitive Nonenzymatic Amperometric Determination of Hydrogen Peroxide
- 11 April 2019
- Published by MYU K.K. in Sensors and Materials
- Vol. 31 (4) , 1191-1203
Open AccessCarbon-black-doped Polyimide-modified Glassy Carbon Electrode for Sensitive Nonenzymatic Amperometric Determination of Hydrogen Peroxide
- Open Access
- 11 April 2019
- Published by MYU K.K. in Sensors and Materials
- Vol. 31 (4) , 1181-1190
Phenazine-dye- and Enzyme-modified Plastic Formed Carbon Electrode for Amperometric Dihydronicotinamide Adenine Dinucleotide and Glucose Sensing
- 11 April 2019
- Published by MYU K.K. in Sensors and Materials
- Vol. 31 (4) , 1181-1190
Open AccessPhenazine-dye- and Enzyme-modified Plastic Formed Carbon Electrode for Amperometric Dihydronicotinamide Adenine Dinucleotide and Glucose Sensing
- Open Access
Carbon Black-Carbon Nanotube Co-Doped Polyimide Sensors for Simultaneous Determination of Ascorbic Acid, Uric Acid, and Dopamine
Carbon black (CB) and carbon nanotube (CNT) co-doped polyimide (PI) modified glassy carbon electrode (CB-CNT/PI/GCE) was first prepared for the simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The CB-CNT/PI/GCE exhibited persistent electrochemical behavior and excellent catalytic activities. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used for the simultaneous detection of AA, DA, and UA in their ternary mixture. The peak separations between AA and DA, and DA and UA, are up to 166 mV and 148 mV, respectively. The CB-CNT/PI/GCE exhibited high sensitivity to DA and UA, with the detection limit of 1.9 µM and 3 µM, respectively. In addition, the CB-CNT/PI/GCE showed sufficient selectivity and long-term stability, and was applicable to detect AA, DA, and UA in human urine sample.
Open AccessCarbon Black-Carbon Nanotube Co-Doped Polyimide Sensors for Simultaneous Determination of Ascorbic Acid, Uric Acid, and Dopamine
Carbon black (CB) and carbon nanotube (CNT) co-doped polyimide (PI) modified glassy carbon electrode (CB-CNT/PI/GCE) was first prepared for the simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The CB-CNT/PI/GCE exhibited persistent electrochemical behavior and excellent catalytic activities. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used for the simultaneous detection of AA, DA, and UA in their ternary mixture. The peak separations between AA and DA, and DA and UA, are up to 166 mV and 148 mV, respectively. The CB-CNT/PI/GCE exhibited high sensitivity to DA and UA, with the detection limit of 1.9 µM and 3 µM, respectively. In addition, the CB-CNT/PI/GCE showed sufficient selectivity and long-term stability, and was applicable to detect AA, DA, and UA in human urine sample.