Tony Wilson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tony Wilson has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Mark A. A. Neil
Imperial College London
8 shared publications M. J. Booth
Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, U.K.
5 shared publicationsMartin J. Booth
Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, United Kingdom
5 shared publicationsEdward J. Botcherby
Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, United Kingdom
4 shared publicationsR. Juškaitis
Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK
4 shared publicationsRimas Juškaitis
Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, United Kingdom
4 shared publications
Latest Publications
- 6 February 2012
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 109 (8) , 2919-2924
Aberration-free three-dimensional multiphoton imaging of neuronal activity at kHz rates
Multiphoton microscopy is a powerful tool in neuroscience, promising to deliver important data on the spatiotemporal activity within individual neurons as well as in networks of neurons. A major limitation of current technologies is the relatively slow scan rates along the z direction compared to the kHz rates obtainable in the x and y directions. Here, we describe a custom-built microscope system based on an architecture that allows kHz scan rates over hundreds of microns in all three dimensions without introducing aberration. We further demonstrate how this high-speed 3D multiphoton imaging system can be used to study neuronal activity at millisecond resolution at the subcellular as well as the population level.
- 6 February 2012
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 109 (8) , 2919-2924
Aberration-free three-dimensional multiphoton imaging of neuronal activity at kHz rates
Multiphoton microscopy is a powerful tool in neuroscience, promising to deliver important data on the spatiotemporal activity within individual neurons as well as in networks of neurons. A major limitation of current technologies is the relatively slow scan rates along the z direction compared to the kHz rates obtainable in the x and y directions. Here, we describe a custom-built microscope system based on an architecture that allows kHz scan rates over hundreds of microns in all three dimensions without introducing aberration. We further demonstrate how this high-speed 3D multiphoton imaging system can be used to study neuronal activity at millisecond resolution at the subcellular as well as the population level.
- Top Cited Papers
- 17 October 2011
- Published by Wiley in Journal of Microscopy
- Vol. 244 (2) , 113-121
Resolution and optical sectioning in the confocal microscope
In this short review, we present a self-contained discussion of the image formation properties of the fluorescent confocal microscope. The optical sectioning or depth discrimination property is discussed in detail and new analytic formulae are presented, which relate the optical sectioning strength to the wavelength, numerical aperture and pinhole aperture size in a particularly simple fashion.
- 17 October 2011
- Published by Wiley in Journal of Microscopy
- Vol. 244 (2) , 113-121
Top Cited PapersResolution and optical sectioning in the confocal microscope
In this short review, we present a self-contained discussion of the image formation properties of the fluorescent confocal microscope. The optical sectioning or depth discrimination property is discussed in detail and new analytic formulae are presented, which relate the optical sectioning strength to the wavelength, numerical aperture and pinhole aperture size in a particularly simple fashion.
- 23 February 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (5) , 663-665
Agitation-free multiphoton microscopy of oblique planes
The scanning two-photon fluorescence microscope produces optically sectioned images from the focal plane. It is sometimes desirable to acquire images from other planes of the specimen that are inclined with respect to the focal plane. In this Letter, we discuss the issues concerned with acquiring such images together with the effects of the inclination angle on image resolution and sectioning strength. To obtain images from oblique planes at high speed, a two-photon system was built wherein a novel optical system is used to provide aberration-free scanning.
- 23 February 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (5) , 663-665
Agitation-free multiphoton microscopy of oblique planes
The scanning two-photon fluorescence microscope produces optically sectioned images from the focal plane. It is sometimes desirable to acquire images from other planes of the specimen that are inclined with respect to the focal plane. In this Letter, we discuss the issues concerned with acquiring such images together with the effects of the inclination angle on image resolution and sectioning strength. To obtain images from oblique planes at high speed, a two-photon system was built wherein a novel optical system is used to provide aberration-free scanning.
- 27 January 2011
- Published by Optica Publishing Group in Optics Express
- Vol. 19 (3) , 2662-2669
Resolution of oblique-plane images in sectioning microscopy
Live biological specimens exhibit time-varying behavior on the microscale in all three dimensions. Although scanning confocal and two-photon microscopes are able to record three-dimensional image stacks through these specimens, they do so at relatively low speeds which limits the time resolution of the biological processes that can be observed. One way to improve the data acquisition rate is to image only the regions of a specimen that are of interest and so researchers have recently begun to acquire two-dimensional images of inclined planes or surfaces extending significantly into the z-direction. As the resolution is not uniform in x, y and z, the images possess non-isotropic resolution. We explore this theoretically and show that images of an oblique plane may contain spectral content that could not have been generated by specimen features lying wholly within the plane but must instead arise from a spatial variation in another direction. In some cases we find that the image contains frequencies three times higher than the resolution limit for in-plane features. We confirm this finding through numerical simulations and experiments on a novel, oblique-plane imaging system and suggest that care be taken in the interpretation of such images.
- 27 January 2011
- Published by Optica Publishing Group in Optics Express
- Vol. 19 (3) , 2662-2669
Resolution of oblique-plane images in sectioning microscopy
Live biological specimens exhibit time-varying behavior on the microscale in all three dimensions. Although scanning confocal and two-photon microscopes are able to record three-dimensional image stacks through these specimens, they do so at relatively low speeds which limits the time resolution of the biological processes that can be observed. One way to improve the data acquisition rate is to image only the regions of a specimen that are of interest and so researchers have recently begun to acquire two-dimensional images of inclined planes or surfaces extending significantly into the z-direction. As the resolution is not uniform in x, y and z, the images possess non-isotropic resolution. We explore this theoretically and show that images of an oblique plane may contain spectral content that could not have been generated by specimen features lying wholly within the plane but must instead arise from a spatial variation in another direction. In some cases we find that the image contains frequencies three times higher than the resolution limit for in-plane features. We confirm this finding through numerical simulations and experiments on a novel, oblique-plane imaging system and suggest that care be taken in the interpretation of such images.
- 22 November 2010
- Published by Wiley in Journal of Microscopy
- Vol. 242 (2) , 111-116
Optical sectioning in fluorescence microscopy
We review the origins of optical sectioning in fluorescence microscopy in terms of the structure of the illumination used to generate the fluorescence within the specimen. We note that the conventional microscope using essentially uniform illumination does not exhibit optical sectioning whereas the confocal microscope using point (many spatial frequencies) illumination does. We show that the optical sectioning strength of a confocal microscope is not optimal and discuss the advantages of using a single spatial frequency for the structure of the illumination and the detection. In this case the optical sectioning strength is shown to be up to 25% narrower than in the ideal confocal case.
- 22 November 2010
- Published by Wiley in Journal of Microscopy
- Vol. 242 (2) , 111-116
Optical sectioning in fluorescence microscopy
We review the origins of optical sectioning in fluorescence microscopy in terms of the structure of the illumination used to generate the fluorescence within the specimen. We note that the conventional microscope using essentially uniform illumination does not exhibit optical sectioning whereas the confocal microscope using point (many spatial frequencies) illumination does. We show that the optical sectioning strength of a confocal microscope is not optimal and discuss the advantages of using a single spatial frequency for the structure of the illumination and the detection. In this case the optical sectioning strength is shown to be up to 25% narrower than in the ideal confocal case.
- Open Access
- 3 June 2010
- Published by Springer Nature in BMC Cell Biology
- Vol. 11 (1) , 38
Characterisation of the dynamic behaviour of lipid droplets in the early mouse embryo using adaptive harmonic generation microscopy
Background: Lipid droplets (LD) are organelles with an important role in normal metabolism and disease. The lipid content of embryos has a major impact on viability and development. LD in Drosophila embryos and cultured cell lines have been shown to move and fuse in a microtubule dependent manner. Due to limitations in current imaging technology, little is known about the behaviour of LD in the mammalian embryo. Harmonic generation microscopy (HGM) allows one to image LD without the use of exogenous labels. Adaptive optics can be used to correct aberrations that would otherwise degrade the quality and information content of images. Results: We have built a harmonic generation microscope with adaptive optics to characterise early mouse embryogenesis. At fertilization, LD are small and uniformly distributed, but in the implanting blastocyst, LD are larger and enriched in the invading giant cells of the trophectoderm. Time-lapse studies reveal that LD move continuously and collide but do not fuse, instead forming aggregates that subsequently behave as single units. Using specific inhibitors, we show that the velocity and dynamic behaviour of LD is dependent not only on microtubules as in other systems, but also on microfilaments. We explore the limits within which HGM can be used to study living embryos without compromising viability and make the counterintuitive finding that 16 J of energy delivered continuously over a period of minutes can be less deleterious than an order of magnitude lower energy delivered dis-continuously over a period of hours. Conclusions: LD in pre-implantation mouse embryos show a previously unappreciated complexity of behaviour that is dependent not only on microtubules, but also microfilaments. Unlike LD in other systems, LD in the mouse embryo do not fuse but form aggregates. This study establishes HGM with adaptive optics as a powerful tool for the study of LD biology and provides insights into the photo-toxic effects of imaging embryos.
- 3 June 2010
- Published by Springer Nature in BMC Cell Biology
- Vol. 11 (1) , 38
Open AccessCharacterisation of the dynamic behaviour of lipid droplets in the early mouse embryo using adaptive harmonic generation microscopy
Background: Lipid droplets (LD) are organelles with an important role in normal metabolism and disease. The lipid content of embryos has a major impact on viability and development. LD in Drosophila embryos and cultured cell lines have been shown to move and fuse in a microtubule dependent manner. Due to limitations in current imaging technology, little is known about the behaviour of LD in the mammalian embryo. Harmonic generation microscopy (HGM) allows one to image LD without the use of exogenous labels. Adaptive optics can be used to correct aberrations that would otherwise degrade the quality and information content of images. Results: We have built a harmonic generation microscope with adaptive optics to characterise early mouse embryogenesis. At fertilization, LD are small and uniformly distributed, but in the implanting blastocyst, LD are larger and enriched in the invading giant cells of the trophectoderm. Time-lapse studies reveal that LD move continuously and collide but do not fuse, instead forming aggregates that subsequently behave as single units. Using specific inhibitors, we show that the velocity and dynamic behaviour of LD is dependent not only on microtubules as in other systems, but also on microfilaments. We explore the limits within which HGM can be used to study living embryos without compromising viability and make the counterintuitive finding that 16 J of energy delivered continuously over a period of minutes can be less deleterious than an order of magnitude lower energy delivered dis-continuously over a period of hours. Conclusions: LD in pre-implantation mouse embryos show a previously unappreciated complexity of behaviour that is dependent not only on microtubules, but also microfilaments. Unlike LD in other systems, LD in the mouse embryo do not fuse but form aggregates. This study establishes HGM with adaptive optics as a powerful tool for the study of LD biology and provides insights into the photo-toxic effects of imaging embryos.
- 4 May 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (10) , 1504-1506
Real-time slit scanning microscopy in the meridional plane
The standard microscope architecture around which confocal microscopes are built imposes fundamental restrictions on the speed with which images (three-dimensional data sets) can be obtained. Commercially available slit scanning confocal microscopes are able to produce optically sectioned images at frame rates well in excess of 100 Hz. However only the focal plane can be imaged at this speed. To image a volume specimen it is necessary to physically change the distance between the objective lens and the specimen. This refocusing process is often necessarily slow and represents a bottleneck to the speed of image acquisition. We describe the construction of a slit scanning confocal microscope based on what we know to be a novel microscope architecture, which permits images of other planes and, particular, the meridional plane to be acquired in real time.- 4 May 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (10) , 1504-1506
Real-time slit scanning microscopy in the meridional plane
The standard microscope architecture around which confocal microscopes are built imposes fundamental restrictions on the speed with which images (three-dimensional data sets) can be obtained. Commercially available slit scanning confocal microscopes are able to produce optically sectioned images at frame rates well in excess of 100 Hz. However only the focal plane can be imaged at this speed. To image a volume specimen it is necessary to physically change the distance between the objective lens and the specimen. This refocusing process is often necessarily slow and represents a bottleneck to the speed of image acquisition. We describe the construction of a slit scanning confocal microscope based on what we know to be a novel microscope architecture, which permits images of other planes and, particular, the meridional plane to be acquired in real time.- 1 October 2007
- Published by Wiley in Journal of Microscopy
- Vol. 228 (1) , 97-102
Specimen‐induced distortions in light microscopy
Summary: Specimen‐induced aberrations affect the imaging properties in optical 3D microscopy, especially when high numerical aperture lenses are used. Studies on aberrations are often properly concerned with the degradation of image quality such as compromised resolution or reduced signal intensity. Apart from these, aberration effects can also introduce geometric image distortions. The effects, discussed here are particularly strong when thick biological specimens are investigated. Using a high numerical aperture interferometer, we measured wavefront aberrations in transmission mode and quantified geometric distortions associated with specimen‐induced aberrations. This assessment for a range of biological specimens allows estimation of the accuracy of spatial measurements. The results show that high‐resolution spatial measurements can be significantly compromised by specimen‐induced aberrations.
- 1 October 2007
- Published by Wiley in Journal of Microscopy
- Vol. 228 (1) , 97-102
Specimen‐induced distortions in light microscopy
Summary: Specimen‐induced aberrations affect the imaging properties in optical 3D microscopy, especially when high numerical aperture lenses are used. Studies on aberrations are often properly concerned with the degradation of image quality such as compromised resolution or reduced signal intensity. Apart from these, aberration effects can also introduce geometric image distortions. The effects, discussed here are particularly strong when thick biological specimens are investigated. Using a high numerical aperture interferometer, we measured wavefront aberrations in transmission mode and quantified geometric distortions associated with specimen‐induced aberrations. This assessment for a range of biological specimens allows estimation of the accuracy of spatial measurements. The results show that high‐resolution spatial measurements can be significantly compromised by specimen‐induced aberrations.
- 3 July 2007
- Published by Optica Publishing Group in Optics Letters
- Vol. 32 (14) , 2007-2009
Aberration-free optical refocusing in high numerical aperture microscopy
We describe a method of optical refocusing for high numerical aperture (NA) systems that is particularly relevant for confocal and multiphoton microscopy. This method avoids the spherical aberration that is common to other optical refocusing systems. We show that aberration-free images can be obtained over an axial scan range of for a 1.4 NA objective lens. As refocusing is implemented remotely from the specimen, this method will enable high axial scan speeds without mechanical interference between the objective lens and the specimen.- 3 July 2007
- Published by Optica Publishing Group in Optics Letters
- Vol. 32 (14) , 2007-2009
Aberration-free optical refocusing in high numerical aperture microscopy
We describe a method of optical refocusing for high numerical aperture (NA) systems that is particularly relevant for confocal and multiphoton microscopy. This method avoids the spherical aberration that is common to other optical refocusing systems. We show that aberration-free images can be obtained over an axial scan range of for a 1.4 NA objective lens. As refocusing is implemented remotely from the specimen, this method will enable high axial scan speeds without mechanical interference between the objective lens and the specimen.- 22 February 2005
- Published by Wiley in Journal of Microscopy
- Vol. 217 (3) , 184-187
Simple optimization procedure for objective lens correction collar setting
Summary: We present a new method for setting a coverglass correction collar on an objective lens. Axial scans across the interface between the specimen volume and the slide are used together with a quantitative function of merit to determine the optimum setting of the correction collar. The method, which simplifies the adjustment for the user and reduces photobleaching, was implemented within the software environment of a scanning microscope system.
- 22 February 2005
- Published by Wiley in Journal of Microscopy
- Vol. 217 (3) , 184-187
Simple optimization procedure for objective lens correction collar setting
Summary: We present a new method for setting a coverglass correction collar on an objective lens. Axial scans across the interface between the specimen volume and the slide are used together with a quantitative function of merit to determine the optimum setting of the correction collar. The method, which simplifies the adjustment for the user and reduces photobleaching, was implemented within the software environment of a scanning microscope system.