John W. van de Lindt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
John W. van de Lindt has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Shiling Pei
Assistant Professor, Dept. of Civil and Environmental Engineering, South Dakota State Univ., Brookings, SD 57007
4 shared publications Hongyan Liu
Formerly, Doctoral Candidate, Civil Engineering, Colorado State Univ
3 shared publicationsRakesh Gupta
Department of Wood Science and Engineering, Oregon State University, Corvallis, USA
2 shared publicationsShiling Pei
Professor and Garry Neil Drummond Endowed Chair, Dept. of Civil, Construction, and Environmental Engineering, Univ. of Alabama, Tuscaloosa, AL
2 shared publications- Thang N. Dao
Doctoral Candidate, Dept. of Civil and Environmental Engineering, Colorado State Univ., Campus Delivery 1372, Fort Collins, CO 80523-1372.
2 shared publications Alex Stone
Professor and Drummond Chair in Civil Engineering, Dept. of Civil, Construction, and Environmental Engineering, Univ. of Alabama, Box 870205, Tuscaloosa, AL 35487–0205; formerly, Associate Professor, Dept. of Civil and Environmental Engineering, Colorado State Univ., Fort Collins, CO 80523-1372
1 shared publication
Latest Publications
- 1 June 2017
- Published by Elsevier in Engineering Structures
- Vol. 140, 98-109
New nonlinear lateral-vertical coupled shear element model for use in finite element structural analysis applications
- 1 June 2017
- Published by Elsevier in Engineering Structures
- Vol. 140, 98-109
New nonlinear lateral-vertical coupled shear element model for use in finite element structural analysis applications
- 15 November 2013
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 18 (3) , 389-406
Variability in Wood-Frame Building Damage using Broad-Band Synthetic Ground Motions: A Comparative Numerical Study with Recorded Motions
Earthquake damage to light-frame wood buildings is a major concern for North America because of the volume of this construction type. In order to estimate wood building damage using synthetic ground motions, we need to verify the ability of synthetically generated ground motions to simulate realistic damage for this structure type. Through a calibrated damage potential indicator, four different synthetic ground motion models are compared with the historically recorded ground motions at corresponding sites. We conclude that damage for sites farther from the fault (>20 km) is under-predicted on average and damage at closer sites is sometimes over-predicted.
- 15 November 2013
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 18 (3) , 389-406
Variability in Wood-Frame Building Damage using Broad-Band Synthetic Ground Motions: A Comparative Numerical Study with Recorded Motions
Earthquake damage to light-frame wood buildings is a major concern for North America because of the volume of this construction type. In order to estimate wood building damage using synthetic ground motions, we need to verify the ability of synthetically generated ground motions to simulate realistic damage for this structure type. Through a calibrated damage potential indicator, four different synthetic ground motion models are compared with the historically recorded ground motions at corresponding sites. We conclude that damage for sites farther from the fault (>20 km) is under-predicted on average and damage at closer sites is sometimes over-predicted.
- 1 June 2013
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- Vol. 9 (6) , 594-600
Reliability-based design of medium mast lighting structural supports
Rural intersections and interchanges often require lighting for driver safety. Although high mast lighting supports, sometimes as tall as 50 m have been installed in many locations, it is becoming apparent that light pollution to nearby residences is an issue. As a response to this problem, the Colorado Department of Transportation is moving towards the use of medium mast lights which are typically 15–20 m in height. This article presents the results of a numerical investigation to develop reliability-based design charts as a function of several key design variables and the mean wind velocity at a site. These medium-mast structures are less than 1 m in diameter at the base and are quite flexible relative to many civil engineering structures. The limit state function is formulated in terms of fatigue life and is computed based on the moments at the base that are produced during multi-mode dynamic excitation as a result of the wind loading. Morison's equation, which provides relative force for slender bodies as a function of flow velocity, was applied within a dynamic finite element framework in order to account for the relative motion between the wind and the motion of the structure. Then, a well-known random vibrations approach was coupled with Miner's rule to estimate the fatigue life of the structural support. Reliability-based design charts for several different design variables such as wall thickness and outside diameter are presented.
- 1 June 2013
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- Vol. 9 (6) , 594-600
Reliability-based design of medium mast lighting structural supports
Rural intersections and interchanges often require lighting for driver safety. Although high mast lighting supports, sometimes as tall as 50 m have been installed in many locations, it is becoming apparent that light pollution to nearby residences is an issue. As a response to this problem, the Colorado Department of Transportation is moving towards the use of medium mast lights which are typically 15–20 m in height. This article presents the results of a numerical investigation to develop reliability-based design charts as a function of several key design variables and the mean wind velocity at a site. These medium-mast structures are less than 1 m in diameter at the base and are quite flexible relative to many civil engineering structures. The limit state function is formulated in terms of fatigue life and is computed based on the moments at the base that are produced during multi-mode dynamic excitation as a result of the wind loading. Morison's equation, which provides relative force for slender bodies as a function of flow velocity, was applied within a dynamic finite element framework in order to account for the relative motion between the wind and the motion of the structure. Then, a well-known random vibrations approach was coupled with Miner's rule to estimate the fatigue life of the structural support. Reliability-based design charts for several different design variables such as wall thickness and outside diameter are presented.
- 17 May 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 2170-2179
GIS for the Geo-Referenced Analysis and Rapid Dissemination of Forensic Evidence Collected in the Aftermath of the Tuscaloosa Tornado
This study investigates the utilization of Geographic Information System (GIS) technology to rapidly disseminate damage and failure mode data related to wood-frame construction collected in the aftermath of the Tuscaloosa tornado on April 27, 2011. The City of Tuscaloosa was in the direct path of a major super cell tornado that bisected the city in a south-west to north-east direction with a half mile wide destruction path. Immediately after the tornado, forensic data collection activities were conducted. Forensic evidence was collected through both active and passive modes. Active data collection occurred at specific case study sites and along transects that ran approximately perpendicular to the direction of the tornado path. Passive data collection modes captured forensic evidence as researchers moved throughout the affected area. Tracking both the time and the location of field activities set the basis for the fusion of the collected data. Thus, by using the time of data collection, forensic data was correlated to a geo-location in full-day GPS track logs and uploaded in a GIS web portal. The web portal enabled 1) the geo-referenced analyses of the collected data, and 2) the rapid dissemination of the forensic evidence to the scientific community and to anyone with an internet connection.
- 17 May 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 2170-2179
GIS for the Geo-Referenced Analysis and Rapid Dissemination of Forensic Evidence Collected in the Aftermath of the Tuscaloosa Tornado
This study investigates the utilization of Geographic Information System (GIS) technology to rapidly disseminate damage and failure mode data related to wood-frame construction collected in the aftermath of the Tuscaloosa tornado on April 27, 2011. The City of Tuscaloosa was in the direct path of a major super cell tornado that bisected the city in a south-west to north-east direction with a half mile wide destruction path. Immediately after the tornado, forensic data collection activities were conducted. Forensic evidence was collected through both active and passive modes. Active data collection occurred at specific case study sites and along transects that ran approximately perpendicular to the direction of the tornado path. Passive data collection modes captured forensic evidence as researchers moved throughout the affected area. Tracking both the time and the location of field activities set the basis for the fusion of the collected data. Thus, by using the time of data collection, forensic data was correlated to a geo-location in full-day GPS track logs and uploaded in a GIS web portal. The web portal enabled 1) the geo-referenced analyses of the collected data, and 2) the rapid dissemination of the forensic evidence to the scientific community and to anyone with an internet connection.
- 21 April 2012
- Published by Springer Nature in Natural Hazards
- Vol. 63 (2) , 891-908
Method to determine the locations of tsunami vertical evacuation shelters
- 21 April 2012
- Published by Springer Nature in Natural Hazards
- Vol. 63 (2) , 891-908
Method to determine the locations of tsunami vertical evacuation shelters
- 1 April 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 138 (4) , 492-501
Collapse Testing and Analysis of a Light-Frame Wood Garage Wall
Light-frame wood (woodframe) buildings have been tested at full-scale sparingly around the world, primarily due to the cost associated with such testing and a general lack of facilities large enough to test at system level. The data from the tests that have been performed are used to help develop nonlinear time history analysis models that can predict the behavior of woodframe buildings during strong ground shaking. It is difficult to test buildings to the point of collapse because such tests can damage costly test equipment, i.e., the shake table. This paper presents the results of a dynamic collapse test on a light-frame wood garage wall and the results of a numerical model to simulate the wall behavior all the way to the collapse point. The tested wall was heavily damaged as a result of subjecting it to a ground motion recorded during the 1995 Kobe earthquake. Then, 85% of a near-fault ground motion recording from the Northridge earthquake was used, which immediately collapsed the test specimen...
- 1 April 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 138 (4) , 492-501
Collapse Testing and Analysis of a Light-Frame Wood Garage Wall
Light-frame wood (woodframe) buildings have been tested at full-scale sparingly around the world, primarily due to the cost associated with such testing and a general lack of facilities large enough to test at system level. The data from the tests that have been performed are used to help develop nonlinear time history analysis models that can predict the behavior of woodframe buildings during strong ground shaking. It is difficult to test buildings to the point of collapse because such tests can damage costly test equipment, i.e., the shake table. This paper presents the results of a dynamic collapse test on a light-frame wood garage wall and the results of a numerical model to simulate the wall behavior all the way to the collapse point. The tested wall was heavily damaged as a result of subjecting it to a ground motion recorded during the 1995 Kobe earthquake. Then, 85% of a near-fault ground motion recording from the Northridge earthquake was used, which immediately collapsed the test specimen...
- 29 March 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 1778-1789
Collapse Limits for Wood Frame Shear Walls: An Experimental Investigation
Under extreme earthquake loading, light-frame wood building collapse is often caused by excessive inter-story drift at one or more story levels, which can lead to catastrophic P-Δ failure once the shear walls, and subsequently the entire structure, become unstable. Current performance-based seismic design for light-frame wood structures typically uses very conservative drift limits to prevent the collapse of the system, such as 3% drift in the ACSE Standard 41. The collapse drift limit for wood shear walls has not been studied extensively to date. A series of full scale collapse tests for wood shear walls was conducted and is presented in this paper with the objective of investigating the influence of wall configuration and gravity load on the ultimate drift level at which P-Δ collapse occurs. The shear wall collapse limit was found to be a function of wall strength and vertical load. Assigning a single ultimate drift level for light-frame wood building collapse limits appears to be justifiable based on the test results.
- 29 March 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 1778-1789
Collapse Limits for Wood Frame Shear Walls: An Experimental Investigation
Under extreme earthquake loading, light-frame wood building collapse is often caused by excessive inter-story drift at one or more story levels, which can lead to catastrophic P-Δ failure once the shear walls, and subsequently the entire structure, become unstable. Current performance-based seismic design for light-frame wood structures typically uses very conservative drift limits to prevent the collapse of the system, such as 3% drift in the ACSE Standard 41. The collapse drift limit for wood shear walls has not been studied extensively to date. A series of full scale collapse tests for wood shear walls was conducted and is presented in this paper with the objective of investigating the influence of wall configuration and gravity load on the ultimate drift level at which P-Δ collapse occurs. The shear wall collapse limit was found to be a function of wall strength and vertical load. Assigning a single ultimate drift level for light-frame wood building collapse limits appears to be justifiable based on the test results.
- 29 March 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 1755-1766
Numerical Modeling of Soft-Story Woodframe Retrofit Techniques for Design
Soft-story woodframe buildings are recognizable by their large openings at the bottom story which are typically for parking or other storage. During an earthquake, these large openings lead to large inter-story drifts and potential collapse, even before the upper stories experience any significant drifts. In order to improve the seismic performance of these at-risk buildings, a retrofit technique is designed using a Performance Base Seismic Retrofit (PBSR) method which applies the direct displacement design (DDD) approach. Torsion is eliminated based on structural analysis and then the DDD procedure is applied. The seismic performance of the retrofitted building is evaluated through multi-record incremental dynamic analysis (IDA). This paper focuses on the retrofit of a full-scale three-story wood-frame building that will be tested in 2012 at the NEES@Buffalo laboratory as part of the NEES-Soft Project. Two different types of retrofits models were developed, namely the inverted steel moment frames (IMF) and wood shearwalls resulting in the building achieving the prescribed performance objectives at all stories.
- 29 March 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 1755-1766
Numerical Modeling of Soft-Story Woodframe Retrofit Techniques for Design
Soft-story woodframe buildings are recognizable by their large openings at the bottom story which are typically for parking or other storage. During an earthquake, these large openings lead to large inter-story drifts and potential collapse, even before the upper stories experience any significant drifts. In order to improve the seismic performance of these at-risk buildings, a retrofit technique is designed using a Performance Base Seismic Retrofit (PBSR) method which applies the direct displacement design (DDD) approach. Torsion is eliminated based on structural analysis and then the DDD procedure is applied. The seismic performance of the retrofitted building is evaluated through multi-record incremental dynamic analysis (IDA). This paper focuses on the retrofit of a full-scale three-story wood-frame building that will be tested in 2012 at the NEES@Buffalo laboratory as part of the NEES-Soft Project. Two different types of retrofits models were developed, namely the inverted steel moment frames (IMF) and wood shearwalls resulting in the building achieving the prescribed performance objectives at all stories.
- 1 February 2012
- Published by American Society of Civil Engineers (ASCE) in Natural Hazards Review
- Vol. 13 (1) , 24-33
Effect of Plan Configuration on Seismic Performance of Single-Story Wood-Frame Dwellings
A numerical investigation is presented on effects of plan configuration on seismic responses of single-story, wood-frame dwellings. 151 models were developed using observations of 412 dwellings of rectangular, L, T, U, and Z-shapes in Oregon. A nonlinear, time-history program, Seismic Analysis Package for Wood-frame Structures, was the analysis platform. Models were analyzed for 10 pairs of biaxial ground motions (spectral accelerations from 0.1 g to 2.0 g) for Seattle. Configuration comparisons were made using median shear wall maximum drifts and occurrences of maximum drifts exceeding the 3% collapse prevention limit. Plan configuration significantly affects performance through building mass, lateral stiffnesses, and eccentricities. Irregular configuration tends to induce eccentricity and cause one wall to exceed the allowable drift limit, and fail, earlier than others. Square-like buildings usually perform better than long, thin rectangles. Classification of single-story dwellings based on shape parame...
- 1 February 2012
- Published by American Society of Civil Engineers (ASCE) in Natural Hazards Review
- Vol. 13 (1) , 24-33
Effect of Plan Configuration on Seismic Performance of Single-Story Wood-Frame Dwellings
A numerical investigation is presented on effects of plan configuration on seismic responses of single-story, wood-frame dwellings. 151 models were developed using observations of 412 dwellings of rectangular, L, T, U, and Z-shapes in Oregon. A nonlinear, time-history program, Seismic Analysis Package for Wood-frame Structures, was the analysis platform. Models were analyzed for 10 pairs of biaxial ground motions (spectral accelerations from 0.1 g to 2.0 g) for Seattle. Configuration comparisons were made using median shear wall maximum drifts and occurrences of maximum drifts exceeding the 3% collapse prevention limit. Plan configuration significantly affects performance through building mass, lateral stiffnesses, and eccentricities. Irregular configuration tends to induce eccentricity and cause one wall to exceed the allowable drift limit, and fail, earlier than others. Square-like buildings usually perform better than long, thin rectangles. Classification of single-story dwellings based on shape parame...
- 1 February 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 26 (1) , 17-25
Damage Assessment of a Full-Scale Six-Story Wood-Frame Building Following Triaxial Shake Table Tests
In the summer of 2009, a full-scale midrise wood-frame building was tested under a series of simulated earthquakes on the world’s largest shake table in Miki City, Japan. The objective of this series of tests was to validate a performance-based seismic design approach by qualitatively and quantitatively examining the building’s seismic performance in terms of response kinematics and observed damage. This paper presents the results of detailed damage inspections following each test in a series of five shake table tests, and explains their qualitative synthesis to provide design method validation. The seismic test program had two phases. Phase I was the testing of a seven-story mixed-use building with the first story consisting of a steel special moment frame (SMF) and stories 2–7 made of light-frame wood. In Phase II, the SMF was heavily braced such that it effectively became an extension of the shake table and testing was conducted on only stories 2–7, making the building a six-story light-frame multifami...
- 1 February 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 26 (1) , 17-25
Damage Assessment of a Full-Scale Six-Story Wood-Frame Building Following Triaxial Shake Table Tests
In the summer of 2009, a full-scale midrise wood-frame building was tested under a series of simulated earthquakes on the world’s largest shake table in Miki City, Japan. The objective of this series of tests was to validate a performance-based seismic design approach by qualitatively and quantitatively examining the building’s seismic performance in terms of response kinematics and observed damage. This paper presents the results of detailed damage inspections following each test in a series of five shake table tests, and explains their qualitative synthesis to provide design method validation. The seismic test program had two phases. Phase I was the testing of a seven-story mixed-use building with the first story consisting of a steel special moment frame (SMF) and stories 2–7 made of light-frame wood. In Phase II, the SMF was heavily braced such that it effectively became an extension of the shake table and testing was conducted on only stories 2–7, making the building a six-story light-frame multifami...