Shigehito Suzuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shigehito Suzuki has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Masahito Uesugi
Hokkaido University
4 shared publicationsKazuhiro Koshino
Department of Computer Science, Kitami Institute of Technology, 165, Koen-cho, Kitami 090-8507, Japan
3 shared publicationsHongying Zuo
Department of Computer Science, Kitami Institute of Technology, 165, Koen-cho, Kitami 090-8507, Japan
2 shared publications- Kazuhiro Koshino
Department of Systems and Informatics, Hokkaido Information University, Ebetsu 069-0832, Japan
2 shared publications Minoru Sotoda
2 shared publicationsJun'Ichi Tamaki
Department of Computer Science, Kitami Institute of Technology, 165, Koen-cho, Kitami 090-8507, Japan
1 shared publication
Latest Publications
- 27 November 2007
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 1 (1) , 62-74
Realization of reliable cerebral-blood-flow maps from low-dose CT perfusion images by statistical noise reduction using nonlinear diffusion filtering
X-ray computed tomographic perfusion (CTP) imaging, a rapid method for measuring cerebral blood flow (CBF), is an effective modality for assessment of the severity and extent of brain tissue ischemia. Low-dose scanning has been required for CTP imaging for reducing the radiation exposure to patients, because the same plane is scanned repeatedly. Low-dose CTP imaging, however, results in substantial statistical noise in the images, which may negatively impact the accuracy of CBF values. Because CBF values are calculated from the set of CTP images, it is important to reduce the statistical noise in raw CTP images to make the values reliable. Noise reduction must be performed without blurring of vessel structures, because such blurring will overestimate CBF values. For this purpose, two-dimensional nonlinear diffusion filtering (NLDF) was introduced. It was applied to CTP images of a CTP phantom for evaluating the accuracy of CBF values in low-dose CTP and to clinical low-dose CTP images for determining its effectiveness in actual CTP examinations. NLDF successfully reduced the statistical noise in the CTP images while preserving the sharp edges. This feature generated CBF values close to the reference value, producing reliable CBF maps from low-dose CT perfusion images. The CBF maps obtained with NLDF were comparable to or better than those obtained by other, commercial CTP software programs. The use of NLDF was thus effective for manipulation of low-dose CT perfusion images.
- 27 November 2007
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 1 (1) , 62-74
Realization of reliable cerebral-blood-flow maps from low-dose CT perfusion images by statistical noise reduction using nonlinear diffusion filtering
X-ray computed tomographic perfusion (CTP) imaging, a rapid method for measuring cerebral blood flow (CBF), is an effective modality for assessment of the severity and extent of brain tissue ischemia. Low-dose scanning has been required for CTP imaging for reducing the radiation exposure to patients, because the same plane is scanned repeatedly. Low-dose CTP imaging, however, results in substantial statistical noise in the images, which may negatively impact the accuracy of CBF values. Because CBF values are calculated from the set of CTP images, it is important to reduce the statistical noise in raw CTP images to make the values reliable. Noise reduction must be performed without blurring of vessel structures, because such blurring will overestimate CBF values. For this purpose, two-dimensional nonlinear diffusion filtering (NLDF) was introduced. It was applied to CTP images of a CTP phantom for evaluating the accuracy of CBF values in low-dose CTP and to clinical low-dose CTP images for determining its effectiveness in actual CTP examinations. NLDF successfully reduced the statistical noise in the CTP images while preserving the sharp edges. This feature generated CBF values close to the reference value, producing reliable CBF maps from low-dose CT perfusion images. The CBF maps obtained with NLDF were comparable to or better than those obtained by other, commercial CTP software programs. The use of NLDF was thus effective for manipulation of low-dose CT perfusion images.
- 1 January 2006
- Vol. 26 (2) , 65-74
New technique for visualizing cerebral vessels in MR angiographic images using three-dimensional discrete wavelet transform.
Visualization techniques for magnetic resonance (MR) angiographic images are generally based on the projection ray concept; for example, maximum intensity projection (MIP) and volume rendering (VR). A new technique based on a different concept from projection rays is explored in this study: three-dimensional (3-D) discrete wavelet transforms are used for visualizing cerebral vessels in the MR angiographic image. This technique successfully visualizes cerebral vessels and represents the spatial relationship between the cerebral vessels, as in the case of VR. The proposed technique is, thus, indicated to be promising for visualizing cerebral vessels in 3-D MR angiographic images.
- 1 January 2006
- Vol. 26 (2) , 65-74
New technique for visualizing cerebral vessels in MR angiographic images using three-dimensional discrete wavelet transform.
Visualization techniques for magnetic resonance (MR) angiographic images are generally based on the projection ray concept; for example, maximum intensity projection (MIP) and volume rendering (VR). A new technique based on a different concept from projection rays is explored in this study: three-dimensional (3-D) discrete wavelet transforms are used for visualizing cerebral vessels in the MR angiographic image. This technique successfully visualizes cerebral vessels and represents the spatial relationship between the cerebral vessels, as in the case of VR. The proposed technique is, thus, indicated to be promising for visualizing cerebral vessels in 3-D MR angiographic images.
- 1 October 2002
- Published by Elsevier in Optics Communications
- Vol. 211 (1-6) , 73-83
Spike noise removal in the scanning laser microscopic image of diamond abrasive grain using a wavelet transform
- 1 October 2002
- Published by Elsevier in Optics Communications
- Vol. 211 (1-6) , 73-83
Spike noise removal in the scanning laser microscopic image of diamond abrasive grain using a wavelet transform
- 1 January 2002
- Vol. 22 (4) , 287-301
The application of a new predictive technique for lossless compression of medical images.
A new predictive technique for lossless compression is applied to CT and MR images in order to achieve high compression in the lossless mode. To accomplish this, a prediction value was obtained by assuming the horizontal and vertical components of each pixel. Wide and narrow predictive coding modes were adaptively selected to achieve an accurate prediction. The performance of the predictive technique was compared with the performance of four representative compression techniques in the lossless mode, using different types of CT and MR image sets with different bit rates. Overall, the proposed predictive technique yielded the best compression, particularly with the lower bit-rate images tested. While the compression results are largely dependent on the images used, the results confirm the strong potential of the proposed predictive technique as a strategy for obtaining high lossless-compression in medical images.
- 1 January 2002
- Vol. 22 (4) , 287-301
The application of a new predictive technique for lossless compression of medical images.
A new predictive technique for lossless compression is applied to CT and MR images in order to achieve high compression in the lossless mode. To accomplish this, a prediction value was obtained by assuming the horizontal and vertical components of each pixel. Wide and narrow predictive coding modes were adaptively selected to achieve an accurate prediction. The performance of the predictive technique was compared with the performance of four representative compression techniques in the lossless mode, using different types of CT and MR image sets with different bit rates. Overall, the proposed predictive technique yielded the best compression, particularly with the lower bit-rate images tested. While the compression results are largely dependent on the images used, the results confirm the strong potential of the proposed predictive technique as a strategy for obtaining high lossless-compression in medical images.
- 1 January 2001
- Vol. 21 (3) , 157-173
Emission CT Image Reconstruction Using the Augmented Lagrangian Method with a Modified Form of Nonnegativity Constraints.
The augmented Lagrangian method was applied to emission CT image reconstruction to attain the satisfactory elimination of negative pixels using a modified form of the original nonnegativity constraints. A penalty function was included in the augmented Lagrangian method to suppress image noise due to statistical noise in the projection data. A slight change in the original constraint form achieved almost complete nonnegativity without loss in the closeness of reconstruction to the original image.
- 1 January 2001
- Vol. 21 (3) , 157-173
Emission CT Image Reconstruction Using the Augmented Lagrangian Method with a Modified Form of Nonnegativity Constraints.
The augmented Lagrangian method was applied to emission CT image reconstruction to attain the satisfactory elimination of negative pixels using a modified form of the original nonnegativity constraints. A penalty function was included in the augmented Lagrangian method to suppress image noise due to statistical noise in the projection data. A slight change in the original constraint form achieved almost complete nonnegativity without loss in the closeness of reconstruction to the original image.
- Open Access
- 1 January 1992
- Published by Japan Radioisotope Association in RADIOISOTOPES
- Vol. 41 (10) , 491-498
Image Smoothing Based on Fuzzy Reasoning. II. Application.
- 1 January 1992
- Published by Japan Radioisotope Association in RADIOISOTOPES
- Vol. 41 (10) , 491-498
Open AccessImage Smoothing Based on Fuzzy Reasoning. II. Application.
- Open Access
- 1 January 1992
- Published by Japan Radioisotope Association in RADIOISOTOPES
- Vol. 41 (10) , 483-490
Image Smoothing Based on Fuzzy Reasoning. I. Theory.
- 1 January 1992
- Published by Japan Radioisotope Association in RADIOISOTOPES
- Vol. 41 (10) , 483-490
Open AccessImage Smoothing Based on Fuzzy Reasoning. I. Theory.