Kazuhiro Koshino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kazuhiro Koshino has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Chiaki Yokota
Department of Stroke Rehabilitation, National Cerebral and Cardiovascular Center
2 shared publications - Shigehito Suzuki
Department of Computer Science, Kitami Institute of Technology, 165, Koen-cho, Kitami 090-8507, Japan
2 shared publications - Takahiro Higuchi
Department of Nuclear Medicine and Comprehensive Heart Failure Center, University Hospital of Würzburg, Würzburg, Germany
2 shared publications - Anna Tutov
Pharmaceutical and Medicinal Chemistry, Institute of Pharmacy and Food Chemistry, University of Würzburg, Würzburg, Germany
1 shared publication - Constantin Lapa
University Hospital Augsburg, Germany
1 shared publication - Daisuke Ando
Department of Materials Science, Graduate School of Engineering, Tohoku University 1 , 6-6-11, Aoba-yama, Aoba-ku, Sendai 980-8579
1 shared publication
Latest Publications
- Open Access
- 17 February 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (2) , 690
Rationalizing the Binding Modes of PET Radiotracers Targeting the Norepinephrine Transporter
Purpose: A new PET radiotracer 18F-AF78 showing great potential for clinical application has been reported recently. It belongs to a new generation of phenethylguanidine-based norepinephrine transporter (NET)-targeting radiotracers. Although many efforts have been made to develop NET inhibitors as antidepressants, systemic investigations of the structure–activity relationships (SARs) of NET-targeting radiotracers have rarely been performed. Methods: Without changing the phenethylguanidine pharmacophore and 3-fluoropropyl moiety that is crucial for easy labeling, six new analogs of 18F-AF78 with different meta-substituents on the benzene-ring were synthesized and evaluated in a competitive cellular uptake assay and in in vivo animal experiments in rats. Computational modeling of these tracers was established to quantitatively rationalize the interaction between the radiotracers and NET. Results: Using non-radiolabeled reference compounds, a competitive cellular uptake assay showed a decrease in NET-transporting affinity from meta-fluorine to iodine (0.42 and 6.51 µM, respectively), with meta-OH being the least active (22.67 µM). Furthermore, in vivo animal studies with radioisotopes showed that heart-to-blood ratios agreed with the cellular experiments, with AF78(F) exhibiting the highest cardiac uptake. This result correlates positively with the electronegativity rather than the atomic radius of the meta-substituent. Computational modeling studies revealed a crucial influence of halogen substituents on the radiotracer–NET interaction, whereby a T-shaped π–π stacking interaction between the benzene-ring of the tracer and the amino acid residues surrounding the NET binding site made major contributions to the different affinities, in accordance with the pharmacological data. Conclusion: The SARs were characterized by in vitro and in vivo evaluation, and computational modeling quantitatively rationalized the interaction between radiotracers and the NET binding site. These findings pave the way for further evaluation in different species and underline the potential of AF78(F) for clinical application, e.g., cardiac innervation imaging or molecular imaging of neuroendocrine tumors.
- 17 February 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (2) , 690
Open AccessRationalizing the Binding Modes of PET Radiotracers Targeting the Norepinephrine Transporter
Purpose: A new PET radiotracer 18F-AF78 showing great potential for clinical application has been reported recently. It belongs to a new generation of phenethylguanidine-based norepinephrine transporter (NET)-targeting radiotracers. Although many efforts have been made to develop NET inhibitors as antidepressants, systemic investigations of the structure–activity relationships (SARs) of NET-targeting radiotracers have rarely been performed. Methods: Without changing the phenethylguanidine pharmacophore and 3-fluoropropyl moiety that is crucial for easy labeling, six new analogs of 18F-AF78 with different meta-substituents on the benzene-ring were synthesized and evaluated in a competitive cellular uptake assay and in in vivo animal experiments in rats. Computational modeling of these tracers was established to quantitatively rationalize the interaction between the radiotracers and NET. Results: Using non-radiolabeled reference compounds, a competitive cellular uptake assay showed a decrease in NET-transporting affinity from meta-fluorine to iodine (0.42 and 6.51 µM, respectively), with meta-OH being the least active (22.67 µM). Furthermore, in vivo animal studies with radioisotopes showed that heart-to-blood ratios agreed with the cellular experiments, with AF78(F) exhibiting the highest cardiac uptake. This result correlates positively with the electronegativity rather than the atomic radius of the meta-substituent. Computational modeling studies revealed a crucial influence of halogen substituents on the radiotracer–NET interaction, whereby a T-shaped π–π stacking interaction between the benzene-ring of the tracer and the amino acid residues surrounding the NET binding site made major contributions to the different affinities, in accordance with the pharmacological data. Conclusion: The SARs were characterized by in vitro and in vivo evaluation, and computational modeling quantitatively rationalized the interaction between radiotracers and the NET binding site. These findings pave the way for further evaluation in different species and underline the potential of AF78(F) for clinical application, e.g., cardiac innervation imaging or molecular imaging of neuroendocrine tumors.
- 22 May 2020
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 415, 116939
Microstructural white matter changes following gait training with Hybrid Assistive Limb initiated within 1 week of stroke onset
- 22 May 2020
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 415, 116939
Microstructural white matter changes following gait training with Hybrid Assistive Limb initiated within 1 week of stroke onset
- Open Access
- 1 January 2020
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 21 (Supplement)
P1354 Prognostic value of the left ventricular longitudinal and circumferential function in patients with takotsubo syndrome during the acute phase
Background: Takotsubo syndrome is generally considered a benign disease with a reversible condition; however, hemodynamic and electrical instability during the acute phase exposes patients to the risk of serious adverse in-hospital events. The purpose of this study was to investigate the prognostic value of the left ventricular longitudinal and circumferential function in patients with TTS during the acute phase. Methods: We divided the 27 patients with TTS (77.4 ± 10.2 years old, 21 females) into two groups; the severe group (SG) of 9 patients (in-hospital death, mechanical assist devices such as IABP or ECMO, oozing rupture) and non-severe group (NSG) of 18 patients. The echocardiographic examination on admission, catheter hemodynamic assessment, and laboratory data, and ST-T change in electrocardiogram were compared between two groups. Results: There were no differences in age, laboratory data, electrocardiogram findings between the two groups. The LVEF was lower in SG (35.3 ± 6.1% vs. 45.9 ± 13.5%, p = 0.03). The index of Ballooning, the ratio of the systolic left ventricular diameter of ballooning segments to that of basal segments, was higher in SG (2.07 ± 0.61% vs.1.60 ± 0.32%, p = 0.016). The circumferential fractional shortening (CFS) of ballooning segments was lower in SG (4.6 ± 3.2% vs. 18.2 ± 8.2%, p = 0.00007), CFS of basal segments was not different between the two groups, and the ratio of CFS of ballooning segments to CFS of basal segments (CFS imbalance index) was lower in SG (5.60 ± 3.84 vs. 10.83 ± 3.92, p = 0.00003). The left ventricular longitudinal fractional shortening was lower in SG (0.12 ± 0.09 vs. 0.46 ± 0.19, p = 0.00003). The absolute value of GLS was lower in SG (7.6 ± 4.3% vs. 13.0 ± 3.6%, p = 0.002). In all three cases of in-hospital death, the CFS imbalance index was lower than 0.14. Conclusion: In patients with TTS, left ventricular longitudinal and circumferential function could be related to serious adverse in-hospital events.
- 1 January 2020
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 21 (Supplement)
Open AccessP1354 Prognostic value of the left ventricular longitudinal and circumferential function in patients with takotsubo syndrome during the acute phase
Background: Takotsubo syndrome is generally considered a benign disease with a reversible condition; however, hemodynamic and electrical instability during the acute phase exposes patients to the risk of serious adverse in-hospital events. The purpose of this study was to investigate the prognostic value of the left ventricular longitudinal and circumferential function in patients with TTS during the acute phase. Methods: We divided the 27 patients with TTS (77.4 ± 10.2 years old, 21 females) into two groups; the severe group (SG) of 9 patients (in-hospital death, mechanical assist devices such as IABP or ECMO, oozing rupture) and non-severe group (NSG) of 18 patients. The echocardiographic examination on admission, catheter hemodynamic assessment, and laboratory data, and ST-T change in electrocardiogram were compared between two groups. Results: There were no differences in age, laboratory data, electrocardiogram findings between the two groups. The LVEF was lower in SG (35.3 ± 6.1% vs. 45.9 ± 13.5%, p = 0.03). The index of Ballooning, the ratio of the systolic left ventricular diameter of ballooning segments to that of basal segments, was higher in SG (2.07 ± 0.61% vs.1.60 ± 0.32%, p = 0.016). The circumferential fractional shortening (CFS) of ballooning segments was lower in SG (4.6 ± 3.2% vs. 18.2 ± 8.2%, p = 0.00007), CFS of basal segments was not different between the two groups, and the ratio of CFS of ballooning segments to CFS of basal segments (CFS imbalance index) was lower in SG (5.60 ± 3.84 vs. 10.83 ± 3.92, p = 0.00003). The left ventricular longitudinal fractional shortening was lower in SG (0.12 ± 0.09 vs. 0.46 ± 0.19, p = 0.00003). The absolute value of GLS was lower in SG (7.6 ± 4.3% vs. 13.0 ± 3.6%, p = 0.002). In all three cases of in-hospital death, the CFS imbalance index was lower than 0.14. Conclusion: In patients with TTS, left ventricular longitudinal and circumferential function could be related to serious adverse in-hospital events.
- 20 February 2017
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 31 (3) , 227-234
Binding of 11C-Pittsburgh compound-B correlated with white matter injury in hypertensive small vessel disease
11C-Pittsburgh compound-B (11C-PIB) positron emission tomography (PET) is used to visualize and quantify amyloid deposition in the brain cortex in pathological conditions such as Alzheimer’s disease (AD). Intense 11C-PIB retention is also observed in the white matter (WM) of both healthy individuals and AD patients. However, the clinical implications of this retention in brain WM have not been clarified. We investigated the relationship between the extent of white matter lesions (WMLs) and the binding potential of 11C-PIB (BPND) in the WM in patients with hypertensive small vessel disease. We further examined the relationship between the extent of WMLs and BPND in WML and in normal-appearing white matter (NAWM). Twenty-one hypertensive vasculopathy patients, without AD and major cerebral arterial stenosis and/or occlusion, were enrolled (9 women, 68 ± 7 years). Regions of WML and NAWM were extracted using magnetization-prepared rapid gradient-echo and fluid-attenuated inversion recovery of magnetic resonance images. Volumes of interest (VOIs) were set in the cortex-subcortex, basal ganglia, and centrum semiovale (CS). BPND in the cortex-subcortex, basal ganglia, CS, WML, and NAWM were estimated on 11C-PIB PET using Logan graphical analysis with cerebellar regions as references. The relationships between WML volume and BPND in each region were examined by linear regression analysis. BPND was higher in the CS and basal ganglia than in the cortex-subcortex regions. WML volume had a significant inverse correlation with BPND in the CS (Slope = −0.0042, R2 = 0.44, P < 0.01). For intra WM comparison, BPND in NAWM was significantly higher than that in WML. In addition, although there were no correlations between WML volume and BPND in WML, WML volume was significantly correlated inversely with BPND in NAWM (Slope = −0.0017, R2 = 0.26, P = 0.02). 11C-PIB could be a marker of not only cortical amyloid-β deposition but also WM injury accompanying the development of WMLs in hypertensive small vessel disease.
- 20 February 2017
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 31 (3) , 227-234
Binding of 11C-Pittsburgh compound-B correlated with white matter injury in hypertensive small vessel disease
11C-Pittsburgh compound-B (11C-PIB) positron emission tomography (PET) is used to visualize and quantify amyloid deposition in the brain cortex in pathological conditions such as Alzheimer’s disease (AD). Intense 11C-PIB retention is also observed in the white matter (WM) of both healthy individuals and AD patients. However, the clinical implications of this retention in brain WM have not been clarified. We investigated the relationship between the extent of white matter lesions (WMLs) and the binding potential of 11C-PIB (BPND) in the WM in patients with hypertensive small vessel disease. We further examined the relationship between the extent of WMLs and BPND in WML and in normal-appearing white matter (NAWM). Twenty-one hypertensive vasculopathy patients, without AD and major cerebral arterial stenosis and/or occlusion, were enrolled (9 women, 68 ± 7 years). Regions of WML and NAWM were extracted using magnetization-prepared rapid gradient-echo and fluid-attenuated inversion recovery of magnetic resonance images. Volumes of interest (VOIs) were set in the cortex-subcortex, basal ganglia, and centrum semiovale (CS). BPND in the cortex-subcortex, basal ganglia, CS, WML, and NAWM were estimated on 11C-PIB PET using Logan graphical analysis with cerebellar regions as references. The relationships between WML volume and BPND in each region were examined by linear regression analysis. BPND was higher in the CS and basal ganglia than in the cortex-subcortex regions. WML volume had a significant inverse correlation with BPND in the CS (Slope = −0.0042, R2 = 0.44, P < 0.01). For intra WM comparison, BPND in NAWM was significantly higher than that in WML. In addition, although there were no correlations between WML volume and BPND in WML, WML volume was significantly correlated inversely with BPND in NAWM (Slope = −0.0017, R2 = 0.26, P = 0.02). 11C-PIB could be a marker of not only cortical amyloid-β deposition but also WM injury accompanying the development of WMLs in hypertensive small vessel disease.
- 27 November 2007
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 1 (1) , 62-74
Realization of reliable cerebral-blood-flow maps from low-dose CT perfusion images by statistical noise reduction using nonlinear diffusion filtering
X-ray computed tomographic perfusion (CTP) imaging, a rapid method for measuring cerebral blood flow (CBF), is an effective modality for assessment of the severity and extent of brain tissue ischemia. Low-dose scanning has been required for CTP imaging for reducing the radiation exposure to patients, because the same plane is scanned repeatedly. Low-dose CTP imaging, however, results in substantial statistical noise in the images, which may negatively impact the accuracy of CBF values. Because CBF values are calculated from the set of CTP images, it is important to reduce the statistical noise in raw CTP images to make the values reliable. Noise reduction must be performed without blurring of vessel structures, because such blurring will overestimate CBF values. For this purpose, two-dimensional nonlinear diffusion filtering (NLDF) was introduced. It was applied to CTP images of a CTP phantom for evaluating the accuracy of CBF values in low-dose CTP and to clinical low-dose CTP images for determining its effectiveness in actual CTP examinations. NLDF successfully reduced the statistical noise in the CTP images while preserving the sharp edges. This feature generated CBF values close to the reference value, producing reliable CBF maps from low-dose CT perfusion images. The CBF maps obtained with NLDF were comparable to or better than those obtained by other, commercial CTP software programs. The use of NLDF was thus effective for manipulation of low-dose CT perfusion images.
- 27 November 2007
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 1 (1) , 62-74
Realization of reliable cerebral-blood-flow maps from low-dose CT perfusion images by statistical noise reduction using nonlinear diffusion filtering
X-ray computed tomographic perfusion (CTP) imaging, a rapid method for measuring cerebral blood flow (CBF), is an effective modality for assessment of the severity and extent of brain tissue ischemia. Low-dose scanning has been required for CTP imaging for reducing the radiation exposure to patients, because the same plane is scanned repeatedly. Low-dose CTP imaging, however, results in substantial statistical noise in the images, which may negatively impact the accuracy of CBF values. Because CBF values are calculated from the set of CTP images, it is important to reduce the statistical noise in raw CTP images to make the values reliable. Noise reduction must be performed without blurring of vessel structures, because such blurring will overestimate CBF values. For this purpose, two-dimensional nonlinear diffusion filtering (NLDF) was introduced. It was applied to CTP images of a CTP phantom for evaluating the accuracy of CBF values in low-dose CTP and to clinical low-dose CTP images for determining its effectiveness in actual CTP examinations. NLDF successfully reduced the statistical noise in the CTP images while preserving the sharp edges. This feature generated CBF values close to the reference value, producing reliable CBF maps from low-dose CT perfusion images. The CBF maps obtained with NLDF were comparable to or better than those obtained by other, commercial CTP software programs. The use of NLDF was thus effective for manipulation of low-dose CT perfusion images.