Dong Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dong Huang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Rijing Zhao
Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
5 shared publications Rijing Zhao
Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
4 shared publications- Yu Sun
Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
3 shared publications Xueyuan Peng
School of Energy and Power Engineering, Xi’an Jiaotong University, No. 28, Xianning West Road, Xi’an, Shaanxi 710049, China
2 shared publications- Fei Wang
School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Fei Wang
Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
Experimental and Numerical Study on Fan-Supplied Condenser Deterioration under Built-In Condition and Its Corresponding Refrigerator Performance
The built-in refrigerator has been popular in China in recent years due to users’ high requirements for the integration of home appliances and furnishings. However, the built-in configuration will cause a significant performance deterioration, which has been less quantitively studied. The condenser and its refrigerator performance are compared experimentally and numerically between built-in and free-standing configurations. By contrast with the free-standing condition, the built-in condenser has poor performance attributed to two reasons: 28.6% lower condenser air flowrate and 10.72 °C higher condenser inlet air temperature caused by the hot short-circuited airflow. This heat dissipation deterioration increases the condensing temperature and discharge temperature, resulting in a refrigerator cooling capacity loss. Correspondingly, the compressor increases the rotating speed and power to compensate for the loss. The compressor ON-time ratio reduces by 8% but the average power during the compressor-on period increases by 56.9%, finally increasing the energy consumption by 43.4%. This study also provides some guidance for further heat dissipation and airflow field optimization of built-in refrigerators.
Open AccessExperimental and Numerical Study on Fan-Supplied Condenser Deterioration under Built-In Condition and Its Corresponding Refrigerator Performance
The built-in refrigerator has been popular in China in recent years due to users’ high requirements for the integration of home appliances and furnishings. However, the built-in configuration will cause a significant performance deterioration, which has been less quantitively studied. The condenser and its refrigerator performance are compared experimentally and numerically between built-in and free-standing configurations. By contrast with the free-standing condition, the built-in condenser has poor performance attributed to two reasons: 28.6% lower condenser air flowrate and 10.72 °C higher condenser inlet air temperature caused by the hot short-circuited airflow. This heat dissipation deterioration increases the condensing temperature and discharge temperature, resulting in a refrigerator cooling capacity loss. Correspondingly, the compressor increases the rotating speed and power to compensate for the loss. The compressor ON-time ratio reduces by 8% but the average power during the compressor-on period increases by 56.9%, finally increasing the energy consumption by 43.4%. This study also provides some guidance for further heat dissipation and airflow field optimization of built-in refrigerators.
- Open Access
- 6 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 8960
Effect of the Number of Circuits on a Finned-Tube Heat Exchanger Performance and Its Improvement by a Reversely Variable Circuitry
The finned-tube heat exchanger (FTHX) works better with more circuits as an evaporator but fewer as a condenser in air-source heat pumps (ASHPs). In this article, a reversely variable circuitry is proposed to address this contradiction. The effects of the circuit number on the performance of an outdoor FTHX in an ASHP prototype was first studied numerically using the EVAP-COND 4.0 software. We showed that the evaporator capacity reached its peak with four circuits, but the condenser capacity decreased monotonously as the circuit number increased. A reversely variable circuitry was obtained by combining distributors and check valves, so that the FTHX exhibited four circuits in the evaporator mode but one and a half (two circuits merging into one) in the condenser mode, thus better matching the respective requirements of the two modes. Comparative tests showed that in the ASHP, the reversely variable FTHX had a 6.1% higher cooling capacity than the four-circuit reversely fixed exchanger and a 3.9% higher heating capacity than the 1.5-circuit reversely fixed one. Therefore, the novel design of the FTHX enhanced both the heating and the cooling performance of the ASHP.
- 6 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 8960
Open AccessEffect of the Number of Circuits on a Finned-Tube Heat Exchanger Performance and Its Improvement by a Reversely Variable Circuitry
The finned-tube heat exchanger (FTHX) works better with more circuits as an evaporator but fewer as a condenser in air-source heat pumps (ASHPs). In this article, a reversely variable circuitry is proposed to address this contradiction. The effects of the circuit number on the performance of an outdoor FTHX in an ASHP prototype was first studied numerically using the EVAP-COND 4.0 software. We showed that the evaporator capacity reached its peak with four circuits, but the condenser capacity decreased monotonously as the circuit number increased. A reversely variable circuitry was obtained by combining distributors and check valves, so that the FTHX exhibited four circuits in the evaporator mode but one and a half (two circuits merging into one) in the condenser mode, thus better matching the respective requirements of the two modes. Comparative tests showed that in the ASHP, the reversely variable FTHX had a 6.1% higher cooling capacity than the four-circuit reversely fixed exchanger and a 3.9% higher heating capacity than the 1.5-circuit reversely fixed one. Therefore, the novel design of the FTHX enhanced both the heating and the cooling performance of the ASHP.
- Open Access
Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator
The evaporator in a frost-free refrigerator typically has more tube rows, but frost deposition reduces along the airflow direction. Correspondingly, the evaporator fin distribution is thinner in the upstream rows but denser downstream, and a good match between frost and fin distribution is achieved to recover evaporator capacity loss. However, quantitative design principles of non-uniform fin distribution are lacking. A quasi-static frosting evaporator model is established and experimentally verified considering a three-dimensional (3D) evaporator, 1D frost growth and 1D non-uniform fin distribution. An optimization method for row-by-row fin distribution of a multi-row frosting evaporator is proposed based on the air pressure drop’s increase rate. When the increase rate in the air pressure drop of each row is almost equal, the smallest overall evaporator pressure drop is obtained, leading to the highest air flowrate and the greatest evaporator capacity. By applying the method, the air flowrate and the evaporator capacity increase by 5.5% and 4.6%, respectively, compared to the original fin distribution scheme. Moreover, the robustness of the optimization method is validated under wide temperature and humidity operating conditions. An equivalent implementation under an initial no-frost condition is also proposed to facilitate the optimization method without calculating the whole frosting process.
Open AccessProposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator
The evaporator in a frost-free refrigerator typically has more tube rows, but frost deposition reduces along the airflow direction. Correspondingly, the evaporator fin distribution is thinner in the upstream rows but denser downstream, and a good match between frost and fin distribution is achieved to recover evaporator capacity loss. However, quantitative design principles of non-uniform fin distribution are lacking. A quasi-static frosting evaporator model is established and experimentally verified considering a three-dimensional (3D) evaporator, 1D frost growth and 1D non-uniform fin distribution. An optimization method for row-by-row fin distribution of a multi-row frosting evaporator is proposed based on the air pressure drop’s increase rate. When the increase rate in the air pressure drop of each row is almost equal, the smallest overall evaporator pressure drop is obtained, leading to the highest air flowrate and the greatest evaporator capacity. By applying the method, the air flowrate and the evaporator capacity increase by 5.5% and 4.6%, respectively, compared to the original fin distribution scheme. Moreover, the robustness of the optimization method is validated under wide temperature and humidity operating conditions. An equivalent implementation under an initial no-frost condition is also proposed to facilitate the optimization method without calculating the whole frosting process.
- Open Access
A Heater-Assisted Air Source Heat Pump Air Conditioner to Improve Thermal Comfort with Frost-Retarded Heating and Heat-Uninterrupted Defrosting
Frost deposits on the outdoor heat exchanger of an air source heat pump (ASHP) air conditioner and reduces its capacity during winter operation. However, the prevailing reverse-cycle defrosting (RCD) turns the indoor heat exchanger into an evaporator and ceases heat supply to the living space. Consequently, the thermal comfort for indoor occupants is deteriorated. This article proposes a heater-assisted ASHP to tackle this problem. With an 800 W electromagnetic heater equipped upstream of the outdoor heat exchanger to provide refrigerant with additional heat, the ASHP retarded frost under original throttling control and compressor speed during the heating cycle (frostless mode), and even removed frost with uninterrupted heat supply to indoor space under little throttling and reduced compressor speed (anti-frost mode). Compared with the original operation of the ASHP when the heater was off (baseline mode), frostless and anti-frost modes extended heating duration by 17.9% and 99.7%, respectively, with comparative time-averaged supply-air temperature. Moreover, COP for baseline and anti-frost modes was similar by average, about 3% higher than for the frostless mode. Further optimizations will be done on the co-adjustment of throttling control and compressor speed to better fulfill the potential of the heater-assisted ASHP.
Open AccessA Heater-Assisted Air Source Heat Pump Air Conditioner to Improve Thermal Comfort with Frost-Retarded Heating and Heat-Uninterrupted Defrosting
Frost deposits on the outdoor heat exchanger of an air source heat pump (ASHP) air conditioner and reduces its capacity during winter operation. However, the prevailing reverse-cycle defrosting (RCD) turns the indoor heat exchanger into an evaporator and ceases heat supply to the living space. Consequently, the thermal comfort for indoor occupants is deteriorated. This article proposes a heater-assisted ASHP to tackle this problem. With an 800 W electromagnetic heater equipped upstream of the outdoor heat exchanger to provide refrigerant with additional heat, the ASHP retarded frost under original throttling control and compressor speed during the heating cycle (frostless mode), and even removed frost with uninterrupted heat supply to indoor space under little throttling and reduced compressor speed (anti-frost mode). Compared with the original operation of the ASHP when the heater was off (baseline mode), frostless and anti-frost modes extended heating duration by 17.9% and 99.7%, respectively, with comparative time-averaged supply-air temperature. Moreover, COP for baseline and anti-frost modes was similar by average, about 3% higher than for the frostless mode. Further optimizations will be done on the co-adjustment of throttling control and compressor speed to better fulfill the potential of the heater-assisted ASHP.
- Open Access
Effect of Vacuum Insulation Panels on Energy Consumption and Thermal Load Transfer between Compartments in a Three-Temperature Frost-Free Refrigerator
The three-temperature frost-free refrigerator is popular in China currently, which adopts a single evaporator and separate air ducts to distribute cold air into all compartments, i.e., the fresh food compartment (FFC), the variable temperature compartment (VTC), and the freezer compartment (FZC). Two identical refrigerators with cyclopentane insulation are comparatively studied in this article, one with vacuum insulation panels (VIPs) in two sidewalls and the other without. Results show that VIPs reduce the steady-state energy consumption of the refrigerator by 12.4% due to smaller average power input and longer compressor-off duration. The decrease in average power input originates from a shorter FFC-damper-on duration since VIPs reduce its thermal load. However, the FFC average temperature rises unexpectedly with shorter damper-on and longer damper-off durations, and induces thermal load transfer from FFC to FZC through the mixing of return air in the evaporator chamber. Consequently, FZC-only duration increases and compensates for the decrease in FFC-damper-on duration, resulting in an overall similar compressor-on duration. Simulation results of the heat transfer process through the evaporator are also provided in both cases to obtain a full view of the thermal load transfer process.
Open AccessEffect of Vacuum Insulation Panels on Energy Consumption and Thermal Load Transfer between Compartments in a Three-Temperature Frost-Free Refrigerator
The three-temperature frost-free refrigerator is popular in China currently, which adopts a single evaporator and separate air ducts to distribute cold air into all compartments, i.e., the fresh food compartment (FFC), the variable temperature compartment (VTC), and the freezer compartment (FZC). Two identical refrigerators with cyclopentane insulation are comparatively studied in this article, one with vacuum insulation panels (VIPs) in two sidewalls and the other without. Results show that VIPs reduce the steady-state energy consumption of the refrigerator by 12.4% due to smaller average power input and longer compressor-off duration. The decrease in average power input originates from a shorter FFC-damper-on duration since VIPs reduce its thermal load. However, the FFC average temperature rises unexpectedly with shorter damper-on and longer damper-off durations, and induces thermal load transfer from FFC to FZC through the mixing of return air in the evaporator chamber. Consequently, FZC-only duration increases and compensates for the decrease in FFC-damper-on duration, resulting in an overall similar compressor-on duration. Simulation results of the heat transfer process through the evaporator are also provided in both cases to obtain a full view of the thermal load transfer process.
- 28 October 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (10) , 1505-1513
Reducing cabinet temperature rise during electric heater defrosting of frost-free refrigerators by using a special fan cover to block heat infiltration
Electric heater defrosting (EHD) is effective in removing frost on the evaporator and recovering capacity/COP for the frost-free refrigerator. The objective of this study is to propose a method of reducing temperature rise in the freezing cabinet (FC) during EHD process. Based on the idea of blocking the infiltration passage of the heater-generated warm air, a special cover was designed for the axial fan of the evaporator which was kept open during cooling cycles to supply cold air into cabinets normally, but was forced closed during EHD cycles so that defrost heat was prevented from infiltrating into the FC. Results show that defrost duration is shortened by 3.4%, FC-temperature rise within the defrost cycle is declined by 1.6 °C and the overall energy consumption for defrost and recovery cycles altogether is reduced by 1.9% with the fan cover. Further optimization would be made by proper delay of fan starting after defrost.
- 28 October 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (10) , 1505-1513
Reducing cabinet temperature rise during electric heater defrosting of frost-free refrigerators by using a special fan cover to block heat infiltration
Electric heater defrosting (EHD) is effective in removing frost on the evaporator and recovering capacity/COP for the frost-free refrigerator. The objective of this study is to propose a method of reducing temperature rise in the freezing cabinet (FC) during EHD process. Based on the idea of blocking the infiltration passage of the heater-generated warm air, a special cover was designed for the axial fan of the evaporator which was kept open during cooling cycles to supply cold air into cabinets normally, but was forced closed during EHD cycles so that defrost heat was prevented from infiltrating into the FC. Results show that defrost duration is shortened by 3.4%, FC-temperature rise within the defrost cycle is declined by 1.6 °C and the overall energy consumption for defrost and recovery cycles altogether is reduced by 1.9% with the fan cover. Further optimization would be made by proper delay of fan starting after defrost.
- 23 November 2018
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (4) , 387-395
Switch loss of a frost-free refrigerator-freezer with parallel dual-evaporator refrigeration system and its mitigation
The parallel dual-evaporator system has energy-saving potential in frost-free refrigerator-freezers, since it can provide proper evaporating temperature difference for the refrigerator and the freezer, respectively. However, energy loss is generated during the transition period of switches between refrigerating (R-) and freezing (F-) cycles in actual use. In this article, switch loss of a frost-free refrigerator-freezer with parallel dual-evaporator refrigeration system is studied experimentally. Results show that the transition process after F- to R-cycle switch takes 7.17 min and consists of three stages according to R-evaporator’s feeding: short feeding (1.83 min), no feeding (2 min), and continuous feeding (3.34 min). The starvation in R-evaporator during the first two stages leads to switch loss for the refrigerator-freezer, by consuming 23.3% electric energy but yielding only 6.9% capacity for an entire R-cycle. The pump-down (P/D) action before R-cycles accelerates refrigerant’s pumping from F-evaporator and feeding to R-evaporator, thus recovering part of the capacity loss. However, the introduction of P/D is not necessarily energy-efficient because P/D itself consumes considerable electric energy. By contrast, R- to F-cycle switch has little effect on refrigerator-freezer performance due to instant feeding. Dynamic simulation on the transition process will be provided in the future.
- 23 November 2018
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (4) , 387-395
Switch loss of a frost-free refrigerator-freezer with parallel dual-evaporator refrigeration system and its mitigation
The parallel dual-evaporator system has energy-saving potential in frost-free refrigerator-freezers, since it can provide proper evaporating temperature difference for the refrigerator and the freezer, respectively. However, energy loss is generated during the transition period of switches between refrigerating (R-) and freezing (F-) cycles in actual use. In this article, switch loss of a frost-free refrigerator-freezer with parallel dual-evaporator refrigeration system is studied experimentally. Results show that the transition process after F- to R-cycle switch takes 7.17 min and consists of three stages according to R-evaporator’s feeding: short feeding (1.83 min), no feeding (2 min), and continuous feeding (3.34 min). The starvation in R-evaporator during the first two stages leads to switch loss for the refrigerator-freezer, by consuming 23.3% electric energy but yielding only 6.9% capacity for an entire R-cycle. The pump-down (P/D) action before R-cycles accelerates refrigerant’s pumping from F-evaporator and feeding to R-evaporator, thus recovering part of the capacity loss. However, the introduction of P/D is not necessarily energy-efficient because P/D itself consumes considerable electric energy. By contrast, R- to F-cycle switch has little effect on refrigerator-freezer performance due to instant feeding. Dynamic simulation on the transition process will be provided in the future.
- 13 September 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 23 (1) , 211-217
Effect of defrost heat leakage on freezer temperature rise during periodical defrost cycles in a frost-free refrigerator–freezer with an electric defrost heater
Periodical defrost actions are essential for the frost-free refrigerator–freezer to remove frost on the evaporator and recover its heat transfer performance. However, defrost heat could leak into the freezer and raise its temperature during defrost cycles. In this article, the effect of defrost heat leakage on freezer temperature rise of a frost-free refrigerator–freezer using an electric defrost heater was experimentally investigated. The defrost cycle was subdivided into three stages: heating, melting, and draining. Results show that in the heating stage, little warm air leaked into the freezer due to the obstruction of the frosted evaporator, so freezer temperature hardly rose (by less than 0.1°C/min). In the melting stage, flow area between adjacent fins gradually enlarged with frost melting from the bottom to the top of the evaporator; thus, warm air leaked into the freezer, raising its temperature by 0.6°C/min in average. In the draining stage, the adjacent-fin flow area reached maximum as nearly all the frost had been removed throughout the evaporator; hence, large amount of warm air entered the freezer and raised its temperature by 1.0°C/min. To the best of the author's knowledge, the stage-based acceleration in freezer temperature rise during defrost cycles was covered for the first time.
- 13 September 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 23 (1) , 211-217
Effect of defrost heat leakage on freezer temperature rise during periodical defrost cycles in a frost-free refrigerator–freezer with an electric defrost heater
Periodical defrost actions are essential for the frost-free refrigerator–freezer to remove frost on the evaporator and recover its heat transfer performance. However, defrost heat could leak into the freezer and raise its temperature during defrost cycles. In this article, the effect of defrost heat leakage on freezer temperature rise of a frost-free refrigerator–freezer using an electric defrost heater was experimentally investigated. The defrost cycle was subdivided into three stages: heating, melting, and draining. Results show that in the heating stage, little warm air leaked into the freezer due to the obstruction of the frosted evaporator, so freezer temperature hardly rose (by less than 0.1°C/min). In the melting stage, flow area between adjacent fins gradually enlarged with frost melting from the bottom to the top of the evaporator; thus, warm air leaked into the freezer, raising its temperature by 0.6°C/min in average. In the draining stage, the adjacent-fin flow area reached maximum as nearly all the frost had been removed throughout the evaporator; hence, large amount of warm air entered the freezer and raised its temperature by 1.0°C/min. To the best of the author's knowledge, the stage-based acceleration in freezer temperature rise during defrost cycles was covered for the first time.