Yu Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu Sun has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Dong Huang
Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
3 shared publications - Rijing Zhao
Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
3 shared publications - Fei Wang
School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Siyuan Wu
Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Yikun Yang
Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Zengpeng Wang
School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication
Latest Publications
- Open Access
Experimental and Numerical Study on Fan-Supplied Condenser Deterioration under Built-In Condition and Its Corresponding Refrigerator Performance
The built-in refrigerator has been popular in China in recent years due to users’ high requirements for the integration of home appliances and furnishings. However, the built-in configuration will cause a significant performance deterioration, which has been less quantitively studied. The condenser and its refrigerator performance are compared experimentally and numerically between built-in and free-standing configurations. By contrast with the free-standing condition, the built-in condenser has poor performance attributed to two reasons: 28.6% lower condenser air flowrate and 10.72 °C higher condenser inlet air temperature caused by the hot short-circuited airflow. This heat dissipation deterioration increases the condensing temperature and discharge temperature, resulting in a refrigerator cooling capacity loss. Correspondingly, the compressor increases the rotating speed and power to compensate for the loss. The compressor ON-time ratio reduces by 8% but the average power during the compressor-on period increases by 56.9%, finally increasing the energy consumption by 43.4%. This study also provides some guidance for further heat dissipation and airflow field optimization of built-in refrigerators.
Open AccessExperimental and Numerical Study on Fan-Supplied Condenser Deterioration under Built-In Condition and Its Corresponding Refrigerator Performance
The built-in refrigerator has been popular in China in recent years due to users’ high requirements for the integration of home appliances and furnishings. However, the built-in configuration will cause a significant performance deterioration, which has been less quantitively studied. The condenser and its refrigerator performance are compared experimentally and numerically between built-in and free-standing configurations. By contrast with the free-standing condition, the built-in condenser has poor performance attributed to two reasons: 28.6% lower condenser air flowrate and 10.72 °C higher condenser inlet air temperature caused by the hot short-circuited airflow. This heat dissipation deterioration increases the condensing temperature and discharge temperature, resulting in a refrigerator cooling capacity loss. Correspondingly, the compressor increases the rotating speed and power to compensate for the loss. The compressor ON-time ratio reduces by 8% but the average power during the compressor-on period increases by 56.9%, finally increasing the energy consumption by 43.4%. This study also provides some guidance for further heat dissipation and airflow field optimization of built-in refrigerators.
- Open Access
- 6 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 8960
Effect of the Number of Circuits on a Finned-Tube Heat Exchanger Performance and Its Improvement by a Reversely Variable Circuitry
The finned-tube heat exchanger (FTHX) works better with more circuits as an evaporator but fewer as a condenser in air-source heat pumps (ASHPs). In this article, a reversely variable circuitry is proposed to address this contradiction. The effects of the circuit number on the performance of an outdoor FTHX in an ASHP prototype was first studied numerically using the EVAP-COND 4.0 software. We showed that the evaporator capacity reached its peak with four circuits, but the condenser capacity decreased monotonously as the circuit number increased. A reversely variable circuitry was obtained by combining distributors and check valves, so that the FTHX exhibited four circuits in the evaporator mode but one and a half (two circuits merging into one) in the condenser mode, thus better matching the respective requirements of the two modes. Comparative tests showed that in the ASHP, the reversely variable FTHX had a 6.1% higher cooling capacity than the four-circuit reversely fixed exchanger and a 3.9% higher heating capacity than the 1.5-circuit reversely fixed one. Therefore, the novel design of the FTHX enhanced both the heating and the cooling performance of the ASHP.
- 6 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 8960
Open AccessEffect of the Number of Circuits on a Finned-Tube Heat Exchanger Performance and Its Improvement by a Reversely Variable Circuitry
The finned-tube heat exchanger (FTHX) works better with more circuits as an evaporator but fewer as a condenser in air-source heat pumps (ASHPs). In this article, a reversely variable circuitry is proposed to address this contradiction. The effects of the circuit number on the performance of an outdoor FTHX in an ASHP prototype was first studied numerically using the EVAP-COND 4.0 software. We showed that the evaporator capacity reached its peak with four circuits, but the condenser capacity decreased monotonously as the circuit number increased. A reversely variable circuitry was obtained by combining distributors and check valves, so that the FTHX exhibited four circuits in the evaporator mode but one and a half (two circuits merging into one) in the condenser mode, thus better matching the respective requirements of the two modes. Comparative tests showed that in the ASHP, the reversely variable FTHX had a 6.1% higher cooling capacity than the four-circuit reversely fixed exchanger and a 3.9% higher heating capacity than the 1.5-circuit reversely fixed one. Therefore, the novel design of the FTHX enhanced both the heating and the cooling performance of the ASHP.
- Open Access
Proposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator
The evaporator in a frost-free refrigerator typically has more tube rows, but frost deposition reduces along the airflow direction. Correspondingly, the evaporator fin distribution is thinner in the upstream rows but denser downstream, and a good match between frost and fin distribution is achieved to recover evaporator capacity loss. However, quantitative design principles of non-uniform fin distribution are lacking. A quasi-static frosting evaporator model is established and experimentally verified considering a three-dimensional (3D) evaporator, 1D frost growth and 1D non-uniform fin distribution. An optimization method for row-by-row fin distribution of a multi-row frosting evaporator is proposed based on the air pressure drop’s increase rate. When the increase rate in the air pressure drop of each row is almost equal, the smallest overall evaporator pressure drop is obtained, leading to the highest air flowrate and the greatest evaporator capacity. By applying the method, the air flowrate and the evaporator capacity increase by 5.5% and 4.6%, respectively, compared to the original fin distribution scheme. Moreover, the robustness of the optimization method is validated under wide temperature and humidity operating conditions. An equivalent implementation under an initial no-frost condition is also proposed to facilitate the optimization method without calculating the whole frosting process.
Open AccessProposal, Robustness Analysis and Equivalent Implementation of Optimization Method for Row-by-Row Fin Distribution in Multi-Row Frosting Evaporator
The evaporator in a frost-free refrigerator typically has more tube rows, but frost deposition reduces along the airflow direction. Correspondingly, the evaporator fin distribution is thinner in the upstream rows but denser downstream, and a good match between frost and fin distribution is achieved to recover evaporator capacity loss. However, quantitative design principles of non-uniform fin distribution are lacking. A quasi-static frosting evaporator model is established and experimentally verified considering a three-dimensional (3D) evaporator, 1D frost growth and 1D non-uniform fin distribution. An optimization method for row-by-row fin distribution of a multi-row frosting evaporator is proposed based on the air pressure drop’s increase rate. When the increase rate in the air pressure drop of each row is almost equal, the smallest overall evaporator pressure drop is obtained, leading to the highest air flowrate and the greatest evaporator capacity. By applying the method, the air flowrate and the evaporator capacity increase by 5.5% and 4.6%, respectively, compared to the original fin distribution scheme. Moreover, the robustness of the optimization method is validated under wide temperature and humidity operating conditions. An equivalent implementation under an initial no-frost condition is also proposed to facilitate the optimization method without calculating the whole frosting process.