Ehsan Zolfonoun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ehsan Zolfonoun has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Seyed Reza Yousefi
Materials and Nuclear Fuel Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
3 shared publicationsAkbar Boveiri Monji
Nuclear Science and Technology Research Institute, P.O. Box 11365/8486, Tehran, Iran
1 shared publicationMaryam Salahinejad
Environmental Laboratory, NSTRI, Tehran, Iran
1 shared publicationMohammad Taghizadeh
Nuclear Science and Technology Research Institute, P.O. Box 11365/8486, Tehran, Iran
1 shared publicationSeyed Javad Ahmadi
Nuclear Science and Technology Research Institute, P.O. Box 11365/8486, Tehran, Iran
1 shared publication- Seyed Reza Yousefi
Materials and Nuclear Fuel Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
1 shared publication
Latest Publications
- 16 June 2020
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 102 (16) , 4031-4041
Exfoliated graphitic carbon nitride nanosheets for on-line vortex-assisted dispersive micro-solid phase extraction of indium prior to determination by ICP-OES
A new online vortex-assisted dispersive micro-solid phase extraction method was developed for the preconcentration of trace amounts of indium as a prior step to its determination by inductively coupled plasma-optical emission spectrometry. The methodology is based on the direct adsorption of In(III) ions by the graphitic carbon nitride nanosheets without using any chelating agent. In this method, after dispersion of sorbent particles into the sample solution, the resulting suspension was passed through a membrane filter and subsequently, the adsorbed In(III) ions were eluted from the membrane and directly introduced into the ICP-OES spectrometer. The developed on-line technique facilitates the conventional D-µSPE method by eliminating the centrifugation stage. Under the optimum conditions, the detection limit for the determination of In(III) was found to be 0.32 µg L−1. The developed method was employed for the preconcentration and quantitation of indium in various water samples.
- 16 June 2020
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 102 (16) , 4031-4041
Exfoliated graphitic carbon nitride nanosheets for on-line vortex-assisted dispersive micro-solid phase extraction of indium prior to determination by ICP-OES
A new online vortex-assisted dispersive micro-solid phase extraction method was developed for the preconcentration of trace amounts of indium as a prior step to its determination by inductively coupled plasma-optical emission spectrometry. The methodology is based on the direct adsorption of In(III) ions by the graphitic carbon nitride nanosheets without using any chelating agent. In this method, after dispersion of sorbent particles into the sample solution, the resulting suspension was passed through a membrane filter and subsequently, the adsorbed In(III) ions were eluted from the membrane and directly introduced into the ICP-OES spectrometer. The developed on-line technique facilitates the conventional D-µSPE method by eliminating the centrifugation stage. Under the optimum conditions, the detection limit for the determination of In(III) was found to be 0.32 µg L−1. The developed method was employed for the preconcentration and quantitation of indium in various water samples.
- 13 July 2016
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 104 (11) , 801-807
On-line solid phase extraction using ion-pair microparticles combined with ICP-OES for the simultaneous preconcentration and determination of uranium and thorium
In this work, after on-line and in-situ solid phase extraction technique was used for the extraction and preconcentration of uranium and thorium from aqueous samples prior to inductively coupled plasma optical emission spectrometry (ICP-OES) determination. In this method, sodium hexafluorophosphate (as an ion-pairing agent) was added to the sample solution containing the cationic surfactant (dodecyltrimethylammonium bromide) and the complexing agent (dibenzoylmethane). A cloudy solution was formed as a result of formation of an ion pair between surfactant and hexafluorophosphate. The solid microparticles were passed through a microcolumn filter and the adsorbed microparticles were subsequently eluted with acid, which was directly introduced into the ICP-OES nebulizer. The main variables affecting the pre-concentration and determination steps of uranium and thorium were studied and optimized. Under the optimum conditions, the enhancement factors of 97 and 95 and the detection limits of 0.52 and 0.21 μg L−1 were obtained for uranium and thorium, respectively.
- 13 July 2016
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 104 (11) , 801-807
On-line solid phase extraction using ion-pair microparticles combined with ICP-OES for the simultaneous preconcentration and determination of uranium and thorium
In this work, after on-line and in-situ solid phase extraction technique was used for the extraction and preconcentration of uranium and thorium from aqueous samples prior to inductively coupled plasma optical emission spectrometry (ICP-OES) determination. In this method, sodium hexafluorophosphate (as an ion-pairing agent) was added to the sample solution containing the cationic surfactant (dodecyltrimethylammonium bromide) and the complexing agent (dibenzoylmethane). A cloudy solution was formed as a result of formation of an ion pair between surfactant and hexafluorophosphate. The solid microparticles were passed through a microcolumn filter and the adsorbed microparticles were subsequently eluted with acid, which was directly introduced into the ICP-OES nebulizer. The main variables affecting the pre-concentration and determination steps of uranium and thorium were studied and optimized. Under the optimum conditions, the enhancement factors of 97 and 95 and the detection limits of 0.52 and 0.21 μg L−1 were obtained for uranium and thorium, respectively.
- 5 February 2016
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 96 (3) , 203-211
On-line extraction and determination of uranium in aqueous samples using multi-walled carbon nanotubes-coated cellulose acetate membrane
In this work, multi-walled carbon nanotubes (MWCNTs)-coated cellulose acetate membrane was used for on-line extraction and pre-concentration of uranium from aqueous samples prior to inductively coupled plasma optical emission spectrometry (ICP-OES) determination. Sample solutions containing the U(VI)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Br-PADAP) complex were passed through the membrane. The adsorbed analyte was subsequently eluted from the membrane with acid, which was directly introduced into the ICP-OES nebuliser. The main variables affecting the pre-concentration and determination steps of uranium were studied and optimised. Under the optimised conditions, the enrichment factor of 150 and the detection limit of 0.16 μg L–1 were obtained. This method was successfully used for determination of uranium in environmental water samples.
- 5 February 2016
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 96 (3) , 203-211
On-line extraction and determination of uranium in aqueous samples using multi-walled carbon nanotubes-coated cellulose acetate membrane
In this work, multi-walled carbon nanotubes (MWCNTs)-coated cellulose acetate membrane was used for on-line extraction and pre-concentration of uranium from aqueous samples prior to inductively coupled plasma optical emission spectrometry (ICP-OES) determination. Sample solutions containing the U(VI)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Br-PADAP) complex were passed through the membrane. The adsorbed analyte was subsequently eluted from the membrane with acid, which was directly introduced into the ICP-OES nebuliser. The main variables affecting the pre-concentration and determination steps of uranium were studied and optimised. Under the optimised conditions, the enrichment factor of 150 and the detection limit of 0.16 μg L–1 were obtained. This method was successfully used for determination of uranium in environmental water samples.
- 14 September 2015
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 103 (12) , 835-841
Sorption and preconcentration of uranium and thorium from aqueous solutions using multi-walled carbon nanotubes decorated with magnetic nanoparticles
The presented study investigates application of MWCNTs-Fe3O4 nanocomposite as an adsorbent for solid phase extraction and preconcentration of uranium and thorium prior to inductively coupled plasma optical emission spectrometry determination. The magnetic MWCNTs with adsorbed analytes can be easily separated from the aqueous solution by using an external magnet without additional centrifugation or filtration of the sample. Due to the high surface area of MWCNTs, satisfactory concentration factor and extraction recovery can be achieved with only 10 mg nanocomposite in 5 min. The effects of pH, sorbent amount, eluent type, chelating reagent concentration, sample volume and time on the recovery of the analytes were investigated. Under the optimum conditions, the detection limits for U(VI) and Th(IV) were 0.44 and 0.27 μg L –1, respectively.
- 14 September 2015
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 103 (12) , 835-841
Sorption and preconcentration of uranium and thorium from aqueous solutions using multi-walled carbon nanotubes decorated with magnetic nanoparticles
The presented study investigates application of MWCNTs-Fe3O4 nanocomposite as an adsorbent for solid phase extraction and preconcentration of uranium and thorium prior to inductively coupled plasma optical emission spectrometry determination. The magnetic MWCNTs with adsorbed analytes can be easily separated from the aqueous solution by using an external magnet without additional centrifugation or filtration of the sample. Due to the high surface area of MWCNTs, satisfactory concentration factor and extraction recovery can be achieved with only 10 mg nanocomposite in 5 min. The effects of pH, sorbent amount, eluent type, chelating reagent concentration, sample volume and time on the recovery of the analytes were investigated. Under the optimum conditions, the detection limits for U(VI) and Th(IV) were 0.44 and 0.27 μg L –1, respectively.
- 12 August 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (9) , 2003-2009
Determination of 6 Li and 7 Li abundances by inductively coupled plasma-optical emission spectrometry combined with derivative spectroscopy, multivariate curve resolution and multivariate calibration methods
The development of a rapid method for the determination of 6 Li and 7 Li abundances by ICP-OES coupled with computational methods.
- 12 August 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (9) , 2003-2009
Determination of 6 Li and 7 Li abundances by inductively coupled plasma-optical emission spectrometry combined with derivative spectroscopy, multivariate curve resolution and multivariate calibration methods
The development of a rapid method for the determination of 6 Li and 7 Li abundances by ICP-OES coupled with computational methods.
- 4 August 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 298 (3) , 1801-1807
Preconcentration procedure using vortex-assisted liquid–liquid microextraction for the fast determination of trace levels of thorium in water samples
- 4 August 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 298 (3) , 1801-1807
Preconcentration procedure using vortex-assisted liquid–liquid microextraction for the fast determination of trace levels of thorium in water samples
- 1 August 2010
- Published by Elsevier in Minerals Engineering
- Vol. 23 (9) , 755-756
Selective and direct sorption of zirconium from acidic leach liquor of zircon concentrate by rice bran
- 1 August 2010
- Published by Elsevier in Minerals Engineering
- Vol. 23 (9) , 755-756
Selective and direct sorption of zirconium from acidic leach liquor of zircon concentrate by rice bran