Seyed Reza Yousefi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seyed Reza Yousefi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Ehsan Zolfonoun
Materials and Nuclear Fuel Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
4 shared publicationsSeyed Javad Ahmadi
NFCRS, Nuclear Science and Technology Research Institute, Tehran, Iran
2 shared publicationsAli‐Reza Salehpour
Analytical Laboratory, School of Chemical Engineering College of Engineering, University of Tehran Tehran Iran
1 shared publication- Ehsan Zolfonoun
NFCRS, Nuclear Science and Technology Research Institute, Tehran, Iran
1 shared publication Maryam Nedaei
Department of Chemistry, Payame Noor University, Tehran, Iran
1 shared publicationMohammad Reza Pourjavid
NFCRS, Nuclear Science and Technology Research Institute, Tehran, Iran
1 shared publication
Latest Publications
- 6 May 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (5) , 595-599
A Novel Online Hydride Generation Technique for the Simultaneous Determination of Ultra Trace Amounts of Hydride Forming Elements in Water Samples by Inductively Coupled Plasma Optical Emission Spectrometry
A simple and rapid online hydride generation technique based on ultrasonic nebulizer was applied for the first time for the simultaneous determination of trace amounts of As, Bi, Sb, Se and Te by inductively coupled plasma optical emission spectrometry. In this method, we used an ultrasonic nebulizer as a hydride generator and sample introducer simultaneously. An ultrasonic nebulizer was applied for the online hydride generation technique without using any device, such as a gas phase separator, which is mandatory in the classic hydride generation method. This technique improved method detection limit comparing to the traditional hydride generation system which is a necessity in the ultra-trace determination of hydride forming elements. The developed technique shows an improvement factor ranging from 56 to 450 times in detection limits in comparison to a concentric nebulizer. The obtained detection limits were well below the maximum concentration limit. The practical applicability of the developed method was examined using natural water samples.
- 6 May 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (5) , 595-599
A Novel Online Hydride Generation Technique for the Simultaneous Determination of Ultra Trace Amounts of Hydride Forming Elements in Water Samples by Inductively Coupled Plasma Optical Emission Spectrometry
A simple and rapid online hydride generation technique based on ultrasonic nebulizer was applied for the first time for the simultaneous determination of trace amounts of As, Bi, Sb, Se and Te by inductively coupled plasma optical emission spectrometry. In this method, we used an ultrasonic nebulizer as a hydride generator and sample introducer simultaneously. An ultrasonic nebulizer was applied for the online hydride generation technique without using any device, such as a gas phase separator, which is mandatory in the classic hydride generation method. This technique improved method detection limit comparing to the traditional hydride generation system which is a necessity in the ultra-trace determination of hydride forming elements. The developed technique shows an improvement factor ranging from 56 to 450 times in detection limits in comparison to a concentric nebulizer. The obtained detection limits were well below the maximum concentration limit. The practical applicability of the developed method was examined using natural water samples.
- 13 July 2016
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 104 (11) , 801-807
On-line solid phase extraction using ion-pair microparticles combined with ICP-OES for the simultaneous preconcentration and determination of uranium and thorium
In this work, after on-line and in-situ solid phase extraction technique was used for the extraction and preconcentration of uranium and thorium from aqueous samples prior to inductively coupled plasma optical emission spectrometry (ICP-OES) determination. In this method, sodium hexafluorophosphate (as an ion-pairing agent) was added to the sample solution containing the cationic surfactant (dodecyltrimethylammonium bromide) and the complexing agent (dibenzoylmethane). A cloudy solution was formed as a result of formation of an ion pair between surfactant and hexafluorophosphate. The solid microparticles were passed through a microcolumn filter and the adsorbed microparticles were subsequently eluted with acid, which was directly introduced into the ICP-OES nebulizer. The main variables affecting the pre-concentration and determination steps of uranium and thorium were studied and optimized. Under the optimum conditions, the enhancement factors of 97 and 95 and the detection limits of 0.52 and 0.21 μg L−1 were obtained for uranium and thorium, respectively.
- 13 July 2016
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 104 (11) , 801-807
On-line solid phase extraction using ion-pair microparticles combined with ICP-OES for the simultaneous preconcentration and determination of uranium and thorium
In this work, after on-line and in-situ solid phase extraction technique was used for the extraction and preconcentration of uranium and thorium from aqueous samples prior to inductively coupled plasma optical emission spectrometry (ICP-OES) determination. In this method, sodium hexafluorophosphate (as an ion-pairing agent) was added to the sample solution containing the cationic surfactant (dodecyltrimethylammonium bromide) and the complexing agent (dibenzoylmethane). A cloudy solution was formed as a result of formation of an ion pair between surfactant and hexafluorophosphate. The solid microparticles were passed through a microcolumn filter and the adsorbed microparticles were subsequently eluted with acid, which was directly introduced into the ICP-OES nebulizer. The main variables affecting the pre-concentration and determination steps of uranium and thorium were studied and optimized. Under the optimum conditions, the enhancement factors of 97 and 95 and the detection limits of 0.52 and 0.21 μg L−1 were obtained for uranium and thorium, respectively.
- 28 July 2014
- Published by Wiley in Journal of Separation Science
- Vol. 37 (17) , 2372-2379
Determination of organophosphorus pesticides by gas chromatography with mass spectrometry using a large‐volume injection technique after magnetic extraction
A fast and efficient method was developed for the extraction and determination of organophosphorus pesticides in water samples. Organophosphorus pesticides were extracted by solid‐phase extraction using magnetic multi‐walled carbon nanotubes and determined by gas chromatography with ion‐trap mass spectrometry. Parameters affecting the extraction were investigated. Under optimum conditions of the method, 10 mg magnetic multi‐walled carbon nanotubes were added into 10 mL sample. After 2 min, adsorbent particles settled at the bottom of test tube with a magnet. After removing aqueous supernatant, the analytes were desorbed with acetonitrile. Then, 70 μL of acetonitrile phase was injected into the gas chromatography and mass spectrometry system that had an ion‐trap analyzer. To achieve high sensitivity, the large‐volume‐injection technique was used with a programmed temperature vaporization inlet, and the ion‐trap mass spectrometer was operated in single ion storage mode. Under the best conditions, the enrichment factors and extraction recoveries were in the range of 113–124 and 74–103%, respectively. The limits of detection were between 3 and 15 ng/L, and the relative standard deviations were < 10%. This method was successfully used for the determination of organophosphorus pesticides in dam water, lagoon water, and river water samples with good reproducibility and recovery.
- 28 July 2014
- Published by Wiley in Journal of Separation Science
- Vol. 37 (17) , 2372-2379
Determination of organophosphorus pesticides by gas chromatography with mass spectrometry using a large‐volume injection technique after magnetic extraction
A fast and efficient method was developed for the extraction and determination of organophosphorus pesticides in water samples. Organophosphorus pesticides were extracted by solid‐phase extraction using magnetic multi‐walled carbon nanotubes and determined by gas chromatography with ion‐trap mass spectrometry. Parameters affecting the extraction were investigated. Under optimum conditions of the method, 10 mg magnetic multi‐walled carbon nanotubes were added into 10 mL sample. After 2 min, adsorbent particles settled at the bottom of test tube with a magnet. After removing aqueous supernatant, the analytes were desorbed with acetonitrile. Then, 70 μL of acetonitrile phase was injected into the gas chromatography and mass spectrometry system that had an ion‐trap analyzer. To achieve high sensitivity, the large‐volume‐injection technique was used with a programmed temperature vaporization inlet, and the ion‐trap mass spectrometer was operated in single ion storage mode. Under the best conditions, the enrichment factors and extraction recoveries were in the range of 113–124 and 74–103%, respectively. The limits of detection were between 3 and 15 ng/L, and the relative standard deviations were < 10%. This method was successfully used for the determination of organophosphorus pesticides in dam water, lagoon water, and river water samples with good reproducibility and recovery.
- 17 March 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (11) , 3694-3699
On-line surfactant-based extraction using ion-pair microparticles combined with ICP-OES for simultaneous preconcentration and determination of rare earth elements in aqueous samples
We have developed an on-line and in situ method for the extraction and preconcentration of rare earth elements prior to their determination by inductively coupled plasma optical emission spectrometry. The cationic surfactant dodecyltrimethylammonium bromide and the chelator PAN are first added to the aqueous sample, followed by hexafluorophosphate (acting as an ion-pairing agent), upon which solutions turn cloudy due to formation of an ion pair between the surfactant and hexafluorophosphate. The solid microparticles were passed through a microcolumn filter of μm pore size, and the adsorbed microparticles (containing the REE–PAN complex) were then eluted with acid which was directly introduced into the ICP-OES nebulizer. Several factors affecting the preconcentration and determination steps were optimized. Under the optimized conditions and preconcentration of 20 mL of sample, the enhancement factors of 90–102 and the detection limits of 0.02–1 μg L−1 were obtained.
- 17 March 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (11) , 3694-3699
On-line surfactant-based extraction using ion-pair microparticles combined with ICP-OES for simultaneous preconcentration and determination of rare earth elements in aqueous samples
We have developed an on-line and in situ method for the extraction and preconcentration of rare earth elements prior to their determination by inductively coupled plasma optical emission spectrometry. The cationic surfactant dodecyltrimethylammonium bromide and the chelator PAN are first added to the aqueous sample, followed by hexafluorophosphate (acting as an ion-pairing agent), upon which solutions turn cloudy due to formation of an ion pair between the surfactant and hexafluorophosphate. The solid microparticles were passed through a microcolumn filter of μm pore size, and the adsorbed microparticles (containing the REE–PAN complex) were then eluted with acid which was directly introduced into the ICP-OES nebulizer. Several factors affecting the preconcentration and determination steps were optimized. Under the optimized conditions and preconcentration of 20 mL of sample, the enhancement factors of 90–102 and the detection limits of 0.02–1 μg L−1 were obtained.
- 27 December 2013
- Published by Taylor & Francis in Analytical Letters
- Vol. 47 (1) , 146-154
On-Line Standard Addition Technique for the Determination of Elements in the Samples with High Dissolved Solids by ICP-OES: Application to Determination of Rare Earth Elements in Geological Samples
A simple and rapid on-line standard addition method for analysis of samples with high dissolved solids by ICP-OES is reported. The method involves on-line addition of standard solutions to the sample using a T-piece, prior to the sample introduction system. The standard addition method is commonly used in the analysis of samples with complex matrices. However, the conventional standard addition method is a tedious and time-consuming process. Therefore, in this study, on-line standard addition technique was offered to significantly decrease the analysis time and increase the simplicity of the standard addition method. The performance of the proposed method was tested by determination of rare earth elements in geological samples. This method showed a high level of accuracy in comparison with external calibration and internal standard addition methods.
- 27 December 2013
- Published by Taylor & Francis in Analytical Letters
- Vol. 47 (1) , 146-154
On-Line Standard Addition Technique for the Determination of Elements in the Samples with High Dissolved Solids by ICP-OES: Application to Determination of Rare Earth Elements in Geological Samples
A simple and rapid on-line standard addition method for analysis of samples with high dissolved solids by ICP-OES is reported. The method involves on-line addition of standard solutions to the sample using a T-piece, prior to the sample introduction system. The standard addition method is commonly used in the analysis of samples with complex matrices. However, the conventional standard addition method is a tedious and time-consuming process. Therefore, in this study, on-line standard addition technique was offered to significantly decrease the analysis time and increase the simplicity of the standard addition method. The performance of the proposed method was tested by determination of rare earth elements in geological samples. This method showed a high level of accuracy in comparison with external calibration and internal standard addition methods.