MBManuel J. Betancur

Manuel J. Betancur

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Manuel J. Betancur has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validating Questionnaires for Lower Limb Rehabilitation Systems and Devices: A Scoping Review

    by Angie D. Moscoso, Vera Z. Pérez, Manuel J. Betancur

    This article aims to make a scoping review of Validating Questionnaires used in the field of lower limb (LL) rehabilitation in which systems, devices or exergames are used. Its main objective is to provide a more comprehensive understanding of the results obtained in the validation of questionnaires, as well as to identify specific criteria for evaluating systems, devices or exergames in the area of LL rehabilitation, through the analysis of validating instruments and their application in different associated contexts. The article details the methodology employed, a PRISMA ScR method review which included database research and an evaluation of the selected studies. Inclusion and exclusion criteria were applied to select all relevant studies, resulting in 81 studies after initial review based on titles and abstracts. Subsequently, the criteria were again applied to read the full text, resulting in 58 final studies. The document distinguishes between standardized and non-standardized validating questionnaires, emphasizing that standardized validating questionnaires have undergone rigorous statistical processes to ensure their validity, reliability and consistency. The information compiled in the tables provides a solid basis for identifying and evaluating validation questionnaires in the above-mentioned context. This resource constitutes an accurate and reliable reference for selecting the most appropriate instruments for future research and comparisons with similar work. This article is a valuable resource for those interested in the validation of questionnaires used in the field of lower limb rehabilitation systems/devices/exergames.


  • Open Access

    Virtual Reality Game for Physical and Emotional Rehabilitation of Landmine Victims

    by Vera Z. Pérez, Juan C. Yepes, John F. Vargas, Juan C. Franco, Natalia I. Escobar, Leonardo Betancur, Juanita Sánchez, Manuel J. Betancur

    Landmine victims require an engaging and immersive rehabilitation process to maintain motivation and therapeutic adherence, such as virtual reality games. This paper proposes a virtual reality exercise game called Exogames, which works with Nukawa, a lower limb rehabilitation robot (LLRR). Together, they constitute the general Kina system. The design and development process of Exogames is reported, as well as the evaluation of its potential for physical and emotional rehabilitation. In an initial survey designed ad-hoc, 13 health professionals evaluated compliance with various requirements. They agreed that Exogames would help the user focus on rehabilitation by providing motivation; 92.3% said that the user will feel safe in the virtual world, 66.7% of them agreed or totally agreed that it presents characteristics that may enhance the physical rehabilitation of lower limbs for amputees, 83.3% stated that it would promote the welfare of landmine victims, and 76.9% responded that the graphical interface and data report are useful for real-time assessment, and would be helpful for four interventional areas in all rehabilitation stages. In a second evaluation, using standardized surveys, five physical therapists and one lower limb amputee tried the Kina system as users. They filled out the System Usability Scale (SUS), the Physical Activity Enjoyment Scale (PACES), and the Game Experience Questionnaire (GEQ). The usability of the Kina system overall score was 69 (66, 79) out of 100, suggesting an acceptable though improvable usability. The overall PACES score of 110 (108, 112) out of 126 suggests that users enjoyed the game well. Finally, users indicated a positive effect with a good sense of immersion and smooth of gameplay during the tests, as indicated by the GEQ results. In summary, the evaluations showed that Exogames has the potential to be used as a virtual reality game for the physical and emotional rehabilitation of landmine victims.


  • Open Access

    Human-Robot Interaction Torque Estimation Methods for a Lower Limb Rehabilitation Robotic System with Uncertainties

    by Juan C. Yepes, Santiago Rúa, Marisol Osorio, Vera Z. Pérez, Jaime A. Moreno, Adel Al-Jumaily, Manuel J. Betancur

    Lower limb rehabilitation robot (LLRR) users, to successfully conduct isotonic exercises, require real-time feedback on the torque they exert on the robot to meet the goal of the treatment. Still, direct torque measuring is expensive, and indirect encoder-based estimation strategies, such as inverse dynamics (ID) and Nonlinear Disturbance Observers (NDO), are sensitive to Body Segment Inertial Parameters (BSIPs) uncertainties. We envision a way to minimize such parametric uncertainties. This paper proposes two human–robot interaction torque estimation methods: the Identified ID-based method (IID) and the Identified NDO-based method (INDO). Evaluating in simulation the proposal to apply, in each rehabilitation session, a sequential two-phase method: (1) An initial calibration phase will use an online parameter estimation to reduce sensitivity to BSIPs uncertainties. (2) The torque estimation phase uses the estimated parameters to obtain a better result. We conducted simulations under signal-to-noise ratio (SNR) = 40 dB and 20% BSIPs uncertainties. In addition, we compared the effectiveness with two of the best methods reported in the literature via simulation. Both proposed methods obtained the best Coefficient of Correlation, Mean Absolute Error, and Root Mean Squared Error compared to the benchmarks. Moreover, the IID and INDO fulfilled more than 72.2% and 88.9% of the requirements, respectively. In contrast, both methods reported in the literature only accomplish 27.8% and 33.3% of the requirements when using simulations under noise and BSIPs uncertainties. Therefore, this paper extends two methods reported in the literature and copes with BSIPs uncertainties without using additional sensors.


  • Observability analysis for a cooperative range-based navigation system that uses a rotating single beacon

    by Santiago Rúa, Rafael E. Vásquez, Naveen Crasta, Manuel J. Betancur, Antonio Pascoal


  • Open Access

    Myoelectric control algorithm for robot-assisted therapy: a hardware-in-the-loop simulation study

    by Juan C. Yepes, Mario A. Portela, Álvaro J. Saldarriaga, Vera Z. Pérez, Manuel J. Betancur

    A direct blow to the knee is one way to injure the anterior cruciate ligament (ACL), e.g., during a football or traffic accident. Robot-assisted therapy (RAT) rehabilitation, simulating regular walking, improves walking and balance abilities, and extensor strength after ACL reconstruction. However, there is a need to perform RAT during other phases of ACL injury rehabilitation before attempting an advanced exercise such as walking. This paper aims to propose a myoelectric control (MEC) algorithm for a robot-assisted rehabilitation system, “Nukawa”, to assist knee movement during these types of exercises, i.e., such as in active-assisted extension exercises. Surface electromyography (sEMG) signal processing algorithm was developed to detect the motion intention of the knee joint. The sEMG signal processing algorithm and the movement control algorithm, reported by the authors in a previous publication, were joined together as a hardware-in-the-loop simulation to create and test the MEC algorithm, instead of using the actual robot. An experimental protocol was conducted with 17 healthy subjects to acquire sEMG signals and their lower limb kinematics during 12 ACL rehabilitation exercises. The proposed motion intention algorithm detected the orientation of the intention 100% of the times for the extension and flexion exercises. Also, it detected in 94% and 59% of the cases the intensity of the movement intention in a comparable way to the maximum voluntary contraction (MVC) during extension exercises and flexion exercises, respectively. The maximum position mean absolute error was $$0.1^{\circ }$$ 0 . 1 ∘ , $$6.3^{\circ }$$ 6 . 3 ∘ , and $$0.3^{\circ }$$ 0 . 3 ∘ for the hip, knee, and ankle joints, respectively. The MEC algorithm detected the intensity of the movement intention, approximately, in a comparable way to the MVC and the orientation. Moreover, it requires no prior training or additional torque sensors. Also, it controls the speed of the knee joint of Nukawa to assist the knee movement, i.e., such as in active-assisted extension exercises.


  • Acclimatization model of an aerobic bioreactor for the treatment of toxic wastewater

    by Manuel J. Betancur, Fajith Martínez, Carlos Ocampo, Jaime A. Moreno, Germán Buitrón, Iván Moreno-Andrade


  • ACCLIMATION MODEL OF AN AEROBIC BIOREACTOR FOR THE TREATMENT OF TOXIC WASTEWATER

    by Fajith Martínez, Manuel J. Betancur, Jaime A. Moreno, Germán Buitrón, Iván Moreno-Andrade


  • Open Access

    CONTROL STRATEGIES FOR TREATING TOXIC WASTEWATER USING BIOREACTORS

    by Manuel J. Betancur, Jaime A. Moreno, Iván Moreno-Andrade, Germán Buitrón


  • Practical Optimal Control for Fed-Batch Bioreactors

    by Manuel J. Betancur, Jaime A. Moreno, Germán Buitrón