JYJuan C. Yepes

Juan C. Yepes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Juan C. Yepes has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Rehabilitation of Patients with Arthrogenic Muscular Inhibition in Pathologies of Knee Using Virtual Reality

    by Juan Pablo Flórez Fonnegra, Andrea Carolina Pino Prestan, Lucelly López López, Juan C. Yepes, Vera Z. Pérez

    Arthrogenic muscle inhibition (AMI) refers to muscular alterations that are generated, producing biomechanical motor control and movement problems, leading to deficiencies in strength and atrophy. Currently, there exist methods that involve virtual reality (VR) and have been well perceived by physiotherapists. The present research measured the potential benefits in terms of therapeutic adherence and speed of recovery, through a comparative analysis in a healthcare provider institution, in Medellín, Colombia, with and without the aid of VR. For this purpose, dynamometry, and surface electromyography (sEMG) signal acquisition tools were used. The treatment involved neuromodulation, ranges of motion and mobility work, strengthening and reintegration into movement, complemented with TENS, NMENS and therapeutic exercise, where the patient was expected to receive a satisfactory and faster adherence and recovery. A group of 15 people with AMI who include at least 15 min of VR per session in their treatment were compared with another group who received only the base treatment, i.e., the control group. Analyzing the variables individually, it is possible to affirm that VR, as a complement, statistically significantly improved the therapeutic adherence in 33.3% for CG and 37.5% for IG. Additionally, it increased strength with both legs, the symmetry between them, and decreased the level of pain and stiffness that is related to mobility.


  • Open Access

    Virtual Reality Game for Physical and Emotional Rehabilitation of Landmine Victims

    by Vera Z. Pérez, Juan C. Yepes, John F. Vargas, Juan C. Franco, Natalia I. Escobar, Leonardo Betancur, Juanita Sánchez, Manuel J. Betancur

    Landmine victims require an engaging and immersive rehabilitation process to maintain motivation and therapeutic adherence, such as virtual reality games. This paper proposes a virtual reality exercise game called Exogames, which works with Nukawa, a lower limb rehabilitation robot (LLRR). Together, they constitute the general Kina system. The design and development process of Exogames is reported, as well as the evaluation of its potential for physical and emotional rehabilitation. In an initial survey designed ad-hoc, 13 health professionals evaluated compliance with various requirements. They agreed that Exogames would help the user focus on rehabilitation by providing motivation; 92.3% said that the user will feel safe in the virtual world, 66.7% of them agreed or totally agreed that it presents characteristics that may enhance the physical rehabilitation of lower limbs for amputees, 83.3% stated that it would promote the welfare of landmine victims, and 76.9% responded that the graphical interface and data report are useful for real-time assessment, and would be helpful for four interventional areas in all rehabilitation stages. In a second evaluation, using standardized surveys, five physical therapists and one lower limb amputee tried the Kina system as users. They filled out the System Usability Scale (SUS), the Physical Activity Enjoyment Scale (PACES), and the Game Experience Questionnaire (GEQ). The usability of the Kina system overall score was 69 (66, 79) out of 100, suggesting an acceptable though improvable usability. The overall PACES score of 110 (108, 112) out of 126 suggests that users enjoyed the game well. Finally, users indicated a positive effect with a good sense of immersion and smooth of gameplay during the tests, as indicated by the GEQ results. In summary, the evaluations showed that Exogames has the potential to be used as a virtual reality game for the physical and emotional rehabilitation of landmine victims.


  • Open Access

    Human-Robot Interaction Torque Estimation Methods for a Lower Limb Rehabilitation Robotic System with Uncertainties

    by Juan C. Yepes, Santiago Rúa, Marisol Osorio, Vera Z. Pérez, Jaime A. Moreno, Adel Al-Jumaily, Manuel J. Betancur

    Lower limb rehabilitation robot (LLRR) users, to successfully conduct isotonic exercises, require real-time feedback on the torque they exert on the robot to meet the goal of the treatment. Still, direct torque measuring is expensive, and indirect encoder-based estimation strategies, such as inverse dynamics (ID) and Nonlinear Disturbance Observers (NDO), are sensitive to Body Segment Inertial Parameters (BSIPs) uncertainties. We envision a way to minimize such parametric uncertainties. This paper proposes two human–robot interaction torque estimation methods: the Identified ID-based method (IID) and the Identified NDO-based method (INDO). Evaluating in simulation the proposal to apply, in each rehabilitation session, a sequential two-phase method: (1) An initial calibration phase will use an online parameter estimation to reduce sensitivity to BSIPs uncertainties. (2) The torque estimation phase uses the estimated parameters to obtain a better result. We conducted simulations under signal-to-noise ratio (SNR) = 40 dB and 20% BSIPs uncertainties. In addition, we compared the effectiveness with two of the best methods reported in the literature via simulation. Both proposed methods obtained the best Coefficient of Correlation, Mean Absolute Error, and Root Mean Squared Error compared to the benchmarks. Moreover, the IID and INDO fulfilled more than 72.2% and 88.9% of the requirements, respectively. In contrast, both methods reported in the literature only accomplish 27.8% and 33.3% of the requirements when using simulations under noise and BSIPs uncertainties. Therefore, this paper extends two methods reported in the literature and copes with BSIPs uncertainties without using additional sensors.


  • Open Access

    Myoelectric control algorithm for robot-assisted therapy: a hardware-in-the-loop simulation study

    by Juan C. Yepes, Mario A. Portela, Álvaro J. Saldarriaga, Vera Z. Pérez, Manuel J. Betancur

    A direct blow to the knee is one way to injure the anterior cruciate ligament (ACL), e.g., during a football or traffic accident. Robot-assisted therapy (RAT) rehabilitation, simulating regular walking, improves walking and balance abilities, and extensor strength after ACL reconstruction. However, there is a need to perform RAT during other phases of ACL injury rehabilitation before attempting an advanced exercise such as walking. This paper aims to propose a myoelectric control (MEC) algorithm for a robot-assisted rehabilitation system, “Nukawa”, to assist knee movement during these types of exercises, i.e., such as in active-assisted extension exercises. Surface electromyography (sEMG) signal processing algorithm was developed to detect the motion intention of the knee joint. The sEMG signal processing algorithm and the movement control algorithm, reported by the authors in a previous publication, were joined together as a hardware-in-the-loop simulation to create and test the MEC algorithm, instead of using the actual robot. An experimental protocol was conducted with 17 healthy subjects to acquire sEMG signals and their lower limb kinematics during 12 ACL rehabilitation exercises. The proposed motion intention algorithm detected the orientation of the intention 100% of the times for the extension and flexion exercises. Also, it detected in 94% and 59% of the cases the intensity of the movement intention in a comparable way to the maximum voluntary contraction (MVC) during extension exercises and flexion exercises, respectively. The maximum position mean absolute error was $$0.1^{\circ }$$ 0 . 1 ∘ , $$6.3^{\circ }$$ 6 . 3 ∘ , and $$0.3^{\circ }$$ 0 . 3 ∘ for the hip, knee, and ankle joints, respectively. The MEC algorithm detected the intensity of the movement intention, approximately, in a comparable way to the MVC and the orientation. Moreover, it requires no prior training or additional torque sensors. Also, it controls the speed of the knee joint of Nukawa to assist the knee movement, i.e., such as in active-assisted extension exercises.


  • Online Simulation of Mechatronic Neural Interface Systems: Two Case-Studies

    by Samuel Bustamante, Juan C. Yepes, Vera Z. Pérez, Julio C. Correa, Manuel J. Betancur


  • Open Access

    A Hardware-in-the-loop Simulation Study of a Mechatronic System for Anterior Cruciate Ligament Injuries Rehabilitation

    by Juan C. Yepes, A. J. Saldarriaga, Jorge M. Vélez, Vera Z. Pérez, Manuel J. Betancur


  • Lower Limb Rehabilitation System Interfaced with a Videogame: A Potential Application for Landmine Victims

    by J. C. Yepes

    Worldwide there are approximately 3,308 records of landmine victims during a year. 67% of them suffered injuries which require physical rehabilitation. This paper presents a data acquisition system for landmine victims rehabilitation, interfaced with a videogame, which enables to interact with a racing game. The therapist can set the minimum speed required for the rehabilitation and analyze the forces and speed developed while pedaling. The conceptual development incorporates a commercial static bicycle, sensors to measure the pedaling force, an optic sensor to measure the speed, and command buttons to control the videogame. In order to evaluate the system, the sensors were characterized and tested, and a survey was conducted to 20 physiotherapists in order to evaluate the perception of ergonomics, safety and possible benefits of the data acquisition system for rehabilitation of landmine victims. 70%, 90% and 80% of the physiotherapists, respectively, assessed these characteristics as High level. Moreover, at least 85% of them agrees with nine possible benefits for rehabilitation of landmine explosion victim. Therefore, it is proposed that the data acquisition system can be used as a serious game that supports rehabilitation therapies of people with a prosthesis due to this cause.

  • Asimov: Android based mobile assistant for robotic teleoperation

    by J.J. Yepes, V.Z. Perez, M.J. Betancur, J.R. Martınez

    Teleoperated systems are becoming more present in medical applications. Its use goes from patients rehabilitation, medication storage and the management of biological hazardous materials, to minimally invasive surgery. This paper, presents the implementation of an Android based mobile application -Asimov- for remote control of an industrial robotic arm KUKA KR6, through WiFi technology. The application is a control tool for the robotic manipulator as an alternative to the Teach Pendant system provided by the manufacturer. The application functions and additional options are presented. Tests to nine people including health area personnel were performed, aiming to compare Asimov and Teach Pendant System. The evaluation of the results and the use of Wilcoxon signed rank test allowed to appreciate a better assessment for Asimov in the following criteria: ease of learning, usability, graphic interface and comfort. Significant differences in the last two benchmarks were found.

  • Implementation of an Android based teleoperation application for controlling a KUKA-KR6 robot by using sensor fusion

    by Juan J. Yepes, Jose R. Martinez, Vera Z. Perez

    Teleoperated systems have been used in diverse biomedical applications, from the rehabilitation of patients, the management of biological hazardous material and medication storage, to minimally invasive surgery. This paper, introduces an Android OS (operating system) based application that communicates with an industrial robot Kuka KR-6 through USB to Serial connection, to control it with the on-board accelerometers, and gyroscopes of a tablet or smartphone, intended to be used in telemedicine procedures. Arduino Uno microcontroller board, RS232 Shifter SMD and mobile device were used to develop this work. To evaluate this system a survey was done with engineering related users.