Narendra Bhadra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Narendra Bhadra has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Kevin L. Kilgore
Case Western Reserve University
3 shared publications J. Thomas Mortimer
Case Western Reserve University
2 shared publicationsD. Michael Ackermann
MetroHealth Medical Center, 2500 MetroHealth Drive, Cleveland, OH 44109, USA
1 shared publicationEmily L. Foldes
Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA
1 shared publicationFred W. Montague
Case Western Reserve University, Cleveland
1 shared publicationGraham H. Creasey
Metro Health Medical Center and the V.A. Medical Center, Cleveland, Ohio
1 shared publication
Latest Publications
- 11 September 2015
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 54 (1) , 191-203
Characterization of high capacitance electrodes for the application of direct current electrical nerve block
Direct current (DC) can briefly produce a reversible nerve conduction block in acute experiments. However, irreversible reactions at the electrode–tissue interface have prevented its use in both acute and chronic settings. A high capacitance material (platinum black) using a charge-balanced waveform was evaluated to determine whether brief DC block (13 s) could be achieved repeatedly (>100 cycles) without causing acute irreversible reduction in nerve conduction. Electrochemical techniques were used to characterize the electrodes to determine appropriate waveform parameters. In vivo experiments on DC motor conduction block of the rat sciatic nerve were performed to characterize the acute neural response to this novel nerve block system. Complete nerve motor conduction block of the rat sciatic nerve was possible in all experiments, with the block threshold ranging from −0.15 to −3.0 mA. DC pulses were applied for 100 cycles with no nerve conduction reduction in four of the six platinum black electrodes tested. However, two of the six electrodes exhibited irreversible conduction degradation despite charge delivery that was within the initial Q (capacitance) value of the electrode. Degradation of material properties occurred in all experiments, pointing to a possible cause of the reduction in nerve conduction in some platinum black experiments .
- 11 September 2015
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 54 (1) , 191-203
Characterization of high capacitance electrodes for the application of direct current electrical nerve block
Direct current (DC) can briefly produce a reversible nerve conduction block in acute experiments. However, irreversible reactions at the electrode–tissue interface have prevented its use in both acute and chronic settings. A high capacitance material (platinum black) using a charge-balanced waveform was evaluated to determine whether brief DC block (13 s) could be achieved repeatedly (>100 cycles) without causing acute irreversible reduction in nerve conduction. Electrochemical techniques were used to characterize the electrodes to determine appropriate waveform parameters. In vivo experiments on DC motor conduction block of the rat sciatic nerve were performed to characterize the acute neural response to this novel nerve block system. Complete nerve motor conduction block of the rat sciatic nerve was possible in all experiments, with the block threshold ranging from −0.15 to −3.0 mA. DC pulses were applied for 100 cycles with no nerve conduction reduction in four of the six platinum black electrodes tested. However, two of the six electrodes exhibited irreversible conduction degradation despite charge delivery that was within the initial Q (capacitance) value of the electrode. Degradation of material properties occurred in all experiments, pointing to a possible cause of the reduction in nerve conduction in some platinum black experiments .
- 1 March 2011
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 196 (1) , 31-37
Design, fabrication and evaluation of a conforming circumpolar peripheral nerve cuff electrode for acute experimental use
- 1 March 2011
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 196 (1) , 31-37
Design, fabrication and evaluation of a conforming circumpolar peripheral nerve cuff electrode for acute experimental use
- 27 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 19 (1) , 45-53
Design and Testing of an Advanced Implantable Neuroprosthesis With Myoelectric Control
An implantable stimulator-telemeter (IST-12) was developed for applications in neuroprosthetic restoration of limb function in paralyzed individuals. The IST-12 provides 12 stimulation channels and two myoelectric signal (MES) channels. The MES circuitry includes a two-channel multiplexer, preamplifier, variable gain amplifier/bandpass filter, full-wave rectifier, and bin integrator. Power and control signals are transmitted from an external control unit to the IST-12 through an inductive link. Recorded MES signals are telemetered back to the external control unit through the same inductive link. Following bench testing, one device was implanted chronically in a dog for 15 months and evaluated. Conditions were identified in which MES could be recorded with minimal stimulus artifact. The ability to record MES in the presence of stimulation was verified, confirming the potential of the IST-12 to be used as a myoelectric controlled neuroprosthesis.
- 27 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 19 (1) , 45-53
Design and Testing of an Advanced Implantable Neuroprosthesis With Myoelectric Control
An implantable stimulator-telemeter (IST-12) was developed for applications in neuroprosthetic restoration of limb function in paralyzed individuals. The IST-12 provides 12 stimulation channels and two myoelectric signal (MES) channels. The MES circuitry includes a two-channel multiplexer, preamplifier, variable gain amplifier/bandpass filter, full-wave rectifier, and bin integrator. Power and control signals are transmitted from an external control unit to the IST-12 through an inductive link. Recorded MES signals are telemetered back to the external control unit through the same inductive link. Following bench testing, one device was implanted chronically in a dog for 15 months and evaluated. Conditions were identified in which MES could be recorded with minimal stimulus artifact. The ability to record MES in the presence of stimulation was verified, confirming the potential of the IST-12 to be used as a myoelectric controlled neuroprosthesis.
- 12 May 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 34 (6) , 1042-1050
Extraction Force and Tissue Change During Removal of a Tined Intramuscular Electrode from Rat Gastrocnemius
Many electrical stimulation protocols employ intramuscular electrodes for the activation of targeted muscles. Electrode displacement from the initial implant site can result in degradation of optimal stimulus parameters. Electrodes with tined tips were developed to reduce electrode migration. In the study reported here, intramuscular electrodes with polypropylene tines at the tip were implanted aseptically in the gastrocnemii of adult rats. Test electrodes were explanted immediately following implant in one group and after periods of 1, 3, 7, 14 and 28 days in others. Force as a function of displacement was recorded during removal of the electrodes. Analysis of the results showed that the electrodes were most vulnerable to movement during the first five days. Between 5 and 7 days after implantation there was significant increase in the force required to dislodge the electrode tip. Histology of muscles from which electrodes had been explanted did not show any increase in the area showing tissue changes as compared to control muscles in which the electrode remained in situ. These results indicated that electrode removal caused disruption of encapsulation tissues, with the surrounding muscle mainly unaffected by the explant process.
- 12 May 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 34 (6) , 1042-1050
Extraction Force and Tissue Change During Removal of a Tined Intramuscular Electrode from Rat Gastrocnemius
Many electrical stimulation protocols employ intramuscular electrodes for the activation of targeted muscles. Electrode displacement from the initial implant site can result in degradation of optimal stimulus parameters. Electrodes with tined tips were developed to reduce electrode migration. In the study reported here, intramuscular electrodes with polypropylene tines at the tip were implanted aseptically in the gastrocnemii of adult rats. Test electrodes were explanted immediately following implant in one group and after periods of 1, 3, 7, 14 and 28 days in others. Force as a function of displacement was recorded during removal of the electrodes. Analysis of the results showed that the electrodes were most vulnerable to movement during the first five days. Between 5 and 7 days after implantation there was significant increase in the force required to dislodge the electrode tip. Histology of muscles from which electrodes had been explanted did not show any increase in the area showing tissue changes as compared to control muscles in which the electrode remained in situ. These results indicated that electrode removal caused disruption of encapsulation tissues, with the surrounding muscle mainly unaffected by the explant process.
- 14 October 2005
- Published by Wiley in Neurourology and Urodynamics
- Vol. 25 (2) , 185-193
Selective activation of the sacral anterior roots for induction of bladder voiding
Aim We investigated the efficacy of selective activation of the smaller diameter axons in the sacral anterior roots for electrically induced bladder voiding. Materials and Methods Acute experiments were conducted in five adult dogs. The anterior sacral roots S2 and S3 were implanted bilaterally with tripolar electrodes. Pressures were recorded from the bladder and from the proximal urethra and the external urethral sphincter. A detector and flow meter monitored fluid flow. A complete sacral dorsal rhizotomy was carried out. The effects of two types of pulse trains at 20 Hz were compared; quasitrapezoidal pulses (500 µsec with 500 µsec exponential decay) and interrupted rectangular (100 µsec, 2 sec on/2 sec off). Before rhizotomy, rectangular pulse trains (100 µsec) to activate all fibers were also applied. The experimental design was block randomized before and after rhizotomy. Results Quasitrapezoidal pulses showed block of sphincter activation with average minimum current for maximum suppression of 1.37 mA. All pulse types evoked average bladder pressures above the basal sphincter closure pressure. The pressure patterns in the proximal urethra closely followed the bladder pressures. Before dorsal rhizotomy, stimulation evoked a superadded increase in sphincter pressures with slow rise time. After rhizotomy, the sphincter pressure patterns followed the bladder pressures during selective activation and voiding occurred during stimulation with quasitrapezoidal trains and in between bursts with interrupted rectangular stimulation. Conclusions Selective activation of sacral ventral roots combined with dorsal rhizotomy may provide a viable means of low-pressure continuous voiding in neurological impairment. Neurourol. Urdynam.
- 14 October 2005
- Published by Wiley in Neurourology and Urodynamics
- Vol. 25 (2) , 185-193
Selective activation of the sacral anterior roots for induction of bladder voiding
Aim We investigated the efficacy of selective activation of the smaller diameter axons in the sacral anterior roots for electrically induced bladder voiding. Materials and Methods Acute experiments were conducted in five adult dogs. The anterior sacral roots S2 and S3 were implanted bilaterally with tripolar electrodes. Pressures were recorded from the bladder and from the proximal urethra and the external urethral sphincter. A detector and flow meter monitored fluid flow. A complete sacral dorsal rhizotomy was carried out. The effects of two types of pulse trains at 20 Hz were compared; quasitrapezoidal pulses (500 µsec with 500 µsec exponential decay) and interrupted rectangular (100 µsec, 2 sec on/2 sec off). Before rhizotomy, rectangular pulse trains (100 µsec) to activate all fibers were also applied. The experimental design was block randomized before and after rhizotomy. Results Quasitrapezoidal pulses showed block of sphincter activation with average minimum current for maximum suppression of 1.37 mA. All pulse types evoked average bladder pressures above the basal sphincter closure pressure. The pressure patterns in the proximal urethra closely followed the bladder pressures. Before dorsal rhizotomy, stimulation evoked a superadded increase in sphincter pressures with slow rise time. After rhizotomy, the sphincter pressure patterns followed the bladder pressures during selective activation and voiding occurred during stimulation with quasitrapezoidal trains and in between bursts with interrupted rectangular stimulation. Conclusions Selective activation of sacral ventral roots combined with dorsal rhizotomy may provide a viable means of low-pressure continuous voiding in neurological impairment. Neurourol. Urdynam.