Bart Vandenberghe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bart Vandenberghe has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Reinhilde Jacobs
OMFS-IMPATH Research Group, Department of Imaging and Pathology, Catholic University Leuven, Leuven, Belgium
6 shared publications - Hilde Bosmans
Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
3 shared publications Jie Yang
Temple University School of Dentistry
2 shared publicationsAsti Sutanto
Katholieke Universiteit Leuven
1 shared publicationE Dhoore
Research and Development Department, Materialise Dental NV, Leuven, Belgium
1 shared publicationJ Hostens
Research and Development and Applications, Skyscan NV, Kontich, Belgium
1 shared publication
Latest Publications
- 1 September 2012
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 41 (6) , 466-474
The influence of exposure parameters on jawbone model accuracy using cone beam CT and multislice CT
Objective: The main purpose of this study was to investigate the influence of exposure parameters on jawbone model accuracy when using cone beam CT (CBCT) and multislice CT (MSCT). Methods: A lower and an upper edentulous human cadaver jaw were scanned using micro-CT (Skyscan 1173 high energy spiral scan micro-CT; Skyscan NV, Kontich, Belgium) at 35 μm to serve as true reference. The in vitro samples were exposed using six CBCT units and one MSCT system. CBCT exposure protocols were chosen according to clinically available settings. The variables were kilovoltage, milliamperage, voxel size and/or scan time. Image segmentation was based on local thresholds using profile lines. The resulting jawbone segmentations were registered with the reference and image processing was done to internally fill the segmentations. A point-based distance calculation was performed between the three-dimensional objects and reference scans and deviation percentages were calculated for 2 mm, 1 mm and 0.5 mm intervals. Results: A...
- 1 September 2012
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 41 (6) , 466-474
The influence of exposure parameters on jawbone model accuracy using cone beam CT and multislice CT
Objective: The main purpose of this study was to investigate the influence of exposure parameters on jawbone model accuracy when using cone beam CT (CBCT) and multislice CT (MSCT). Methods: A lower and an upper edentulous human cadaver jaw were scanned using micro-CT (Skyscan 1173 high energy spiral scan micro-CT; Skyscan NV, Kontich, Belgium) at 35 μm to serve as true reference. The in vitro samples were exposed using six CBCT units and one MSCT system. CBCT exposure protocols were chosen according to clinically available settings. The variables were kilovoltage, milliamperage, voxel size and/or scan time. Image segmentation was based on local thresholds using profile lines. The resulting jawbone segmentations were registered with the reference and image processing was done to internally fill the segmentations. A point-based distance calculation was performed between the three-dimensional objects and reference scans and deviation percentages were calculated for 2 mm, 1 mm and 0.5 mm intervals. Results: A...
- 11 June 2010
- Published by Springer Nature in European Radiology
- Vol. 20 (11) , 2637-2655
Modern dental imaging: a review of the current technology and clinical applications in dental practice
A review of modern imaging techniques commonly used in dental practice and their clinical applications is presented. The current dental examinations consist of intraoral imaging with digital indirect and direct receptors, while extraoral imaging is divided into traditional tomographic/panoramic imaging and the more recently introduced cone beam computed tomography. Applications, limitations and current trends of these dental “in-office” radiographic techniques are discussed.
- 11 June 2010
- Published by Springer Nature in European Radiology
- Vol. 20 (11) , 2637-2655
Modern dental imaging: a review of the current technology and clinical applications in dental practice
A review of modern imaging techniques commonly used in dental practice and their clinical applications is presented. The current dental examinations consist of intraoral imaging with digital indirect and direct receptors, while extraoral imaging is divided into traditional tomographic/panoramic imaging and the more recently introduced cone beam computed tomography. Applications, limitations and current trends of these dental “in-office” radiographic techniques are discussed.
- 12 May 2010
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 15 (4) , 551-562
A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: The influence of intra-oral image receptor on periodontal measurements
The aim of the study was to determine the image receptors' influence on exposure levels, image accuracy, and quality for periodontal diagnosis. Periodontal defects from cadaver specimens were imaged using two intra-oral conventional films (E-, F/E-speed), four indirect receptors (Digora 8 bit, Vistascan 12 bit with/without filter, Vistascan 16 bit), and two solid-state sensors (Sigma 12 bit, VistaRay 14 bit) at rising exposure (20–160 ms). Three observers assessed the standardized radiographs for alveolar bone measurements (1,732, 31 sites) and for subjective rating of lamina dura, contrast, trabecularization, crater, and furcation involvements. The measurements were compared to the gold standard. For the imaging plates, highest measurement accuracy was found with Vistascan 16 bit (100% within 0.5 mm) and for solid-state sensors with VistaRay 14 bit (100%, 0.5 mm), although the latter are mostly not significantly different. Higher contrast resolution imaging plates require up to 50% less exposure time, but for solid-state sensors, the dose remains unchanged. For the latter, a higher bit depth does seem to provide more accurate depiction of the alveolar crest, counteracting blooming artifacts. The use of a dedicated periodontal filter contributes to higher accuracy at all exposure times (p < 0.05–0.0001). Accuracy of periodontal diagnosis increases with higher contrast resolution. Digital exposure levels are thus dependent of image receptor as well as X-ray generator.
- 12 May 2010
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 15 (4) , 551-562
A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: The influence of intra-oral image receptor on periodontal measurements
The aim of the study was to determine the image receptors' influence on exposure levels, image accuracy, and quality for periodontal diagnosis. Periodontal defects from cadaver specimens were imaged using two intra-oral conventional films (E-, F/E-speed), four indirect receptors (Digora 8 bit, Vistascan 12 bit with/without filter, Vistascan 16 bit), and two solid-state sensors (Sigma 12 bit, VistaRay 14 bit) at rising exposure (20–160 ms). Three observers assessed the standardized radiographs for alveolar bone measurements (1,732, 31 sites) and for subjective rating of lamina dura, contrast, trabecularization, crater, and furcation involvements. The measurements were compared to the gold standard. For the imaging plates, highest measurement accuracy was found with Vistascan 16 bit (100% within 0.5 mm) and for solid-state sensors with VistaRay 14 bit (100%, 0.5 mm), although the latter are mostly not significantly different. Higher contrast resolution imaging plates require up to 50% less exposure time, but for solid-state sensors, the dose remains unchanged. For the latter, a higher bit depth does seem to provide more accurate depiction of the alveolar crest, counteracting blooming artifacts. The use of a dedicated periodontal filter contributes to higher accuracy at all exposure times (p < 0.05–0.0001). Accuracy of periodontal diagnosis increases with higher contrast resolution. Digital exposure levels are thus dependent of image receptor as well as X-ray generator.
- 5 May 2010
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 15 (4) , 537-549
A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. PART 1: The influence of X-ray generator on periodontal measurements using conventional and digital receptors
The aim of this study was the determination of image accuracy and quality for periodontal diagnosis using various X-ray generators with conventional and digital radiographs. Thirty-one in vitro periodontal defects were evaluated on intraoral conventional (E-, F/E-speed) and digital images (three indirect, two direct sensors). Standardised radiographs were made with an alternating current (AC), a high-frequency (HF) and a direct current (DC) X-ray unit at rising exposure times (20–160 ms with 20-ms interval) with a constant kV of 70. Three observers assessed bone levels for comparison to the gold standard. Lamina dura, contrast, trabecularisation, crater and furcation involvements were evaluated. Irrespective X-ray generator-type, measurement deviations increased at higher exposure times for solid-state, but decreased for photostimulable storage phosphor (PSP) systems. Accuracy for HF or DC was significantly higher than AC (p < 0.0001), especially at low exposure times. At 0.5- to 1-mm clinical deviation, 27–53% and 32–55% dose savings were demonstrated when using HF or DC generators compared to AC, but only for PSP. No savings were found for solid-state sensors, indicating their higher sensitivity. The use of digital sensors compared to film allowed 15–90% dose savings using the AC tube, whilst solid-state sensors allowed approximately 50% savings compared to PSP, depending on tube type and threshold level.. Accuracy of periodontal diagnosis increases when using HF or DC generators and/or digital receptors with adequate diagnostic information at lower exposure times.
- 5 May 2010
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 15 (4) , 537-549
A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. PART 1: The influence of X-ray generator on periodontal measurements using conventional and digital receptors
The aim of this study was the determination of image accuracy and quality for periodontal diagnosis using various X-ray generators with conventional and digital radiographs. Thirty-one in vitro periodontal defects were evaluated on intraoral conventional (E-, F/E-speed) and digital images (three indirect, two direct sensors). Standardised radiographs were made with an alternating current (AC), a high-frequency (HF) and a direct current (DC) X-ray unit at rising exposure times (20–160 ms with 20-ms interval) with a constant kV of 70. Three observers assessed bone levels for comparison to the gold standard. Lamina dura, contrast, trabecularisation, crater and furcation involvements were evaluated. Irrespective X-ray generator-type, measurement deviations increased at higher exposure times for solid-state, but decreased for photostimulable storage phosphor (PSP) systems. Accuracy for HF or DC was significantly higher than AC (p < 0.0001), especially at low exposure times. At 0.5- to 1-mm clinical deviation, 27–53% and 32–55% dose savings were demonstrated when using HF or DC generators compared to AC, but only for PSP. No savings were found for solid-state sensors, indicating their higher sensitivity. The use of digital sensors compared to film allowed 15–90% dose savings using the AC tube, whilst solid-state sensors allowed approximately 50% savings compared to PSP, depending on tube type and threshold level.. Accuracy of periodontal diagnosis increases when using HF or DC generators and/or digital receptors with adequate diagnostic information at lower exposure times.
- Open Access
- 19 January 2010
- Published by Stilus Optimus in Journal of Oral and Maxillofacial Research
- Vol. 1 (1)
The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
- 19 January 2010
- Published by Stilus Optimus in Journal of Oral and Maxillofacial Research
- Vol. 1 (1)
Open AccessThe Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
- Open Access
- 18 January 2010
- Published by Stilus Optimus in Journal of Oral and Maxillofacial Research
- Vol. 1 (1)
The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
- 18 January 2010
- Published by Stilus Optimus in Journal of Oral and Maxillofacial Research
- Vol. 1 (1)
Open AccessThe Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
- 19 May 2009
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 14 (2) , 223-231
The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics
To assess the reliability of high resolution intra-oral photostimulable storage phosphor (PSP) and complementary metal-oxide semiconductor (CMOS) imaging systems for working length (WL) assessment of small K-files in narrow and curved root canals. Eleven narrow and curved canals from extracted molars were used as pre-test for sample-size calculation. Nineteen canals from four cadavers were used for endodontic length assessment in the final study. Small K-files (ISO size 6, 8, and 10) were introduced into the canals at prepared length. Digital intra-oral radiographs were obtained using high-resolution Vistascan® PSP plates and Sigma M CMOS active pixel sensor with a DC X-ray tube at 70 kV, 7 mA, and 0.16 s. Both image series were assessed with and without use of a dedicated endodontic filter. Three observers measured WLs for comparison to the gold standards of a digital millimeter ruler. Multiple regression analysis of the dependent measurements revealed no significant influence of imaging sensor (PSP or CMOS, p = 0.34) and image processing (p = 0.97). For ISO file size, however, there was a significant difference (p = 0.08) at a level of 10%. Observers mostly underestimated lengths using PSP but overestimated them on CMOS. Almost all radiographic measurements (96–98%) were within 2-mm deviation, while 71% to 82% deviated within 1 mm. Dedicated filtering and sensor type did not influence the outcome of WL determination of small file sizes when using high-resolution imaging sensors. WL determination with ISO file 6 did show a significant difference compared to ISO 8 and 10 but mostly for deviations <1.5 mm.
- 19 May 2009
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 14 (2) , 223-231
The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics
To assess the reliability of high resolution intra-oral photostimulable storage phosphor (PSP) and complementary metal-oxide semiconductor (CMOS) imaging systems for working length (WL) assessment of small K-files in narrow and curved root canals. Eleven narrow and curved canals from extracted molars were used as pre-test for sample-size calculation. Nineteen canals from four cadavers were used for endodontic length assessment in the final study. Small K-files (ISO size 6, 8, and 10) were introduced into the canals at prepared length. Digital intra-oral radiographs were obtained using high-resolution Vistascan® PSP plates and Sigma M CMOS active pixel sensor with a DC X-ray tube at 70 kV, 7 mA, and 0.16 s. Both image series were assessed with and without use of a dedicated endodontic filter. Three observers measured WLs for comparison to the gold standards of a digital millimeter ruler. Multiple regression analysis of the dependent measurements revealed no significant influence of imaging sensor (PSP or CMOS, p = 0.34) and image processing (p = 0.97). For ISO file size, however, there was a significant difference (p = 0.08) at a level of 10%. Observers mostly underestimated lengths using PSP but overestimated them on CMOS. Almost all radiographic measurements (96–98%) were within 2-mm deviation, while 71% to 82% deviated within 1 mm. Dedicated filtering and sensor type did not influence the outcome of WL determination of small file sizes when using high-resolution imaging sensors. WL determination with ISO file 6 did show a significant difference compared to ISO 8 and 10 but mostly for deviations <1.5 mm.