ABAbdelmalek Bermad

Abdelmalek Bermad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abdelmalek Bermad has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Applications of Radial-Basis Function and Generalized Regression Neural Networks for Modeling of Coagulant Dosage in a Drinking Water-Treatment Plant: Comparative Study

    by Salim Heddam, Abdelmalek Bermad, Noureddine Dechemi

    The coagulation process, which involves many complex physical and chemical phenomena, is one of the most important stages in water-treatment plants. The coagulant dosage rate is nonlinearly correlated to raw water characteristics such as turbidity, conductivity, and pH. The coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. The coagulant dosage has typically been determined through the jar test, which requires a long experiment time in a field-water-treatment plant. Modeling can be used to overcome these limitations. In this study, a model for the approximation of coagulant dosage rates in water-treatment plants in Algeria has been developed using artificial neural network (ANN) techniques. Two different ANN techniques, the generalized regression neural network (GRNN) and the radial-basis function neural network (RBFNN), were tested for this purpose. The trained GRNN model outperforms the corresponding RBFNN model.


  • ANFIS-based modelling for coagulant dosage in drinking water treatment plant: a case study

    by Salim Heddam, Abdelmalek Bermad, Noureddine Dechemi

    Coagulation is the most important stage in drinking water treatment processes for the maintenance of acceptable treated water quality and economic plant operation, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw water characteristics such as turbidity, conductivity, pH, temperature, etc. As such, coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. Traditionally, jar tests are used to determine the optimum coagulant dosage. However, this is expensive and time-consuming and does not enable responses to changes in raw water quality in real time. Modelling can be used to overcome these limitations. In this study, an Adaptive Neuro-Fuzzy Inference System (ANFIS) was used for modelling of coagulant dosage in drinking water treatment plant of Boudouaou, Algeria. Six on-line variables of raw water quality including turbidity, conductivity, temperature, dissolved oxygen, ultraviolet absorbance, and the pH of water, and alum dosage were used to build the coagulant dosage model. Two ANFIS-based Neuro-fuzzy systems are presented. The two Neuro-fuzzy systems are: (1) grid partition-based fuzzy inference system (FIS), named ANFIS-GRID, and (2) subtractive clustering based (FIS), named ANFIS-SUB. The low root mean square error and high correlation coefficient values were obtained with ANFIS-SUB method of a first-order Sugeno type inference. This study demonstrates that ANFIS-SUB outperforms ANFIS-GRID due to its simplicity in parameter selection and its fitness in the target problem.