Warren S. Grundfest
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Warren S. Grundfest has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
- Martin O. Culjat
Farus, LLC
14 shared publications - Elliott R. Brown
Wright State University, Dayton, OH, USA
7 shared publications - Zachary D. Taylor
Aalto University
7 shared publications - Erik Dutson
Department of Surgery, UCLA Section of Minimally Invasive and Bariatric Surgery, David Geffen School of Medicine at University of California, Los Angeles, USA
6 shared publications Rahul S Singh
6 shared publications- James W. Bisley
Department of Neurobiology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
5 shared publications
Latest Publications
- Open Access
- 22 November 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-9
Effects of Low Intensity Focused Ultrasound on Liposomes Containing Channel proteins
The ability to reversibly and non-invasively modulate region-specific brain activity in vivo suggests Low Intensity Focused Ultrasound (LIFU) as potential therapeutics for neurological dysfunctions such as epilepsy and Parkinson’s disease. While in vivo studies provide evidence of the bioeffects of LIFU on neuronal activity, they merely hint at potential mechanisms but do not fully explain how this technology achieves these effects. One potential hypothesis is that LIFU produces local membrane depolarization by mechanically perturbing the neuronal cell membrane, or activating channels or other proteins embedded in the membrane. Proteins that sense mechanical perturbations of the membrane, such as those gated by membrane tension, are prime candidates for activating in response to LIFU and thus leading to the neurological responses that have been measured. Here we use the bacterial mechanosensitive channel MscL, which has been purified and reconstituted in liposomes, to determine how LIFU may affect the activation of this membrane-tension gated channel. Two bacterial voltage-gated channels, KvAP and NaK2K F92A channels were also studied. Surprisingly, the results suggest that ultrasound modulation and membrane perturbation does not induce channel gating, but rather induces pore formation at the membrane protein-lipid interface. However, in vesicles with high MscL mechanosensitive channel concentrations, apparent decreases in pore formation are observed, suggesting that this membrane-tension-sensitive protein may serve to increase the elasticity of the membrane, presumably because of expansion of the channel in the plane of the membrane independent of channel gating.
- 22 November 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-9
Open AccessEffects of Low Intensity Focused Ultrasound on Liposomes Containing Channel proteins
The ability to reversibly and non-invasively modulate region-specific brain activity in vivo suggests Low Intensity Focused Ultrasound (LIFU) as potential therapeutics for neurological dysfunctions such as epilepsy and Parkinson’s disease. While in vivo studies provide evidence of the bioeffects of LIFU on neuronal activity, they merely hint at potential mechanisms but do not fully explain how this technology achieves these effects. One potential hypothesis is that LIFU produces local membrane depolarization by mechanically perturbing the neuronal cell membrane, or activating channels or other proteins embedded in the membrane. Proteins that sense mechanical perturbations of the membrane, such as those gated by membrane tension, are prime candidates for activating in response to LIFU and thus leading to the neurological responses that have been measured. Here we use the bacterial mechanosensitive channel MscL, which has been purified and reconstituted in liposomes, to determine how LIFU may affect the activation of this membrane-tension gated channel. Two bacterial voltage-gated channels, KvAP and NaK2K F92A channels were also studied. Surprisingly, the results suggest that ultrasound modulation and membrane perturbation does not induce channel gating, but rather induces pore formation at the membrane protein-lipid interface. However, in vesicles with high MscL mechanosensitive channel concentrations, apparent decreases in pore formation are observed, suggesting that this membrane-tension-sensitive protein may serve to increase the elasticity of the membrane, presumably because of expansion of the channel in the plane of the membrane independent of channel gating.
- 10 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (4) , 1165-1171
Suture Breakage Warning System for Robotic Surgery
As robotic surgery has increased in popularity, the lack of haptic feedback has become a growing issue due to the application of excessive forces that may lead to clinical problems such as intraoperative and postoperative suture breakage. Previous suture breakage warning systems have largely depended on visual and/or auditory feedback modalities, which have been shown to increase cognitive load and reduce operator performance. This work catalogues a new sensing technology and haptic feedback system (HFS) that can reduce instances of suture failure without negatively impacting performance outcomes including knot quality. Suture breakage is common in knot-tying as the pulling motion introduces prominent shear forces. A shear sensor mountable on the da Vinci robotic surgical system's Cadiere grasper detects forces that correlate to the suture's internal tension. HFS then provides vibration feedback to the operator as forces near a particular material's failure load. To validate the system, subjects tightened a total of four knots, two with the Haptic Feedback System (HFS) and two without feedback. The number of suture breakages were recorded and knot fidelity was evaluated by measuring knot slippage. Results showed that instances of suture failure were significantly reduced when HFS was enabled (p = 0.0078). Notably, knots tied with HFS also showed improved quality compared to those tied without feedback (p = 0.010). The results highlight the value of HFS in improving robotic procedure outcomes by reducing instances of suture failures, producing better knots, and reducing the need for corrective measures.
- 10 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (4) , 1165-1171
Suture Breakage Warning System for Robotic Surgery
As robotic surgery has increased in popularity, the lack of haptic feedback has become a growing issue due to the application of excessive forces that may lead to clinical problems such as intraoperative and postoperative suture breakage. Previous suture breakage warning systems have largely depended on visual and/or auditory feedback modalities, which have been shown to increase cognitive load and reduce operator performance. This work catalogues a new sensing technology and haptic feedback system (HFS) that can reduce instances of suture failure without negatively impacting performance outcomes including knot quality. Suture breakage is common in knot-tying as the pulling motion introduces prominent shear forces. A shear sensor mountable on the da Vinci robotic surgical system's Cadiere grasper detects forces that correlate to the suture's internal tension. HFS then provides vibration feedback to the operator as forces near a particular material's failure load. To validate the system, subjects tightened a total of four knots, two with the Haptic Feedback System (HFS) and two without feedback. The number of suture breakages were recorded and knot fidelity was evaluated by measuring knot slippage. Results showed that instances of suture failure were significantly reduced when HFS was enabled (p = 0.0078). Notably, knots tied with HFS also showed improved quality compared to those tied without feedback (p = 0.010). The results highlight the value of HFS in improving robotic procedure outcomes by reducing instances of suture failures, producing better knots, and reducing the need for corrective measures.
- 1 September 2018
- Vol. 91 (3) , 215-223
Vibroacoustographic System for Tumor Identification
Oral and head and neck squamous cell carcinoma (OSCC dagger) is the sixth most common cancer worldwide. The primary management of OSCC relies on complete surgical resection of the tumor. Margin-free resection, however, is difficult given the devastating effects of aggressive surgery. Currently, surgeons determine where cuts are made by palpating edges of the tumor. Accuracy varies based on the surgeon's experience, the location and type of tumor, and the risk of damage to adjacent structures limiting resection margins. To fulfill this surgical need, we contrast tissue regions by identifying disparities in viscoelasticity by mixing two ultrasonic beams to produce a beat frequency, a technique termed vibroacoustography (VA). In our system, an extended focal length of the acoustic stress field yields surgeons' high resolution to detect focal lesions in deep tissue. VA offers 3D imaging by focusing its imaging plane at multiple axial cross-sections within tissue. Our efforts culminate in production of a mobile VA system generating image contrast between normal and abnormal tissue in minutes. We model the spatial direction of the generated acoustic field and generate images from tissue-mimicking phantoms and ex vivo specimens with squamous cell carcinoma of the tongue to qualitatively demonstrate the functionality of our system. These preliminary results warrant additional validation as we continue clinical trials of ex vivo tissue. This tool may prove especially useful for finding tumors that are deep within tissue and often missed by surgeons. The complete primary resection of tumors may reduce recurrence and ultimately improve patient outcomes.
- 1 September 2018
- Vol. 91 (3) , 215-223
Vibroacoustographic System for Tumor Identification
Oral and head and neck squamous cell carcinoma (OSCC dagger) is the sixth most common cancer worldwide. The primary management of OSCC relies on complete surgical resection of the tumor. Margin-free resection, however, is difficult given the devastating effects of aggressive surgery. Currently, surgeons determine where cuts are made by palpating edges of the tumor. Accuracy varies based on the surgeon's experience, the location and type of tumor, and the risk of damage to adjacent structures limiting resection margins. To fulfill this surgical need, we contrast tissue regions by identifying disparities in viscoelasticity by mixing two ultrasonic beams to produce a beat frequency, a technique termed vibroacoustography (VA). In our system, an extended focal length of the acoustic stress field yields surgeons' high resolution to detect focal lesions in deep tissue. VA offers 3D imaging by focusing its imaging plane at multiple axial cross-sections within tissue. Our efforts culminate in production of a mobile VA system generating image contrast between normal and abnormal tissue in minutes. We model the spatial direction of the generated acoustic field and generate images from tissue-mimicking phantoms and ex vivo specimens with squamous cell carcinoma of the tongue to qualitatively demonstrate the functionality of our system. These preliminary results warrant additional validation as we continue clinical trials of ex vivo tissue. This tool may prove especially useful for finding tumors that are deep within tissue and often missed by surgeons. The complete primary resection of tumors may reduce recurrence and ultimately improve patient outcomes.
- 19 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (1) , 14-22
Registration Accuracy of Patient-Specific, Three-Dimensional-Printed Prostate Molds for Correlating Pathology With Magnetic Resonance Imaging
Objective: This investigation was performed to evaluate the registration accuracy between magnetic resonance imaging (MRI) and pathology using three-dimensional (3D) printed molds. Methods: Tissue-mimicking prostate phantoms were manufactured with embedded fiducials. The fiducials were used to measure and compare target registration error (TRE) between phantoms that were sliced by hand versus phantoms sliced within 3D-printed molds. Subsequently, 10 radical prostatectomy specimens were placed inside molds, scanned with MRI, and then sliced. The ex vivo scan was used to assess the true location of whole mount (WM) slides relative to in vivo MRI. The TRE between WM and in vivo MRI was measured using anatomic landmarks. Results: Manually sliced phantoms had a 4.1 mm mean TRE, whereas mold-sliced phantoms had a 1.9 mm mean TRE. Similarly, mold-assisted slicing reduced mean angular misalignment around the left-right (LR) anatomic axis from 10.7 to 4.5 degrees. However, ex vivo MRI revealed that excised prostates were misaligned within molds, including a mean 14-degree rotation about the LR axis. The mean in-plane TRE was 3.3 mm using molds alone, and 2.2 mm after registration was corrected with ex vivo MRI. Conclusion: Patient-specific molds improved accuracy relative to manual slicing techniques in a phantom model. However, the registration accuracy of surgically resected specimens was limited by their imperfect fit within molds. This limitation can be overcome with the addition of ex vivo imaging. Significance: The accuracy of 3D printed molds was characterized, quantifying their utility for facilitating MRI-pathology registration.
- 19 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (1) , 14-22
Registration Accuracy of Patient-Specific, Three-Dimensional-Printed Prostate Molds for Correlating Pathology With Magnetic Resonance Imaging
Objective: This investigation was performed to evaluate the registration accuracy between magnetic resonance imaging (MRI) and pathology using three-dimensional (3D) printed molds. Methods: Tissue-mimicking prostate phantoms were manufactured with embedded fiducials. The fiducials were used to measure and compare target registration error (TRE) between phantoms that were sliced by hand versus phantoms sliced within 3D-printed molds. Subsequently, 10 radical prostatectomy specimens were placed inside molds, scanned with MRI, and then sliced. The ex vivo scan was used to assess the true location of whole mount (WM) slides relative to in vivo MRI. The TRE between WM and in vivo MRI was measured using anatomic landmarks. Results: Manually sliced phantoms had a 4.1 mm mean TRE, whereas mold-sliced phantoms had a 1.9 mm mean TRE. Similarly, mold-assisted slicing reduced mean angular misalignment around the left-right (LR) anatomic axis from 10.7 to 4.5 degrees. However, ex vivo MRI revealed that excised prostates were misaligned within molds, including a mean 14-degree rotation about the LR axis. The mean in-plane TRE was 3.3 mm using molds alone, and 2.2 mm after registration was corrected with ex vivo MRI. Conclusion: Patient-specific molds improved accuracy relative to manual slicing techniques in a phantom model. However, the registration accuracy of surgically resected specimens was limited by their imperfect fit within molds. This limitation can be overcome with the addition of ex vivo imaging. Significance: The accuracy of 3D printed molds was characterized, quantifying their utility for facilitating MRI-pathology registration.
- 22 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 1-12
Optical System Design for Noncontact, Normal Incidence, THz Imaging of in vivo Human Cornea
Reflection-mode terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and dielectric windows used to flatten the imaging field. Herein, we present an optical design for noncontact THz imaging of cornea. A beam-scanning methodology performs angular normal incidence sweeps of a focused beam over the corneal surface while keeping the source, detector, and patient stationary. A quasi-optical analysis method is developed to analyze the theoretical resolution and imaging field intensity profile. These results are compared to the electric field distribution computed with a physical optics analysis code. Imaging experiments validate the optical theories behind the design and suggest that quasi-optical methods are sufficient for designing of THz corneal imaging systems. Successful imaging operations support the feasibility of noncontact in vivo imaging. We believe that this optical system design will enable the first, clinically relevant, in vivo exploration of CTWC using THz technology.
- 22 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 1-12
Optical System Design for Noncontact, Normal Incidence, THz Imaging of in vivo Human Cornea
Reflection-mode terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and dielectric windows used to flatten the imaging field. Herein, we present an optical design for noncontact THz imaging of cornea. A beam-scanning methodology performs angular normal incidence sweeps of a focused beam over the corneal surface while keeping the source, detector, and patient stationary. A quasi-optical analysis method is developed to analyze the theoretical resolution and imaging field intensity profile. These results are compared to the electric field distribution computed with a physical optics analysis code. Imaging experiments validate the optical theories behind the design and suggest that quasi-optical methods are sufficient for designing of THz corneal imaging systems. Successful imaging operations support the feasibility of noncontact in vivo imaging. We believe that this optical system design will enable the first, clinically relevant, in vivo exploration of CTWC using THz technology.
- 31 August 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9585, 95850T
Exploration of the effects of burn parameters on THz wound imaging
The high contrast resolution afforded by terahertz (1 THz = 1012 Hz) imaging of physiologic tissue continues to drive explorations into the utility of THz technology for burn wound detection. Although we have previously reported the use of a novel, reflective THz imaging technology to sense spatiotemporal differences in reflectivity between partial and full thickness burn wounds, no evidence exists of a one-to-one correlation between structural damage observed in histological assessments of burn severity and THz signal. For example, varying burn induction methods may all result in a common burn wound severity, however, burn features observed in parallel THz imagery may not be identical. Successful clinical translation of THz technology as a comprehensive burn guidance tool, therefore, necessitates an understanding of THz signal and its relation to wound pathophysiology. In this work, longitudinal THz imagery was acquired with a quartz (n = 2.1, 500 μm) window of cutaneous wounds induced with the same brand geometry and contact pressure but varying contact times (5, 7, and 10 seconds) in in vivo, pre-clinical rat models (n=3) over a period of 3 days. Though all burn wounds were evaluated to be deep partial thickness with histology, THz contrasts observed for each burn contact time were intrinsically unique. This is the first preliminary in vivo evidence of a many-to-one relationship between changes in THz contrast and burn severity as ascertained by histology. Future large-scale studies are required to assess whether these observed changes in THz contrast may be interpreted as physiological changes occurring over time, morphometric changes related to anatomical change, or electromagnetic changes between dielectric substrate windows and the underlying tissue.
- 31 August 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9585, 95850T
Exploration of the effects of burn parameters on THz wound imaging
The high contrast resolution afforded by terahertz (1 THz = 1012 Hz) imaging of physiologic tissue continues to drive explorations into the utility of THz technology for burn wound detection. Although we have previously reported the use of a novel, reflective THz imaging technology to sense spatiotemporal differences in reflectivity between partial and full thickness burn wounds, no evidence exists of a one-to-one correlation between structural damage observed in histological assessments of burn severity and THz signal. For example, varying burn induction methods may all result in a common burn wound severity, however, burn features observed in parallel THz imagery may not be identical. Successful clinical translation of THz technology as a comprehensive burn guidance tool, therefore, necessitates an understanding of THz signal and its relation to wound pathophysiology. In this work, longitudinal THz imagery was acquired with a quartz (n = 2.1, 500 μm) window of cutaneous wounds induced with the same brand geometry and contact pressure but varying contact times (5, 7, and 10 seconds) in in vivo, pre-clinical rat models (n=3) over a period of 3 days. Though all burn wounds were evaluated to be deep partial thickness with histology, THz contrasts observed for each burn contact time were intrinsically unique. This is the first preliminary in vivo evidence of a many-to-one relationship between changes in THz contrast and burn severity as ascertained by histology. Future large-scale studies are required to assess whether these observed changes in THz contrast may be interpreted as physiological changes occurring over time, morphometric changes related to anatomical change, or electromagnetic changes between dielectric substrate windows and the underlying tissue.
- 22 February 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8585, 85850X
Reflectivity measurements of water and dioxane mixtures using a 100 GHz Gunn diode source
Terahertz (THz) sensing has shown potential as a novel imaging modality in medical applications due to its high water sensitivity. The design of medical THz sensing systems and their successful application to in vivo settings has attracted recent interest to the field, and highlighted the need for improved understanding of the interaction of THz waves with biological tissues. This paper explores the modeling of composite materials which combine strongly-interacting water with weakly-interacting species such as those that are common to biological tissues. The Bruggeman, Maxwell-Garnett, and power law effective media models are introduced and discussed. A reflection-mode 100 GHz Gunn diode sensing system was used to measure the reflectivity of solutions of water and dioxane as a function of relative concentration, and the results were compared with the predictions of the Maxwell-Garnett, power law, and Bruggeman mixing theories. The Maxwell-Garnett model fit poorly to experimental data on near-equal mixtures of water and dioxane and improved when the concentration of water exceeded ~55% or was below ~15%. The first-order power law model fit poorly to experimental data across the entire range except at nearpure solutions. Power law models employing 1/2 and 1/3 terms improved goodness of fit, but did not match the accuracy of the Bruggeman model. The Bruggeman provided the best fit to experimental data model as compared to Maxwell-Garnett and the power models and accurately predicted the solution reflectivity through the whole range of concentrations. This analysis suggests that the Bruggeman model may offer improved accuracy over more conventional dielectric mixing models when developing simulation tools for THz reflectometry of hydrated biological tissues.
- 22 February 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8585, 85850X
Reflectivity measurements of water and dioxane mixtures using a 100 GHz Gunn diode source
Terahertz (THz) sensing has shown potential as a novel imaging modality in medical applications due to its high water sensitivity. The design of medical THz sensing systems and their successful application to in vivo settings has attracted recent interest to the field, and highlighted the need for improved understanding of the interaction of THz waves with biological tissues. This paper explores the modeling of composite materials which combine strongly-interacting water with weakly-interacting species such as those that are common to biological tissues. The Bruggeman, Maxwell-Garnett, and power law effective media models are introduced and discussed. A reflection-mode 100 GHz Gunn diode sensing system was used to measure the reflectivity of solutions of water and dioxane as a function of relative concentration, and the results were compared with the predictions of the Maxwell-Garnett, power law, and Bruggeman mixing theories. The Maxwell-Garnett model fit poorly to experimental data on near-equal mixtures of water and dioxane and improved when the concentration of water exceeded ~55% or was below ~15%. The first-order power law model fit poorly to experimental data across the entire range except at nearpure solutions. Power law models employing 1/2 and 1/3 terms improved goodness of fit, but did not match the accuracy of the Bruggeman model. The Bruggeman provided the best fit to experimental data model as compared to Maxwell-Garnett and the power models and accurately predicted the solution reflectivity through the whole range of concentrations. This analysis suggests that the Bruggeman model may offer improved accuracy over more conventional dielectric mixing models when developing simulation tools for THz reflectometry of hydrated biological tissues.
- 1 January 2013
- Vol. 184, 230-4
Development of a novel portable multi-channel near infrared spectroscopy system.
A novel light-weight multi-channel multi-wavelength ultra-low power near infrared spectroscopy (NIRS) system was designed and tested. The NIRS system was designed for clinical use to emit low power (maximum 5 mW) red and near infrared (NIR) light into human tissue and acquire, record, and display reflected light from various tissue depths. In this paper, results of initial functional tests of the system are presented. Potential clinical applications of the NIRS system include long-term non-invasive monitoring of functional activity in tissues, oxygen consumption in skeletal muscles, and tissue blood perfusion.
- 1 January 2013
- Vol. 184, 230-4
Development of a novel portable multi-channel near infrared spectroscopy system.
A novel light-weight multi-channel multi-wavelength ultra-low power near infrared spectroscopy (NIRS) system was designed and tested. The NIRS system was designed for clinical use to emit low power (maximum 5 mW) red and near infrared (NIR) light into human tissue and acquire, record, and display reflected light from various tissue depths. In this paper, results of initial functional tests of the system are presented. Potential clinical applications of the NIRS system include long-term non-invasive monitoring of functional activity in tissues, oxygen consumption in skeletal muscles, and tissue blood perfusion.
- 12 December 2012
- Published by Springer Nature in Surgical Endoscopy
- Vol. 27 (4) , 1111-1118
The role of tactile feedback in grip force during laparoscopic training tasks
Laparoscopic minimally invasive surgery has revolutionized surgical care by reducing trauma to the patient, thereby decreasing the need for medication and shortening recovery times. During open procedures, surgeons can directly feel tissue characteristics. However, in laparoscopic surgery, tactile feedback during grip is attenuated and limited to the resistance felt in the tool handle. Excessive grip force during laparoscopic surgery can lead to tissue damage. Providing additional supplementary tactile feedback may allow subjects to have better control of grip force and identification of tissue characteristics, potentially decreasing the learning curve associated with complex minimally invasive techniques. A tactile feedback system has been developed and integrated into a modified laparoscopic grasper that allows forces applied at the grasper tips to be felt by the surgeon’s hands. In this study, 15 subjects (11 novices, 4 experts) were asked to perform single-handed peg transfers using these laparoscopic graspers in three trials (feedback OFF, ON, OFF). Peak and average grip forces (newtons) during each grip event were measured and compared using a Wilcoxon ranked test in which each subject served as his or her own control. After activating the tactile feedback system, the novice subject population showed significant decreases in grip force (p < 0.003). When the system was deactivated for the third trial, there were significant increases in grip force (p < 0.003). Expert subjects showed no significant improvements with the addition of tactile feedback (p > 0.05 in all cases). Supplementary tactile feedback helped novice subjects reduce grip force during the laparoscopic training task but did not offer improvements for the four expert subjects. This indicates that tactile feedback may be beneficial for laparoscopic training but has limited long-term use in the nonrobotic setting.
- 12 December 2012
- Published by Springer Nature in Surgical Endoscopy
- Vol. 27 (4) , 1111-1118
The role of tactile feedback in grip force during laparoscopic training tasks
Laparoscopic minimally invasive surgery has revolutionized surgical care by reducing trauma to the patient, thereby decreasing the need for medication and shortening recovery times. During open procedures, surgeons can directly feel tissue characteristics. However, in laparoscopic surgery, tactile feedback during grip is attenuated and limited to the resistance felt in the tool handle. Excessive grip force during laparoscopic surgery can lead to tissue damage. Providing additional supplementary tactile feedback may allow subjects to have better control of grip force and identification of tissue characteristics, potentially decreasing the learning curve associated with complex minimally invasive techniques. A tactile feedback system has been developed and integrated into a modified laparoscopic grasper that allows forces applied at the grasper tips to be felt by the surgeon’s hands. In this study, 15 subjects (11 novices, 4 experts) were asked to perform single-handed peg transfers using these laparoscopic graspers in three trials (feedback OFF, ON, OFF). Peak and average grip forces (newtons) during each grip event were measured and compared using a Wilcoxon ranked test in which each subject served as his or her own control. After activating the tactile feedback system, the novice subject population showed significant decreases in grip force (p < 0.003). When the system was deactivated for the third trial, there were significant increases in grip force (p < 0.003). Expert subjects showed no significant improvements with the addition of tactile feedback (p > 0.05 in all cases). Supplementary tactile feedback helped novice subjects reduce grip force during the laparoscopic training task but did not offer improvements for the four expert subjects. This indicates that tactile feedback may be beneficial for laparoscopic training but has limited long-term use in the nonrobotic setting.
- 1 January 2012
- Vol. 173, 297-303
A prototype stimulator system for noninvasive Low Intensity Focused Ultrasound delivery.
A prototype Low Intensity Focused Ultrasound (LIFU) stimulator system was developed to evaluate non-invasive neuromodulation in a large animal model. We conducted a feasibility study on a Göttingen minipig, demonstrating reversible, targeted transcranial neuromodulation. The hypothalamus of the minipig was repeatedly stimulated with LIFU which evoked temporally correlated increases in both heart rate and blood pressure.
- 1 January 2012
- Vol. 173, 297-303
A prototype stimulator system for noninvasive Low Intensity Focused Ultrasound delivery.
A prototype Low Intensity Focused Ultrasound (LIFU) stimulator system was developed to evaluate non-invasive neuromodulation in a large animal model. We conducted a feasibility study on a Göttingen minipig, demonstrating reversible, targeted transcranial neuromodulation. The hypothalamus of the minipig was repeatedly stimulated with LIFU which evoked temporally correlated increases in both heart rate and blood pressure.