Elliott R. Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Elliott R. Brown has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Warren S. Grundfest
Biomedical Engineering IDP, UCLA, Los Angeles, California United States 90095-1600
7 shared publications - Martin O. Culjat
Farus, LLC
6 shared publications W-D. Zhang
Departments of Physics and Electrical Engineering Wright State University 45435 Dayton OH USA
6 shared publications- Sophie X. Deng
Cornea Division, Stein Eye Institute, University of California Los Angeles
5 shared publications - Aleksi Tamminen
Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland
4 shared publications Hua Lee
CASIT, UCLA, Los Angeles, CA 90095
4 shared publications
Latest Publications
- 24 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 29 (5: Teraher) , 1
Editorial Introduction to JSTQE Special Issue on Terahertz Photonics (2023)
Welcome to this Special Issue of the IEEE/OSA Journal of Selected Topics in Quantum Electronics on Terahertz Photonics! This special issue, comprising 18 contributed papers and seven invited papers, represents an overview of the state of the art in this field, broadly defined to cover from 100 GHz to 10 THz. Terahertz Photonics has spearheaded the access to the Terahertz range, developing innovative THz sources and detectors at the edge of the state of the art, to enable key demonstrations in important areas of application such as broadband communications, spectroscopy, and imaging.
- 24 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 29 (5: Teraher) , 1
Editorial Introduction to JSTQE Special Issue on Terahertz Photonics (2023)
Welcome to this Special Issue of the IEEE/OSA Journal of Selected Topics in Quantum Electronics on Terahertz Photonics! This special issue, comprising 18 contributed papers and seven invited papers, represents an overview of the state of the art in this field, broadly defined to cover from 100 GHz to 10 THz. Terahertz Photonics has spearheaded the access to the Terahertz range, developing innovative THz sources and detectors at the edge of the state of the art, to enable key demonstrations in important areas of application such as broadband communications, spectroscopy, and imaging.
- Open Access
- 11 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 13 (2) , 132-144
Submillimeter-Wave Cornea Phantom Sensing Over an Extended Depth of Field With an Axicon-Generated Bessel Beam
The feasibility of a 220 - 330 GHz zero order axicon generated Bessel beam for corneal water content was explored. Simulation and experimental data from the 25-degree cone angle hyperbolic-axicon lens illuminating metallic spherical targets demonstrate a monotonically decreasing, band integrated, backscatter intensity for increasing radius of curvature from 7 – 11 mm, when lens reflector and optical axis are aligned. Further, for radii > = 9.5 mm, maximum signal was obtained with a 1 mm transverse displacement between lens and reflector optical axes arising from spatial correlation between main lobe and out of phase side lobes. Thickness and permittivity parameter estimation experiments were performed on an 8 mm radius of curvature, 1 mm thick fused quartz dome over a 10 mm axial span. Extracted thickness and permittivity varied by less than ∼ 25 μm and 0.2 respectively after correction for superluminal velocity. Estimated water permittivity and thickness of water backed gelatin phantoms showed significantly more variation due to a time varying radius of curvature. To the best of our knowledge, this is the first work that describes axicon generated Bessel beam measurements of layered spheres with varying radii of curvature, in the submillimeter range.
- 11 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 13 (2) , 132-144
Open AccessSubmillimeter-Wave Cornea Phantom Sensing Over an Extended Depth of Field With an Axicon-Generated Bessel Beam
The feasibility of a 220 - 330 GHz zero order axicon generated Bessel beam for corneal water content was explored. Simulation and experimental data from the 25-degree cone angle hyperbolic-axicon lens illuminating metallic spherical targets demonstrate a monotonically decreasing, band integrated, backscatter intensity for increasing radius of curvature from 7 – 11 mm, when lens reflector and optical axis are aligned. Further, for radii > = 9.5 mm, maximum signal was obtained with a 1 mm transverse displacement between lens and reflector optical axes arising from spatial correlation between main lobe and out of phase side lobes. Thickness and permittivity parameter estimation experiments were performed on an 8 mm radius of curvature, 1 mm thick fused quartz dome over a 10 mm axial span. Extracted thickness and permittivity varied by less than ∼ 25 μm and 0.2 respectively after correction for superluminal velocity. Estimated water permittivity and thickness of water backed gelatin phantoms showed significantly more variation due to a time varying radius of curvature. To the best of our knowledge, this is the first work that describes axicon generated Bessel beam measurements of layered spheres with varying radii of curvature, in the submillimeter range.
- 4 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 12 (2) , 151-164
650 GHz Imaging as Alignment Verification for Millimeter Wave Corneal Reflectometry
A system concept for online alignment verification of millimeter-wave, corneal reflectometry is presented. The system utilizes beam scanning to generate magnitude-only reflectivity maps of the cornea at 650 GHz and compares these images to a precomputed/measured template map to confirm/reject sufficient alignment. A system utilizing five off-axis parabolic mirrors, a thin film beam splitter, and two-axis galvanometric mirror was designed, simulated, and evaluated with geometric and physical optics. Simulation results informed the construction of a demonstrator system which was tested with a reference reflector. Similarity metrics computed with the aligned template and 26 misaligned positions, distributed on a 0.5 mm x 0.5 mm x 0.5 mm mesh, demonstrated sufficient misalignment detection sensitivity in 23 out of 26 positions. The results show that positional accuracy on the order of 0.5 mm is possible using 0.462 mm wavelength radiation due to the perturbation of coupling efficiency via beam distortion and beam walk-off.
- 4 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 12 (2) , 151-164
650 GHz Imaging as Alignment Verification for Millimeter Wave Corneal Reflectometry
A system concept for online alignment verification of millimeter-wave, corneal reflectometry is presented. The system utilizes beam scanning to generate magnitude-only reflectivity maps of the cornea at 650 GHz and compares these images to a precomputed/measured template map to confirm/reject sufficient alignment. A system utilizing five off-axis parabolic mirrors, a thin film beam splitter, and two-axis galvanometric mirror was designed, simulated, and evaluated with geometric and physical optics. Simulation results informed the construction of a demonstrator system which was tested with a reference reflector. Similarity metrics computed with the aligned template and 26 misaligned positions, distributed on a 0.5 mm x 0.5 mm x 0.5 mm mesh, demonstrated sufficient misalignment detection sensitivity in 23 out of 26 positions. The results show that positional accuracy on the order of 0.5 mm is possible using 0.462 mm wavelength radiation due to the perturbation of coupling efficiency via beam distortion and beam walk-off.
- Open Access
- 22 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 61
Investigation of THz Absorptive Signatures in Opioids
We investigate the possibility of sensing opioid drugs, such as fentanyl, by their THz electromagnetic signatures. The methods include both computer modeling and experiments. Molecular dynamics simulations predict that fentanyl should display THz resonances, with several of them occurring below 1.0 THz; the lowest one is at around 0.337 THz (337 GHz). Spectroscopy measurements were conducted on oxycodone, which was used as a surrogate for fentanyl. They display vibrational absorption resonances between ∼1.4 and 1.6 THz.
- 22 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 61
Open AccessInvestigation of THz Absorptive Signatures in Opioids
We investigate the possibility of sensing opioid drugs, such as fentanyl, by their THz electromagnetic signatures. The methods include both computer modeling and experiments. Molecular dynamics simulations predict that fentanyl should display THz resonances, with several of them occurring below 1.0 THz; the lowest one is at around 0.337 THz (337 GHz). Spectroscopy measurements were conducted on oxycodone, which was used as a surrogate for fentanyl. They display vibrational absorption resonances between ∼1.4 and 1.6 THz.
- 3 November 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 16 (5) , 054008
Electroluminescence in Unipolar-Doped Resonant-Tunneling Diodes: A Competition between Interband Tunneling and Impact IonizationWe measure and analyze the light emission from a room-temperature n-type unipolar-doped double-barrier resonant-tunneling diode (RTD) that occurs just above the band edge and peaks around 1631 nm. The emission is attributed to electron-hole recombination emission made possible by holes generated in the high-field region on the collector side of the device by interband tunneling and impact ionization, which contribute comparable hole densities, according to our analysis. Although the external quantum efficiency (EQE) in our experimental configuration is rather low (≈2 × at 3.0-V bias), limited by suboptimal output coupling, the internal quantum efficiency (IQE) is much higher (≈6% at 3.0-V bias), as derived from the experimental EQE and a radiometric analysis. To check this value and better understand the transport physics, we also carry out an independent estimate of the IQE using a combined interband-tunneling impact-ionization transport model, which yields an IQE of 10% at 3.0-V bias. The satisfactory agreement of theory with experimental data suggests that a RTD designed for better hole transport and superior optical coupling could become a useful light-emitting device, while retaining the intrinsic functionality of high-speed negative differential resistance, and all without the need for resistive p-type doping.- 3 November 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 16 (5) , 054008
Electroluminescence in Unipolar-Doped Resonant-Tunneling Diodes: A Competition between Interband Tunneling and Impact IonizationWe measure and analyze the light emission from a room-temperature n-type unipolar-doped double-barrier resonant-tunneling diode (RTD) that occurs just above the band edge and peaks around 1631 nm. The emission is attributed to electron-hole recombination emission made possible by holes generated in the high-field region on the collector side of the device by interband tunneling and impact ionization, which contribute comparable hole densities, according to our analysis. Although the external quantum efficiency (EQE) in our experimental configuration is rather low (≈2 × at 3.0-V bias), limited by suboptimal output coupling, the internal quantum efficiency (IQE) is much higher (≈6% at 3.0-V bias), as derived from the experimental EQE and a radiometric analysis. To check this value and better understand the transport physics, we also carry out an independent estimate of the IQE using a combined interband-tunneling impact-ionization transport model, which yields an IQE of 10% at 3.0-V bias. The satisfactory agreement of theory with experimental data suggests that a RTD designed for better hole transport and superior optical coupling could become a useful light-emitting device, while retaining the intrinsic functionality of high-speed negative differential resistance, and all without the need for resistive p-type doping.- Open Access
Temperature Characterization of Unipolar-Doped Electroluminescence in Vertical GaN/AlN Heterostructures
An electroluminescence (EL) phenomenon in unipolar-doped GaN/AlN/GaN double-barrier heterostructures—without any p-type contacts—was investigated from 4.2 K to 300 K. In the range of 200–300 K, the extracted peak photon energies agree with the Monemar formula. In the range of 30 to 200 K, the photon energies are consistent with A-exciton emission. At 4.2 K, the exciton type likely transforms into B-exciton. These studies confirm that the EL emission comes from a cross-bandgap (or band-to-band) electron-hole radiative recombination and is excitonic. The excitons are formed by the holes generated through interband tunneling and the electrons injected into the GaN emitter region of the GaN/AlN heterostructure devices.
Open AccessTemperature Characterization of Unipolar-Doped Electroluminescence in Vertical GaN/AlN Heterostructures
An electroluminescence (EL) phenomenon in unipolar-doped GaN/AlN/GaN double-barrier heterostructures—without any p-type contacts—was investigated from 4.2 K to 300 K. In the range of 200–300 K, the extracted peak photon energies agree with the Monemar formula. In the range of 30 to 200 K, the photon energies are consistent with A-exciton emission. At 4.2 K, the exciton type likely transforms into B-exciton. These studies confirm that the EL emission comes from a cross-bandgap (or band-to-band) electron-hole radiative recombination and is excitonic. The excitons are formed by the holes generated through interband tunneling and the electrons injected into the GaN emitter region of the GaN/AlN heterostructure devices.
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 11 (6) , 647-659
Extraction of Thickness and Water-Content Gradients in Hydrogel-Based Water-Backed Corneal Phantoms Via Submillimeter-Wave Reflectometry
Absolute thickness and free water content gradients in gelatin-based corneal phantoms with physiologically accurate radii of curvature, and aqueous backing were extracted via coherent submillimeter wave reflectometry at 220 330 GHz. Fourier-domain based calibration methods, utilizing temporal and spatial gating, were developed and yielded peak-to-peak amplitude and phase clutter of 10-3 and 0.1, respectively for signal to noise ratios between 40 dB and 50 dB. Twelve phantoms were fabricated. Calibration methods enabled quantification of target sphericity that strongly correlated with optical coherence tomography-based sphericity metrics via image segmentation. Extracted free water volume fraction varied less than 5 % in the 5 phantoms whose fabrication yielded the most spherical geometry. Submillimeter wave-based thickness accuracy was better than 111 m (~/9) with average of 65 m (~/17) and standard deviation of 44 m (~/25) for phantoms with physiologically relevant geometry. Monte Carlo simulations of measurement noise and uncertainty limits agree with experimental data analysis and indicates a lower thickness accuracy limit of 33 m, and water content sensitivities of 0.5 % and 11.8 % for the anterior and posterior segments respectively. Numerical analysis suggests measurement fidelity was SNR limited and identified optical path length ambiguities within the cornea where a continuum of thickness/water gradient pairs produce statistically insignificant differences in complex reflection coefficient for finite SNR. This is the first known submillimeter-wave measurement technique able to extract both the thickness and water content gradients from a soft-tissue phantom, with a water backing, without the need for ancillary measurements.
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 11 (6) , 647-659
Extraction of Thickness and Water-Content Gradients in Hydrogel-Based Water-Backed Corneal Phantoms Via Submillimeter-Wave Reflectometry
Absolute thickness and free water content gradients in gelatin-based corneal phantoms with physiologically accurate radii of curvature, and aqueous backing were extracted via coherent submillimeter wave reflectometry at 220 330 GHz. Fourier-domain based calibration methods, utilizing temporal and spatial gating, were developed and yielded peak-to-peak amplitude and phase clutter of 10-3 and 0.1, respectively for signal to noise ratios between 40 dB and 50 dB. Twelve phantoms were fabricated. Calibration methods enabled quantification of target sphericity that strongly correlated with optical coherence tomography-based sphericity metrics via image segmentation. Extracted free water volume fraction varied less than 5 % in the 5 phantoms whose fabrication yielded the most spherical geometry. Submillimeter wave-based thickness accuracy was better than 111 m (~/9) with average of 65 m (~/17) and standard deviation of 44 m (~/25) for phantoms with physiologically relevant geometry. Monte Carlo simulations of measurement noise and uncertainty limits agree with experimental data analysis and indicates a lower thickness accuracy limit of 33 m, and water content sensitivities of 0.5 % and 11.8 % for the anterior and posterior segments respectively. Numerical analysis suggests measurement fidelity was SNR limited and identified optical path length ambiguities within the cornea where a continuum of thickness/water gradient pairs produce statistically insignificant differences in complex reflection coefficient for finite SNR. This is the first known submillimeter-wave measurement technique able to extract both the thickness and water content gradients from a soft-tissue phantom, with a water backing, without the need for ancillary measurements.
- 10 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 11 (5) , 538-547
Submillimeter-Wave Permittivity Measurements of Bound Water in Collagen Hydrogels via Frequency Domain Spectroscopy
This paper presents measurements of the permittivity of gelatin hydrogels between 220 and 330 GHz. Hydrated gelatin was treated as a binary mixture of free water and a compound consisting of water bound to collagen. Submillimeter-wave reflectometry was used to estimate the hydrated gelatin permittivity, hydrated gelatin density, and free-water volume fraction in phantoms composed of 62, 67, 72, and 77% water by weight. A hydrated dry/wet density ratio of 0.335 was validated with optical-coherence tomography. A constant non-freezing bound-water mass of 0.6 g/g was observed and confirmed with differential-scanning calorimetry. Good agreement between results from different modalities supports the dielectric spectroscopy methods and data analysis. Depending on the hydrodynamics at the sample/air interface, measurements indicate a bound-water compound permittivity of 3.77 - j2.52 to 3.95 - j2.49 contrasting the pure-water average permittivity of 5.16 j5.63. The loss related to bound water was much higher than anticipated and characterization will help reduce uncertainty in measurements of gelatin hydrogel-based tissue phantoms; particularly corneal phantoms where adjacent free water creates complex hydration gradients. This is the first known, submillimeter-wave, frequency domain measurement of complex permittivity of the bound-water component in solid, proteinaceous matter.
- 10 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 11 (5) , 538-547
Submillimeter-Wave Permittivity Measurements of Bound Water in Collagen Hydrogels via Frequency Domain Spectroscopy
This paper presents measurements of the permittivity of gelatin hydrogels between 220 and 330 GHz. Hydrated gelatin was treated as a binary mixture of free water and a compound consisting of water bound to collagen. Submillimeter-wave reflectometry was used to estimate the hydrated gelatin permittivity, hydrated gelatin density, and free-water volume fraction in phantoms composed of 62, 67, 72, and 77% water by weight. A hydrated dry/wet density ratio of 0.335 was validated with optical-coherence tomography. A constant non-freezing bound-water mass of 0.6 g/g was observed and confirmed with differential-scanning calorimetry. Good agreement between results from different modalities supports the dielectric spectroscopy methods and data analysis. Depending on the hydrodynamics at the sample/air interface, measurements indicate a bound-water compound permittivity of 3.77 - j2.52 to 3.95 - j2.49 contrasting the pure-water average permittivity of 5.16 j5.63. The loss related to bound water was much higher than anticipated and characterization will help reduce uncertainty in measurements of gelatin hydrogel-based tissue phantoms; particularly corneal phantoms where adjacent free water creates complex hydration gradients. This is the first known, submillimeter-wave, frequency domain measurement of complex permittivity of the bound-water component in solid, proteinaceous matter.
- 1 August 2019
- Published by Springer Nature
- p. 249-281
Fabrication and Characterization of GaN/AlN Resonant Tunneling Diodes
- 1 August 2019
- Published by Springer Nature
- p. 249-281
Fabrication and Characterization of GaN/AlN Resonant Tunneling Diodes
- Open Access
- 26 July 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (15) , 3014
THz Superradiance from a GaAs: ErAs Quantum Dot Array at Room Temperature
We report that an ErAs quantum-dot array in a GaAs matrix under 1550 nm pulsed excitation produces cooperative spontaneous emission—Dicke superradiance—in the terahertz frequency region at room temperature. Two key points pertain to the experimental evidence: (i) the pulsed THz emission power is much greater than the continuous wave (CW) photomixing power; and (ii) the ultrafast time-domain waveform displays ringing cycles. A record of ~117 μW pulsed THz power was obtained, with a 1550 nm-to-THz power conversion efficiency of ~0.2%.
- 26 July 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (15) , 3014
Open AccessTHz Superradiance from a GaAs: ErAs Quantum Dot Array at Room Temperature
We report that an ErAs quantum-dot array in a GaAs matrix under 1550 nm pulsed excitation produces cooperative spontaneous emission—Dicke superradiance—in the terahertz frequency region at room temperature. Two key points pertain to the experimental evidence: (i) the pulsed THz emission power is much greater than the continuous wave (CW) photomixing power; and (ii) the ultrafast time-domain waveform displays ringing cycles. A record of ~117 μW pulsed THz power was obtained, with a 1550 nm-to-THz power conversion efficiency of ~0.2%.