DNDieter De Naeyer

Dieter De Naeyer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dieter De Naeyer has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Flip angle optimization for dynamic contrast-enhanced MRI-studies with spoiled gradient echo pulse sequences

    by D De Naeyer, J Verhulst, W Ceelen, P Segers, Y De Deene, P Verdonck

    Spoiled gradient echo pulse (SPGRE) sequences are commonly used in dynamic contrast-enhanced MRI (DCE-MRI) studies to measure the contrast agent concentration in a tissue of interest over time. However, due to improper tuning of the SPGRE parameters, concentration uncertainty can be very high, even at high signal-to-noise ratio in the MR measurement. In this work, an optimization procedure is proposed for selecting the optimal value of the SPGRE-flip angle FA(opt), given the expected concentration range. The optimization condition ensures that every concentration in the assumed range has the lowest possible uncertainty. By decoupling the R(1)- and R*(2)-effects caused by the presence of the contrast agent, a contour plot has been generated from which FA(opt) can be read off for any study design. Investigation of ten recent DCE-MRI studies showed that improper flip angle selection unnecessarily increases the concentration uncertainty, up to 742% and 72% on average for the typical physiological concentration ranges of 0-2 mM in tumour tissue and 0-10 mM in blood, respectively. Simulations show that the reduced noise levels on the concentration curves, observed at the optimal flip angle, effectively increase the precision of the kinetic parameters estimates (up to 82% for K(trans), 82% for ν(e) and 92% for ν(p) in the case of an individually measured arterial input function (AIF), up to 53% for K(trans), 59% for ν(e) and 67% for ν(p) in the case of a standard AIF). In vivo experiments confirm the potential of flip angle optimization to increase the reproducibility of the kinetic parameter estimates.


  • Open Access

    First order correction for T2*‐relaxation in determining contrast agent concentration from spoiled gradient echo pulse sequence signal intensity

    by Dieter De Naeyer, Isabelle Debergh, Yves De Deene, Wim P. Ceelen, Patrick Segers, Pascal Verdonck

    Purpose: To investigate the accuracy of a method neglecting T2*‐relaxation, for the conversion of spoiled gradient echo pulse sequence signal intensity to contrast agent (CA) concentration, in dynamic contrast enhanced MRI studies. In addition a new closed form conversion expression is proposed that accounts for a first order approximation of T2*‐relaxation.Materials and Methods: The accuracy of both conversion methods is compared theoretically by means of simulations for four pulse sequences from literature. Both methods are tested in vivo against the numerical conversion method for measuring the arterial input function in mice.Results: Simulations show that the T2*‐neglecting method underestimates typical tissue CA concentrations (0 mM to 2 mM) up to 6%, while the errors for arterial concentrations (0 mM to 10 mM) range up to 43%. The results from our first order method are numerically indistinguishable from the simulation input values in tumor tissue, while for arterial concentrations the error is reduced up to a factor 10. In vivo, peak Gd‐DOTA concentration is underestimated up to 14% with the T2*‐neglecting method and up to 0.9% with our first order method.Conclusion: Our conversion method reduces the underestimation of CA concentration severely in a broad physiological concentration range and is easy to perform in any clinical setting. J. Magn. Reson. Imaging 2011;.


  • Open Access

    P-glycoprotein at the blood-brain barrier: kinetic modeling of 11C-desmethylloperamide in mice using a 18F-FDG μPET scan to determine the input function

    by Lieselotte Moerman, Dieter De Naeyer, Paul Boon, Filip De Vos

    The objective of this study is the implementation of a kinetic model for 11C-desmethylloperamide (11C-dLop) and the determination of a typical parameter for P-glycoprotein (P-gp) functionality in mice. Since arterial blood sampling in mice is difficult, an alternative method to obtain the arterial plasma input curve used in the kinetic model is proposed. Wild-type (WT) mice (pre-injected with saline or cyclosporine) and P-gp knock-out (KO) mice were injected with 20 MBq of 11C-dLop, and a dynamic μPET scan was initiated. Afterwards, 18.5 MBq of 18F-FDG was injected, and a static μPET scan was started. An arterial input and brain tissue curve was obtained by delineation of an ROI on the left heart ventricle and the brain, respectively based on the 18F-FDG scan. A comparison between the arterial input curves obtained by the alternative and the blood sampling method showed an acceptable agreement. The one-tissue compartment model gives the best results for the brain. In WT mice, the K1/k2 ratio was 0.4 ± 0.1, while in KO mice and cyclosporine-pretreated mice the ratio was much higher (2.0 ± 0.4 and 1.9 ± 0.2, respectively). K1 can be considered as a pseudo value K1, representing a combination of passive influx of 11C-desmethylloperamide and a rapid washout by P-glycoprotein, while k2 corresponds to slow passive efflux out of the brain. An easy to implement kinetic modeling for imaging P-glycoprotein function is presented in mice without arterial blood sampling. The ratio of K1/k2 obtained from a one-tissue compartment model can be considered as a good value for P-glycoprotein functionality.