Toru Masuzawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Toru Masuzawa has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Yohji Okada
Ibaraki Univ
6 shared publications Hiroyuki Onuma
3 shared publications- Takashi Yamane
Kobe University
3 shared publications - Tomonori Tsukiya
National Cardiovascular Center
3 shared publications Yoshiyuki Taenaka
3 shared publicationsKazuhide Ozeki
Department of Mechanical Engineering, College of Engineering, Ibaraki University, 1-12-1 Nakanarusawa, Hitachi, Ibaraki, Japan
2 shared publications
Latest Publications
- 3 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (2) , 1516-1523
A Double-Sided Stator Type Axial Bearingless Motor Development for Total Artificial Heart
This paper proposed a self-bearing motor that has tilt control function and clarified its fundamental characteristics as a maglev motor and maglev pump. The rotor has eight permanent magnets on each side (sixteen permanent magnets in total). The two stators have twelve poles each with two types of concentrated windings. One is for motoring and axial control; the other is for tilt control. The theoretical analysis clarified operating principle and showed that the proposed motor could control translational motion, inclinational and rotational movement independently. An experimental setup was fabricated, and the control performance of the self-bearing motor was also investigated. The fabricated prototype achieved a stable magnetically levitated rotation. In addition, the proposed axial self-bearing motor fabricated into a prototype of the maglev pump to investigate pump characteristics for a total artificial heart applications.
- 3 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (2) , 1516-1523
A Double-Sided Stator Type Axial Bearingless Motor Development for Total Artificial Heart
This paper proposed a self-bearing motor that has tilt control function and clarified its fundamental characteristics as a maglev motor and maglev pump. The rotor has eight permanent magnets on each side (sixteen permanent magnets in total). The two stators have twelve poles each with two types of concentrated windings. One is for motoring and axial control; the other is for tilt control. The theoretical analysis clarified operating principle and showed that the proposed motor could control translational motion, inclinational and rotational movement independently. An experimental setup was fabricated, and the control performance of the self-bearing motor was also investigated. The fabricated prototype achieved a stable magnetically levitated rotation. In addition, the proposed axial self-bearing motor fabricated into a prototype of the maglev pump to investigate pump characteristics for a total artificial heart applications.
- Open Access
- 1 January 2017
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 25 (2) , 198-204
Miniaturization of Pediatric VAD with 5-DOF Controlled Maglev Motor
A 5-degrees of freedom (5-DOF) controlled maglev motor and a centrifugal blood pump have been developed for pediatric ventricular assist devices (VADs). The magnetically suspended pediatric VAD consists of a top stator, a bottom stator and a levitated impeller. A double stator mechanism enhances a torque production. The maglev pediatric VAD has an outer diameter of 22 mm, a total length of 34 mm and a total volume of 18 cc. In this study the pump performance of the developed centrifugal pump was investigated, as well as the magnetic suspension ability of the developed 5-DOF controlled self-bearing motor was evaluated. The developed maglev pediatric VAD produced a flow rate up to 2.5 L/min against a pump head pressure of 100 mmHg at an impeller rotating speed of 5000 rpm. The maximum oscillation amplitudes that were 0.08 mm in axial direction and 0.19 mm in radial direction were less than the clearance of the centrifugal blood pump.
- 1 January 2017
- Published by Japan Society of Applied Electromagnetics and Mechanics in Journal of the Japan Society of Applied Electromagnetics and Mechanics
- Vol. 25 (2) , 198-204
Open AccessMiniaturization of Pediatric VAD with 5-DOF Controlled Maglev Motor
A 5-degrees of freedom (5-DOF) controlled maglev motor and a centrifugal blood pump have been developed for pediatric ventricular assist devices (VADs). The magnetically suspended pediatric VAD consists of a top stator, a bottom stator and a levitated impeller. A double stator mechanism enhances a torque production. The maglev pediatric VAD has an outer diameter of 22 mm, a total length of 34 mm and a total volume of 18 cc. In this study the pump performance of the developed centrifugal pump was investigated, as well as the magnetic suspension ability of the developed 5-DOF controlled self-bearing motor was evaluated. The developed maglev pediatric VAD produced a flow rate up to 2.5 L/min against a pump head pressure of 100 mmHg at an impeller rotating speed of 5000 rpm. The maximum oscillation amplitudes that were 0.08 mm in axial direction and 0.19 mm in radial direction were less than the clearance of the centrifugal blood pump.
- 7 May 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 104 (3) , 538-545
Thermal denaturation behavior of collagen fibrils in wet and dry environment
We have developed a new minimally invasive technique––integrated low‐level energy adhesion technique (ILEAT)––which uses heat, pressure, and low‐frequency vibrations for binding living tissues. Because the adhesion mechanism of the living tissues is not fully understood, we investigated the effect of thermal energy on the collagen structure in living tissues using ILEAT. To study the effect of thermal energy and heating time on the structure of the collagen fibril, samples were divided in two categories–wet and dry. Further, atomic force microscopy was used to analyze the collagen fibril structure before and after heating. Results showed that collagen fibrils in water denatured after 1 minute at temperatures higher than 80°C, while partial denaturation was observed at temperatures of 80°C and a heating time of 1 min. Furthermore, complete denaturation was achieved after 90 min, suggesting that the denaturation rate is temperature and time dependent. Moreover, the collagen fibrils in dry condition maintained their native structure even after being heated to 120°C for 90 min in the absence of water, which specifically suppressed denaturation. However, partial denaturation of collagen fibrils could not be prevented, because this determines the adhesion between the collagen molecules, and stabilizes tissue bonding. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 538–545, 2016.
- 7 May 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 104 (3) , 538-545
Thermal denaturation behavior of collagen fibrils in wet and dry environment
We have developed a new minimally invasive technique––integrated low‐level energy adhesion technique (ILEAT)––which uses heat, pressure, and low‐frequency vibrations for binding living tissues. Because the adhesion mechanism of the living tissues is not fully understood, we investigated the effect of thermal energy on the collagen structure in living tissues using ILEAT. To study the effect of thermal energy and heating time on the structure of the collagen fibril, samples were divided in two categories–wet and dry. Further, atomic force microscopy was used to analyze the collagen fibril structure before and after heating. Results showed that collagen fibrils in water denatured after 1 minute at temperatures higher than 80°C, while partial denaturation was observed at temperatures of 80°C and a heating time of 1 min. Furthermore, complete denaturation was achieved after 90 min, suggesting that the denaturation rate is temperature and time dependent. Moreover, the collagen fibrils in dry condition maintained their native structure even after being heated to 120°C for 90 min in the absence of water, which specifically suppressed denaturation. However, partial denaturation of collagen fibrils could not be prevented, because this determines the adhesion between the collagen molecules, and stabilizes tissue bonding. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 538–545, 2016.
- 30 August 2012
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 15 (4) , 386-394
Effect of metal surface characteristics on the adhesion performance of the integrated low-level energies method of adhesion
We have previously proposed a new method of adhesion using the integrated low-level energy sources heat, vibration, and pressure. This adhesion method can be used to attach biological tissue to a metal object. Effects of surface roughness and energy of the metal subject on adhesion performance were studied by using commercially pure titanium (cpTi) and stainless steel (SUS304). Surface roughness and energy were changed by sandblast treatment and heat treatment, respectively. A porcine aorta was adhered to sandblast-treated SUS304 by use of an adhesion temperature of 80 °C, a vibration amplitude of 15 μm, a pressure of 2.5 MPa, an adhesion time of 120 s, and a surface roughness of an Ra 0.25 μm. The shear tensile strength of the adhesion was 0.45 MPa. The adhesion performance was improved by roughening the surface of the metal specimen. Surface energy has an insignificant effect on adhesive strength. The adhesion performance varied depending on metal material for the same surface roughness, Ra, and energy. Results from analysis of the surface roughness profile suggested that the size of surface asperity has an effect on adhesion performance.
- 30 August 2012
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 15 (4) , 386-394
Effect of metal surface characteristics on the adhesion performance of the integrated low-level energies method of adhesion
We have previously proposed a new method of adhesion using the integrated low-level energy sources heat, vibration, and pressure. This adhesion method can be used to attach biological tissue to a metal object. Effects of surface roughness and energy of the metal subject on adhesion performance were studied by using commercially pure titanium (cpTi) and stainless steel (SUS304). Surface roughness and energy were changed by sandblast treatment and heat treatment, respectively. A porcine aorta was adhered to sandblast-treated SUS304 by use of an adhesion temperature of 80 °C, a vibration amplitude of 15 μm, a pressure of 2.5 MPa, an adhesion time of 120 s, and a surface roughness of an Ra 0.25 μm. The shear tensile strength of the adhesion was 0.45 MPa. The adhesion performance was improved by roughening the surface of the metal specimen. Surface energy has an insignificant effect on adhesive strength. The adhesion performance varied depending on metal material for the same surface roughness, Ra, and energy. Results from analysis of the surface roughness profile suggested that the size of surface asperity has an effect on adhesion performance.
- 1 January 2010
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 43 (18) , 461-466
Development of Flux Concentrated type Self-Bearing Motor
- 1 January 2010
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 43 (18) , 461-466
Development of Flux Concentrated type Self-Bearing Motor
- 19 September 2009
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 12 (3) , 150-159
Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis
The effect of the hydraulic force on magnetically levitated (maglev) pumps should be studied carefully to improve the suspension performance and the reliability of the pumps. A maglev centrifugal pump, developed at Ibaraki University, was modeled with 926 376 hexahedral elements for computational fluid dynamics (CFD) analyses. The pump has a fully open six-vane impeller with a diameter of 72.5 mm. A self-bearing motor suspends the impeller in the radial direction. The maximum pressure head and flow rate were 250 mmHg and 14 l/min, respectively. First, a steady-state analysis was performed using commercial code STAR-CD to confirm the model’s suitability by comparing the results with the real pump performance. Second, transient analysis was performed to estimate the hydraulic force on the levitated impeller. The impeller was rotated in steps of 1° using a sliding mesh. The force around the impeller was integrated at every step. The transient analysis revealed that the direction of the radial force changed dynamically as the vane’s position changed relative to the outlet port during one circulation, and the magnitude of this force was about 1 N. The current maglev pump has sufficient performance to counteract this hydraulic force. Transient CFD analysis is not only useful for observing dynamic flow conditions in a centrifugal pump but is also effective for obtaining information about the levitation dynamics of a maglev pump.
- 19 September 2009
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 12 (3) , 150-159
Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis
The effect of the hydraulic force on magnetically levitated (maglev) pumps should be studied carefully to improve the suspension performance and the reliability of the pumps. A maglev centrifugal pump, developed at Ibaraki University, was modeled with 926 376 hexahedral elements for computational fluid dynamics (CFD) analyses. The pump has a fully open six-vane impeller with a diameter of 72.5 mm. A self-bearing motor suspends the impeller in the radial direction. The maximum pressure head and flow rate were 250 mmHg and 14 l/min, respectively. First, a steady-state analysis was performed using commercial code STAR-CD to confirm the model’s suitability by comparing the results with the real pump performance. Second, transient analysis was performed to estimate the hydraulic force on the levitated impeller. The impeller was rotated in steps of 1° using a sliding mesh. The force around the impeller was integrated at every step. The transient analysis revealed that the direction of the radial force changed dynamically as the vane’s position changed relative to the outlet port during one circulation, and the magnitude of this force was about 1 N. The current maglev pump has sufficient performance to counteract this hydraulic force. Transient CFD analysis is not only useful for observing dynamic flow conditions in a centrifugal pump but is also effective for obtaining information about the levitation dynamics of a maglev pump.
- 1 January 2008
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 20 (Supplement) , 113
Drug adsorbability of sputtered hydroxyapatite films and its antithrombogenicity
- 1 January 2008
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 20 (Supplement) , 113
Drug adsorbability of sputtered hydroxyapatite films and its antithrombogenicity
- 1 January 2007
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 19 (Supplement) , 76
The CDF Analysis of Maglev Artificial Heart Pump
- 1 January 2007
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 19 (Supplement) , 76
The CDF Analysis of Maglev Artificial Heart Pump
- Open Access
- 1 January 2004
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 16 (Supplement) , 167-168
Improvement of centrifugal blood pump for artificial heart with radially Maglev motor
- 1 January 2004
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 16 (Supplement) , 167-168
Open AccessImprovement of centrifugal blood pump for artificial heart with radially Maglev motor
- 1 January 2002
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2002.14, 191-192
Magnetically suspended centrifugal blood pump as next generation of artificial heart : miniaturization and improvement of the efficiency of the magnetic suspension system
- 1 January 2002
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2002.14, 191-192
Magnetically suspended centrifugal blood pump as next generation of artificial heart : miniaturization and improvement of the efficiency of the magnetic suspension system