Roger L. Barker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Roger L. Barker has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Huipu Gao
Textile Protection and Comfort Center, North Carolina State University, USA
3 shared publications A Shawn Deaton
Textile Protection and Comfort Center, North Carolina State University, Raleigh, NC, United States of America
2 shared publications- Alexander Hummel
Textile Protection and Comfort Center, College of Textiles, North Carolina State University, Raleigh, USA
2 shared publications - Anthoney S. Deaton
Special Projects Director, Center for Research on Textile Protection and Comfort, College of Textiles, North Carolina State Univ., Raleigh, NC, United States 27695–8301
2 shared publications - Anthoney Shawn Deaton
Textile Protection and Comfort Center, North Carolina State University, USA
2 shared publications Huipu Gao
Textile Development and Marketing Department, Fashion Institute of Technology, New York, USA
2 shared publications
Latest Publications
- 1 January 2023
- Published by Springer Nature in Fibers and Polymers
- Vol. 24 (1) , 187-194
A Novel Method for Measuring the Wet Cling Properties of Textiles
- 1 January 2023
- Published by Springer Nature in Fibers and Polymers
- Vol. 24 (1) , 187-194
A Novel Method for Measuring the Wet Cling Properties of Textiles
- 7 October 2022
- Published by Springer Nature in Fibers and Polymers
- Vol. 23 (11) , 3214-3224
Effects of Air Gaps on Heat Loss through Firefighter Turnout Composites with Different Moisture Barrier Components
- 7 October 2022
- Published by Springer Nature in Fibers and Polymers
- Vol. 23 (11) , 3214-3224
Effects of Air Gaps on Heat Loss through Firefighter Turnout Composites with Different Moisture Barrier Components
- 6 September 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (12) , 125601
A new test method for evaluating the evaporative cooling efficiency of fabrics using a dynamic sweating hot plate
The lack of direct measures of the ability of a fabric to cool the skin by liquid sweat evaporation is a critical gap in available laboratory tests for evaluating the comfort of active wear clothing materials. This paper describes a novel method designed to evaluate the evaporative cooling performance of fabrics in a protocol that simulates active wear, including sweating and drying periods, in a continuous one-step procedure. It uses a dynamic sweating hot plate to measure the latent heat absorbed by fabrics in sweat evaporation, and in drying after sweat absorption. The efficacy of the method is demonstrated using a selected set of high-wicking polyester and a cotton knit t-shirt material that have different moisture absorption, wicking and drying properties. The cooling efficiency test shows that high-wicking polyester fabrics provide larger evaporative cooling in the sweating phase, where it is more likely to convey cooling benefits to the skin. Cotton fabrics absorb more latent heat in the drying phase, where the cooling effect may contribute to chilling effects. It provides an ideal platform to observe the dynamic relationship between patterns of wicking and liquid moisture spreading in fabrics and the evaporative cooling provided by the test materials. It shows that the location of wicked moisture in the fabric is a critical determinant of potential cooling effects. It also shows that a fabric’s wicking ability is not always an accurate predictor of its cooling efficiency. This new test method has provided a unique tool for directly characterizing the cooling efficiency of clothing materials using a protocol that accurately simulates sweating generation and drying in actual active wear scenarios.
- 6 September 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (12) , 125601
A new test method for evaluating the evaporative cooling efficiency of fabrics using a dynamic sweating hot plate
The lack of direct measures of the ability of a fabric to cool the skin by liquid sweat evaporation is a critical gap in available laboratory tests for evaluating the comfort of active wear clothing materials. This paper describes a novel method designed to evaluate the evaporative cooling performance of fabrics in a protocol that simulates active wear, including sweating and drying periods, in a continuous one-step procedure. It uses a dynamic sweating hot plate to measure the latent heat absorbed by fabrics in sweat evaporation, and in drying after sweat absorption. The efficacy of the method is demonstrated using a selected set of high-wicking polyester and a cotton knit t-shirt material that have different moisture absorption, wicking and drying properties. The cooling efficiency test shows that high-wicking polyester fabrics provide larger evaporative cooling in the sweating phase, where it is more likely to convey cooling benefits to the skin. Cotton fabrics absorb more latent heat in the drying phase, where the cooling effect may contribute to chilling effects. It provides an ideal platform to observe the dynamic relationship between patterns of wicking and liquid moisture spreading in fabrics and the evaporative cooling provided by the test materials. It shows that the location of wicked moisture in the fabric is a critical determinant of potential cooling effects. It also shows that a fabric’s wicking ability is not always an accurate predictor of its cooling efficiency. This new test method has provided a unique tool for directly characterizing the cooling efficiency of clothing materials using a protocol that accurately simulates sweating generation and drying in actual active wear scenarios.
- Open Access
- 2 May 2022
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 29 (2) , 562-572
Relationship between heat loss indexes and physiological indicators of turnout-related heat strain in mild and hot environments
A validated physiological manikin method was used to qualify environmentally dependent correlations between firefighter turnout total heat loss (THL) and intrinsic evaporative resistance (Ref) heat strain indexes and core temperature rise in stressful work conducted in mild (25 °C, 65% relative humidity [RH]) and hot (35 °C, 40% RH; 40 °C, 28% RH) conditions. Five turnout suit constructions representing a wide range of breathability were selected. The observed correlations between measured material heat loss and core temperature showed that the THL heat strain index accurately forecast thermal burden in mild environments (35 °C). They showed that the THL index did not predict heat strain in hot work environments. The findings of this study support incorporating both the Ref and THL heat strain indexes as dual metrics for characterizing the heat strain performance of turnout clothing fabrics.
- 2 May 2022
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 29 (2) , 562-572
Open AccessRelationship between heat loss indexes and physiological indicators of turnout-related heat strain in mild and hot environments
A validated physiological manikin method was used to qualify environmentally dependent correlations between firefighter turnout total heat loss (THL) and intrinsic evaporative resistance (Ref) heat strain indexes and core temperature rise in stressful work conducted in mild (25 °C, 65% relative humidity [RH]) and hot (35 °C, 40% RH; 40 °C, 28% RH) conditions. Five turnout suit constructions representing a wide range of breathability were selected. The observed correlations between measured material heat loss and core temperature showed that the THL heat strain index accurately forecast thermal burden in mild environments (35 °C). They showed that the THL index did not predict heat strain in hot work environments. The findings of this study support incorporating both the Ref and THL heat strain indexes as dual metrics for characterizing the heat strain performance of turnout clothing fabrics.
- 22 July 2021
- Published by SAGE Publications in Textile Research Journal
- Vol. 92 (1-2) , 219-231
Effects of environmental temperature and humidity on evaporative heat loss through firefighter suit materials made with semi-permeable and microporous moisture barriers
The goal of this research was to understand how firefighter protective suits perform in different operational environments. This study used a sweating guarded hotplate to examine the effect of environmental temperature (20–45°C) and relative humidity (25–85% RH) on evaporative heat loss through firefighter turnout materials. Four firefighter turnout composites containing three different bi-component (semi-permeable) and one microporous moisture barriers were selected. The results showed that the evaporative resistance of microporous moisture barrier systems was independent of environmental testing conditions. However, absorbed moisture strongly affected evaporative heat loss through semi-permeable moisture barriers coated with a layer of nonporous hydrophilic polymer. Moisture absorption in mild environment (20–25°C) tests, or when testing at high humidity (>85% RH), significantly increased water vapor transmission in semi-permeable turnout systems. It was also found that environmental conditions used in the total heat loss (THL) test (25°C and 65% RH) produced moisture condensation in bi-component barrier systems, making them appear more breathable than could be expected when worn in hotter environments. Regression models successfully qualified the relationships between moisture uptake levels in semi-permeable barrier systems and evaporative resistance and THL. These findings reveal the limitations in relying on THL, the heat strain index currently called for by the NFPA 1971 Standard for Structural Firefighter personal protective equipment, and supports the need to measure turnout evaporative resistance at 35°C (Ret), in addition to THL at 25°C.
- 22 July 2021
- Published by SAGE Publications in Textile Research Journal
- Vol. 92 (1-2) , 219-231
Effects of environmental temperature and humidity on evaporative heat loss through firefighter suit materials made with semi-permeable and microporous moisture barriers
The goal of this research was to understand how firefighter protective suits perform in different operational environments. This study used a sweating guarded hotplate to examine the effect of environmental temperature (20–45°C) and relative humidity (25–85% RH) on evaporative heat loss through firefighter turnout materials. Four firefighter turnout composites containing three different bi-component (semi-permeable) and one microporous moisture barriers were selected. The results showed that the evaporative resistance of microporous moisture barrier systems was independent of environmental testing conditions. However, absorbed moisture strongly affected evaporative heat loss through semi-permeable moisture barriers coated with a layer of nonporous hydrophilic polymer. Moisture absorption in mild environment (20–25°C) tests, or when testing at high humidity (>85% RH), significantly increased water vapor transmission in semi-permeable turnout systems. It was also found that environmental conditions used in the total heat loss (THL) test (25°C and 65% RH) produced moisture condensation in bi-component barrier systems, making them appear more breathable than could be expected when worn in hotter environments. Regression models successfully qualified the relationships between moisture uptake levels in semi-permeable barrier systems and evaporative resistance and THL. These findings reveal the limitations in relying on THL, the heat strain index currently called for by the NFPA 1971 Standard for Structural Firefighter personal protective equipment, and supports the need to measure turnout evaporative resistance at 35°C (Ret), in addition to THL at 25°C.
- 1 September 2020
- Published by ASTM International
- p. 18-30
Development of a Standard Testing Procedure for Evaluating Firefighter Protective Hoods on PyroHead Fire Test System
- 1 September 2020
- Published by ASTM International
- p. 18-30
Development of a Standard Testing Procedure for Evaluating Firefighter Protective Hoods on PyroHead Fire Test System
- 21 July 2016
- Published by SAGE Publications in Textile Research Journal
- Vol. 87 (3) , 270-284
Comparative studies on standard and new test methods for evaluating the effects of structural firefighting gloves on hand dexterity
This research identifies laboratory test methods designed to advance assessment of the effects of structural firefighter gloves on a firefighter’s ability to perform tasks with their hands. Two new hand dexterity test methods are discussed: a modified tool test for measuring glove effects on gross or whole hand motor control, and a novel cylinder lift method for evaluating glove effects on fine or fingertip hand dexterity. Data generated by testing a representative group of structural firefighter and other responder gloves are used to show that these new test methods provide less variable data and a more useful and informative assessment of the effects of glove construction on hand dexterity than that provided by standard small pin pegboard tests. Based on these comparisons, a combination of the newly developed tool and cylinder lift test methods are recommended for evaluating the effects of structural firefighter gloves on hand dexterity in standards used as the basis of certifying the performance of structural firefighter clothing.
- 21 July 2016
- Published by SAGE Publications in Textile Research Journal
- Vol. 87 (3) , 270-284
Comparative studies on standard and new test methods for evaluating the effects of structural firefighting gloves on hand dexterity
This research identifies laboratory test methods designed to advance assessment of the effects of structural firefighter gloves on a firefighter’s ability to perform tasks with their hands. Two new hand dexterity test methods are discussed: a modified tool test for measuring glove effects on gross or whole hand motor control, and a novel cylinder lift method for evaluating glove effects on fine or fingertip hand dexterity. Data generated by testing a representative group of structural firefighter and other responder gloves are used to show that these new test methods provide less variable data and a more useful and informative assessment of the effects of glove construction on hand dexterity than that provided by standard small pin pegboard tests. Based on these comparisons, a combination of the newly developed tool and cylinder lift test methods are recommended for evaluating the effects of structural firefighter gloves on hand dexterity in standards used as the basis of certifying the performance of structural firefighter clothing.
- 16 April 2013
- Published by Springer Nature in Fire Technology
- Vol. 50 (5) , 1285-1299
Skin Burn Translation Model for Evaluating Hand Protection in Flash Fire Exposures
- 16 April 2013
- Published by Springer Nature in Fire Technology
- Vol. 50 (5) , 1285-1299
Skin Burn Translation Model for Evaluating Hand Protection in Flash Fire Exposures
- 1 March 2011
- Published by SAGE Publications in Journal of Engineered Fibers and Fabrics
- Vol. 6 (1)
Factors Affecting the Thermal Insulation and Abrasion Resistance of Heat Resistant Hydro-Entangled Nonwoven Batting Materials for Use in Firefighter Turnout Suit Thermal Liner Systems
This paper describes a study on heat resistant nonwoven batting materials used as components in the construction of thermal liners systems in firefighter turnout suits. It examines relationships between the fiber composition and construction of hydroentangled nonwoven battings and properties that can affect their performance when used in this application. Relationships between batting porosity, weight, thermal insulation, bulk and abrasion resistance are examined in hydroentangled constructions made with oxidized PAN, para-aramid and meta-aramid fibers. Correlations observed between the insulation of batting materials components and the thermal protective performance of integrated multilayered fabric systems used in firefighter turnout suits are described.
- 1 March 2011
- Published by SAGE Publications in Journal of Engineered Fibers and Fabrics
- Vol. 6 (1)
Factors Affecting the Thermal Insulation and Abrasion Resistance of Heat Resistant Hydro-Entangled Nonwoven Batting Materials for Use in Firefighter Turnout Suit Thermal Liner Systems
This paper describes a study on heat resistant nonwoven batting materials used as components in the construction of thermal liners systems in firefighter turnout suits. It examines relationships between the fiber composition and construction of hydroentangled nonwoven battings and properties that can affect their performance when used in this application. Relationships between batting porosity, weight, thermal insulation, bulk and abrasion resistance are examined in hydroentangled constructions made with oxidized PAN, para-aramid and meta-aramid fibers. Correlations observed between the insulation of batting materials components and the thermal protective performance of integrated multilayered fabric systems used in firefighter turnout suits are described.
- 23 October 2010
- Published by Springer Nature in Fire Technology
- Vol. 47 (3) , 615-629
Development of Instrumented Manikin Hands for Characterizing the Thermal Protective Performance of Gloves in Flash Fire Exposures
- 23 October 2010
- Published by Springer Nature in Fire Technology
- Vol. 47 (3) , 615-629
Development of Instrumented Manikin Hands for Characterizing the Thermal Protective Performance of Gloves in Flash Fire Exposures